Power off Memory Function ● After the device is powered on, it will automatically resume the working status before power off. ● If the machine is running before power outage, the machine will automatically enter power-on status, and maintain the previous setting parameters.● If the machine is shut down before the power outage, then the machine will still be in power-off status.Defrost FunctionWhen the dehumidifier is running at a lower temperature, the system will automatically determine whether there is a presence of frost. If any frost exists, it will defrost automatically.The fan will keep running and the compressor will stop when defrosting. After this process, the compressor will restart to run.Temperature Protection FunctionWhen the ambient temperature is higher than the default high temperature of 113°F, the system will enter high temperature protection, the small number will indicate "HH", and the compressor will stop; When the ambient temperature is lower than the default low temperature of 39 °F, the system will enter the low temperature protection, the small number will indicate"LL", and the whole machine will stop.Cleaning Remind FunctionWhen the accumulative running time of the fan is ≥30 days, the machine can continue to run, but it will prompt " " and it will not be able to be removed even restarted.In power-off status, long press the "Function" button for seconds, then the display screen will show once, the" " prompt will be released, and the fan running time will be cleared.Special Note:To avoid any damage to the dehumidifier, the compressor features a "3 minutes delay protection" function, which is, when the dehumidifier is powered, the compressor can only start again 3 minutes later after its last shutdown. OPERATION INSTRUCTIONS