3
Installation
The product must be installed and maintained by a
VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW
building/construction and/or electrical regulations and
relevant legislation.
Warning: Switch off mains electrical supply prior to
installing and connecting the luminaire.
Notice:,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
Installation Procedure
1) Switch off the mains electrical supply.
2) Remove cover Aby releasing screws B.
3) Check that rating shown on luminaire label
conforms with mains electrical supply.
'HWHUPLQHSRVLWLRQVIRUƂ[LQJVFUHZVC. Drill
relevant holes Dand insert wall plugs E.
Warning: Ensure not to damage any electric cable,
water pipe or other devices while drilling holes.
5) Feed the mains supply cable F(and the second
cable Gfor through wiring, if required) through the
grommets Hat the bottom of the housing, while
VHWWLQJDQGƂ[LQJOXPLQDLUHSRVLWLRQ7RƂ[WKH
luminaire, pierce through the nylon plug Nwith
screws C, and tighten (Fig. I).
Attention: The nylon plugs Nmust remain in
position to provide sealing.
6) Connect mains supply leads to respective terminals
in terminal block I:
a) ON/OFF (L = Phase, N = Neutral, = Earthing)
b) 1-10 V/DALI (L = Phase, N = Neutral,
= Earthing, DA/DA = DALI control line,
D–/D+ = 1-10 V control line).
7) Reposition the cover Aand secure in position by
evenly tightening the screws B.