manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WE-EF
  6. •
  7. Outdoor Light
  8. •
  9. WE-EF ETV100 Series User manual

WE-EF ETV100 Series User manual

Other manuals for ETV100 Series

1

This manual suits for next models

4

Other WE-EF Outdoor Light manuals

WE-EF DOC100 LED Series User manual

WE-EF

WE-EF DOC100 LED Series User manual

WE-EF PFL540 LED User manual

WE-EF

WE-EF PFL540 LED User manual

WE-EF ZAT400 Series User manual

WE-EF

WE-EF ZAT400 Series User manual

WE-EF LTM440 LED User manual

WE-EF

WE-EF LTM440 LED User manual

WE-EF LEUCHTEN QLO229 User manual

WE-EF

WE-EF LEUCHTEN QLO229 User manual

WE-EF LTM440-FT User manual

WE-EF

WE-EF LTM440-FT User manual

WE-EF FLA780 User manual

WE-EF

WE-EF FLA780 User manual

WE-EF PLS420 LED User manual

WE-EF

WE-EF PLS420 LED User manual

WE-EF VFL530 User manual

WE-EF

WE-EF VFL530 User manual

WE-EF LTM444 User manual

WE-EF

WE-EF LTM444 User manual

WE-EF RMC320 LED User manual

WE-EF

WE-EF RMC320 LED User manual

WE-EF OLV300 LED Series User manual

WE-EF

WE-EF OLV300 LED Series User manual

WE-EF ASP530 LED User manual

WE-EF

WE-EF ASP530 LED User manual

WE-EF STO Series User manual

WE-EF

WE-EF STO Series User manual

WE-EF MRY224 User manual

WE-EF

WE-EF MRY224 User manual

WE-EF XRY324 LED User manual

WE-EF

WE-EF XRY324 LED User manual

WE-EF PIA240 LED User manual

WE-EF

WE-EF PIA240 LED User manual

WE-EF ETC100-GB LED Series User manual

WE-EF

WE-EF ETC100-GB LED Series User manual

WE-EF LEUCHTEN AFL100 Series User manual

WE-EF

WE-EF LEUCHTEN AFL100 Series User manual

WE-EF VLR110 LED User manual

WE-EF

WE-EF VLR110 LED User manual

WE-EF ESC130-FS User manual

WE-EF

WE-EF ESC130-FS User manual

WE-EF FLA740 LED User manual

WE-EF

WE-EF FLA740 LED User manual

WE-EF RRY324 User manual

WE-EF

WE-EF RRY324 User manual

WE-EF PIA230 LED User manual

WE-EF

WE-EF PIA230 LED User manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

urban ambiance UQL1273 installation instructions

urban ambiance

urban ambiance UQL1273 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Safety Notice
The manufacturer is discharged from liability when damage
is caused by improper use or installation.
If any luminaire and/or accessory is subsequently modi-
fied, the persons responsible for the modification shall be
considered as manufacturer.
ETV100_090621 / 006-1340
Technical specifications are subject to change.
© WE-EF 2022
WE-EF LIGHTING
Installation and
Maintenance Instructions for
Inground Uplights,linear
ETV100 Series
with installation blockout
BEV
we-ef.com
WE-EF LIGHTING USA
Tel +1 724 742 0030
[email protected]
Product Information / Surge Protection
As an option, this luminaire can also be fitted with a surge
protector of Type 2-3 (at the time of order). The technical
data can be found directly on the installed device. If the
surge protector has been triggered by an adverse event,
the luminaire is automatically disconnected from the
mains. In that case, the LED on the surge protector no
longer lights up.
For comprehensive protection of the luminaire against
lightning and electrical surges, primary (Type 1) and
secondary (Type 2) surge arrestors must be installed into
the power supply. We recommend a combination arrestor
(Type 1+2+3), which is installed in the control cabinet.
The technical planner/installer is responsible for the pro-
per selection, sizing and installation of the surge protection
modules that must be provided on site. Please note the
various protection levels for Class I and II, as well as the
applicable statutory provisions regarding surge protection.
Installation and maintenance may only be performed by a
qualified electrician.
h
d
[A6] = d : h = 1:10
[LA10] = d : h = 1:5
D1
D2
A
C
Installation Blockouts
made from anodised aluminium D1 D2 C A lb
for ETV120 186-0306 BEV (for 1 luminaire) 2.13 4.72 6.30 26.57 6.6
186-0307 BEV (for 2 luminaires) 2.13 4.72 6.30 51.34 13.8
186-0308 BEV (for 3 luminaires) 2.13 4.72 6.30 76.10 20.1
186-0309 BEV (for 4 luminaires) 2.13 4.72 6.30 100.87 26.5
for ETV130 186-0310 BEV (for 1 luminaire) 2.13 4.72 6.30 38.39 10.4
186-0311 BEV (for 2 luminaires) 2.13 4.72 6.30 74.96 19.8
186-0312 BEV (for 3 luminaires) 2.13 4.72 6.30 111.54 29.2
186-0313 BEV (for 4 luminaires) 2.13 4.72 6.30 148.11 38.6
for ETV140 186-0314 BEV (for 1 luminaire) 2.13 4.72 6.30 50.20 13.5
186-0315 BEV (for 2 luminaires) 2.13 4.72 6.30 98.58 25.9
186-0316 BEV (for 3 luminaires) 2.13 4.72 6.30 146.97 38.3
186-0317 BEV (for 4 luminaires) 2.13 4.72 6.30 195.35 50.77
Inground luminaire linear
IP67, IK08
ø 0.394 (max.)
ø 0.472 – 0.748
5.75
Installation Accessories
Sealable junction box
185-1624 SJB130 0.9 lb
ø 0.217 –0.472 in
26 – 14 AWG
DMX/0 – 10 V Power
L
1.89
2.13
3.07
L
ETV100
ETV100-CC
Class I, ta = 25°C
Dimensions / Weights
ETV120.............24.69 in................10.1 lb
ETV130.............36.50 in................13.2 lb
ETV140.............48.31 in................16.5 lb
Light source
ETV120/124 .........................32 LED 20W*
ETV130/134 .........................48 LED 30W*
ETV130/134 RGBW (DMX) .............96 LED 48W*
ETV130/134 TW (DMX) ................96 LED 30W*
ETV140/144 .........................64 LED 40W*
ETV140/144 RGBW (DMX) ............128 LED 64W*
ETV140/144 TW (DMX) ...............128 LED 40W*
ETV129..............................32 LED 2-3W*
ETV139..............................48 LED 3-4W*
ETV149..............................64 LED 4-6W*
* Nominal power, for latest data refer to
www.we-ef.com
Installation
The product must be installed and maintained by
a suitably qualified professional in compliance with
latest building/construction and/or electrical regulati-
ons and relevant legislation.
Luminaire can be driven over at low speed, without
accelerating or turning, by vehicles with air-filled tires,
at a weight up to 5 tonnes per wheel. Max. static load,
3 tonnes.
Do not open the luminaire in humid conditions or
during rain. This will result in condensation forming
inside the luminaire.
Maintenance
Apart from cleaning the product’s exterior surfaces,
no special maintenance work is required. Do not use
high-pressure cleaners.
A
B
Installation blockout BEV pic. 1
Installation blockout BEV pic. 2
Installation blockout BEV
Ensure that proper drainage is provided, e.g. a gravel
bedding.
1) Take the installation cover Aout of the installation
blockout B. Lead the connecting cable through the
drilled hole inside the blockout.
2) Place the cable at the bottom area of the blockout,
than replace the cover Aonto the blockout B. The
blockout needs to get placed on an even, stable
area. The top edge needs to be flush with surface.
ATTENTION: If the floor will be tiled or paved
afterwards leave an appropriate gap).
Warning: Switch off mains electrical supply prior to
installing and connecting the luminaire. Do not open
luminaire while mains supply is switched on.
Notice: If the luminaire is modified by anybody other
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
In case of component failure due to abnormal circum-
stances or at end of life, replacement must be carried
out by a suitably qualified and trained professional.
In case of questions please contact our technical hot-
line at +1 724 742 0030 (Monday - Friday from 08:00
until 16:00 hours).
3) In case the luminaire gets installed at a later time,
the blockout must get covered by the installation
cover A, to make sure no concrete or dirt may
enter the luminaire.
The installation cover ensures that the blockout
does not get damaged during masonry works and
needs to remain inside the BEV until installation of
the luminaire.
F
G
D
E
C
L, N, PE, D+, D-
Linear inground luminaire ETV100 pic. 1
F
E
C
L, N, PE
DMX
D
G
Linear inground luminaire ETV100-CC pic. 1
Installation luminaire uplight ETV
1) Switch off mains electrical supply.
2) The luminaire is pre-wired and the lamp/LED inclu-
ded. An opening of the luminaire is not necessary.
3) Take the installation cover A and the spacers Eout
of the blockout B.
4) Connect the connecting cable with the provided
UL410–D gel–filled wire nuts of the luminaire and
place the clamp inside the connection sleeve D.
5) Place the connection sleeve Dand the luminaire C
inside the blockout. Make sure no cable is squeezed.
6) Install the spacer E. In case the space for the lumin-
aire(s) is not sufficient you can remove individual
silicone buffer G.
To remove the luminaire unfasten the screws Ffrom
the spacer Euntil you can clasp these and pull out the
spacer in an upwards direction.
Linear inground luminaire ETV100 pic. 3
F
C
Linear inground luminaire ETV100 pic. 2
max.
1,0 Nm
(8.9 in–lb)
white
black
gree
n
red
DMX out +
DMX out -
DMX Shield
DMX in +
DMX in -
DMX Shield
black
white
gree
n
L
N
Wiring Diagramm (CC)
DMX L, N, PE