Installation and Startup Guide
This document covers the installation of MT8071iER1 Series HMI, for the detailed specifications and
operation, please refer to Brochure and EasyBuilder Pro User Manual.
Install Environment:
NEMA Rating
MT8071iER1 Series HMI is NEMA 4 rated (Indoor Use Only).
Electrical
Environment
MT8071iER1 Series has been tested to conform to European CE requirements.
This means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the displays are installed correctly and that the operating limits
are followed. Avoid installing units in environments where severe mechanical
vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to flammable
gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in Pollution
Degree 2 Environment.
Unpacking the Unit
Unpack and check the delivery. If damage is found,
notify the supplier.
Installation Instructions
1. Around the cutout on the control cabinet,
draw the reference lines for positioning the
overlay. Panel Cutout: 174.6mm x 113.6mm
2. Select the mounting holes according to the
wall thickness of control cabinet and secure
the mounting brackets onto both sides of the
HMI unit.
3. Secure the HMI to the cabinet by four studs.
4. Affix the overlay (user-prepared) to the
cabinet front surface.
USB Stick Clamp Usage
Combining the USB Stick with the clamp and the tying strap can prevent USB stick from disconnecting
with HMI when strong vibration is present.
1. Insert the USB connector to the clamp and tie them together with the tying strap.
2. Press the spring and insert the USB stick into HMI.
Power Connections
NOTE:
1. Connect positive DC line to the ‘+’ terminal and the DC ground to the ‘-’
terminal.
2. When using a USB cable to download project file, please do not
connect HMI with PLC and PC simultaneously to prevent potential
difference from destroying USB ports of HMI and PC.
Panel Thickness Range
1.5mm [0.06"]
3.5mm [0.13"]
~
2mm [0.08"]
2.4mm [0.09"]
2.5mm [0.1"]
2.9mm [0.11"]
1.9mm [0.07"]
1.5mm [0.06"]
3mm [0.12"]
3.5mm [0.13"]
~~~~
wall
11.95mm [0.47"]
8.1mm [0.32"] (9.85mm [0.39"])
(13mm [0.51"])
?.7mm [?.15"]
?.5mm [?.14"]
M3 x 0.5P x 8L
HEX NUTS M3 x 0.5 P
189.6mm [7.46"]
137.08mm [5.40"]
189.6mm [7.46"]
137.08mm [5.40"]
5.1mm [0.20"]
26.15mm [1.03"]
3mm [0.12"]
34.25mm [1.35"]
cdefg
174.6mm [6.87"]
113.6mm [4.47"]
MT8070iER:
174.6mm [6.87"] W x 113.6mm [4.47"] H
213.6mm [8.41"]
100mm [3.94"]
20.15mm [0.79"]
13.3mm [0.52"]
ba
Maximum Wall Thickness : 3.5 mm [ 0.13"]
MT8071iER1 series
Installation Instruction
NOTE:
Place the operator panel on a stable surface during
installation. Dropping it or letting it fall may cause
damage.
1
2
3
4
(1) Installation Instruction, 2-sided A4 *1
(2) Rear-Mount HMI *1
(3) Power Connector *1
(4) Fuse 1.25A/250V 5*20mm *1
(5) USB Stick Clamp & Tying Strap *1
(1)
(2)
(3)
(4)
(5)
Panel Thickness Range
1.5mm [0.06"]
3.5mm [0.13"]
wall
11.95mm [0.47"]
8.1mm [0.32"] (9.85mm [0.39"])
(13mm [0.51"])
192.55mm [7.58"]
138.55mm [5.45"]
2mm [0.08"]
2.4mm [0.09"]
2.5mm [0.1"]
2.9mm [0.11"]
1.9mm [0.07"]
1.5mm [0.06"]
3mm [0.12"]
3.5mm [0.13"]
~~~~
Ø4mm [Ø0.16"] Ø3.7mm [Ø0.15"]
M3 x 0.5P x 8L
HEX NUTS M3 x 0.5 P
System Settings
When HMI is powered up and displays image,
click the system setting button.
(Default System Password: 111111)
It is necessary to connect the HMI to
your network through a RJ-45 cable.
EasyBuilder Pro Software Settings
Launch EasyBuilder Pro software, select your
project file, press F7 shortcut key to open
the download dialog box:
Select Ethernet > IP tab > Enter your HMI IP
> Click Download to download this project
file to HMI.
( Please refer to EasyBuilder Pro User Manual
for software operation details )
Communication Connections
COM1 RS232, 9 Pin, Male, D-sub COM2/3 RS485, 9 Pin, Female, D-sub
DIP SW Settings
Limited Warranty
This product is limited warranted against defects in design and manufacture.
The proven defective product will either be repaired or replaced, at Weintek’s discretion.
This warranty shall not cover any product which is
(a) Out of warranty period which is 12 months from the manufacturing month of the HMI products.
(b) Damage caused by Force Majeure, accident, negligence, improper installation or misuse.
(c) Product has been repaired or taken apart by unauthorized technicians.
(d) Products whose identification markings have been removed or damaged.
SW1
SW2
SW3
SW4
Mode
ON
OFF
OFF
OFF
Touch Screen Calibration Mode
OFF
ON
OFF
OFF
Hide HMI System Setting Bar
OFF
OFF
ON
OFF
Boot Loader Mode
OFF
OFF
OFF
ON
Not supported
OFF
OFF
OFF
OFF
Normal
NOTE: Another method to enter touch screen calibration mode: Press
and hold anywhere on the screen for more than 2 seconds when HMI
starts.
NOTE: COM2 and COM3 [RS485] 2W support MPI 187.5K, please use one at one time.
CAUTION
NN
NOTE:
Make sure that all local and national electrical standards are met when installing
the unit. Contact your local authorities to determine which codes apply.
PIN#
Symbol
COM1 [RS232]
1
Not used
2
RxD
Received Data
3
TxD
Transmitted Data
4
Not used
5
GND
Ground
6
Not used
7
RTS
Ready to send output
8
CTS
Clear to send input
9
Not used
PIN#
Symbol
COM2 [RS485]
COM3
[RS485]
2W
4W
1
Rx-
Data-
Rx-
2
Rx+
Data+
Rx+
3
Tx-
Tx-
4
Tx+
Tx+
5
GND
Ground
6
Data-
Data-
7
Not used
8
Not used
9
Data+
Data+
Go to the Network tab, you may choose
to auto get DHCP IP, or designate your
own IP.
5
Power
The unit can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with
most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 2A.
Fusing
Require-
ments
If the display does not come on within 5 seconds of power up, remove power.An internal fuse will
prevent damage if the polarity of the DC power is incorrect. Check wiring for proper connections
and try to power up again.
High
Voltage
An Internal fuse will prevent damage for overcurrent condition however it isn’t guaranteed. DC
voltage sources should provide proper isolation from main AC power and similar hazards.
Emergency
Stop
A Hard-wired EMERGENCY STOP should be fitted in any system using HMI to comply with ICS
Safety Recommendations.
Supply
Voltage
Condition
Do not power the unit and inductive DC loads, or input circuitry to the controller, with the same
power supply. Note: The 24 VDC output from some controllers may not have enough current to
power the unit.
Wire
Routing
a. Power wire length should be minimized (Max: 500m shielded, 300m unshielded).
b. Please use twisted pair cables for power wire and signal wire and conform to the impedance
matching.
c. If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices.
d. Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires.
e. Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency dissipation.
Typical values to use are 1M Ohm and 4700pF.
CAUTION
NOTE: Make sure that all local and national electrical standards are met when
installing the unit. Contact your local authorities to determine which codes apply.
Hardware
Considerations
The system designer should be aware that devices in Controller systems could fail and thereby
create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to
equipment start-up, which could result in property damage and/or physical injury to the operator.
If you use any programmable control systems that require an operator, be aware that this potential
safety hazard exists and take appropriate precautions. Although the specific design steps depend on
your particular application, the following precautions generally apply to installation of solid-state
programmable control devices, and conform to the guidelines for installation of Controllers
recommended in NEMA ICS 3-304 Control Standards.
Programming
Considerations
To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure
that all writable registers that control critical parts of plant or machinery have limit checks built into
the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.
GME8071ER_MT8071iER1_Installation_150609
DANGER
6
7
8

Other weintek Control Panel manuals

weintek cMT-FHDX User manual

weintek

weintek cMT-FHDX User manual

weintek cMT-SVR Series User manual

weintek

weintek cMT-SVR Series User manual

weintek cMT-FHDX User manual

weintek

weintek cMT-FHDX User manual

weintek MT-6050iV3 Series User manual

weintek

weintek MT-6050iV3 Series User manual

weintek MT6071iP Series User manual

weintek

weintek MT6071iP Series User manual

weintek MT607iE User manual

weintek

weintek MT607iE User manual

weintek cMT3072XH2 Series User manual

weintek

weintek cMT3072XH2 Series User manual

weintek cMT-iPC10 series User manual

weintek

weintek cMT-iPC10 series User manual

weintek cMT3090 Series User manual

weintek

weintek cMT3090 Series User manual

weintek MT6071 Series User manual

weintek

weintek MT6071 Series User manual

weintek HMIVT8071iE Series User manual

weintek

weintek HMIVT8071iE Series User manual

weintek MT6071iE Series User manual

weintek

weintek MT6071iE Series User manual

weintek MT600iWP Series User manual

weintek

weintek MT600iWP Series User manual

weintek MT-8000 Series User manual

weintek

weintek MT-8000 Series User manual

weintek M02 User guide

weintek

weintek M02 User guide

weintek cMT2166X Series User manual

weintek

weintek cMT2166X Series User manual

weintek MT8103iE Series User manual

weintek

weintek MT8103iE Series User manual

weintek cMT3072X2 Series User manual

weintek

weintek cMT3072X2 Series User manual

weintek MT8101iE Series User manual

weintek

weintek MT8101iE Series User manual

weintek cMT3162X Series User manual

weintek

weintek cMT3162X Series User manual

weintek MT8073iE Series User manual

weintek

weintek MT8073iE Series User manual

weintek cMT3108XP Series User manual

weintek

weintek cMT3108XP Series User manual

weintek cMT3108XH Series User manual

weintek

weintek cMT3108XH Series User manual

weintek MT-8080T User manual

weintek

weintek MT-8080T User manual

Popular Control Panel manuals by other brands

PCB Piezotronics 070A33 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 070A33 Installation and operating manual

Frigidaire FEB30T7DCB owner's guide

Frigidaire

Frigidaire FEB30T7DCB owner's guide

DUYAR HYDROPHORE Installation, maintenance and operation guide

DUYAR

DUYAR HYDROPHORE Installation, maintenance and operation guide

Siemens SIMATIC HMI series Getting started

Siemens

Siemens SIMATIC HMI series Getting started

Detnov CAD-250 user manual

Detnov

Detnov CAD-250 user manual

Motorline professional MPXR92MSWBE User& installer's manual

Motorline professional

Motorline professional MPXR92MSWBE User& installer's manual

IGD TOC 635 PLUS Operation, Maintenance and Safety Instruction Manual

IGD

IGD TOC 635 PLUS Operation, Maintenance and Safety Instruction Manual

Tunstall Flamenco operating instructions

Tunstall

Tunstall Flamenco operating instructions

Carrier HumidiTrac Safety and installation instructions

Carrier

Carrier HumidiTrac Safety and installation instructions

IDTECK iTDC Quick installation guide

IDTECK

IDTECK iTDC Quick installation guide

Secutron MR-2300 series Installation and operation manual

Secutron

Secutron MR-2300 series Installation and operation manual

Coloronix SCC3 Manual guide

Coloronix

Coloronix SCC3 Manual guide

Exodraft EBC24 Series Installation and operation manual

Exodraft

Exodraft EBC24 Series Installation and operation manual

BFT LEO-D-MA user manual

BFT

BFT LEO-D-MA user manual

Sony CCP-9000A-C Operation manual

Sony

Sony CCP-9000A-C Operation manual

Kenwood RC-D710 brochure

Kenwood

Kenwood RC-D710 brochure

Calira Check-Panel 210 operating instructions

Calira

Calira Check-Panel 210 operating instructions

Riello 20081467 manual

Riello

Riello 20081467 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.