manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. weintek
  6. •
  7. Control Panel
  8. •
  9. weintek MT8101iE Series User manual

weintek MT8101iE Series User manual

Installation and Startup Guide
Install Environment:
Electrical
Environment
wire routing and grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the displays are installed correctly and that the operating
limits are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in
Pollution Degree 2 Environment.
Unpacking the Unit
Unpack and check the delivery. If damage is found,
notify the supplier.
Installation Instructions
Secure the operator panel in position, using all the fastening holes and the provided brackets
and screws:
Type
A(mm)
B(mm)
MT6071iE
192
138
MT8071iE
192
138
MT8101iE
260
202
Power Connections
System Settings
Installation Instruction
1
2
NOTE:
Place the operator panel on a stable
surface during installation. Dropping it or
letting it fall may cause damage.
NOTE: For the details of HMI
DIP SW function settings please
refer to Part 8 in this guide.
Go to the Network tab, you may choose
to auto get DHCP IP, or designate your
own IP.
NOTE:
1. Connect positive DC line to the ‘+’ terminal
and the DC ground to the ‘-’terminal.
2. Please do not connect HMI with PLC and PC
simultaneously to prevent potential difference
from destroying USB ports of HMI and PC.
(A)
(B)
Cutout
(1) Installation Instruction, 2-sided A4 *1
(2) Human Machine Interface *1
(3) Power Connector *1
(4) Brackets & Screws *1 pack
(5) Fuse 1.25A/250V 5*20mm *1
3
5
4
(1)
(2)
(5)
(4)
(3)
This document covers the installation of MT6071/8071/8101iE Series HMI, for the detailed
specifications and operation, please refer to Brochure and EasyBuilder Pro User Manual.
When HMI is powered up and displays image,
click the system setting button.
(Default System Password: 111111)
It is necessary to connect the HMI to
your network through a RJ-45 cable.
MT8101iE series
NEMA Rating MT8101iE Series HMI is NEMA 4 rated (Indoor Only).
MT8101iE Series has been tested to conform to European CE requirements.
This means that the circuitry is designed to resist the effects of electrical noise.
This does not guarantee noise immunity in severe cases. Proper
EasyBuilder Pro Software Settings
Launch EasyBuilder Pro software, select your
project file, press F7 shortcut key to open
the download dialog box:
Select Ethernet > IP tab > Enter your HMI IP
> Click Download to download this project
file to HMI.
If use MT6071iE, please select USB cable.
( Please refer to EasyBuilder Pro User Manual
for software operation details )
Communication Connections
9 Pin, Male, D-sub
COM1 [RS232]
9 Pin, Female, D-sub
COM2 / COM3 [RS485]
DIP SW Settings
CAUTION
NN
Limited Warranty
This product is limited warranted against defects in design and manufacture.
The proven defective product will either be repaired or replaced, at Weintek’s discretion.
This warranty shall not cover any product which is
(a) Out of warranty period which is 12 months from the manufacturing month of the HMI products.
(b) Damage caused by Force Majeure, accident, negligence, improper installation or misuse.
(c) Product has been repaired or taken apart by unauthorized technicians.
(d) Products whose identification markings have been removed or damaged.
NOTE:
Make sure that all local and national electrical standards are met when installing
the unit. Contact your local authorities to determine which codes apply.
PIN#
Symbol
COM1 [RS232]
1
Not used
2
RxD
Received Data
3
TxD
Transmitted Data
4
Not used
5
GND
Signal Ground
6
Not used
7
RTS
Ready to send output
8
CTS
Clear to send input
9
Not used
PIN#
Symbol
Com2
[RS485]2w
Com2
[RS485]4w
Com3
[RS485]
1
Rx-
Data-
Rx-
2
Rx+
Data+
Rx+
3
Tx-
Tx-
4
Tx+
Tx+
5
GND
Signal Ground
6
Data-
Data-
7
Not used
8
Not used
9
Data+
Data+
SW1
SW2
SW3
SW4
Mode
ON
OFF
OFF
OFF
Touch Screen Calibration Mode
OFF
ON
OFF
OFF
Hide HMI System Setting Bar
OFF
OFF
ON
OFF
Boot Loader Mode
OFF
OFF
OFF
ON
Not supported
OFF
OFF
OFF
OFF
Normal
NOTE: COM2 and COM3 [RS485] 2W support MPI 187.5K, please use one at one time.
6
7
8
Power
The HMI can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with
most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 2A.
Fusing
Require-
ments
If the display does not come on within 5 seconds of power up, remove power.An internal fuse will
prevent damage if the polarity of the DC power is incorrect. Check wiring for proper connections
and try to power up again.
High
Voltage
An Internal fuse will prevent damage for overcurrent condition however it isn’t guaranteed. DC
voltage sources should provide proper isolation from main AC power and similar hazards.
Emergency
Stop
A Hard-wired EMERGENCY STOP should be fitted in any system using HMI to comply with ICS
Safety Recommendations.
Supply
Voltage
Condition
Do not power the HMI and inductive DC loads, or input circuitry to the controller, with the same
power supply. Note: The 24 VDC output from some controllers may not have enough current to
power the HMI.
Wire
Routing
a. Power wire length should be minimized (Max: 500m shielded, 300m unshielded).
b. Please use twisted pair cables for power wire and signal wire and conform to the impedance
matching.
c. If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices.
d. Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires.
e. Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency dissipation.
Typical values to use are 1M Ohm and 4700pF.
CAUTION
NOTE: Make sure that all local and national electrical standards are met when
installing the unit. Contact your local authorities to determine which codes apply.
Hardware
Considerations
The system designer should be aware that devices in Controller systems could fail and thereby
create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to
equipment start-up, which could result in property damage and/or physical injury to the operator.
If you use any programmable control systems that require an operator, be aware that this potential
safety hazard exists and take appropriate precautions. Although the specific design steps depend on
your particular application, the following precautions generally apply to installation of solid-state
programmable control devices, and conform to the guidelines for installation of Controllers
recommended in NEMA ICS 3-304 Control Standards.
Programming
Considerations
To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure
that all writable registers that control critical parts of plant or machinery have limit checks built into
the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.
GME680710_MT6071_8071_8101iE1_Installation_140522
DANGER
CAUTION
NN
NOTE:
Make sure that all local and national electrical standards are met when installing
the unit. Contact your local authorities to determine which codes apply.

This manual suits for next models

3

Other weintek Control Panel manuals

weintek cMT3072XH2 Series User manual

weintek

weintek cMT3072XH2 Series User manual

weintek cMT3072X2 Series User manual

weintek

weintek cMT3072X2 Series User manual

weintek MT-8080T User manual

weintek

weintek MT-8080T User manual

weintek MT6071iE Series User manual

weintek

weintek MT6071iE Series User manual

weintek cMT3090 Series User manual

weintek

weintek cMT3090 Series User manual

weintek MT8103iE Series User manual

weintek

weintek MT8103iE Series User manual

weintek cMT-SVR Series User manual

weintek

weintek cMT-SVR Series User manual

weintek MT8073iE Series User manual

weintek

weintek MT8073iE Series User manual

weintek MT600iWP Series User manual

weintek

weintek MT600iWP Series User manual

weintek cMT-iPC10 series User manual

weintek

weintek cMT-iPC10 series User manual

weintek MT6071 Series User manual

weintek

weintek MT6071 Series User manual

weintek MT-6050iV3 Series User manual

weintek

weintek MT-6050iV3 Series User manual

weintek MT-8000 Series User manual

weintek

weintek MT-8000 Series User manual

weintek MT607iE User manual

weintek

weintek MT607iE User manual

weintek MT6071iP Series User manual

weintek

weintek MT6071iP Series User manual

weintek cMT3162X Series User manual

weintek

weintek cMT3162X Series User manual

weintek HMIVT8071iE Series User manual

weintek

weintek HMIVT8071iE Series User manual

weintek MT6072 Series User manual

weintek

weintek MT6072 Series User manual

weintek cMT3108XP Series User manual

weintek

weintek cMT3108XP Series User manual

weintek cMT2166X Series User manual

weintek

weintek cMT2166X Series User manual

weintek cMT-FHDX User manual

weintek

weintek cMT-FHDX User manual

weintek MT8071iER1 Series User manual

weintek

weintek MT8071iER1 Series User manual

weintek cMT-FHDX User manual

weintek

weintek cMT-FHDX User manual

weintek cMT3108XH Series User manual

weintek

weintek cMT3108XH Series User manual

Popular Control Panel manuals by other brands

Aiphone IX SERIES Programming guide

Aiphone

Aiphone IX SERIES Programming guide

Bosch D7412GV2 Operation and installation guide

Bosch

Bosch D7412GV2 Operation and installation guide

Autonics Omron GP Series User Manual for Communication

Autonics

Autonics Omron GP Series User Manual for Communication

UPS Aviation Technologies 10 user guide

UPS Aviation Technologies

UPS Aviation Technologies 10 user guide

Air Liquide SGA2 operating instructions

Air Liquide

Air Liquide SGA2 operating instructions

Russound SaphIR K2 Specifications

Russound

Russound SaphIR K2 Specifications

Advanced Electronics Mx-4200N manual

Advanced Electronics

Advanced Electronics Mx-4200N manual

Honeywell Galaxy 18Galaxy Programming manual

Honeywell

Honeywell Galaxy 18Galaxy Programming manual

Leviton Z-MAX Series user guide

Leviton

Leviton Z-MAX Series user guide

ESAB 0558001912 Installation and operation guide

ESAB

ESAB 0558001912 Installation and operation guide

Philips SBCRU1000/05 Specifications

Philips

Philips SBCRU1000/05 Specifications

Viking spas TP500S Series manual

Viking spas

Viking spas TP500S Series manual

Extron electronics ACP 100 Setup guide

Extron electronics

Extron electronics ACP 100 Setup guide

Alfaled AFT-20 quick start guide

Alfaled

Alfaled AFT-20 quick start guide

GE Security NetworX Series NX-8V2 installation instructions

GE Security

GE Security NetworX Series NX-8V2 installation instructions

Graff G-8251 instruction manual

Graff

Graff G-8251 instruction manual

Mastervolt EasyView 5 User and installation manual

Mastervolt

Mastervolt EasyView 5 User and installation manual

Northern N-1000-III Installation and programming manual

Northern

Northern N-1000-III Installation and programming manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.