Please read this manual carefully before starting to use your product.
Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire.
This product is for indoor use only.
Use AC 220-240V only.
Do not attempt to repair or modify the unit. All repairs should be completed by a qualified technician.
The plug for this unit is polarized, do not alter the plug in any way, do not force it into an electrical outlet. If the
plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a
proper outlet.
Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose. If the power plug is
damaged, it must be replaced by the manufacturer or a qualified technician.
Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power
cord.
Periodically remove dust from the power plug. This will reduce the chance that humidity will accumulate, which
increases the risk of electric shock.
Remove the power plug from the outlet when the unit is not in use or before cleaning the unit. When removing
the power plug, grasp by holding the plug itself, never hold by the cord.
Do not handle the power plug with wet hands.
Do not operate the unit when using indoor smoke-generating insecticides and do not spray insecticides
Do not use the unit near flammable gases.
Do not clean unit with benzene or paint thinner.
Do not use the unit where it is humid or where the unit may get wet, such as in a bathroom.
Do not insert fingers or foreign objects into the air intake or outlet.
Do not use near cigarettes, incense, or other spark-creating items.
Unit will not remove carbon monoxide emitted from heating appliances or other sources.
Do not block the intake or outlet vents.
Do not use near hot objects, such as a stove.
Do not use where the unit may come into contact with water.
Do not use the unit on its side.
Keep away from products that generate oily residue, such as a deep fryer.
Do not use where the unit may come into contact with steam.
Do not use detergent to clean the unit.
Do not operate without a filter.
Do not wash and reuse the HEPA Filter (Only WACP150)
NOTE: Follow these instructions for best results.
• Place unit at least 2 feet from the wall.
• Keep unit away from drafty areas.
• Keep curtains away from unit, as they may interfere with air intake/outlet.
• Place unit on a stable surface with plenty of air circulation.
• Ultra-Quiet: Ideal for night time operation.
• Air Quality Sensors: This air purifier automatically monitors air quality. In “Auto” mode, as air quality levels
change, fan speed will adjust automatically.
• Four-Speed Setting: From LOW for quiet and energy-efficient up to TURBO for the most effective cleaning.
• Replacement Filter Indicator Lights: Indicate when to replace your filters.
• Four-stage air cleaning system: Pre filter, HEPA filter, Cleancel™ antimicrobial treated Carbon filter and
PlasmaWave, removes 99.97% of pollutants. as small as 0.03 microns, including mold spores, pollen, dust mites,
most airborne microbes, allergens and cigarette smoke.
• PlasmaWaveTM Technology: safely removes airborne pollutants at the molecular level, instantly neutralizing
viruses and bacteria in the air.
• Remote control: Adjust your Air Cleaner settings with a simple click, from anywhere in the room.
• Four Stage Filters Cassette: Allow easy maintenance and replacement of all filters at once.
1. Remove protective film from the control panel.
2. Remove the front panel by grasping the bottom outside edges and gently pulling toward you.
3. Pull out the filters cassette and remove sealed plastic wrap.
4. Return the filters cassette to the unit.
5. Replace the front panel by hooking the front panel on the top of the unit. Swing panel in by pushing gently until
the panel snaps into place.
6. Plug in the power cord to a wall outlet.
7. Press POWER button until short “beep” is heard. For the first 3 to 4 minutes after turning the unit on, the
indicators will flash while the unit measures air quality. Once the sensor has calibrated, the lights will stop flashing
and the unit will begin in AUTO mode.
8. Remove tab from remote control (WAC-P300 and WAC-P450 only).
A. AIR QUALITY SENSOR: Automatically monitors the air quality level and adjusts fan speed accordingly in Auto.
B. AUTO: Changes the mode setting to AUTO.
C. RESET: Resets the CHECK FILTER indicator light.
D. CHECK FILTER: Signals when to replace filters.
E. PLASMAWAVE™: Shows that PlasmaWave™ Technology is active.
F. AIR QUALITY: Green, yellow, and red lights indicate the quality of the air.
G. Turbo / High / Med / Quiet: Shows current fan speed setting.
H. SPEED: adjusts fan speed to QUIET, MED, HIGH or TURBO.
I. : Turns the unit On and Off.
J. LIGHT SENSOR: dims the control panel lights and sets the fan speed to QUIET when the room is dark.
AUTOMATIC OPERATION: The unit is set to automatic operation when it is first turned on. The air purifier will
automatically sense the amount of impurities in the air, and adjust the fan speed to keep your air purified.
MANUAL OPERATION: After you turn on the unit, you can switch to manual operation by using the SPEED
button. To go back to the automatic operation press AUTO.
QUIET, MED OR HIGH: These levels are recommended for standard daytime use. HIGH will activate
automatically when sensors detect poor air quality in AUTOMATIC OPERATIONS. Use the SPEED button to
select the required level.
TURBO: This is the highest fan speed. It can be activated manually for maximum air purification by pushing the
SPEED button several times
How to turn ON/OFF PlasmaWave™: PlasmaWave OFF: Push Auto Button for 3 seconds (Indicator OFF)
PlasmaWave ON: Push Auto Button for 3 seconds (Indicator ON)