1008
21
Wireless Interlinked Smoke Alarm XS01-WR

01
English
This user manual contains important information regarding the operation
of your X-Sense smoke alarm. Ensure you read this user manual fully before
installing and operating the alarm. If you are installing this smoke alarm for
use by others, you must leave this manual (or a copy of it) with the end user.
Package Contents
Contents
English 01-24
Deutsch 25-49
Français 50-75 1 × Alarm Unit 1 × Mounting Bracket 2 × Screws
2 × Anchor Plugs 1 × User Manual

02 03
Safety Information
IMPORTANT
1. DANGERS, WARNINGS, AND CAUTIONS ALERT YOU TO IMPORTANT
OPERATING INSTRUCTIONS OR TO POTENTIALLY HAZARDOUS SITUATIONS.
PAY SPECIAL ATTENTION TO THESE SITUATIONS.
2. THIS ALARM IS NOT INTENDED TO ALERT HEARING IMPAIRED INDIVIDUALS.
THE USE OF ALCOHOL OR DRUGS MAY ALSO IMPAIR ONE’S ABILITY TO
HEAR THE SMOKE ALARM.
3. FIRES IN CHIMNEYS, WALLS, ROOFS, DIFFERENT LEVELS OR BEHIND CLOSED
DOORS MIGHT NOT BE DETECTED.
4. THIS DEVICE DOES NOT DETECT FLAMES, HEAT, CARBON MONOXIDE OR
OTHER HAZARDOUS GASES.
WARNING
1. NEVER IGNORE ANY ALARM. FAILURE TO RESPOND CAN RESULT IN SERIOUS
INJURY OR DEATH.
2. THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT
CORRECT A PROBLEM. ALWAYS CHECK YOUR HOME FOR A POTENTIAL
PROBLEM AFTER ANY ALARM. FAILURE TO DO SO CAN RESULT IN INJURY
OR DEATH.
3. TEST THIS SMOKE ALARM ONCE A WEEK. IF THE ALARM EVER FAILS TO
TEST CORRECTLY, REPLACE IT IMMEDIATELY! IF THE ALARM CANNOT WORK
PROPERLY, IT WILL NOT ALERT YOU TO A PROBLEM.
How to Set up and Interconnect Wireless Alarms
All X-Sense Link+wireless interlinked alarms contain a built-in RF module that
enables you to wirelessly connect 2 or more interlinked alarms and create an
interlinked network. When one unit is triggered, all interconnected alarms
will sound. The X-Sense Link+series contain wireless interlinked smoke
alarms, wireless interlinked carbon monoxide alarms, and wireless interlinked
combination smoke and carbon monoxide alarms. This model is designed to
be wirelessly interlinked with other X-Sense Link+ alarms, but is not designed
to communicate with wireless interlinked alarms from other manufacturers.
The X-Sense Link+wireless interlinked alarms in one multi-pack have
already been interconnected, and the alarms in each multi-pack have
their own independent interlinked network. If you have more than one
multi-pack, you will need to connect them all to the same network.
Choose one multi-pack as your base network and connect the other
multi-packs to it.
NOTE! The following instructions regarding wireless interconnection are
applicable to the X-Sense Link+ wireless interlinked alarms only.
How to Interconnect
1. Make sure you only work with 2 units at a time, and make sure that they
are both turned on to ensure successful connection.

04 05
NOTE: To turn on XS01-WR, remove the battery insulating lm from
the battery compartment. To learn how to turn on dierent models of
wireless interlinked alarms, please refer to their specic user manuals
for more details.
2. Quickly press the test/silence button on one of the 2 units 4 times; it will beep
once and the red LED will flash slowly, indicating it has entered pairing mode
and is waiting for a new unit to be added. Quickly press the test/silence button
on the other unit twice; it will beep once and the red LED will flash rapidly,
indicating it is searching for a device to connect to.
3. After the search is successful and an interconnected group is created, both
units will beep once and automatically exit the interconnection mode. At
this point, both units will only flash once 60 seconds, indicating they are in
normal standby mode.
4. If you want to connect a third alarm to this group, first activate a new
device according to its operating instructions and then quickly press the
test/silence button on either of the 2 previously interconnected units 4
times. This unit will beep once, and the red LED will flash slowly, indicating
it is ready to add a new device to the network. Next, quickly press the test/
silence button on the new unit twice, and the red LED will flash rapidly as it
searches for a network to connect to. After the third unit successfully joins
the interconnected network, both units will beep once and automatically
exit the interconnection mode.
5. If you want to connect more units, simply repeat step 4. Up to 24 alarms
can be interconnected this way. To ensure that all alarms enter the same
interlinked network, make sure you only work with 2 units at a time one
unit enters the pairing mode and the other unit enters the searching
mode.
6. Test the alarms according to the steps in the section“Alarm Test.”
NOTES
1. The alarm will enter the searching mode or the pairing mode for 60
seconds with the red LED ashing. After 60 seconds, repeat step 2 to
connect the alarms. If needed, press the test/silence button once while
the alarm is in the searching mode or the pairing mode, and the red
LED will stop ashing and the alarm will quit the pairing mode to enter
normal status.
RF
Quickly
press twice
Quickly
press twice
Quickly
press 4 times
Quickly
press 4 times
01 02
RF
Hold down
03 04

06 07
2. If you have purchased the old version of the XS01-WR alarms, you can
add X-Sense Link+wireless interlinked alarms into the existing XS01-WR
interconnected network.
1. To ensure that an X-Sense Link+wireless interlinked alarm successfully
connects to an X-Sense XS01-WR network, choose one of the previously
interconnected XS01-WR smoke alarms, remove it from the mounting
bracket, and keep this alarm at least 33 ft (10 m) away from the other
alarms in the existing network.
2. Turn on one X-Sense Link+wireless interlinked alarm according to its
operating instructions. Quickly press its test/silence button twice; the
alarm will beep once, and the LED will flash red rapidly as it searches for a
network to connect to. Next, quickly press the test/silence button 4 times
on the XS01-WR alarm that was removed from the mounting bracket; it
will beep once and the LED will flash red rapidly, indicating it is ready to
add a new device to the network.
3. After the two units successfully pair, both units will beep once and
automatically exit the interconnection mode. At this point, the X-Sense
Link+alarm has also joined the existing XS01-WR network. Both units will
only flash once per minute, indicating they are in normal standby mode.
4. If you want to connect more X-Sense Link+wireless interlinked alarms,
simply repeat step 1-2. Up to 24 alarms can be interconnected this way. To
ensure that all alarms enter the same interlinked network, make sure you
add X-Sense Link+wireless interlinked alarms one at a time.
5. Test the alarms according to the steps in the section“Alarm Test”.
2. Test all wireless alarms to ensure they are interconnected before
installation.
3. A maximum of 24 wireless alarms can be interconnected on the same
network.
4. The model can only be interconnected with other X-Sense Link+wireless
interlinked alarms.
How to Add X-Sense Link+Wireless Interlinked Alarms to the X-Sense
XS01-WR Network
The XS01-WR model has 2 versions: the old version, XS01-WR, and the
new version, X-Sense Link+XS01-WR, which have different interconnection
methods. The new version belongs to the X-Sense Link+series and there is
a“Link+” icon on the label on the back of the unit. Check whether the “Link+”
icon is on the label to distinguish between these 2 versions.
NOTES:
1. The following instructions for wireless interconnection are only
applicable to the old version of the X-Sense XS01-WR wireless interlinked
smoke alarms, not the X-Sense Link+wireless interlinked alarms.
New Version XS01-WR (X-Sense Link+Series)
Old Version XS01-WR

08 09
How to Disconnect
Quickly press the test/silence button 4 times; the smoke alarm will beep
once. Then, hold down the button until it beeps once more to disconnect.
After disconnecting, it can be reconnected to the same network, or added to
a new network.
NOTE: The X-Sense Link+wireless interlinked alarms in one multi-pack
have already been interconnected. To create a new network, you will rst
need to disconnect each alarm individually in this multi-pack to avoid
having them all join the same network.
Alarm Test
Be sure to test your smoke alarms when you turn them on for the first time,
or when the group configuration has changed. In addition to the weekly
tests you should perform, it is recommended to test the alarm after returning
from a long trip or vacation.
If your X-Sense Link+XS01-WR is interconnected to other wireless smoke
alarms, we recommend that every individual smoke alarm is tested during
the weekly test.
Test a single alarm Test all interconnected smoke alarms
Action Press the test/silence
button.
Hold down the test/silence button.

10 11
Indication • The alarm will sound
3 short quick beeps.
• The red LED will
flash once every
second during the
audible signal.
• After testing,
the alarm will
automatically
enter standby
mode.
• The initiating smoke alarm will
beep continuously with the red LED
flashing.
• Other interconnected smoke alarms
in the network will receive the
signal after 5 seconds, and they will
beep continuously with the red LED
flashing. Release the test/silence
button and all the smoke alarms will
stop testing.
• The testing of the units should be
completed within 3 minutes.
• After testing, the units will
automatically enter standby mode.
NOTE: The test function accurately tests the alarm’s smoke sensing circuit
without the need to test with smoke. If your smoke alarm fails to give an
audible test signal, please refer immediately to the troubleshooting guide
at the end of this manual. Never use an open ame to test this device.
Installation Positioning
NOTE: If a smoke alarm is installed in a kitchen, ensure it has an accessible
silence button, and install it as far away from the stove and sink as
possible to avoid false alarms.
Smoke Alarms Smoke & Carbon Monoxide Alarms
Fire Extinguishers
Carbon Monoxide Alarms

12 13
1. Prioritize the installation of an alarm in the bedroom and walkways, and
make sure you can hear the alarm from all sleeping areas. In a home with
several bedrooms, install an alarm in every bedroom. If you install only one
smoke alarm in your home, install the alarm near to all bedrooms where
possible, and not in a basement or furnace room.
2. Install an alarm above the stairway and on every floor of the house.
3. Smoke, heat and anything burning will spread horizontally after rising to
the ceiling, so install the alarm in the middle of the ceiling where possible.
Ensure that the alarm is installed at the minimum distance away from
corner.
4. If an alarm cannot be installed in the middle of a ceiling, install it at a
distance of 20 inches (50 cm) away from the corners of the room.
5. If an alarm is installed onto a wall, a distance of 4-12 inches (10-30 cm)
should be kept below the ceiling.
6. If the length of a room or hall is beyond 30 feet (900 cm), several alarms
should be installed in the same room.
7. When the wall or ceiling is angled, the alarm needs to be installed within 3
feet (90 cm) of the highest wall or ceiling point (measured horizontally) in
the room.
8. In multi-level houses or apartments, install at least one wireless smoke
alarm on each level and keep them installed in a straight vertical line
(see diagram) with as few obstacles between each of the interconnected
alarms as possible to ensure optimal signal transmission.

14 15
Locations to Avoid
1. Near large metal surfaces and/or bundles of wire.
2. Near fluorescent lights, amateur radios, electrical equipment, or other
devices that may transmit an RF signal, as electronic“noise”may cause
nuisance alarms.
WARNING
1. THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON.
2. ALARMS SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER
INSTALLATION, USE AND MAINTENANCE OF FUELBURNING APPLIANCES
INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.
Installation Method
NOTE: Before installation, it is recommended to test the interconnected
smoke alarms in dierent rooms where you intend to install these alarms
to ensure that they are within the transmission range.
1. Use the mounting bracket to mark the screw holes on the ceiling or the
wall.
2. Drill holes at the 2 marks using an appropriately-sized drill bit. Insert the
anchor plugs and screw the mounting bracket using the screws provided.
3. Attach the alarm to the mounting bracket and turn clockwise to lock the
alarm.
4. Test the smoke alarm according to the steps in the section “Alarm Test”.

16 17
Battery Replacement
1. To replace the battery, detach the smoke alarm from the mounting bracket
by twisting counterclockwise.
2. Pull the battery removal tab to remove the battery, and then install a new
battery, matching the correct polarity markings.
3. Test the alarm, and then mount the alarm onto the mounting bracket by
twisting clockwise to lock the alarm.
01 02
03 04

18 19
LED Indicator and Audible Alarm
Status LED indicator Audible alarm Note
Normal Red LED
flashes once
every 60
seconds.
None
Alarm Red LED
flashes once
every second.
Short quick
beeps
All alarms in the
interconnected
network
Test Single Smoke Alarm Red LED
flashes once
every
second.
3 short quick
beeps
Press the test/
silence button
once.
All interconnected
smoke alarms
in the network
Red LED
flashes once
every
second.
Continuous
beeping until
you release
the test/
silence
button
Hold down the
test/silence
button.
Silence Mode Red LED
flashes once
every 5
seconds.
None
Low Battery Red LED
flashes once
every 60
seconds.
1 beep every
60 seconds
Each alarm
gives an
independent
warning.
Malfunction Red LED
flashes
twice every
40 seconds.
2 beeps every
40 seconds
Each alarm
gives an
independent
warning.
Silence Mode
If you press the silence button during an alarm state, the unit will be in the
silence mode for 9 minutes. During the silence mode, the red LED will flash
once every 5 seconds. The alarm will enter the normal mode after 9 minutes.

20 21
NOTES
1. You can silence all interconnected units by pressing the test/silence
button on one of the units. If one unit is still alarming, it is the initiating
unit (the unit that detected danger); to silence all interlinked units, you
must also press the test/silence button on the initiating unit.
2. While interconnected, the initiating unit cannot be triggered again
during the 9-minute silence duration. However, all other interconnected
units can be triggered again if they detect danger during the silence
mode.
Technical Specications
Power Supply Replaceable 3 V CR123A lithium battery
Operating Life 10 years
Battery Life 5 years
Sensor Type Photoelectric
Safety Standard EN 14604:2005+AC:2008
Standby Current < 15 uA (avg.)
Alarm Current < 150 mA (avg.)
Coverage Area 215-430 ft2 (20-40 m2)
Best Operating Ambient
Temperature
40–100°F (4.4–37.8°C)
Operating Relative Humidity ≤ 85% (non-condensing)
Alarm Loudness ≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing
alarm
Silence Duration About 9 minutes
Operating Frequency 868 MHz
Maximum Number of
Interconnected Units
24 wireless units (only compatible with
X-Sense wireless alarms)
Transmission Range Over 820 ft (250 m) in open air
NOTES
1. Battery life is calculated on the current ratings in the standby mode with weekly
testings. If its operation mode changes to an alarming condition, the battery life
will be decreased accordingly.
2. The smoke alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged
exposure to temperatures outside of this range can reduce battery life and affect
accuracy. We do not recommend operating the device outside of this range.

22 23
Maintenance
To keep your smoke alarm in good working order, follow these simple steps:
1. Verify the unit’s alarm sound and indicator are working properly by testing
the unit once a week.
2. As a minimum your smoke alarm should be cleaned once every 3 months:
Remove the unit from the ceiling and clean the alarm cover and vents with
your vacuum cleaner fitted with the soft brush attachment to remove dust
and dirt.
3. Never use detergents or other solvents to clean the unit.
4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
5. Do not paint the unit. Paint will seal the vents and interfere with the
sensor’s ability to detect fire.
6. Never attempt to disassemble the unit or clean inside. Doing so will void
your warranty.
7. When removed, place the smoke alarm back in its proper location as soon
as possible, to assure continuous
protection from fire.
8. When household cleaning supplies or similar contaminants are used, the
area should be ventilated.
Troubleshooting
PROBLEM SOLUTION
Your smoke alarm does
not sound during testing.
• Make sure you push the test/silence button
firmly.
• Check the installation positioning. The wireless
signal might be blocked or out of range.
False alarms triggered
intermittently or when
residents are cooking,
taking showers, etc.
• Check the location of your smoke alarm (see
“Installation Positioning”).
• Clean the smoke alarm (see “Maintenance”).
Red LED flashes and the
alarm sounds one beep
every 60 seconds.
The battery is low. Replace the battery
immediately.
Red LED flashes and the
alarm sounds two beeps
every 40 seconds.
The alarm is malfunctioning. Please clean your
smoke alarm and see if it is working normally. If
not, replace the device immediately.

24 25
Environmental Protection
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with Local Authority or retailer for recycling advice.
Manufacturer and Service Information
X-Sense Innovations Co., Ltd.
Address: B4-503-D, Tower B, Kexing Science Park, No. 15 Keyuan
Road, Technology Park Community, Yuehai Avenue, Nanshan District,
Shenzhen, 518057, CHINA
Email: [email protected]
Deutsch
Diese Gebrauchsanweisung enthält wichtige Informationen zur Bedienung
Ihres X-Sense Rauchmelders. Vergewissern Sie sich, dass Sie diese
Gebrauchsanweisung vollständig gelesen haben, bevor Sie den Melder
installieren und in Betrieb nehmen. Wenn Sie diesen Rauchmelder zur
Verwendung durch andere installieren, müssen Sie dieses Handbuch (oder
eine Kopie davon) dem Endverbraucher überlassen.
Lieferumfang
1 × Alarm-Einheit 1 × Montagehalterung 2 × Schrauben
2 × Dübel 1 × Gebrauchsanweisung

26 27
Sicherheitshinweise
WICHTIG
1. GEFAHREN, WARNHINWEISE UND VORSICHTSHINWEISE WEISEN SIE
AUF WICHTIGE GEBRAUCHSANWEISUNGEN ODER AUF POTENZIELL
GEFÄHRLICHE SITUATIONEN HIN. ACHTEN SIE BESONDERS AUF DIESE
SACHVERHALTE.
2. DIESER MELDER IST NICHT DAZU BESTIMMT, HÖRGESCHÄDIGTE PERSONEN
ZU WARNEN. DER KONSUM VON ALKOHOL ODER DROGEN KANN DIE
HÖRBARKEIT DES RAUCHMELDERS EBENFALLS BEEINTRÄCHTIGEN.
3. BRÄNDE IN SCHORNSTEINEN, WÄNDEN, DÄCHERN, VERSCHIEDENEN
EBENEN ODER HINTER GESCHLOSSENEN TÜREN WERDEN
MÖGLICHERWEISE NICHT ERKANNT.
4. DIESES GERÄT ERKENNT KEINE FLAMMEN, HITZE, KOHLENMONOXID ODER
ANDERE GEFÄHRLICHE GASE.
WARNUNG
1. IGNORIEREN SIE NIEMALS EINEN ALARM. NICHTBEACHTUNG KANN ZU
SCHWEREN VERLETZUNGEN ODER ZUM TOD FÜHREN.
2. DIE STUMMSCHALTFUNKTION DIENT NUR IHRER BEQUEMLICHKEIT UND
WIRD EIN PROBLEM NICHT BEHEBEN. ÜBERPRÜFEN SIE IHR ZUHAUSE NACH
JEDEM ALARM IMMER AUF EIN MÖGLICHES PROBLEM. NICHTBEACHTUNG
KANN ZU VERLETZUNGEN ODER ZUM TOD FÜHREN.
3. TESTEN SIE DIESEN RAUCHMELDER EINMAL PRO WOCHE. SOLLTE JEMALS
EIN TESTFEHLER DES MELDERS VORLIEGEN, ERSETZEN SIE IHN SOFORT!
WENN DER MELDER NICHT EINWANDFREI FUNKTIONIERT, WARNT ER
MÖGLICHERWEISE NICHT VOR GEFAHREN.
Drahtlose Melder einrichten und vernetzen
Alle X-Sense Link+drahtlos vernetzte Melder enthalten ein eingebautes
HF-Modul, mit dem Sie 2 oder mehr Rauchmelder drahtlos verbinden und
ein vernetztes Netzwerk erstellen können. Wenn eine Einheit ausgelöst
wird, ertönen alle miteinander verbundenen Melder. Die X-Sense Link+
Serie enthält drahtlose miteinander verbundene Rauchmelder, drahtlose
miteinander verbundene Kohlenmonoxidmelder und drahtlose miteinander
verbundene Kombinierter Rauch- und Kohlenmonoxidmelder. Dieses
Modell ist so konzipiert, dass es drahtlos mit anderen X-Sense Link+
Melder verbunden ist und nicht für die Kommunikation mit miteinander
verbundenen drahtlosen Melder anderer Hersteller ausgelegt ist.
Die drahtlosen miteinander verbundenen Melder X-Sense Link+in
einem Multipack wurden bereits miteinander verbunden, und die
Melder in jedem Multipack verfügen über ein eigenes unabhängiges
miteinander verbundenes Netzwerk. Wenn Sie mehr als ein Multipack
haben, müssen Sie sie alle mit demselben Netzwerk verbinden. Wählen
Sie ein Multi-Pack als Basisnetzwerk und verbinden Sie die anderen
Multi-Packs damit.

28 29
HINWEIS! Die folgenden Anweisungen für die drahtlose Verbindung gelten
nur für die X-Sense Link+miteinander verbundenen Melder.
Wie man untereinander verbindet
1. Stellen Sie sicher, dass Sie nur mit 2 Einheiten gleichzeitig arbeiten, und
stellen Sie sicher, dass beide eingeschaltet sind, um eine erfolgreiche
Verbindung sicherzustellen.
HINWEIS: Um XS01-WR einzuschalten, entfernen Sie die Batterie-Isolierfolie
aus dem Batteriefach. Weitere Informationen zum Einschalten verschiedener
Modelle von drahtlos miteinander verbundenen Melder finden Sie in der
Bedienungsanleitung.
2. Drücken Sie schnell die Test-/Stummschalt-Taste auf eine der 2 Einheiten
4 Mal; es wird einmal piepen und die rote LED blinkt langsam, es zeigt an,
dass es ist in den Paarungsmodus gewechselt ist und wartet auf eine neu
hinzugefügte Einheit. Drücken Sie schnell die Test-/Stummschalt-Taste auf
der anderen Einheit zweimal; es wird einmal piepen und und die rote LED
blinkt schnell, es zeigt an, dass es ein Gerät zum Verbinden sucht.
3. Nachdem die Suche erfolgreich war, wird eine miteinander verbundene
Gruppe erstellt, beide Einheiten piepen einmal und verlassen automatisch
den Verbindungsmodus Zu diesem Zeitpunkt blinken beide Geräte
nur einmal 60 Sekunden und zeigen an, dass sie sich im normalen
Standby-Modus befinden.
4. Wenn Sie einen dritten Melder an diese Gruppe anschließen möchten,
aktivieren Sie zuerst ein neues Gerät gemäß der Bedienungsanleitung
und drücken Sie dann schnell die Test-/Stummschalt-Taste an einer der
beiden zuvor miteinander verbundenen Einheiten 4 Mal. Diese Einheit
piept einmal und die rote LED blinkt langsam und zeigt an, dass er bereit
ist, ein neues Gerät zum Netzwerk hinzuzufügen. Als nächstes drücken Sie
schnell die Test-/Stummschalt-Taste auf der neuen Einheit zweimal und
die rote LED blinkt schnell, da es nach einem Netzwerk sucht, um sich
zu verbinden. Nachdem die dritte Einheit erfolgreich dem miteinander
verbundenen Netzwerk beigetreten ist, piepen beide Einheiten einmal
und verlassen automatisch den Verbindungsmodus.
5. Wenn Sie weitere Einheiten anschließen möchten, wiederholen Sie einfach
Schritt 4. Bis zu 24 Melder können so miteinander verbunden werden. Um
sicherzustellen, dass alle Melder in dasselbe vernetzte Netzwerk gelangen,
stellen Sie sicher, dass Sie jeweils nur mit 2 Geräten arbeiten—eine Einheit
wechselt in den Paarungsmodus und die andere in den Suchmodus.
6. Testen Sie den Melder gemäß den Schritten im folgenden Abschnitt
"Meldertest".

30 31
HINWEISE
1. Der Melder wechselt für 60 Sekunden in den Suchmodus oder in den
Paarungsmodus, während dessen die rote LED blinkt. Wiederholen Sie
nach 60 Sekunden Schritt 2, um die Melder anzuschließen. Drücken Sie
bei Bedarf einmal die Test-/Stummschalt-Taste, während sich der Melder
im Suchmodus oder im Paarungsmodus befindet, und die rote LED hört
auf zu blinken und der Melder beendet den Paarungsmodus, um in den
Normalzustand zu gelangen.
2. Testen Sie alle Funk-Melder, um sicherzustellen, dass sie vor der Installation
miteinander verbunden sind.
3. Im selben Netzwerk können maximal 24 Funk-Melder miteinander
verbunden werden.
4. Das Modell kann nur mit anderen X-Sense Link+drahtlosen miteinander
verbundenen Melder verbunden werden.
So fügen Sie die X-Sense Link+drahtlose miteinander verbundenen
Melder in das X-Sense XS01-WR Netzwerk hinzu
Das Modell XS01-WR hat 2 Versionen: die alte Version XS01-WR und die neue
Version X-Sense Link+XS01-WR, die unterschiedliche Verbindungsmethoden
haben. Die neue Version gehört zur X-Sense Link+Serie und auf dem
Etikett auf der Rückseite des Geräts befindet sich ein Symbol "Link+" (siehe
folgenden Screenshot). Sie können überprüfen, ob sich auf dem Etikett ein
Symbol "Link+" befindet, um diese beiden Versionen zu unterscheiden.
Drücken Sie
schnell 2 Mal
Drücken Sie
schnell 2 Mal
Drücken Sie
schnell 4 Mal
Drücken Sie
schnell 4 Mal
01 02
Unten
halten
03 04
HF
HF
Alte Version XS01-WR Neue Version XS01-WR (X-Sense Link+Serie)

32 33
HINWEISE
1. Die folgenden Anweisungen für die drahtlose Vernetzung sind nur für die alte
Version der X-Sense XS01-WR drahtlose miteinander verbundene Rauchmelder,
die nicht zu X-Sense Link+drahtlose miteinander verbundenen Melder gehören.
2. Wenn Sie die alte Version XS01-WR Melder erworben haben, können Sie X-Sense
Link+drahtlose miteinander verbundene Melder in das zuvor miteinander
verbundene Netzwerk XS01-WR hinzufügen.
1. Um sicherzustellen, dass ein X-Sense Link+drahtloser miteinander
verbundene Melder erfolgreich eine Verbindung zu einem X-Sense
XS01-WR Netzwerk herstellt, wählen Sie einen der zuvor miteinander
verbundenen XS01-WR Rauchmelder aus, entfernen Sie ihn aus der
Halterung und halten Sie diesen Alarm mindestens 10 m von den anderen
Meldern im vorhandenen Netzwerk entfernt.
2. Schalten Sie einen X-Sense Link+drahtlos miteinander verbundenen
Melder gemäß der Bedienungsanleitung ein. Drücken Sie schnell die Test-/
Stummschalt-Taste zweimal, der Melder piept einmal, und die LED blinkt
schnell rot, das es ein Netzwerk zum Verbinden sucht. Als nächstes drücken
Sie schnell die Test-/Stummschalt-Taste auf einem der zuvor miteinander
verbundenen XS01-WR Melder 4 Mal; es piept einmal und die LED blinkt
schnell rot, es ist bereit, ein neues Gerät in das Netzwerk hinzuzufügen.
3. Nachdem die beiden Einheiten erfolgreich gepaart wurden, piepen beide
Einheiten einmal und verlassen automatisch den Verbindungsmodus.
Zu diesem Zeitpunkt ist der X-Sense Link+Melder auch dem bestehenden
XS01-WR Netzwerk beigetreten. Beide Geräte blinken nur einmal pro
Minute und zeigen an, dass sie sich im normalen Standby-Modus befinden.
4. Wenn Sie weitere X-Sense Link+drahtlose miteinander verbundene Melder
anschließen möchten, wiederholen Sie einfach Schritt 1-2. Bis zu 24 Melder
können so miteinander verbunden werden. Um sicherzustellen, dass
alle Melder in dasselbe vernetzte Netzwerk gelangen, stellen Sie sicher,
dass Sie X-Sense Link+drahtlose miteinander verbundene Melder einzeln
hinzufügen.
5. Testen Sie den Melder
gemäß den Schritten
im folgenden
Abschnitt "Meldertest".

34 35
Wie trennt man die Verbindung
Drücken Sie schnell 4 Mal die Test-/Stummschalt-Taste und der Rauchmelder
piept einmal, dann halten Sie die Taste gedrückt, bis es einmal piept, um es
zu trennen. Nach dem Trennen können Sie es erneut verbinden, damit es in
das vernetzte Netzwerk eintritt.
HINWEIS: Die drahtlosen miteinander verbundenen X-Sense Link+Melder
in einem Multipack wurden bereits miteinander verbunden. Um ein neues
Netzwerk zu erstellen, müssen Sie zuerst jeden Melder einzeln in diesem
Multipack trennen, um zu vermeiden, dass sie alle demselben Netzwerk
beitreten.
Meldertest
Testen Sie Ihre Rauchmelder unbedingt, wenn Sie sie zum ersten Mal
einschalten oder wenn sich die Gruppenkonfiguration geändert hat.
Zusätzlich zu den wöchentlichen Tests, die Sie durchführen sollten, wird
empfohlen, den Melder nach der Rückkehr von einer langen Reise oder
einem Urlaub zu testen.
Wenn Ihr X-Sense Link+XS01-WR mit anderen Funk-Rauchmeldern
verbunden ist, empfehlen wir Ihnen, jeden einzelnen Rauchmelder während
des wöchentlichen Tests zu testen.
Testen Sie einen
einzigen Melder
Testen Sie alle miteinander verbundenen
Rauchmelder
Aktion Drücken Sie die Test-/
Stummschalt-Taste.
Halten Sie die Test-/Stummschalt-Taste
gedrückt.
Indikation • Der Melder gibt
3 kurze schnelle
Pieptöne von sich.
• Die rote LED
blinkt während
des hörbaren
Signals einmal jede
Sekunde.
• Nach dem
Testen wechselt
der Melder
automatisch in den
Standby-Modus.
• Der initiierende Rauchmelder piept
kontinuierlich mit rot blinkender LED.
• Andere miteinander verbundene
Rauchmelder im Netzwerk empfangen
das Signal nach 5 Sekunden und
piepen kontinuierlich mit der rot
blinkender LED. Lasse die Test-/
Stummschalt-Taste los und alle
Rauchmelder hören auf zu testen.
• Der Alarmtest ist innerhalb von 3
Minuten abgeschlossen.
• Nach dem Testen wechselt der Melder
automatisch in den Standby-Modus.
HINWEIS: Die Testfunktion testet genau den Rauchmelderkreis des Melders ohne
die Notwendigkeit von Testrauch. Wenn Ihr Rauchmelder kein akustisches Testsignal
gibt, lesen Sie bitte am Ende dieser Bedienungsanleitung sofort die Anleitung zur
Fehlerbehebung.Verwenden Sie niemals eine offene Flamme, um dieses Gerät zu
testen.

36 37
Installationsort
HINWEIS: Wenn ein Rauchmelder in einer Küche installiert ist, stellen Sie
sicher, dass er über eine leicht zugängliche Stummschalt-Taste verfügt,
und installieren Sie den Melder so weit wie möglich vom Herd und der
Spüle entfernt, um Fehlalarme zu vermeiden.
1. Priorisieren Sie die Installation eines Rauchmelders im Schlafzimmer
und in den Gängen und stellen Sie sicher, dass Sie den Melder von
allen Schlafbereichen hören können. In einem Haus mit mehreren
Schlafzimmern, installieren Sie einen Melder in jedem Schlafzimmer.
Wenn Sie nur einen Rauchmelder in Ihrem Haus installieren, installieren Sie
den Melder möglichst in der Nähe aller Schlafzimmer und nicht in einem
Keller oder Ofenraum.
2. Installieren Sie einen Melder über der Treppe und auf jeder Etage des
Hauses.
3. Rauch, Hitze und alles, was brennt, breitet sich nach dem Aufsteigen an die
Decke horizontal aus, so dass der Melder nach Möglichkeit in der Mitte der
Decke installiert werden kann. Vergewissern Sie sich, dass sich der Melder
in Reichweite aller Ecken des Raumes befindet.
4. Wenn ein Melder nicht in der Mitte einer Decke installiert werden kann,
installieren Sie ihn in einem Abstand von 50 cm zu Raumecken.
5. Wird ein Melder an einer Wand installiert, sollte der Abstand zur Decke
10-30 cm betragen.
6. Wenn die Länge eines Raums oder einer Halle mehr als 900 cm beträgt,
ollten mehrere Melder im selben Raum installiert werden.
7. Wenn die Wand oder Decke geneigt ist, muss der Melder innerhalb 90 cm
vom höchsten Wand- oder Deckenpunkt (horizontal gemessen) im Raum
entfernt installiert werden.
Other manuals for XS01-WR
3
Table of contents
Languages:
Other x-sense Smoke Alarm manuals

x-sense
x-sense XS01-WR User manual

x-sense
x-sense XS01-WR User manual

x-sense
x-sense XS01-WT User manual

x-sense
x-sense XS03 User manual

x-sense
x-sense XP01 User manual

x-sense
x-sense SCO6-W User manual

x-sense
x-sense SD19-W User manual

x-sense
x-sense XS01-WT User manual

x-sense
x-sense SC03 User manual

x-sense
x-sense XS03 User manual

x-sense
x-sense XSO1-WX User manual

x-sense
x-sense XP04 User manual

x-sense
x-sense XP01 User manual

x-sense
x-sense SD19-W User manual

x-sense
x-sense XS01-W User manual

x-sense
x-sense XS01-WR User manual

x-sense
x-sense SC03 User manual

x-sense
x-sense XS01-W User manual

x-sense
x-sense XS01 User manual

x-sense
x-sense XP01 User manual