IM 12C07J01-01E
< 1. Specication >1-3
1.2 ModelandSuxcodes
lORP Sensor
Model SuxCode Option Code Description
OR8EFG ......................................... ................... KCl Filling Type ORP Sensor
Electrode -AU
-PT
...................
...................
Gold
Platinum
Cable Length
and KCl Tube
Length
-03
-05
-07
-10
-15
-20
...................
...................
...................
...................
...................
...................
3 m
5 m
7 m
10 m
15 m
20 m
KCl Reserve Tank (*1) -TT1
-TT2
-TN1
-TN2
...................
...................
...................
...................
For general purpose (250 mL solution inlet)
For medium pressure (*2)
For maintenance (for TT1)
For maintenance (for TT2)
Measuring System -N
-E
-F
-B
-G
...................
...................
...................
...................
...................
For OR200,OR400 (*3)
For FLXA402,PH202,FLXA202,FLXA21 (*4)
For FLXA202,FLXA21 (*5)
For OR100 (*6)
For FLXA402, PH450G,PH202/TB (*7)
Style *A ................... Style A
Option Special junction /TF PTFE junction (*8)
*1: 2-inch pipe mounting bracket is supplied with TT1, TT2.
Only a supply tube, but no KCl solution, is supplied with TN1 and TN2.
Since a KCl solution is not supplied with TT2, arrange it from among accessories or auxiliary parts.
*2: Prepare an air pressure regulator as shown in the diagram below when the medium-pressure reserve tank is used.
To ORP Sensor, Regulator, (to be prepared separately)
Air Supply
To ORP sensor
Regulator
(to be prepared separately)
*3: Mark band is shown by alphanumeric and fork terminals are used.
*4: Mark band is shown by numeral and pin terminals are used.
*5: Mark band is shown by numeral and M4 ring terminals are used.
When terminal box is used, select WTB10-PH5.
*6: The tag which indicated the color, the sign, and the number is attached to the cable of a sensor.
*7: Mark band is shown by numeral and M3 ring terminals are used.
When terminal box is used, select WTB10-PH3.
*8: Choose when using in the heavily contaminated application.
lAccessories
Model SuxCode Option Code Description
OR8AX ..................... ...................... Accessories for ORP meter (*1)
Style *A ...................... Style A
Option (*2) /STD
/KCLL
/KCLP
/TMP
Sensor stand (with mounting bracket for 2-inch pipe)
KCl solution (one 250 mL polyethylene bottle)
KCl powder (three bags, 250 mL solution each)
Thermometer (0 to 100°C)
*1: Including the following:
Two 200 mL polyethylene cups
One cleaning bottle
One pack of quinhydrone reagent powder (three bags, 250 mL solution each)
One 250 mL polyethylene bottle
*2: Either /KCLL or /KCLP is required for OR8EFG-¨¨-¨¨-TT2.
8th Edition : Apr. 27, 2020-00