manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Young
  6. •
  7. Measuring Instrument
  8. •
  9. Young 05631C User manual

Young 05631C User manual

Other Young Measuring Instrument manuals

Young Wind Sentry Series User manual

Young

Young Wind Sentry Series User manual

Young 32400 SERIAL INTERFACE User manual

Young

Young 32400 SERIAL INTERFACE User manual

Young 81000 Reference manual

Young

Young 81000 Reference manual

Young 81000V User manual

Young

Young 81000V User manual

Young 86000-SDI User manual

Young

Young 86000-SDI User manual

Young Wind Sentry 03002V User manual

Young

Young Wind Sentry 03002V User manual

Young ResponseONE 91000 User manual

Young

Young ResponseONE 91000 User manual

Young 86004 User manual

Young

Young 86004 User manual

Young 27106T User manual

Young

Young 27106T User manual

Young 81005A User manual

Young

Young 81005A User manual

Young 86004-SDI User manual

Young

Young 86004-SDI User manual

Young 03102L User manual

Young

Young 03102L User manual

Young 06201 User manual

Young

Young 06201 User manual

Young 06201 User manual

Young

Young 06201 User manual

Young 09101 User manual

Young

Young 09101 User manual

Young 27106 User manual

Young

Young 27106 User manual

Young 03002L User manual

Young

Young 03002L User manual

Young 85000 User manual

Young

Young 85000 User manual

Young WIND MONITOR-AQ 05305 User manual

Young

Young WIND MONITOR-AQ 05305 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTRUCTION SHEET 05631C-90
REV: B051311
MODEL 05631C
WIND LINE DRIVER
SPECIFICATIONS
Wind Speed Input: YOUNG Wind Monitor series of sensors
AC sine wave, Frequency proportional
to wind speed. 3 pulses per revolution.
Input sensitivity nom. 40 mV p-p
Wind Direction Input: Analog voltage from azimuth
potentiometer. Regulated excitation
voltage is supplied from interface circuit
to potentiometer.
Wind Speed Output: 4 to 20 mA = 0-100 M/S
Wind Direction Output: 4 to 20 mA = 0 to 360°
Overall accuracy: ± 1% of full scale over temperature and
supply voltage range
Dimensions: 110 mm W x 75 mm H x 56 mm D
(4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe
25-50mm (1-2 in) Diameter
Power Requirement: 12-30 VDC
Temperature Range: -50 to 50°C (-58 to 122°F)
INTRODUCTION
The Wind Line Driver converts raw signals from the wind sensors to
proportional 4 to 20 mA current loop values. The Line Driver acts like
a variable resistance that draws 4 - 20 mA when powered with 12 to
30 VDC. Although it has only one PC board, the Line Driver contains
two completely independent circuits - one for wind speed and the
other for wind direction. See wiring diagram below.
IMPORTANT!
The Wind Line Driver provides a calibrated current signal
for wind speed and wind direction. Externally connected
devices should be reviewed for compatibility and correct
signal scaling.
Repairs should be attempted only by qualied service personnel.
Declaration of Conformity
R. M. Young Company
2801 Aero Park Drive
Traverse City, MI 49686 USA
Model 05631C Wind Line Driver
The undersigned hereby declares on behalf of R. M.
Young Company that the above-referenced product, to
which this declaration relates, is in conformity with the
provisions of:
Council Directive 2004/108/EC (December 15, 2004)
on Electromagnetic Compatibility
David Poinsett
R&D Manager
WARRANTY
This product is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial purchase.
Liability is limited to repair or replacement of defective item. A copy
of the warranty policy may be obtained from R. M. Young Company.
CE COMPLIANCE
This product has been tested and shown to comply with European
CE requirements for the EMC Directive. Please note that shielded
cable must be used.
CALIBRATION FORMULAS
WIND SPEED vs mA OUTPUT
m/s = ( 6.250 x mA)-25
knots = (12.149 x mA)-48.6
mph = (13.980 x mA)-56
km/h = (22.500 x mA)-90
WIND DIRECTION vs mA OUTPUT
DEGREES = (22.5 x mA)-90
R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A.