logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3M
  6. •
  7. Water Filtration System
  8. •
  9. 3M Aqua-Pure APUN101 User manual

3M Aqua-Pure APUN101 User manual

This manual suits for next models

1

Other 3M Water Filtration System manuals

3M SGLP-CL Series User manual

3M

3M SGLP-CL Series User manual

3M VB2/HC111-S Quick guide

3M

3M VB2/HC111-S Quick guide

3M CFS717 Manual

3M

3M CFS717 Manual

3M 3MPF101 User manual

3M

3M 3MPF101 User manual

3M CFS22B 1.0 User manual

3M

3M CFS22B 1.0 User manual

3M Triple Manifold Water Filtration Systems User manual

3M

3M Triple Manifold Water Filtration Systems User manual

3M CS-451 Quick guide

3M

3M CS-451 Quick guide

3M AQUA-PURE IL-IM-01 User manual

3M

3M AQUA-PURE IL-IM-01 User manual

3M Aqua-Pure AP717 User manual

3M

3M Aqua-Pure AP717 User manual

3M 6000 User manual

3M

3M 6000 User manual

3M ScaleGard HP User manual

3M

3M ScaleGard HP User manual

3M Filtrete Standard User manual

3M

3M Filtrete Standard User manual

3M ScaleGard HP User manual

3M

3M ScaleGard HP User manual

3M 3MDW201 User guide

3M

3M 3MDW201 User guide

3M SGLP-RO User manual

3M

3M SGLP-RO User manual

3M 5000 Series User manual

3M

3M 5000 Series User manual

3M 6051i User manual

3M

3M 6051i User manual

3M SGLP100-CL User manual

3M

3M SGLP100-CL User manual

3M Aqua-Pure AP801B User manual

3M

3M Aqua-Pure AP801B User manual

3M CFS101BWF User manual

3M

3M CFS101BWF User manual

3M 6000 User manual

3M

3M 6000 User manual

3M Filtrete 4WH-QS-S01 User manual

3M

3M Filtrete 4WH-QS-S01 User manual

3M 3MPF201 User manual

3M

3M 3MPF201 User manual

3M HF05-MS User manual

3M

3M HF05-MS User manual

Popular Water Filtration System manuals by other brands

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

FLTR OBF user manual

FLTR

FLTR OBF user manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

HEISSNER FPU24000-00 Instructions for use

HEISSNER

HEISSNER FPU24000-00 Instructions for use

BGS technic 1518 instruction manual

BGS technic

BGS technic 1518 instruction manual

Reverse Osmosis RF Series user manual

Reverse Osmosis

Reverse Osmosis RF Series user manual

ubbink Filtramax Series manual

ubbink

ubbink Filtramax Series manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

At a Glance:
• Helps prevent blue/green stains on fixtures
• Aids in protecting copper plumbing systems
Application:
• Raises pH of Acidic Water
Product Benefits:
• Calcium carbonate media helps neutralize acidic water (pH levels below 6.7) by
raising the pH
- Helps inhibit corrosion of copper pipes and lead solder joints
- Helps prevent blue/green stains and pitted fixtures caused by corrosion
• The upflow system design helps reduce backwashing that is required for
continuous operation
• The patented fiberglass reinforced tank includes a non-corrosive, long lasting
design
• The translucent tank helps provide a convenient method to view the media bed level
• Fill-port included for easier media fills and additions
Models:
APUN101 / APUN201
Acid Neutralizers
Spec #
Quantity
APUN101
Limited Warranty Information:
CUNO Incorporated (“CUNO”) warrants this Aqua-Pure Water Treatment Product (“Product”) to be free from defects in
material and workmanship during normal residential use for one year on the entire product. This warranty does not apply to
failures that result from abuse, misuse, alteration or damage not caused by CUNO or failure to properly follow installation
and use instructions. This warranty does not apply to media and/or media replacement. Please refer to the Warranty Card
provided with the product for additional warranty details.
a 3M company
CUNO Incorporated
400 Research Parkway
Meriden, CT 06450 U.S.A.
Toll Free: 1.800.222.7880
Worldwide: 203.237.5541
Fax: 203.238.8701
www.aquapure.com • www.cuno.com
3M is a trademark of 3M Company.
CUNO and Aqua-Pure are trademarks of 3M Company used under license.
© 2009 3M Company. All rights reserved.
70-0202-3365-9
LITAPUN 0609
Spec #
Quantity
Model Number
Part Number
Distributed by:
May be covered by one or more of the following U.S. Patents: 5,890,750; 5,699,930; 5,584,411
Product Specifications:
Model
Inlet/
Outlet
Size
Dimensions Approximate
Weight
Maximum
Flow Rate
Maximum
Water
Temperature
Max. Water
Pressure
Media
Cu. Ft.
Standard
Media
Height Max.
Diameter
APUN101 1” NPT 52”
(133 cm)
10”
(26 cm)
133 lbs.
(61.3 kg)
5 gpm
(18.9 lpm)
100°F
(38° C)
125 psi
(861.8 kPa) 1.0 C
APUN201 1” NPT 62”
(158 cm)
12”
(31 cm)
245 lbs.
(111.2 kg)
7 gpm
(26.5 lpm)
100°F
(38° C)
125 psi
(861.8 kPa) 1.0 C
The Aqua-Pure Model APUN helps prevent corrosion of copper pipes and
plumbing fixtures by effectively raising low pH (acidic) water conditions.
The APUN directs the acidic water through a special limestone media
bed. The acidic water is neutralized as it slowly dissolves the media, thus
automatically raising the pH level.
The design of the APUN, which draws water upward through the media
bed, greatly reduces the potential caking of the media. The simplicity of
the upflow design requires no electricity, backwashing or a drain, making
the APUN Series a simpler, more effective and economical solution for
acidic water.
Easy Installation:
WaterMeter
Public
Water
Supply
Well
Water
Supply
PressureTank
Well
Supply
Only
Pump
Bathroom Kitchen
Utility Room
Media Material Application
C Calcium Carbonate Neutralization of moderately acidic water to 6.0 pH
N Special Blend Media Neutralization of highly acidic water below 6.0 pH
Maintenance*
The filter media requires periodic replenishment depending on the amount of water
used and the degree of acidity. The neutralizer should be checked every 3-6 months
to make sure that one-half to two-thirds of the media remains. The fill-port located
on the top of the tank permits simple replenishment of the “sacrificial” media.
The “C” or “N” Media helps to prevent the corrosion of copper pipes and plumbing
fixtures by raising low pH (acidic) water conditions. This process is similar to
adding lime to acidic soil or taking an antacid. “C” Media is used for moderate pH
levels (6.0-6.8). “N” Media, which dissolves more rapidly, is used for more extreme
conditions (pH 5.5-6.0 and as low as 5.0 under certain conditions). Both types of
media are consumed during neutralization and must be replenished periodically.
The “N” or “C” Media is available in one cu. ft. cartons for periodic replenishment.
The neutralizing media will help to increase the hardness level, along with the pH
level in the treated water. Under higher hardness conditions, a water softener or
a scale stopper filter is recommended for post-treatment to soften the water or
protect the hot water system.
* The maintenance and installation information contained on this she is for informational
purposes only. Complete installation and maintenance instructions are provided in the
Installation and Operation manual included with the system.
Product Specifications: Media Options:
K
itchen
The APUN is easily installed on cold
water lines only. It should be installed
after the pressure tank and prior to any
water treatment device.
A boiler drain is provided for flushing the
neutralizer after installation and media
replenishment.