Table of Contents
Safety Information.......................................................................................................................................2
Warning Statements ....................................................................................................................................2
Caution/Important Notes..............................................................................................................................3
DF Manifolds and Systems ..........................................................................................................................3
Inlet and Outlet Connections........................................................................................................................3
Product Dimensions.....................................................................................................................................4
How to Use “Push-in” Connectors................................................................................................................4
How to Use “Inlet/Outlet” Fitting Retention Clips...........................................................................................4
Equipment Installation .................................................................................................................................5
Equipment Start-up Procedure ....................................................................................................................6
Cartridge Change-out Procedure..................................................................................................................6
Troubleshooting ...........................................................................................................................................6
Parts Listing ................................................................................................................................................7
Warranty......................................................................................................................................................8
SAFETY INFORMATION
Read, understand, and follow all safety information contained in these instructions prior to installation. Retain
these instructions for future reference.
Intended Use:
The DF series manifolds and water filtration systems are intended for use in filtering potable water in the
foodservice industry and have not been evaluated for other uses. These systems are installed at the point of use and
must be installed as specified in the installation instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could result in death or
serious injury and/or property damage.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury and/or property damage.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
WARNING
To reduce the risk associated with choking:
•Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric
wiring or water pipes in the area of installation:
•Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the
position to mount the filter bracket.
To reduce the risk of physical injury:
•Depressurizesystemasshowninmanualpriortocartridgeremoval.
To reduce the risk associated with back strain:
•Followsafeliftingprocedures.
2

IMPORTANT NOTES
•Failuretofollowinstructionswillvoidwarranty.
•Allowaminimumof3”(7.6cm)clearspaceunderltertofacilitatecartridgechange.
•Installwiththeinletandoutletportsaslabeled.Makesurenottoreverseconnections.
•Somelocalcodesmayrequiretheuseofalicensedplumberorcertiedinstallerwhendisruptingapotablewater
line.
3
DF Manifolds and Systems
DualFlow(DF)manifoldsandltrationsystemshelpprovideconsistenthighqualitywaterformultipleapplications.
The inlet water enters the manifolds on the left rear side and flows separately through two different cartridge filters.
The two filters have different connection fittings that interconnect with the heads on the manifold.
The left-side single cartridge is the same for both DF1XX and DF2XX manifolds. The model number is HF90-S-SR5.
This is the only cartridge filter that will fit into the left-side head in either the DF1XX or the DF2XX manifold. The
media in this cartridge is a pleated nylon membrane with a scale inhibitor. It is used for water to ice machines. The
ice filter will not fit into the right-side head or heads. The filtered water with the scale inhibitor exits the manifold on
the left side front, and a label on the manifold designates this as “Outlet Ice/Coffee”.
When using the DF1XX manifold, there is one right-side filter. When using the DF2XX manifold, there are two right-
side cartridge filters in parallel. These filters typically supply the cold beverage application. The interconnect for
these filters is different than the interconnect for the left-side filter. The beverage filters will not fit into the left-side
head. The filtered water from these right-side second filters exits on the right side front, and a label on the manifold
designates this as “Outlet Beverage”.
The capacity of the beverage cartridge filters is equal to the combined flow rate and chlorine capacity ratings for the
numberofcartridgeltersusedinthemanifoldforthatapplication(oneortwo).Thus,fortwobeveragecartridges
each with a 54,000 gallon chlorine capacity at 5gal/min, the capacity for the beverage application is 108,000
gallons at 10 gal/min. For the single left-side ice-machine cartridge, the capacity is not assigned by chlorine
capacity but by particulate and scale-inhibitor capacity. It should be changed at the same time as the one or two
right-side beverage cartridge filters.
Inlet and Outlet Connections
The water inlet is on the left side rear and the outlets are on both sides and are identified with labels. The fitting
sizeis3/4”NPT(Male).Built-incheckvalves(non-return)areincorporatedintobothoutlets.
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow all Instructions before installation and use of this system.
•InstallationandUseMUST comply with all state and local plumbing codes.
•Protect from freezing, remove filter cartridge when temperatures are expected to drop below40°F(4.4°C);
• Do not install on hot water supply lines. The maximum operating water temperature of this filter system is
100°F(37.8°C).
•Do not installifwaterpressureexceeds125psi(862kPa).Ifyourwaterpressureexceeds80psi(552kPa),
you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check
your water pressure.
•Do not install where water hammer conditions may occur. If water hammer conditions exist, you must
install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this
condition.
•Anynon-metallicttingsusedintheinstallationsmustbeofadequateratingforthelinepressure.
•Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic
plumbing.
•Onplasticttings,neverusepipesealantorpipedope.UsePTFEthreadtapeonly, pipe dope properties may
deteriorate plastic.
•Takecarewhenusingpliersorpipewrenchestotightenplasticttings,asdamagemayoccurifovertight--
ening occurs.
•Do not install in direct sunlight or outdoors.
•Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount
the bracket.
•Mountlterinsuchapositionastopreventitfrombeingstruckbyotheritemsusedintheareaofinstallation.
•Ensurethatthelocationandfastenerswillsupporttheweightofthesystemwheninstalledandfullofwater.
•Ensureallconnectionsaresecureandfreeofleaks.
•Thedisposableltercartridge(s)MUST be replaced every 12 months or at the rated capacity or if a noticeable
reduction in flow rate occurs.

Product Dimensions
Step 2 Step 3 Step 4
Step 1
This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system
without tools. Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab interlaces
with windows in the manifold head near each connection port. Clip is flexible and easily assembled following these
instruction and illustrations.
1. Insert fitting into manifold.
2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window
3. Push center tab into center window.
4. Finally push top tab into top window.
How to Use the Inlet/Outlet Fitting Retention Clips
This product is outfitted with a user friendly ‘Push In’ connector at the vent valve. Proper use of the connectors is
shown in the figure below. It is most important that the tubing selected for use with these connectors be of high
quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use
a plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a "Push-In" con-
nector, the cause is usually defective tubing.
To Fix:
1. Relieve pressure 2. Release tubing 3. Cut off at least 1/4” from end
4. Reattach tubing 5. Confirm connection is leak free
How to Use “Push-in” Connectors
4
5 3/8"
(13.7 cm)
24 1/16"
(61.1 cm)
22 7/8"
(58.10 cm)
Minimum of 3" (7.6 cm)
For Cartridge Change
16 7/8"
(42.9 cm)
5 1/8"
(13.0 cm)
24 1/16"
(61.1 cm)
Minimum of 3" (7.6 cm)
For Cartridge Change
DF1 DF2
1
122
To Release Tubing
To Attach Tubing
Push tubing straight in as far
as it will go.
Tubing is secured in. Push in collt to release tubing. Pull tubing straight out.

CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read, understand, and follow all safety information contained on pages 2-4 prior to installation and
use of this product.
Equipment Installation
IMPORTANT NOTES
•Failuretofollowinstructionswillvoidwarranty.
•Allowaminimumof3”(7.6cm)clearspaceunderltertofacilitatecartridgechange.
•Installwiththeinletandoutletportsaslabeled.Makesurenottoreverseconnections.
DF Series manifolds may be used with metal or non-metallic piping systems.
1. Shut off incoming cold water supply.
2. Selecttheinstallationlocation.Allowaminimumof3in(7.6cm)ofspacebelowthecartridgefor
change-outs.
3. Selectfasteners(notincluded)andtoolsappropriatefortheinstallationlocation(wall,supportstructure
mountedtowallstuds,concrete,etc.)
4. Mount the manifold/filter system to a wall or using the mounting holes provided on the back plate of the metal
bracket.
•Itisrecommendedtorstdrawalevellineonthemountingsurfaceattheheightofthefasteners.
•Markthelocationofthefastenersusingthebracketasatemplateorbymeasuringthedistancebetweenthe
mounting holes.
•Installthefastenersandallow1/4”-3/8”(6-10mm)ofeachfastenertoprotrudefromthesurface.
•Installthemanifoldontothefasteners.
•Tightenthefasteners.
5. Installinlet(leftrear)andtwooutletttings(rightfrontandleftfront)tothemanifold.Allconnectionsterminate
witha¾”NPT(male)tting.Theinletkitincludesthettingandaballvalve.Thetwooutletsarethetting
only.Theinstructionsfortheretentionclipsareonpage4.(PTFEtapeisnotincluded.).
6. Remove the sanitary cap from the HF90-S-SR5 cartridge and apply a light coat of water or water-grade
lubricant to the o-rings.
7. AlignthetabsoftheHF90-S-SR5cartridgewiththeslotsintheretainingplateoftheheadontheleft-hand
side of the manifold, and insert the cartridge into the manifold. Turn the cartridge to the right until a clicking
soundisheard;theclickingsoundindicatesthecartridgeisproperlyengaged.
8. RepeatSteps6and7forthebeveragecartridges(DF1XXhasone,DF2XXhastwo)ontotheright-handhead(s)
ofthemanifold.IMPORTANTNOTE:Thebeveragecartridge(s)willnottintotheleft-handheadofthemanifold.
Theirconnectiononlymatchesthehead(s)ontheright-handsideofthemanifold.
Equipment Start-up Procedure
1. Turn on incoming water to system.
2. Pressurizesystembyrotatingtheinletballvalvehandle1/4turntotheleft(counterclockwise)
ON position.
3. Check for leaks.
4. Use vent valve to remove trapped air.
5. Flush system in accordance with the cartridge Performance Data Sheet.
5

No water flow through system Inlet valve closed
Cartridges clogged
Check shut-off valve position
Replace cartridges
Not enough water to the
downsteamapplication(s)
Low incoming water pressure
Cartridges clogged
Check source
Replace cartridges
Short filter life Temporarily dirty water Change cartridges or install an
additional upstream prefilter
Cartridge Change-out Procedure
CAUTION
To reduce the risk associated with property damage due to water leakage:
•ThedisposableltercartridgeMUST be replaced every 12 months or at the rated capacity or if a noticeable
reduction in flow rate occurs.
Cartridges will need to be changed every 6-12 months or when low pressure is indicated on the manifold’s pressure
gauge, whichever occurs first. Depending on local water quality, you may need to change the cartridges prior to the
recommended change-out. The loss of flow to carbonators or improper fill at the ice maker are also indicators that
the cartridges will need to be replaced.
1. Shut-offtheinletwaterbyrotatingtheshut-offvalve1/4turntotheright(clockwise)OFFposition..
2 Depressurize system.
3. Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left.
4. Using both hands and holding the cartridge from the bottom, rotate the cartridge a quarter turn to the left and
gentlypulldown.NOTE:Asmallamountofwaterwilldrainfrommanifoldascartridgeisremoved.
5. Remove sanitary cap from new cartridge. Install cartridge with a quarter turn to the right until cartridge comes
to a complete stop. NOTE: Cartridges are keyed to fit proper location only.
IMPORTANT NOTE:
Theicecartridge(HF90-S-SR5)willonlytintotheheadontheleftsideofthemanifoldandthebeverage
cartridgeswillonlytintothehead(s)ontherightsideofthemanifold.
6. Slowlyturntheinletwatervalve1/4turntotheleft(counterclockwise)ONpositionandcheckforleaks.
7. Flush per the cartridge Performance Data Sheet. System is now ready for use.
6
Troubleshooting

Item Part no. Description Qty* Function
1a 6228501 DF1xx Manifold 1 Assembly,complete
1b 6228401 DF2xx Manifold 1 Assembly,complete
2 60-2333700 Vent Valve 1 Release trapped air
3a 5617107 HF90-S-SR5 Cartridge 1 Water for ice
3b See catalog ReplacementCartridge(2) 1-2 Water for beverage
4 8500549 Pressure gauge 1 Monitor outlet water pressure
5 85-8528 Clip 1 Retain inlet/outlet fittings
6 63597320 o-ring 1 Seal inlet/outlet fittings
7 6220505 Inlet fitting kit –left rear 1 Inlet fitting with ball valve
8 6220506 Outlet fitting kit – right & left
front
1 Outlet fitting
9 60-235380 ¾” x ¾” ball valve 1 Inlet water shut-off
10 5617501 Retainer kit 1 Secure cartridges
Replacement Parts Listing
7
*Per part number, not per system or assembly.
a
a
Front —
Outlet to Ice/Coffee
Outlet to Beverage
Rear — Inlet
b
b
Rear — Inlet
Front —
Outlet to Ice/Coffee
Outlet to Beverage
DF1
DF2

3M is a trademark of 3M Company.
©20123MCompany.Allrightsreserved.
INSTR4327 0812B
PleaseRecycle.PrintedinU.S.A.
3M Purification Inc.
400 Research Parkway
Meriden,CT06450,USA
Toll Free: 866.990.9785
Worldwide: 203.237.5541
Fax: 203.238.8701
www.3Mfoodservice.com
www.3Mpurification.com
3M Purification Inc. warrants DF1XX and DF2XX High Flow Series water filtration systems only to be free from defects in material
andworkmanshipforone(1)yearfromthedateofpurchase.Thedisposableltercartridgeiswarrantedfromdefectsinmaterial
andworkmanshipforaperiodofone(1)yearfromthedateofpurchase.Thiswarrantydoesnotcoverfailuresresultingfromabuse,
misuse, alterations or damage not caused by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is
given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and consumption. 3M PU-
RIFICATION INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED
WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE. If the Product fails to
satisfy this Limited Warranty during the warranty period, 3M Purification Inc., at it’s option, will replace the Product or refund your
Product purchase price. This warranty does not cover labor. The remedy stated in this paragraph is Customer’s sole remedy
and 3M Purification Inc.’s exclusive obligation.
This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country.
For any warranty questions, please call 866.990.9785 or mail your request to: Warranty Claims, 3M Purification Inc., 400 Research
Parkway,Meriden,CT06450.Proofofpurchase(originalsalesreceipt)mustaccompanythewarrantyclaim,alongwithacomplete
description of the Product, model number and alleged defect.
Limitation of Liability: 3M Purification Inc. will not be liable for any loss or damage arising from this 3M Purification Inc. product,
whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract,
negligence or strict liability. Some states and countries do not allow the exclusion or limitation of incidental or consequential dam-
ages, so the above limitation or exclusion may not apply to you.
Limited Warranty
This manual suits for next models
1
Table of contents
Other 3M Water Filtration System manuals

3M
3M Filtrete 4WH-QS-S01 User manual

3M
3M DF1 Series User manual

3M
3M Aqua-Pure AP902 User manual

3M
3M Aircare ACU-03 User manual

3M
3M Aqua-Pure AP801 Housing Supplement

3M
3M 5000 Series User manual

3M
3M Aqua-Pure AP717 User manual

3M
3M DIDF260-CL Owner's manual

3M
3M ScaleGard HP Reverse Osmosis System User manual

3M
3M 6000 User manual