- 5 -
EN
The labels on the inverter and on battery unit have the Agency marking, main technical data and identification of the equipment and manufacturer
A4 1:1 1/1 XLP.V31xx.0AL
A.Statuti
G.Iannuzzi
A.Becattini
Pantone
Process Cyan C Process Yellow C
LABEL MATERIAL: 3M type 7331 (UL R/C, PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 105 mm (height) x 90 mm (width)
S.Bindi
DRAFT
V
dc max
I
dc max
V
dc Operating Range
V
dc MPP
I
sc max
V
acr
f
r
I
ac max
P
acr (cos = ±0.9)φ
V
acr
f
r
S
acr
I
ac max
MODEL:
REACT2-UNO-3.6-TL
575 V
90 - 575 V
2 x 12 A
160 - 480 V
2 x 15 A
Made in Italy
PROTECTIVE CLASS: I
230 V 1Ø
50 Hz
3200 W
3600 W
16 A
INVERTERSOLAR
www.abb.com/solar
PROTECTIVE
EARTHING
REQUIRED
230 V 1Ø
50 Hz
3000 VA
13 A
Regulatory Label of REACT2-UNO-3.6-TL
Adj. cosφ
P
acr (cos = 1)
φ
P
ac max
IP65
5 minutes
-20 to + 55 °C
-4 to +131 °F
BACKUP OUTPUT
(1): Over/Under excited
0.1-1
(1)
31/07/2018
31/07/2018
31/07/2018
31/07/2018
BATTERY PORT
V
dc Operating Range
170 - 575 V
I
dc max (charge)
13.5 A
I
dc max (discharge)
10 A
S
max
3600 VA
All material used and finished product, must meet the requirements of the current RoHS rective
i
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2018 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
e
e
e
a
A4 1:1 1/1 XLP.V31xx.0AL
A.Statuti
G.Iannuzzi
A.Becattini
Pantone
Process Cyan C Process Yellow C
LABEL MATERIAL: 3M type 7331 (UL R/C, PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 105 mm (height) x 90 mm (width)
S.Bindi
DRAFT
V
dc max
I
dc max
V
dc Operating Range
V
dc MPP
I
sc max
V
acr
f
r
I
ac max
P
acr (cos = ±0.9)φ
V
acr
f
r
S
acr
I
ac max
MODEL:
REACT2-UNO-5.0-TL
575 V
90 - 575 V
2 x 13.5 A
195 - 480 V
2 x 15 A
Made in Italy
PROTECTIVE CLASS: I
230 V 1Ø
50 Hz
4500 W
5000 W
22 A
INVERTERSOLAR
www.abb.com/solar
PROTECTIVE
EARTHING
REQUIRED
230 V 1Ø
50 Hz
3000 VA
13 A
Regulatory Label of REACT2-UNO-5.0-TL
Adj. cosφ
P
acr (cos = 1)
φ
P
ac max
IP65
5 minutes
-20 to + 55 °C
-4 to +131 °F
BACKUP OUTPUT
(1): Over/Under excited
0.1-1
(1)
31/07/2018
31/07/2018
31/07/2018
31/07/2018
BATTERY PORT
V
dc Operating Range
170 - 575 V
I
dc max (charge)
13.5 A
I
dc max (discharge)
14 A
S
max
5000 VA
All material used and finished product, must meet the requirements of the current RoHS rective
i
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2018 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
e
e
e
a
A4 1:1 1/1
Regulatory Label for MODEL REACT2-BATT
AA
Pantone
300 C Process Yellow C
LABEL MATERIAL: 3M type 7331 (UL R/C, PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 125 mm (height) x 80 mm (width)
I
dc max (charge)
4.5 A
Contains Rechargeable Li-ion Battery
- Refer to instruction manual for proper installation.
- Do not remove the cover. No user serviceable parts inside.
- Do not expose the unit to heating sources.
- Do not expose the unit to direct solar irradiation.
- Do not install or operate the unit in potentially explosive
s.atmosphere
WARNING!
www.abb.com/solar
BATTERY UNIT REACT2-BATTMODEL:
PROTECTIVE CLASS: I
Made in Italy
IP54
-20 55 (*)to + °C
-4 31 (*)to +1 °F
XLP.V31xx.0AL
A.Statuti
G.Iannuzzi
A.Becattini
S.Bindi
30/07/2018
30/07/2018
30/07/2018
30/07/2018
V
dc max
575 V
W
hr
4.0 kWh
I
dc max (discharge)
5.6 A
V
dc operating range
170 - 575 V
(*): Out of 0 to +40 °C (+32 to +104 °F) temperature range,power derating occurs
All material used and finished product, must meet the requirements of the current RoHS rective
i
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2018 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
a
e
MODEL NAME
POWER-ONE ITALY S.p.A
Via S.Giorgio 642, Terranuova Bracciolini (AR), 52028, Italia
P/N:PPPPPPPPPPP
WO:XXXXXXX
SO:SXXXXXXXX Q1
SN:YYWWSSSSSS WK:WWYY
a
b
c d
SN WLAN: SSSSSSSSSS
PN WLAN: PPP.PPPPP.PP
MAC: XX:XX:XX:XX:XX:XX
SN Inverter: SSSSSSSSSS
MAC: XX:XX:XX:XX:XX:XX
PK: KKKK-KKKK-KKKK-KKKK
Remove and apply
on the Quick
installaon guide
f
g
h
i
aInverter/battery model
bInverter/battery Part Number
cInverter/battery Serial Number
dWeek/Year of manufacture
eMain technical data
fWLAN embedded board Serial Number
gWLAN embedded board Part Number
hMAC address
iProduct Key
The labels attached to the equipment must NOT be removed, damaged, dirtied, hidden,etc...
If the Admin Plus password is requested, the field to be used is the serial number -SN: YYWWSSSSSS-
In the manual and/or in some cases on the equipment, the danger or hazard zones are indicated with signs, labels, symbols or icons.
Always refer to instruction manual General warning - Important safety
information Hazardous voltage
IP65
Protection rating of equipment
Temperature range Without isolation transformer
Positive pole and negative pole of
the input voltage (DC)
Always use safety clothing and/or
personal safety devices
Point of connection for grounding
protection
Direct and alternating currents,
respectively Hot surfaces
Time need to discharge stored
energy
Transport and handling
Transportation of the equipment, especially by road, must be carried out using appropriate vehicles and methods to protect the
components (particularly electronic components) from violent shocks, humidity, vibration, etc.
Note for REACT2-BATT: the road transport is regulated by the ADR international agreement.
Lifting
ABB usually stores and protects individual components by suitable means to make their transport and subsequent handling easier. No-
netheless, as a rule, it is necessary to turn to the experience of specialised staff to take charge of loading and unloading components.
Where indicated and/or available, eyebolts or handles, which can be used as anchorage points, are inserted and/or can be inserted.
The means used for lifting must be suitable to bear the weight of the equipment.
Equipment weight
Device Weight (kg) Lifting points
REACT2-UNO-3.6/5.0-TL < 22 kg 4 (suggested in case of 2 operators)
REACT2-BATT 50 kg 4 (suggested in case of 2 operators)
The number of required operators necessary to lift the equipment must be in accordance to local regula-
tions relating lifting limits per operator
Unpacking and checking
The components of the packaging must be disposed on in accordance with the regulations in force in the country of installation.
When you open the package, check that the equipment is undamaged and make sure all the components are present. If you find any
defects or damage, stop unpacking and consult the carrier, and also promptly inform the Service ABB.
2. Labels and Symbols
3. Lifting and transport