Releasing the function to be tested..................................................28
Verifying analog primary and secondary measurement...................29
Testing protection functionality.........................................................30
Section 5 Testing functionality........................................................31
Testing disturbance report................................................................31
Introduction..................................................................................31
Disturbance report settings..........................................................31
Disturbance recorder (DR)..........................................................31
Event recorder (ER) and Event list (EL)......................................32
Identifying the function to test in the technical reference
manual .............................................................................................33
Testing differential protection functions............................................33
Transformer differential protection ..............................................33
Verifying the settings..............................................................33
Completing the test................................................................34
Restricted earth-fault protection, low impedance REFPDIF........34
Verifying the settings..............................................................35
Completing the test................................................................35
Testing current protection functions.................................................35
Instantaneous phase overcurrent protection PHPIOC................35
Measuring the operate limit of set values...............................36
Completing the test................................................................36
Four step phase overcurrent protection OC4PTOC....................36
Verifying the settings..............................................................36
Completing the test................................................................37
Instantaneous residual overcurrent protection EFPIOC..............38
Measuring the operate limit of set values...............................38
Completing the test................................................................38
Four step residual overcurrent protection EF4PTOC..................38
Four step directional residual overcurrent protection ............39
Four step non-directional residual overcurrent
protection................................................................................39
Completing the test................................................................40
Thermal overload protection, two time constants TRPTTR.........40
Checking operate and reset values........................................40
Completing the test................................................................41
Breaker failure protection CCRBRF............................................41
Checking the phase current operate value,
IP>
.....................42
Checking the residual (EF) current operate value
IN>
set below
IP>
..........................................................................42
Checking the re-trip and back-up times..................................42
Verifying the re-trip mode.......................................................43
Verifying the back-up trip mode..............................................43
Table of contents
2RET650
Commissioning Manual