jobAid
DESCRIPTION
TheSmallForm‐FactorPluggable(SFP)3.125GigabitEthernet4
kmisasinglemodefiberSFPthatplugsintoamoduledesigned
toacceptSFPs.TheSFPprovidesadualopticalinterfacetothe
3.125GigabitEthernetphysicalinterface.Installedintoanappro‐
priatemodule,theSFPprovides3.125GigabitEthernetinterface
tothesupportingsystem.
NOTE
ThisSFPshouldnotbeusedinapplicationsrequiringstandard
Gigabit(1000Base)Ethernetservices.
ThefollowingfeaturesaresupportedontheSFP:
♦3.125GigabitEthernetdatarate
♦1310nmTransmitter
♦Wavelength:1310nm
♦Opticaldistance:4kmmaximum
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPssupplied
byADTRANshouldbeused.ADTRANcannotcertifysystem
integritywithotherSFPs.
Operational Specifications
♦OpticalSpecifications:
◊Opticaltransmitlevel:–8.4dBmto–3dBm
◊Opticalreceivelevel:–18dBm
◊Opticalconnectors:LC
◊SFF8472Digitaldiagnosticcompliant
◊CompatiblewithSFPMSA
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+85°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
Small Form-Factor Pluggable
3.125 Gigabit Ethernet 4 km
INSTALLATION
Priortoinstallation,inspecttheSFP.Ifdamagehasoccured
duringshipping,fileaclaimwiththecarrier,andthencontact
ADTRANCustomerSupport.Formoreinformation,referto
“Warranty”.
ToinstalltheSFPintoanappropriatemodule,completethe
followingsteps:
1. DonotremovetheprotectiveendcapfromtheSFPuntilthe
fiberopticcableisreadytobeconnected.
2. InserttheSFPintotheSFPcageonthemodule.Ensurethe
manufacturer’slabelontheSFPisfacingupwardforcorrect
installation.
3. SlidetheSFPallthewayintothereceptacleuntilthereisan
audible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
CAUTION
C
TheSFPisaClass1LaserProductandcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1040.10and1040.11,and
EN60825‐1and‐2.TheSFPisNRTLListedandCBCertifiedtoall
applicableAmericanandEuropeansafetystandards.
TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,andGR‐1089‐CORE.TheSFPis
intendedfordeploymentinCentralOfficetypefacilities,EEEs,
EECs,andlocationswheretheNECapplies(forexample,
CustomerPremises).TheSFPistobeinstalledinADTRAN
productsinRestrictedAccessLocationsonly,andinstalledby
trainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CLEI: BVL3ADND_ _
Product P/N: 1442804G1
Issue Date: December 2010
Document P/N: 61442804G1-22B
C A U T I O NC A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442804G1-22B*
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPdoesnothaveaninternal
DCconnectionbetweenbatteryreturnandframeground.The
SFPcanbeinstalledinaDC‐I(isolated)orDC‐C(common)
installation.Forinstallationswhereothercardsorthehost
systemhaveinternalconnectionsbetweenbatteryreturnand
frameground,thesystemwouldbeintendedfordeployment
onlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPisproperlygroundedviathebackplane
connector.
NOTE
The3.125GigabitEthernetport(s)areopticalandthereforeare
notclassifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue4.
TheSFPisdesignedtomeetthefollowingenvironmentalclasses:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions,Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions,Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.

Other ADTRAN Control Unit manuals

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN OC-3 User manual

ADTRAN

ADTRAN OC-3 User manual

ADTRAN jobAid+ SFP+ 11.3 G BIDI 20KM User manual

ADTRAN

ADTRAN jobAid+ SFP+ 11.3 G BIDI 20KM User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN 1200068L1 HS Series User manual

ADTRAN

ADTRAN 1200068L1 HS Series User manual

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN 1200261L1 User manual

ADTRAN

ADTRAN 1200261L1 User manual

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN Quad T1 User manual

ADTRAN

ADTRAN Quad T1 User manual

ADTRAN Octal BRI/U User manual

ADTRAN

ADTRAN Octal BRI/U User manual

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN MX2820 User manual

ADTRAN

ADTRAN MX2820 User manual

ADTRAN TRACER QUAD E1 User manual

ADTRAN

ADTRAN TRACER QUAD E1 User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN

ADTRAN Job Aid+ 1442971GX User manual

Popular Control Unit manuals by other brands

SMC Networks EX250-SPR1 Operation manual

SMC Networks

SMC Networks EX250-SPR1 Operation manual

Ross 27 Series Installation

Ross

Ross 27 Series Installation

Velocity VDOT-SCM-SCI instruction manual

Velocity

Velocity VDOT-SCM-SCI instruction manual

DSC PCL422 installation instructions

DSC

DSC PCL422 installation instructions

SMC Networks VQ2000 Series Installation and maintenance manual

SMC Networks

SMC Networks VQ2000 Series Installation and maintenance manual

Marmitek Invisible Control 2 user manual

Marmitek

Marmitek Invisible Control 2 user manual

Vega VEGAKON 61 operating instructions

Vega

Vega VEGAKON 61 operating instructions

Gira eNet operating instructions

Gira

Gira eNet operating instructions

VPro DN Series instruction manual

VPro

VPro DN Series instruction manual

Telit Wireless Solutions BlueMod+S42M Hardware user's guide

Telit Wireless Solutions

Telit Wireless Solutions BlueMod+S42M Hardware user's guide

Beckhoff AX5721 Technical documentation

Beckhoff

Beckhoff AX5721 Technical documentation

WAPRO WAGATE SVM-TG125 Installation & maintenance

WAPRO

WAPRO WAGATE SVM-TG125 Installation & maintenance

Bristan TS6000ECP Installation instructions and user guide

Bristan

Bristan TS6000ECP Installation instructions and user guide

Linear Technology DC1589A Quick start guides

Linear Technology

Linear Technology DC1589A Quick start guides

Nil-Cor 310 Series Installation maintenance and operating instructions

Nil-Cor

Nil-Cor 310 Series Installation maintenance and operating instructions

Yale iM1 quick start guide

Yale

Yale iM1 quick start guide

FUTABA AH145AA Application note

FUTABA

FUTABA AH145AA Application note

DAV TECH DA 400 Installation and maintenance guide

DAV TECH

DAV TECH DA 400 Installation and maintenance guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.