61181007L2-5A 1
Total Access®Quad BNC Adapter Module
Installation and Maintenance
Section 61181007L2-5A
Issue 1, February 2003
CONTENTS
1. GENERAL ............................................................1
2. FEATURES ..........................................................1
3. INSTALLATION .................................................3
4. CONNECTIONS ..................................................3
5. MAINTENANCE .................................................3
6. PRODUCT SPECIFICATIONS ...........................4
7. WARRANTY AND CUSTOMER SERVICE .....4
Figure 1. ADTRAN Total Access Quad
BNC Adapter Module
1. GENERAL
This ractice is an installation and maintenance guide
for the ADTRAN Total Access Quad BNC Ada ter
Module illustrated in Figure 1. The 1181007L2 Quad
BNC Ada ter Module is designed to mount on the
rear of the ADTRAN Total Access chassis,
P/N 1181001L1 (23-inch) or 1182003L1 (19-inch).
The Quad BNC Ada ter Module rovides Dual STS-1
interfaces for the Total Access 3000 and Total Access
3010 Chassis. The Quad BNC Ada ter Module must
be used in conjunction with an OC-3 L2 MUX (P/N
1181031L2). It will also work in conjunction with
either the L1 or L2 versions of the STS-1 MUX (P/N
1181030L1/L2). For information on the OC-3 L2
MUX, refer to ADTRAN Document 61181031L2-5A.
Revision History
This is the initial issue of this ractice. Future
revisions to this document will be ex lained in this
subsection.
2. FEATURES
The Quad BNC Ada ter Module is designed to mount
on the lower right-hand corner of the back lane of a
Total Access 3000 or Total Access 3010 chassis. The
unit rovides the coax cable connections for two Total
Access chassis which subtend from a Total Access
equi ed with an OC-3 L2 MUX.
The Quad BNC Ada ter Module for the Total Access
chassis rovides a data ath for two STS-1s from the
OC-3 equi ment Total Access to the subtending Total
Access chassis.
The Quad BNC Ada ter Module rovides:
1. Pro er receive termination for an EC-1 signal.
2. A means of interfacing the transmit EC-1 line
from either multi lexer module.
3. Four 75-ohm BNC connectors – two for
transmit data and two for receive data.
4. Connection to the Total Access back lane at
the 24- in connector rovided for that ur ose
and attaches with screws to ensure rigidity.
J2
J1
J3
J4
TX1
RX1
1181007L2
TX2
RX2
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
FIGURES
Figure 1. ADTRAN Total Access Quad BNC
Ada ter Module .........................................1
Figure 2. Block Diagram of the Quad BNC Ada ter
Module .......................................................2
TABLES
Table 1. Quad BNC Ada ter Module
S ecifications .............................................4
All manuals and user guides at all-guides.com
all-guides.com
261181007L2-5A
Figure 2 is a block diagram of the Quad BNC Ada ter
Module for Total Access 3000 and Total Access 3010.
Figure 2. Block Diagram of the Quad BNC Adapter Module
S litter
Pin 1 RX to MUX A (EC-1 #1)
Receive (1)
In ut
(BNC)
Receive (2)
In ut
(BNC)
Transmit (1)
Out ut
(BNC)
Transmit (2)
Out ut
(BNC)
Pin 22 RX to MUX B (EC-1 #1)
Pins 2, 4, 5, 6 (A RX Gnd)
Pins 18, 19, 21 (B RX Gnd)
Pin 20 RX to MUX B (EC-1 #2)
Pin 3 RX to MUX A (EC-1 #2)
20
3
Pin 8 TX from MUX A (EC-1 #1)
Pin 15 TX from MUX B (EC-1 #1)
Pins 7, 9, 11, 12 (A TX Gnd)
Pins 14, 16, 17 (A TX Gnd)
Pin 10 TX from MUX A (EC-1 #2)
Pin 13 TX from MUX B (EC-1 #2)
R-Term
R-Term
S litter
R-Term R-Term
All manuals and user guides at all-guides.com
61181007L2-5A 3
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
3. INSTALLATION
After un acking the unit, ins ect it for damage. If
damage is discovered, file a claim with the carrier,
then contact ADTRAN. Refer to Warranty and
Customer Service.
Two hilli s-head ca tive screws are rovided with
the Quad BNC Ada ter Module. Use the screws and a
hilli s screwdriver to attach the Quad BNC Ada ter
Module to the back of the Total Access 3000 or Total
Access 3010 chassis with the screw s acer between
the Quad BNC Ada ter and the chassis surface.
CAUTION
This module should never be installed while
ower is resent on the chassis. Doing so can
cause damage to the back lane during
installation.
To be UL 1950 certified, ADTRAN requires that these
installation guidelines be followed:
• The Quad BNC Ada ter Module is intended
for installation in Restricted Access Locations
Only.
• The Quad BNC Ada ter Module must be
installed in accordance with the requirements
of NEC NFPA 70.
4. CONNECTIONS
Coax cable is easily connected to the Quad BNC
Ada ter Module. The RX connectors on the Quad
BNC Ada ter Module connect to the two EC-1 signals
coming from the network. Similarly, the TX
connectors on the Quad BNC Ada ter Module
connect to the two EC-1 signals going to the network.
To be UL 1950 certified, ADTRAN requires that the
following connection guidelines be observed:
• The Total Access chassis must be connected
to a reliably grounded -48 VDC source which
is electrically isolated from the AC source.
• The frame ground stud located on the chassis
must be connected to a reliable frame ground
source.
• A readily accessible disconnect device that is
suitably a roved and rated must be
incor orated into the fixed ower wiring
(e.g., Fuse and Alarm Panel).
• The branch circuit overcurrent rotection
must be a ro erly sized fuse or circuit
breaker rated for −48 V.
5. MAINTENANCE
The ADTRAN Total Access Quad BNC Ada ter
Module does not require any routine maintenance for
normal o eration. ADTRAN cautions against
erforming major re airs in the field. Re air services
may be obtained by returning the defective unit to
ADTRAN. (Refer to the Warranty and Customer
Service section of this ractice.)
All manuals and user guides at all-guides.com
461181007L2-5A
6. PRODUCT SPECIFICATIONS
Product s ecifications are detailed in Table 1.
7. WARRANTY AND CUSTOMER SERVICE
ADTRAN will re lace or re air this roduct within
the warranty eriod if it does not meet its ublished
s ecifications or fails while in service. Warranty
information can be found at
www.adtran.com/warranty.
U.S. and Canada customers can also receive a co y of
the warranty via ADTRAN’s toll-free faxback server
at 877-457-5007.
• Request Document 414 for the U.S. and Canada
Carrier Networks Equipment Warranty.
• Request Document 901 for the U.S. and Canada
Enterprise Networks Equipment Warranty.
Refer to the following subsections for sales, su ort,
CAPS requests, or further information.
ADTRAN Sales
Pricing/Availability:
800-827-0807
ADTRAN Technical Support
Pre-Sales Applications/Post-Sales Technical Assistance:
800-726-8663
Standard hours: Monday - Friday, 7 a.m. - 7 .m. CST
Emergency hours: 7 days/week, 24 hours/day
ADTRAN Repair/CAPS
Return for Repair/Upgrade:
(256) 963-8722
Repair and Return Address
Contact Customer and Product Service (CAPS) prior
to returning equipment to ADTRAN.
ADTRAN, Inc.
CAPS Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
Size:
2.3 in. H x 1.4 in. W x 1.75 in. D
Conforms to Total Access 3000 and 3010 mechanical and inout requirements
Connector:
24- in low rofile .050 in. centers male header with end shrouds and guide osts
Environmental:
-40ºC to +65ºC o erational
-40ºC to +85ºC storage
U to 95% noncondensing humidity
Regulatory Re uirements:
NEBS Level 3
GR-1089-CORE
UL1950
Table 1. Quad BNC Adapter Module Specifications
All manuals and user guides at all-guides.com

Other ADTRAN Control Unit manuals

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN T3 User manual

ADTRAN

ADTRAN T3 User manual

ADTRAN Quad E1/PRA User manual

ADTRAN

ADTRAN Quad E1/PRA User manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN 1442442F1 User manual

ADTRAN

ADTRAN 1442442F1 User manual

ADTRAN 1200315L1 User manual

ADTRAN

ADTRAN 1200315L1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

ADTRAN Total Access 300 User manual

ADTRAN

ADTRAN Total Access 300 User manual

ADTRAN Type 400 User manual

ADTRAN

ADTRAN Type 400 User manual

ADTRAN NetVanta SHDSL User manual

ADTRAN

ADTRAN NetVanta SHDSL User manual

ADTRAN Modem-16 Module User manual

ADTRAN

ADTRAN Modem-16 Module User manual

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN 1200068L1 HS Series User manual

ADTRAN

ADTRAN 1200068L1 HS Series User manual

ADTRAN Total Access 351 Series User manual

ADTRAN

ADTRAN Total Access 351 Series User manual

ADTRAN Octal E&M User manual

ADTRAN

ADTRAN Octal E&M User manual

Popular Control Unit manuals by other brands

RadiSys EPC-26A/27 manual

RadiSys

RadiSys EPC-26A/27 manual

GST DC-9503E quick start guide

GST

GST DC-9503E quick start guide

Apator Powogaz APT-VERTI-1 user manual

Apator Powogaz

Apator Powogaz APT-VERTI-1 user manual

Daikin Rotex RoCon G1 Installation and operation manual

Daikin

Daikin Rotex RoCon G1 Installation and operation manual

Blood Cells Audio Auscult manual

Blood Cells Audio

Blood Cells Audio Auscult manual

BFT RIGEL 5 Installation and user manual

BFT

BFT RIGEL 5 Installation and user manual

GCE S 400 Instructions for use

GCE

GCE S 400 Instructions for use

Triax TDH 800 Configuration guide

Triax

Triax TDH 800 Configuration guide

Pfeiffer Vacuum TPG 361 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum TPG 361 operating instructions

National Instruments 9501 C Series Getting started

National Instruments

National Instruments 9501 C Series Getting started

Parker IOTA ONE Series manual

Parker

Parker IOTA ONE Series manual

V2 LUX2+ manual

V2

V2 LUX2+ manual

ITT Industries Bell & Gossett B-38 instruction manual

ITT Industries

ITT Industries Bell & Gossett B-38 instruction manual

Pilz PSSu E S INC 24V se manual

Pilz

Pilz PSSu E S INC 24V se manual

CAT Pumps 7537 datasheet

CAT Pumps

CAT Pumps 7537 datasheet

HydroAir 20-0242 quick start guide

HydroAir

HydroAir 20-0242 quick start guide

Seneca Z-8TC-LAB installation manual

Seneca

Seneca Z-8TC-LAB installation manual

Hach RTC101 Basic user manual

Hach

Hach RTC101 Basic user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.