manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Control Unit
  8. •
  9. ADTRAN SFP GPON ONU User manual

ADTRAN SFP GPON ONU User manual

This manual suits for next models

2

Other ADTRAN Control Unit manuals

ADTRAN 1200222L1 User manual

ADTRAN

ADTRAN 1200222L1 User manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN 1200791L1 User manual

ADTRAN

ADTRAN 1200791L1 User manual

ADTRAN 1200261L1 User manual

ADTRAN

ADTRAN 1200261L1 User manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN Quad E1/PRA User manual

ADTRAN

ADTRAN Quad E1/PRA User manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN Octal BRI/U User manual

ADTRAN

ADTRAN Octal BRI/U User manual

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN Octal User manual

ADTRAN

ADTRAN Octal User manual

ADTRAN NetVanta SHDSL User manual

ADTRAN

ADTRAN NetVanta SHDSL User manual

ADTRAN FXS+ Quad User manual

ADTRAN

ADTRAN FXS+ Quad User manual

ADTRAN Modem-16 Module User manual

ADTRAN

ADTRAN Modem-16 Module User manual

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN 1200065L1-1 User manual

ADTRAN

ADTRAN 1200065L1-1 User manual

ADTRAN jobAid+ SFP+ 11.3 G BIDI 20KM User manual

ADTRAN

ADTRAN jobAid+ SFP+ 11.3 G BIDI 20KM User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Q
uic
k
Start
DESCRIPTION
The Small Form-Factor Pluggable (SFP) is a single-mode fiber
SFP that plugs into an ADTRAN optical interface designed to
accept SFPs. The SFP provides a single optical interface to a
physical interface, and is intended for use with a Gigabit Passive
Optical Network (GPON) module.
This SFP is designed for use in GPON ONU applications. When
installed into an appropriate module, the SFP provides a GPON
interface to the supporting system.
This SFP has a Digital Diagnostic Monitoring (DDM) function with
internal calibration.
This Quick Start covers the following SFPs:
INSTALLATION
To install the SFP into an appropriate module, complete the
following steps:
1. Inspect the SFP. If damaged, file a claim with the carrier and
then contact ADTRAN Customer Service.
2. Do not remove the protective dust cover from the SFP until
the fiber optic cable is ready to be connected.
3. Insert the SFP into the SFP cage on the module. Ensure the
manufacturer’s label on the SFP is facing upward for correct
installation.
4. Slide the SFP all the way into the receptacle until there is an
audible “click.”
fCAUTION!
Due to compliance certification requirements, use only SFPs
supplied by ADTRAN. ADTRAN cannot certify system integrity
with other SFPs.
wNOTICE
The latch on the SFP is used to remove the SFP from the cage on
the circuit card.
gNOTE
This device should not be used in central office applications.
SFP PN
SFP GPON ONU 2.5G/1.25G 20km
(Fixed speed 2.5G)
1442535F2
SFP GPON ONU 2.5G/1.25G 20km
(speed is auto-negotiated)
1442535F3
OPERATIONAL SPECIFICATIONS
General
■Module type: SFP
■Fiber/Copper: Fiber
♦SM/MM: Single Mode Fiber
♦Single/Dual-fiber: Single-fiber
■Optical Connector: SC/APC
■Applications: GPON ONU
■Distance: 20 km
■Digital Diagnostic Monitoring: SFF8472 Compliant
Optical
■Optical Budget: 26 dB (+/- 1)
■Transmitter
♦Laser Diode Type: DFB
♦Tx Central Wavelength: 1310 nm
♦Tx Optical Power: +0.5 dBm to +5.0 dBm
♦Tx Spectral width: 1 nm
♦SMSR: 30 dB
♦Extinction Ratio: 10 dB
■Receiver
♦Rx Type: APD/TIA
♦Rx Central wavelength: 1490 nm
♦Rx Optical Power: –8.0 dBm to –27.0 dBm
♦Receiver Overload: –8 dBm
♦Receiver Sensitivity: –27 dBm
Environmental
■Protected Equipment Environment (Outdoor)
♦System Ambient Operational temperature range: –40°C to
+65°C
♦Storage temperature range: –40°C to +85°C
♦Relative humidity to 5 to 95%, non-condensing
ADTRAN Pluggable Optics
SFP GPON ONU
2.5G/1.25G, 20 km
January 2021
61442535F2-13D
P/N: 1442535F2
261442535F2-13D
gNOTE
■This product is designed to be deployed in GR-3108-CORE
environmental class 1, class 2, and class 3 as defined in GR-
3108-CORE.
■This product is NRTL Listed to the applicable UL Standards.
The product is designed to meet the applicable requirements
of Telcordia GR-63-CORE, GR-1089-CORE and GR-3108-
CORE.
■This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
■Changes or modifications not expressly approved by ADTRAN
could void the user's authority to operate this equipment.
■This product meets EU RoHS Directive. Refer to
www.adtran.com for further information on RoHS/WEEE.
SAFETY AND REGULATORY
ENGLISH
fWARNING!
Read all warnings, cautions, notes and installation instructions
before installing or servicing this equipment.
CCAUTION!
This product contains or uses a Class 1 Laser module that
complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1.
For continued compliance with the above standards, only
approved Class 1 laser modules from an ADTRAN approved
vendor list (located on the ADTRAN website) should be installed
in this product. ADTRAN cannot certify system integrity with other
laser modules.
fCAUTION!
■Electrostatic Discharge (ESD) can damage electronic devices.
When handling devices, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
devices in antistatic packing material when transporting or
storing. When installing or maintaining, always place devices
on an approved antistatic mat that is electrically grounded.
■This product and the host system are designed and intended
for installation as part of a Common Bonding Network (CBN).
This product and the host system are not designed nor
intended for installation as part of an Isolated Bonding Network
(IBN).
■This product's outer case may not be "electrically isolated"
from other circuits. As a result, this product can only be used
in systems that are installed in a DC-C (common)
configuration.
■If the host system has a protective earth (PE) terminal, the PE
terminal of the host system must be connected to protective
earth (PE) to ensure that the exposed metal (i.e., front panels,
optical modules) on the product is properly grounded.
61442535F2-13D 3
FRANÇAIS
fAVERTISSMENT!
Lisez toutes les mentions de danger et de prudence et les
remarques, ainsi que la notice d'installation, avant d'effectuer
l'installation ou l'entretien de cet équipement.
CATTENTION!
Ce produit contient ou utilise un module Laser de classe 1 qui est
conforme avec la FDA 21 CFR 1040.10, 1040.11 et IEC 60825-1.
Pour le maintien de la conformité avec les normes ci-dessus,
seulement approuvé classe 1 modules laser d'un ADTRAN
approuvés liste des fournisseurs (situé sur le site ADTRAN) doit
être installé dans ce produit. ADTRAN ne peut certifier l'intégrité
du système avec d'autres modules laser.
fATTENTION!
■Les décharges électrostatiques (ESD) peuvent endommager
les appareils électroniques.Lors de la manipulation des
appareils, portez un bracelet antistatique, afin d'éviter
d'endommager les composants électroniques.Mettez les
appareils dans un emballage antistatique, lors de leur
transport ou de leur entreposage.Lors de leur installation ou de
leur entretien, les appareils doivent toujours être placés sur un
tapis antistatique homologué, qui est mis à terre.
■Ce produit et le système hôte sont conçus et destinés à être
installés dans le cadre d'un réseau Bonding commun (CBN).
Ce produit et le système hôte ne sont pas conçus, ni destinés
à être installés dans le cadre d'un réseau de Bonding isolé
(IBN).
■Le boîtier extérieur de ce produit pourrait ne pas être " isolé
galvaniquement " des autres circuits. Donc ce produit peut être
utilisé uniquement dans des systèmes dotés d'une
configuration de retour commun d'alimentation en courant
continu (c.c.-C).
■Si le système hôte est doté d'une borne de mise à la terre de
protection (PE), la borne PE du système hôte doit être
connectée à la mise à terre de protection (PE), afin d'assurer
que les parties métaliques à découvert (panneaux frontaux,
modules optiques) du produit soient correctement mis à terre.
gREMARQUE
Ce produit est conforme à la directive européenne RoHS.
Reportez-vous à www.adtran.com pour de plus amples rensei-
gnements sur RoHS/WEEE.
DEUTSCH
fWARNUNG!
Lesen Sie alle Warnungen, Gefahrenhinweise, Anmerkungen und
Installationsanweisungen bevor Sie dieses Gerät installieren oder
warten.
CVORSICHT!
Das Produkt enthält oder verwendet Klasse 1 Laser-Module, die
mit FDA 21 CFR 1040.10, 1040.11 und IEC 60825-1 erfüllen.
Damit die obigen Richtlinien auch in Zukunft eingehalten werden
können, dürfen ausschließlich Klasse 1 Lasermodule von einem
von ADTRAN zugelassenen Anbieter in dem Produkt installiert
werden (siehe Website von ADTRAN). ADTRAN garantiert nicht
für die Systemintegrität bei anderen Lasermodulen.
fVORSICHT!
■Elektrostatische Entladung (ESD) kann elektronische Geräte
beschädigen. Tragen Sie bei der Handhabung von Geräten
ein Antistatik-Armband mit Erdungskabel, um Schäden an
elektronischen Komponenten zu vermeiden.Während des
Transports oder bei der Lagerung müssen Geräte in
antistatischem Verpackungsmaterial gelegt werden. Geräte
bei der Installation oder Wartung immer auf einer
zugelassenen antistatischen, elektrisch geerdeten Matte
stellen.
■Dieses Produkt und das Host-System entworfen und für die
Installation als Teil einer gemeinsamen Bonding Network
(CBN) vorgesehen. Dieses Produkt und das Host-System
nicht noch für die Installation als Teil eines isolierten Bonding
Network (IBN) bestimmt sind.
■Das äußere Gehäuse dieses Produktes mag nicht von
anderen Stromkreisen "elektrisch isoliert" sein. Deshalb kann
dieses Produkt nur in Systemen verwendet werden, die in
einer gemeinsamen Gleichstrom-Rücklauf-Konfiguration
installiert sind.
■Falls das Host-System über einen Schutzleiteranschluss (PE)
verfügt, muss der PE-Anschluss des Host-Systems mit dem
Schutzleiteranschluss (PE) verbunden werden, um
sicherzustellen, dass das freiliegende Metall (d. h.
Frontblenden, Optikmodule) am Produkt ordnungsgemäß
geerdet ist.
gHINWEIS
Dieses Produkt erfüllt die EU RoHS Richtlinie. Sie
www.adtran.com für ausführlichere Informationen zu RoHS/
WEEE.
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at www.adtran.com/warranty.
Trademarks: Brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
Copyright © 2021 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.888.423.8726
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442535F2-13D*
Documentation for ADTRAN Network Solutions products is available for
viewing and download directly from the ADTRAN Support Community
website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including customized
training and courses taught at our facilities or at customer sites.
For inquiries, go to: http://adtran.com/training
The following online documents and resources provide additional information for this product:
ADTRAN Pluggable Optics Compatibility Matrix
(online tool, go to: http://www.adtran.com/pluggableoptics)