EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Amana
  6. •
  7. Air Conditioner
  8. •
  9. Amana AAC081SRA Service Manual

Amana AAC081SRA Service Manual

Other manuals for AAC081SRA Service

1

Other Amana Air Conditioner manuals

Amana AP125HD User manual

Amana

Amana AP125HD User manual

Amana PGA**C User manual

Amana

Amana PGA**C User manual

Amana AAC081SRA Service User manual

Amana

Amana AAC081SRA Service User manual

Amana ACE24KE User manual

Amana

Amana ACE24KE User manual

Amana ACB055E User manual

Amana

Amana ACB055E User manual

Amana AAC051SRA User manual

Amana

Amana AAC051SRA User manual

Amana GSH13018 Operating instructions

Amana

Amana GSH13018 Operating instructions

Amana Ultra Quiet Zone Room Air Conditioner User manual

Amana

Amana Ultra Quiet Zone Room Air Conditioner User manual

Amana ERCF18-UO1B User manual

Amana

Amana ERCF18-UO1B User manual

Amana P1212701R Assembly instructions

Amana

Amana P1212701R Assembly instructions

Amana DRY 093Gxxx series XXX User manual

Amana

Amana DRY 093Gxxx series XXX User manual

Amana Room Air Conditioner & Heat Pump User manual

Amana

Amana Room Air Conditioner & Heat Pump User manual

Amana 10c5ez Assembly instructions

Amana

Amana 10c5ez Assembly instructions

Amana AP095R User manual

Amana

Amana AP095R User manual

Amana AVXC20 Series Operating instructions

Amana

Amana AVXC20 Series Operating instructions

Amana PTC073D00ARDA Owner's manual

Amana

Amana PTC073D00ARDA Owner's manual

Amana VTC123A00AA P1233605R User manual

Amana

Amana VTC123A00AA P1233605R User manual

Amana Quiet Zone Room Air Conditioner User manual

Amana

Amana Quiet Zone Room Air Conditioner User manual

Amana C-Model Assembly instructions

Amana

Amana C-Model Assembly instructions

Amana APN14J User manual

Amana

Amana APN14J User manual

Amana R-AMAP081BW User manual

Amana

Amana R-AMAP081BW User manual

Amana REMOTE CONDENSING UNIT Guide

Amana

Amana REMOTE CONDENSING UNIT Guide

Amana AP077R User manual

Amana

Amana AP077R User manual

Amana AP099R User manual

Amana

Amana AP099R User manual

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Amana Technical Information—Room Air Conditioner
December 2002 16022063
(Replaces RT4110055 Rev. 0)
1
AAC081SRA PAAC081SRA0
• Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this air conditioner.
• Refer to Service Manual 16022061 for installation, operation, disassembly, testing, and troubleshooting
information.
• Refer to Parts Reference material for part number information.
CAUTION
!
All safety information must be followed as provided in Service Manual 16022061.
!WARNING
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge
capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during
disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Model AAC081SRA
Electrical requirements 115V VAC 60Hz
Refrigerant/amount HCFC22/25.8 ounces
Compressor
Voltage low/high (nominal)
BTUH
98/132 VAC (115 VAC)
8,390 BTUH
Watts 790 watts
Current
Lock rotor
Full load
42 amps
7.1amps
Overload protector External
Fan motor
Electrical requirements
RPM
Low speed
Med speed
High speed
Watts at high speed
Current at high speed
115 VAC 60Hz
700 RPM
800 RPM
1000 RPM
60 watts
1.4 amps
Compressor Capacitor
Capacitance
Voltage rating (nominal)
40 Mfd ±10%
250 VAC
Fan motor Capacitor
Capacitance
Voltage rating (nominal)
5 Mfd ±10%
450 VAC
https://appliancetechmanuals.com
Component Specifications
16022063 December 2002
(Replaces RT4110055 Rev. 0)
2
!WARNING
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and
discharge capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed
during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Illustration Component Test Procedure Results
Compressor Check resistance of compressor windings:
Attach ohmmeter between winding C and S:
Attach ohmmeter between winding C and R:
Check compressor for grounds:
Attach one ohmmeter lead to compressor
case. Attach second ohmmeter lead to C,
then S, then R terminals on compressor:
NOTE: See Testing Procedures section of Service Manual
for additional compressor information.
Ohmmeter should indicate resistance
between windings.
Ohmmeter should indicate resistance
between windings.
Ohmmeter should indicate infinity on each
terminal.
Compressor
overload
Continuity
Ensure temperature of overload is at room temp.
Check continuity across leads: Overload should have continuity.
Compressor
Capacitor
Resistance (highest scale), with power removed.
Discharge capacitor and disconnect all attached wires.
Attach Analog ohmmeter leads between C terminal
and H terminal on capacitor:
Reverse leads on C and H terminals:
Check capacitor for ground.
Attach one ohmmeter lead to capacitor
case. Attach second ohmmeter lead to H,
then C terminals on capacitor:
Indicator swings to zero and slowly returns
toward infinity.
Indicator swings to zero and slowly returns
toward infinity.
Infinity on ohmmeter indicates capacitor
not grounded.
Fan motor Check for resistance of fan motor windings:
Attach one ohmmeter lead to common fan
motor lead. Attach second lead to remaining
fan motor leads, one at a time:
Check fan motor for grounds:
Attach one ohmmeter lead to fan motor case.
Attach second ohmmeter lead to each fan
motor lead, one at a time:
Ohmmeter should indicate resistance
between windings.
Ohmmeter should indicate infinity on each
lead.
Fan Motor Capacitor Resistance (highest scale), with power removed.
Discharge capacitor and disconnect all attached wires.
Attach Analog ohmmeter leads between C terminal
and F terminal on capacitor:
Reverse leads on C and F terminals:
Check capacitor for ground.
Attach one ohmmeter lead to capacitor
case. Attach second ohmmeter lead to F,
then C terminals on capacitor:
Indicator swings to zero and slowly returns
toward infinity.
Indicator swings to zero and slowly returns
toward infinity.
Infinity on ohmmeter indicates capacitor
not grounded.
Selector switch Position Function
1Off
2 Low Fan
3 Low Cool
4 Med Cool
5 High Cool
6HighFan
Contacts Made
None
1,2
1,2,8
1,4,8
1,6,8
1,6
https://appliancetechmanuals.com
Component Specifications
December 2002 16022063
(Replaces RT4110055 Rev. 0)
3
!WARNING
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and
discharge capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed
during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Illustration Component Test Procedure Results
Thermostat Attach ohmmeter leads between 2 and 1:
Attach ohmmeter leads between 2 and 3:
Turn control to warmest setting. Check for
continuity. Contacts close when control
warms.
Turn control to coldest setting. Check for
continuity. Contacts close when control
cools.
If continuity is not indicated, replace
affected control.
https://appliancetechmanuals.com
Wiring Diagrams and Schematics
16022063 December 2002
(Replaces RT4110055 Rev. 0)
4
!WARNING
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and
discharge capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed
during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
AAC081SRA PAAC081SRA0
WIRING DIAGRAM
OPTIONAL
LOW FAN SPEED
HIGH COOL
MID COOL
LOW COOL
0010540372
OFF
POWERSUPPLY
6
48
2
1
HIGH FAN SPEED
SWITCH
COMPRESSOR
CAPACITOR
B
R
R: RED
BR: BROWN
BL: BLUE
G: GREEN
Y: YELLOW
M
RC
RBL
W: WHITE
B: BLACK
H
BL
R
C
GB
L
S
PROTECTOR
THERMOSTAT
FAN MOTOR
L
M
W
M
Y
BR
CAPACITOR
https://appliancetechmanuals.com