Amit RRU-WEC/1201 User manual

rru-wec1201_g_en_100
RRU-WEC/1201
WTB / Ethernet / CAN gateway
Operation manual
Revision 1.00

RRU-WEC/1201
rru-wec1201_g_en_100 2/34
AMiT, spol. s r.o. does not provide any warranty concerning the contents of this
publication and reserves the right to change the documentation without
obligation to inform anyone or any authority about it.
This document can be copied and redistributed under following conditions:
1. The whole text (all pages) must be copied without any changes.
2. All redistributed copies must retain the AMiT, spol. s r.o. copyright notice
and any other notices contained in the documentation.
3. This document must not be distributed for purpose of making profit.
The names of products and companies used herein can be trademarks or
registered trademarks of their respective owners.
AMiT is a registered trademark.
Copyright (c) 2016, AMiT, spol. s r. o.
Producer: AMiT, spol. s r. o.
Naskové 1100/3, 150 00 Praha
www.amit-transportation.com

RRU-WEC/1201
3/34 rru-wec1201_g_en_100
Contents History of revisions.........................................................................................4
Related documentation...................................................................................4
Used symbols.................................................................................................4
1. Definition of used abbreviations ........................................................5
2. Definition of used terms......................................................................6
3. Introduction..........................................................................................7
4. Technical parameters..........................................................................8
4.1. Dimensions...................................................................................................11
4.2. Recommended drawing symbol ...................................................................12
4.3. Block diagram...............................................................................................13
4.4. Type label.....................................................................................................14
5. Conformity assessment ....................................................................16
5.1. Other tests....................................................................................................17
6. Power supply......................................................................................18
6.1. Powering from DC network...........................................................................18
7. Communication lines.........................................................................19
7.1. WTB .............................................................................................................19
7.1.1 WTB line state indication..............................................................................20
7.2. Ethernet........................................................................................................21
7.2.1 Ethernet line state indication ........................................................................22
7.3. CAN..............................................................................................................23
7.3.1 CAN lines status indication...........................................................................24
8. Indications and settings....................................................................25
8.1. System LEDs................................................................................................25
8.2. Service mode and factory setting .................................................................26
8.3. Commissioning.............................................................................................26
9. Mounting, installation rules ..............................................................27
9.1. Mounting instructions....................................................................................27
9.2. Mounting template........................................................................................29
9.3. Installation rules............................................................................................29
10. Ordering information and completion .............................................30
10.1. Ordering Information.....................................................................................30
10.2. Completion ...................................................................................................30
11. Packing ...............................................................................................31
12. Storing.................................................................................................32
13. Maintenance .......................................................................................33
14. Waste disposal...................................................................................34

RRU-WEC/1201
rru-wec1201_g_en_100 4/34
History of revisions
Document name: rru-wec1201_g_en_100.pdf
Revision
Date
Author of change
Changes
100
21.10.2016
Škoch J.
New document
Related documentation
1. SW for WTB/ETHERNET/CAN Gateway –Programmer’s manual
file: tcn-gw-wec_ref_ms_en_xxx.pdf
Used symbols
Check documentation mentioned above
Important note
Danger of electric shock
Warning symbol
Warning against electrostatic discharge
Electronic equipment is intended for recycling in the collection point

RRU-WEC/1201
5/34 rru-wec1201_g_en_100
1. Definition of used abbreviations
Bus Administrator
Electric Middle Distance
Medium Attachment Unit
Multifunction Vehicle Bus
Message Data
Process Data
To Be Defined
Train Communication Network
Wire Train Bus
BA
EMD
MAU
MVB
MD
PD
TBD
TCN
WTB

RRU-WEC/1201
rru-wec1201_g_en_100 6/34
2. Definition of used terms
Bus Administrator
MVB device with Bus Administrator functionality is able to work as MVB bus
Master. This function supposes the device is able to transfer the process data
and reports as well as transmit and receive the Device Status type information.
Electric Middle Distance
This is a type of physical interface of MVB line, where a twisted pair of shielded
wires is used for interconnection with implementing of transformer coupling for
galvanic isolation. EMD medium is used for up to 32 nodes and for distances up
to 200 m.
End Setting
The node in this state is physically connected on the end of WTB line, or
between two independent segments. One of the MAU channels is connected in
direction 1 and the second in direction 2. The WTB line segments, connected in
direction 1 and 2 are disconnected. Terminating resistors are connected in both
directions.
Intermediate Setting
The node in this state is physically connected in the middle of WTB line. The
main MAU channel is connected in direction 1 or in direction 2, the auxiliary
MAU channel is deactivated. The WTB line segments, connected in direction 1
and 2 are interconnected. Terminating resistors are disconnected in both
directions.
Line gate (Line Unit)
All HW resources, providing the electrical connection of MAU to the WTB line.
Medium Attachment Unit
Part of node, which arranges the link to transmission medium.
Sleep Mode
In this mode, the node goes to End Setting state. Only part of MAU is active.
The node detects valid frames on line.
To Be Defined
Information will be completed in document revision.
TCN Gateway
MVB device with TCN Gateway function is able to access other buses. This
function of the device is able to transfer the process data and reports as well as
transmit and receive the Device Status type information.

RRU-WEC/1201
7/34 rru-wec1201_g_en_100
3. Introduction
RRU-WEC/1201 is a communication gateway which serves for transfer of
process data and messages between WTB, ETH and CAN buses. Gateway is
officially homologated and approved for international use according to UIC 556
standard. CAN bus communication protocol meets the requirements of EN
61375-3-3:2012.
Gateway is supplied from factory with loader only. Prior to first use, the
appropriate application software must be loaded into the gateway.
1 × WTB interface (doubled line) according to EN 61375-2-1:2012 standard
2 × CAN interface (doubled line) according to EN 61375-3-3 standard
1 × Ethernet 100 Mbps (connector M12 according to EN 61375-3-4:2014)
Power supply 24 V DC
Compact aluminium chassis
Rolling stock electronic device
Design according to EN 50155:2007
Approved according to UIC CODE 556:2010
Basic features

RRU-WEC/1201
rru-wec1201_g_en_100 8/34
4. Technical parameters
Number of WTB lines
1 (double line)
Operation indication
16 × LED
Galvanic isolation
Yes, 1000 V AC. / 1 minute 1)
Fritting
No
Communication rate
1 Mbps ±0.01 %
Max. number of devices
32
Max. segment length without repeater
860 m
Characteristic impedance
120 Ω 2)
Connection points
4 × D-sub DE-9,
according to EN 61375-2-1:2012,
connector fixing by M3 bolt
Standard
EN 61375-2-1:2012
UIC CODE 556:2010 (Ed. 5.0)
1) Galvanic isolation must not be used for dangerous voltage separation.
2) Terminator is included in unit. Connection of terminator at end node is
provided automatically by unit firmware.
Number of interfaces
1
Operation indication
2 × LED (LNK and ACT)
Galvanic isolation
Yes, 1000 V AC. / 1 minute 1)
Data transmission rate
100 Mbps
Recommended cabling
STP CAT5
Maximum segment length
100 m
Connection point
M12 connector,
according to IEC 61375-3-4,
D-coding
1) Galvanic isolation must not be used for dangerous voltage separation.
Number of interfaces
2
Operation indication
2 × LED (RUN and ACT) 1)
Galvanic isolation
Yes, 1000 V AC. / 1 minute 2)
Data transmission rate
1 Mbps
Terminating resistor
120 Ω 3)
Recommended cabling
Shielded cable
Max. segment length without repeater
Typ. 1000 m / 50 kbps
Signal delay of physical layer loop
Maximum 390 ns
Connection points
2 × D-sub DE-9 connector (concatenation)
according to IEC 61375-3-3:2012 (Ed. 1.0),
connectors fix by UNC4-40 treaded bolt 1)
Standard
EN 61375-3-3:2012
CiA DS301
1) For each CAN line.
2) Galvanic isolation must not be used for dangerous voltage separation.
3) Terminators are not part of the delivery (see tab. Ordering information).
WTB
Note
Ethernet
Note
CAN
Note

RRU-WEC/1201
9/34 rru-wec1201_g_en_100
Nominal power supply voltage
24 V DC
Maximum power consumption
Max. 0.6 A 1)
Power supply voltage range
(permanent)
16.8 V DC to 30 V DC
Inrush current
Max. 15 A / < 1 ms 1)
Galvanic isolation
Yes, 1000 V AC. / 1 minute 2)
Connection point
Connector type D-sub 2W2C, socket
Connector counterpart
Connector type D-sub 2W2C, plug
Wire cross section
0.75 mm2to 4 mm2
1) Values are valid for nominal power supply voltage.
2) Galvanic isolation must not be used for dangerous voltage separation.
Mechanical design
Compact aluminium subrack, naturally
anodized
Front and rear panel made of aluminium
alloy with anti-corrosion surface finish 1)
Mounting
Into 19“ subrack
Ingress protection rate
IP30 2)
Weight –netto
–brutto
1.62 kg ±5 %
2.04 kg ±5 %
Dimensions in standard units (w × h)
28 HP × 3 U 3)
Dimensions (w × h × d)
(142 × 129 × 186) mm
Package dimensions (w × h × d)
(180 × 200 × 273) mm
1) Front panel is made from aluminium alloy without detail specifying of
additives composition. Surface is naturally anodized.
2) After all cable connectors are connected.
3) 1 HP (horizontal pitch) = 0.2 inch (5.08 mm),
1U (rack unit) = 1.75 inch (44.45 mm).
Unit overall mass of plastics
280 g
Included mass of self-extinguishing
plastics
280 g
Unit does not contain
PUR, PVC, Asbestos
Unit complies with
2011/65/EU (ROHS)
1907/2006EU (REACH)
Operating temperature range
-40 °C to +70 °C
Storage temperature range
-40 °C to +70 °C
Maximum ambient humidity
< 95 % non-condensing
Reliability (MTBF) min
180 000 with ambient temperature of 40 °C
None
Unit is supplied with loader, which enables software equipment downloading.
Unit is intended to operate up to 1 400 m above the sea level.
Unit is designed to meet the Temperature Class TX.
Power supply
Note
Mechanics
Note
Dangerous
materials
Temperatures
Others
Components
with reduced
lifetime
Software
equipment
Claims of EN
50155:2007

RRU-WEC/1201
rru-wec1201_g_en_100 10/34
According to EN 61373 standard, WTB gateway is classified in terms of vibrations
into Category 1, Class B (mounting to vehicle body).
Permissible supplying voltage drop-outs duration: max. 10 ms (Class S2 according to
Chapter 3.1.1.2 of EN 50155:2007).
For supply voltage switching are permissible conditions of C1 and C2 Class.
The device is not classified according to EN 50128:2011 Railway applications -
Communications, signalling and processing systems - Software for railway control
and protection systems.
The device is not classified according to EN 50129:2003 Railway applications –
Communication, signalling and processing systems –Safety related electronic
systems for signalling.
Safety
classification

RRU-WEC/1201
11/34 rru-wec1201_g_en_100
4.1. Dimensions
128,4
141,9 172,0
111,3
186,0
141,9
Obr. 1 - Physical dimensions of WTB gateway

RRU-WEC/1201
rru-wec1201_g_en_100 12/34
4.2. Recommended drawing symbol
Following drawing symbol is recommended for RRU-WEC/1201 WTB gateway.
Ethernet
M12
WTB A1
D-sub DE-9 M
WTB A2
D-sub DE-9 F
WTB B1
D-sub DE-9 M
CAN 1
D-sub DE-9 M
CAN 1
D-sub DE-9 F
WTB B2
D-sub DE-9 F
CAN 2
D-sub DE-9 M
CAN 2
D-sub DE-9 F
D-sub 2W2C, UNC 4-40
Vcc
GND
RRU-WEC/1201
X2
X3
X4
X5
X7
X8
X6
X9
X10
X1
1
2
Obr. 2 - Recommended drawing symbol

RRU-WEC/1201
13/34 rru-wec1201_g_en_100
4.3. Block diagram
FPGA
Power
supply
DDR2
WTB
interface
Ethrenet
interface
5 V
X2 X3 X4 X5 X6 X7 X8
WTB A1 WTB A2 WTB B1 WTB B2 CAN1 CAN1Ethernet
2.5 V
1.8 V
1.2 V
CAN
interface
X1
Power
24 V
Power
supply
5 V
X9 X10
CAN2 CAN2
CAN
interface
Obr. 3 - Block diagram of RRU-WEC/1201 WTB gateway

RRU-WEC/1201
rru-wec1201_g_en_100 14/34
4.4. Type label
The unit has a type label attached to its left side. Included data are summarized
in the table:
Description
Data
Note
–
Logo AMiT
Producer logo
–
QR code
Product QR code
TYPE
RRU-WEC/1201
Unit type designation
S/N
AB12345
Serial number
MAC
00-09-54-FF-FF-FF
MAC address
LDR
1.0
LOADER version number
POWER
24 V DC / 0.60 A
Power supply voltage
WEIGHT
1.62 kg
Weight
TEST
OK
Routine testing result
HiPot
HiPot-OK
HiPot test result
DATE
dd.mm.yyyy
Production date
–
Logo CE
Unit was assessed and complies with
EU legislative requirements
–
Crossed out dustbin logo with
a full stripe
The disposal of electronic equipment is
subject to the regulations on handling
electrical waste.
TYPE
S/N
MAC
LDR
POWER
WEIGHT
TEST
HiPot
DATE
RRU-WEC/1201
AA00000
00-09-54-0C-FF-FF
1.00
24 V DC / 0.6A
1.62 kg
OK-AM
HiPot-OK
01.04.2016
Obr. 4 - Illustrative example of type label
Example of
data on type
label

RRU-WEC/1201
15/34 rru-wec1201_g_en_100
TYPE
S/N
MAC
LDR
POWER
WEIGHT
TEST
HiPot
DATE
RRU-WEC/1201
AA00000
00-09-54-0C-FF-FF
1.00
24 V DC / 0.6A
1.62 kg
OK-AM
HiPot-OK
01.04.2016
Obr. 5 - Location of type label (illustrative picture)

RRU-WEC/1201
rru-wec1201_g_en_100 16/34
5. Conformity assessment
WTB gateway RRU-WEC/1201, provided it is used in accordance with this
manual, meets the requirements of NV616/2006 Czech governmental decree.
The conformity assessment has been carried out in accordance with
harmonized standard EN 50121-3-2:2006.
Tested in accordance
with standard
Type of test
Classificati
on
EN 55011:2009
Industrial, scientific and medical
equipment –Radio-frequency
disturbance characteristics –Limits and
methods of measurement
Complies
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3:Testing and measurement tech-
niques –Radiated, radio-frequency, elec-
tromagnetic field immunity test, 800 MHz
to 1000 MHz
Complies
(20 V/m)
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3:Testing and measurement
techniques - Radiated, radio-frequency,
electromagnetic field immunity test,
1000 MHz to 2100 MHz
Complies
(10 V/m)
EN 61000-4-3:2006
Electromagnetic compatibility (EMC) –
Part 4-3:Testing and measurement
techniques –Radiated, radio-frequency,
electromagnetic field immunity test,
2100 MHz to 2500 MHz
Complies
(5 V/m)
EN 61000-4-4:2012
Electromagnetic compatibility (EMC) –
Part 4-4:Testing and measurement
techniques –Electrical fast transient/burst
immunity test, power supply, WTB, CAN,
ETH
Complies
(±2 kV)
EN 61000-4-5:2006
Electromagnetic compatibility (EMC) –
Part 4-5:Testing and measurement
techniques –Surge immunity test, power
supply, conductor against ground
Complies
(±2 kV)
EN 61000-4-5:2006
Electromagnetic compatibility (EMC) –
Part 4-5:Testing and measurement
techniques –Surge immunity test, power
supply, between conductors
Complies
(±1 kV)
EN 61000-4-6:2009
Electromagnetic compatibility (EMC) –
Part 4-6:Testing and measurement
techniques –Immunity to conducted
disturbances, induced by radio-frequency
fields
Complies
(10 V)

RRU-WEC/1201
17/34 rru-wec1201_g_en_100
5.1. Other tests
RRU-WEC/1201 WTB gateway has been assessed and approved for use in
railway applications according to standards:
Tested in accordance
with standard
Type of test
Result
EN 50155:2007
Railway applications –Electronic
equipment used on rolling stock
Complies
EN 50121-3-2:2006
Railway applications –Electromagnetic
compatibility –Part 3-2:Rolling stock –
Apparatus
Complies
EN 61373:2010
Railway applications –Rolling stock
equipment –Shock and vibration tests
Category 1,
Class B
EN 61000-4-2:2009
Electromagnetic compatibility (EMC) –
Part 4-29:Testing and measurement
techniques –Voltage dips, short interrup-
tions and voltage variations on d.c. input
power port immunity tests
S2, C1, C2
EN 60068-2-1:2007
Environmental testing –Part 2-1:Tests –
Test A:Cold
Complies
EN 60068-2-2:2007
Environmental testing - Part 2-2:Tests –
Test B:Dry heat
Complies
EN 60068-2-30:2005
Environmental testing - Part 2-30:Tests –
Test Db:Damp heat, cyclic (12 + 12 hour
cycle).
Complies
EN 61375-2-1:2012
Electronic railway equipment –Train
communication network (TCN) –Part 2-
1:Wire Train Bus (WTB)
Complies
EN 61375-2-2:2012
Electronic railway equipment –Train
communication network (TCN) –Part 2-
2:Wire Train Bus conformance testing
Complies
EN 61375-3-3:2012
Electronic railway equipment –Train
communication network (TCN) –Part 3-
3:CANopen Consist Network (CCN)
Complies
UIC CODE 556:2010
(Ed 5.0)
Information transmission in the train (train
bus)
Complies
EN 45545-2:2013
Railway applications –Fire protection on
railway vehicles –Part 2: Requirements
for fire behaviour of materials and
components
HL3

RRU-WEC/1201
rru-wec1201_g_en_100 18/34
6. Power supply
WTB gateway RRU-WEC/1201 can be powered by 24 V DC from vehicle’s on-
board network.
6.1. Powering from DC network
Power supply voltage is connected to X1 D-sub 2W2 connector.
Obr. 6 - Power supply connector location
D-sub 2W2C connector
PIN
Signal
Description
1
Vcc
Power supply, +24 V DC
2
GND
Power supply, ground
PWR X1
connector
wiring

RRU-WEC/1201
19/34 rru-wec1201_g_en_100
7. Communication lines
7.1. WTB
WTB gateway RRU-WEC/1201 has a WTB interface with doubled line,
according to EN 61375-2-1:2012 standard.
Both lines are connected through D-sub DE-9 connectors. Connectors are fitted
with M3 threaded nuts, that prevents the cable falling off due to vibrations or to
be broken away.
Obr. 7 - Location of WTB line connectors
Connector type: D-sub DE-9, plug
Connector
PIN
Signal/Description
X3, X5
1
WTB line positive wire
2
WTB line negative wire
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
8
Not used
9
Not used
WTB line
connectors
wiring
54321
9876

RRU-WEC/1201
rru-wec1201_g_en_100 20/34
Connector type: D-sub DE-9, socket
Connector
PIN
Signal/Description
X4, X6
1
WTB line positive wire
2
WTB line negative wire
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
8
Not used
9
Not used
7.1.1 WTB line state indication
Indication of WTB line state is provided by 16 LEDs in the middle part of front
panel. Six of these LEDs in WTB A area indicate the state of line A. Six LEDs in
WTB B area indicate the state of line B and the remaining four LEDs indicate
the node state. Following table describes meaning of the individual LEDs:
Obr. 8 - LEDs front panel detail (WTB)
LED
Colour
Description
TL1
Green
Trusted Line, direction 1
TL2
Green
Trusted Line, direction 2
RX1
Green
Data reception from direction 1
RX2
Green
Data reception from direction 2
D1
Yellow
Disturbance, direction 1
D2
Yellow
Disturbance, direction 2
WMS
Green
Node is in Master composition
SLP
Green
Node is in Sleep Mode
END
Green
Node is in End Setting state
INT
Green
Node is in Intermediate Setting state
Description of
LED
12345
6789
Table of contents
Other Amit Gateway manuals

Amit
Amit CDW531AM User manual

Amit
Amit BTG771AM-0T1 User manual

Amit
Amit BDE702-001 User manual

Amit
Amit IOG761AM-0TDA1 User manual

Amit
Amit SDE852-00001 User manual

Amit
Amit IOG761-0TV21 User manual

Amit
Amit RRR-WTB/C User manual

Amit
Amit VHG760AM-0T001 User manual

Amit
Amit TE1088 User guide

Amit
Amit M2M IDG500-0T012 User manual

Amit
Amit RRU-WEM/1158 User manual

Amit
Amit RRU-WC/110x User manual

Amit
Amit IOG500AM-0T001 User manual

Amit
Amit VHG87B-0T1B0 User manual

Amit
Amit IOG761-0T001 User manual

Amit
Amit IDG470-0GT0C User manual

Amit
Amit ODG761AM-0T1 User manual

Amit
Amit IOG851-0T031 User manual

Amit
Amit ODG761AM-0T1 User manual

Amit
Amit ODG851-0TCP001 User manual