manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B-K lighting
  6. •
  7. Outdoor Light
  8. •
  9. B-K lighting DENALI User manual

B-K lighting DENALI User manual

Hot SurfaceHigh VoltageWarning
Standard Installation
DENALI
UPLIGHT - INTEGRAL
Flammable
5/64”, 9/64” & .050” Allen Wrench
Waterproof Wire Connectors
Silicone
TOOLS
NEEDED:
Proper soil preparation is recommended before installation. See the DIG-IT guide at
www.bklighting.com/collaterals/install/digit.pdf for more information.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
INSTRUCTIONS
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL
ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
RELEASE DATE
06/26/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2826-00
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
SAFETY AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before
replacing lamp/LED. Fixture gets HOT quickly!
Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
Use a soft cloth or gloves. Oil from skin may cause
damage.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
PVC Housing
Body
Faceplate
18/3 Ga. Wire
Surface Mount Collar
Surface mount uplights are intended for installation in
wood, pavers, stone, and other hardscapes.
Not recommended for concrete pour
installations.
INSTALLATION
4. Align holes to final installation orientation. Arrows
on temporary cover point towards screw location
on faceplate for alignment purposes.
NOTE: Do not remove temporary cover until
installation of faceplate.
2. Loop minimum of 6” of wiring inside housing to
allow for fixture service.
NOTE: Do not remove temporary cover!
3. Place housing into hole. Surface mount collar
should rest on finished surface grade.
NOTE: Do not remove temporary cover!
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
06/26/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2826-00
Standard Installation
DENALI
UPLIGHT - INTEGRAL
5” O.D.
5-1/2” O.D.
1. Drill 5” diameter hole into mounting surface at
uplight installation location as per lighting plan.
Do not exceed surface diameter, installation relies
on surface mount collar resting on surface grade.
Collar diameter is 5”. Surface mount flange is 5-1/2”
diameter
Pull primary 120v, branch circuit wiring.
Screws on faceplate will
align with alignment
arrows on temporary
cover
5. Use a silicone based sealant (not included) between
fixture and mounting surface.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
In-ground Installation Instructions
Soil Prep
Fixture Installation Surface Mount
RELEASE DATE
06/26/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2826-00
Conduit
trench
B. Dig hole 15” wide and 12” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.A. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.
Finished grade
12”
1. Excavate trench according to designed lighting
plan 12” deep and 15” wide suitable for the fixture
housing.
2. Supply primary 120v, branch circuit wiring
necessary for installation.
5. Align holes to final installation orientation. Arrows
on temporary cover point towards screw location
on faceplate for alignment purposes.
NOTE: Do not remove temporary cover until
installation of faceplate.
6. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with sand or
pea gravel for drainage.
NOTE: The mounting collar must be flush
to finished grade. Use stability flange to aid in
installation as shown. Fixture is provided with 5ft
leads.
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel or Sand
Finished Grade
Screws on faceplate will
align with alignment
arrows on temporary
cover
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel
Finished Grade Pavers Paver Sand
Soil
7. Fill with soil, then compress. Layer paver sand as
required for paver installation, then install pavers.
Pavers may need to be cut to fit around housing.
3. Slide stability flange onto housing.
NOTE: Product is supplied with a stability flange
to anchor fixture and aid in installation.
4. Loop minimum of 6” wire inside housing to allow
for fixture service. Place fixture in hole.
NOTE: Do not remove temporary cover!
Standard Installation
DENALI
UPLIGHT - INTEGRAL
8. Remove temporary cover and pull out primary 120V,
branch circuit wiring.
In-ground installation instructions
Finished grade
Wire nuts must
clear opening
6”
min.
9. Access primary 120V, branch circuit wiring inside
housing. Make watertight connections using
waterproof wire connectors (not included). Wire
connectors must clear opening. Insert fixture,
wiring and connections into housing. See wiring
diagram.
10. Mount faceplate to collar using two (2) #8-32 flat
head screws (included) with a 9/64” allen wrench.
LINE
GROUND GROUND FIXTURE
COM
LINE
COM
WIRING DIAGRAM
Pull branch circuit wiring. Make watertight
connections from branch circuit wiring to fixture
leads using waterproof wire connectors (not
included) in splice location as per NEC. UL Listed
splice location required. Connect incoming green
ground wire to ground wire from fixture. See wiring
diagram.
All line voltage connections must be made in
compliance with the National Electrical Code.
Failure to do so will void warranty.
Standard Installation
DENALI
UPLIGHT - INTEGRAL
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
06/26/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2826-00
LINE UP WITH THE HOLE
Fixture Re-lamping
This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular
LED components with quick disconnects simplifies upgrades and maintenance when necessary.
1. Remove faceplate from collar using (2) #8-32
faceplate screws with a 9/64” allen wrench.
2. Remove fixture from collar. 3. Loosen three (3) #8-32 set screws with a 5/64”
allen wrench to remove cap from fixture body.
5. Remove retainer4. Twist and pull away optic.
10. Connect new driver assembly to fixture leads. Place
connections inside body cavity, then slide down
fixture body along guides.
6. Disconnect driver assembly from fixture body.
7. Separate heatsink from driver assembly via quick
disconnect.
8. Remove protective plastic from the double-sided
tape square on clean top of driver assembly.
9. Reconnect heatsink assembly to driver assembly
via quick disconnect. Quick disconnect tucks into
space underneath heatsink. Press heatsink down
along guides until flush and even with tape on
driver.
11. Reinstall Retainer
Standard Installation
DENALI
UPLIGHT - INTEGRAL
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
06/26/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2826-00

Other B-K lighting Outdoor Light manuals

B-K lighting ALPINE Series User manual

B-K lighting

B-K lighting ALPINE Series User manual

B-K lighting GARDEN STAR User manual

B-K lighting

B-K lighting GARDEN STAR User manual

B-K lighting Well Star WS Series User manual

B-K lighting

B-K lighting Well Star WS Series User manual

B-K lighting CO2 User manual

B-K lighting

B-K lighting CO2 User manual

B-K lighting MB2 User manual

B-K lighting

B-K lighting MB2 User manual

B-K lighting EC Setup guide

B-K lighting

B-K lighting EC Setup guide

B-K lighting HP2 SERIES User manual

B-K lighting

B-K lighting HP2 SERIES User manual

B-K lighting Yukon Bollard User manual

B-K lighting

B-K lighting Yukon Bollard User manual

B-K lighting CK User manual

B-K lighting

B-K lighting CK User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting Litestick User manual

B-K lighting

B-K lighting Litestick User manual

B-K lighting Precision 2 CO2 Series User manual

B-K lighting

B-K lighting Precision 2 CO2 Series User manual

B-K lighting PS User manual

B-K lighting

B-K lighting PS User manual

B-K lighting OLYMPUS Series User manual

B-K lighting

B-K lighting OLYMPUS Series User manual

B-K lighting HP2RM User manual

B-K lighting

B-K lighting HP2RM User manual

B-K lighting CATSKILL Series User manual

B-K lighting

B-K lighting CATSKILL Series User manual

B-K lighting GARDEN STAR GR-K User manual

B-K lighting

B-K lighting GARDEN STAR GR-K User manual

B-K lighting ARTISTAR UPLIGHT User manual

B-K lighting

B-K lighting ARTISTAR UPLIGHT User manual

B-K lighting Precision2 DR2 Series User manual

B-K lighting

B-K lighting Precision2 DR2 Series User manual

B-K lighting HP2 SERIES User manual

B-K lighting

B-K lighting HP2 SERIES User manual

B-K lighting PM4RM ROUND CAMLOCK Setup guide

B-K lighting

B-K lighting PM4RM ROUND CAMLOCK Setup guide

B-K lighting TENAYA2 Series User manual

B-K lighting

B-K lighting TENAYA2 Series User manual

B-K lighting BKSSL MINI-MICRO iLUME User manual

B-K lighting

B-K lighting BKSSL MINI-MICRO iLUME User manual

B-K lighting SARATOGA Series User manual

B-K lighting

B-K lighting SARATOGA Series User manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.