manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Beninca
  6. •
  7. Control Unit
  8. •
  9. Beninca DA.AX User manual

Beninca DA.AX User manual

Other Beninca Control Unit manuals

Beninca THINK-I User manual

Beninca

Beninca THINK-I User manual

Beninca BRAIN 24 User manual

Beninca

Beninca BRAIN 24 User manual

Beninca Start User manual

Beninca

Beninca Start User manual

Beninca CP.M24-RE User manual

Beninca

Beninca CP.M24-RE User manual

Beninca DREAM User manual

Beninca

Beninca DREAM User manual

Beninca HEADY 24 3B User manual

Beninca

Beninca HEADY 24 3B User manual

Beninca CP.B24-SW User manual

Beninca

Beninca CP.B24-SW User manual

Beninca CP.BISON OTI User manual

Beninca

Beninca CP.BISON OTI User manual

Beninca DA.C15 User manual

Beninca

Beninca DA.C15 User manual

Beninca CORE User manual

Beninca

Beninca CORE User manual

Beninca CP.B24ESA User manual

Beninca

Beninca CP.B24ESA User manual

Beninca BRAINY User manual

Beninca

Beninca BRAINY User manual

Beninca SA.02 User manual

Beninca

Beninca SA.02 User manual

Beninca BRAINY User manual

Beninca

Beninca BRAINY User manual

Beninca CP.RI624N User manual

Beninca

Beninca CP.RI624N User manual

Beninca Logica 230 User manual

Beninca

Beninca Logica 230 User manual

Beninca THINK User manual

Beninca

Beninca THINK User manual

Beninca CP.MS4 User manual

Beninca

Beninca CP.MS4 User manual

Beninca Brain 24 MBE User manual

Beninca

Beninca Brain 24 MBE User manual

Beninca CP.J4 ESA User manual

Beninca

Beninca CP.J4 ESA User manual

Beninca SA.03 Head User manual

Beninca

Beninca SA.03 Head User manual

Beninca DA.AXE User manual

Beninca

Beninca DA.AXE User manual

Beninca CORE User manual

Beninca

Beninca CORE User manual

Beninca BRAINY 24 User manual

Beninca

Beninca BRAINY 24 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DA.AX
CENTRALINA A MICROPROCESSORE
CONTROL UNIT WITH MICROCONTROLLER
MIKROCONTROLLER-STEUERUNG
CENTRALE A MICROCONTRÔLEUR
CENTRALITA A MICROPROCESADOR
AUTOMATISMI PER CANCELLI
®
L8542605
Rev. 07/00/01
Libro istruzioni
Operating instructions
Betriebsanleitung
Livret d’instructions
Libro de instrucciones
UNIONE NAZIONALE COSTRUTTORI
AUTOMATISMI PER CANCELLI, PORTE,
SERRANDE ED AFFINI
A
Z
I
E
N
D
A
C
E
R
T
I
F
I
C
A
T
A
UNI
EN ISO
9001
2
Dichiarazione CE di conformità Déclaration CE de conformité
EC declaration of confirmity Declaracion CE de conformidad
EG-Konformitatserklarung
Con la presente dichiariamo che il nostro prodotto
We hereby declare that our product
Hiermit erklaren wir, dass unser Produkt
Nous déclarons par la présente que notre produit
Por la presente declaramos que nuestro producto
DA.AX
è conforme alle seguenti disposizioni pertinenti:
complies with the following relevant provisions:
folgenden einschlagigen Bestimmungen entspricht:
correspond aux dispositions pertinentes suivantes:
satisface las disposiciones pertinentes siguientes:
Direttiva sulla compatibilità elettromagnetica (89/336/
CCE, 93/68/CEE)
EMC guidelines (89/336/EEC, 93/68/EEC)
EMV-Richtlinie (89/336/EWG, 93/68/EWG)
Directive EMV (89/336/CCE, 93/68/CEE) (Compatibilité
électromagnétique)
Reglamento de compatibilidad electromagnética (89/336/
MCE, 93/68/MCE)
Norme armonizzate applicate in particolare:
Applied harmonized standards, in particular:
Angewendete harmonisierte Normen, insbesondere:
Normes harmonisée utilisées, notamment:
Normas armonizadas utilzadas particularmente:
EN 55022, EN 61000-3-2, EN 61000-3-3, EN 50082-1
Norme e specifiche tecniche nazionali applicate in
particolare:
Applied national technical standards and specifications, in
particular:
Angewendete nationale Normen und technische
Spezifikationen, insbesondere:
Normes et specifications techniques nationales qui ont été
utilisées, notamment:
Normas y especificaciones técnicas nacionales que se
utilizaron particularmente:
UNI 8612
Data/Firma
Direttiva sulla bassa tensione (73/23/CEE, 93/68/CEE)
Low voltage guidelines (73/23/EEC, 93/68/EEC)
Tiefe Spannung Richtlinie (73/23/EWG, 93/68/EWG)
Directive bas voltage (73/23/CEE, 93/68/CEE)
Reglamento de bajo Voltaje (73/23/MCE, 93/68/MCE)
Norme armonizzate applicate in particolare:
Applied harmonized standards, in particular:
Angewendete harmonisierte Normen, insbesondere:
Normes harmonisée utilisées, notamment:
Normas armonizadas utilzadas particularmente:
EN 60204-1, EN 60335-1
Data/Firma
AUTOMATISMI PER CANCELLI
®
Automatismi Benincà Srl
Via Scamozzi, 3
36030 MONTECCHIO P. VI
ITALIA
3
TRF1
FF1
FF1
VDR2
R18 D1 TCA
FF4
J1
J3
INPUT
230VAC MANT.
OUT
24VAC
+V
FTC
FCA
FCC
P.P.
CHIUDE
1
F N
COM. APRE CHIUDE
2 3 4 5 6 7 8 9 10 11 12 13 14 15
J2
FF3
DA.AX
SW1
C15
v1.0
X1
R21
R19
R1
R2
R20
R3
C1
U6 U4
U3
C9
C2
C8
R28
D2
6.3A
VDR1 VDR3
RL1
COMUNE
RL2
APRE
RL3
CHIUDE
VDR4
POWER
+
C3
1 Funz. P.P.
2 Rich. Aut.
3 Funz. Cond.
4 P.P./Apre
+
C6 C10
Q2
Q1
U1
U2
R8 R6
R7
R9
+TL
250mA
F2
C4
R5
R4
R23
C5
C7
C13
R15
R11
R16
R12
R17
R13
R14
R10
Z5
Z1
Z2
Z3
C12
C11
C14
R22
Z4
FUSE
F1
FUSE
6
DA.AX Control unit with microcontroller
The microprocessor control unit “DA.AX” can be used with motors having a power not exceeding 500W.
Installation instructions.
a) The electrical installation and functioning logic must comply with current standards.
b) It is advisable to keep the power cables (motor, power supply) detached from the control cables
(push-buttons, photocells, radio). In order to avoid any possible interference it is recommended
to provide for and use two separate sheaths (see EN 60204-1 15.1.3).
c) Before powering the unit, check again all connections which have been carried out.
d) Check the correct presettings of the Dip-Switches.
e) When the unit is powered, the LED “POWER” must be lit; in the negative, check fuses and that
230Vac 50Hz power supply is present between terminals 1 and 2 (INPUT 230VAC - keep to
phase / neutral).
f) The N.C. inputs not used must be connected to the common “+V”.
g) Should the direction of rotation of the motor be reversed, invert the motor wires “OPEN” with
“CLOSE” and the limit switches wires “FCA” with “FCC”.
Input/Output functions
(1,2) INPUT 230VAC= Control unit 230Vac 50 Hz power supply
(respect phase/neutral wire position).
(3,4,5) COM/APRE/CHIUDE= Connection to the corresponding 230Vac 50 Hz motor terminals
(the earth wire (green/yellow) must be connected to the motor housing).
(6,7) OUT 24VAC= 24Vac auxiliary power supply output (100mA max.).
(12) +V= Common connection to all the control inputs.
(9) FTC= Photocell receiver input (n.c. contact).
(10) FCA= Input of limit switch APRE (n.c. contact).
(11) FCC= Input of limit switch CHIUDE (n.c. contact).
(8) P.P.= Input, “PASSO-PASSO” push button or “APRE” push-button according to the Dip-Switch
presetting
(15) CHIUDE= CLOSE button input (n.o. contact).
(13,14) ANT.= Input of radio board antenna
Dip-switch functions
N.B.: Every change of functions have to be done without electricity.
DSW1= This selects the type of functioning of the P.P. button and Remote control.
Off= ”APRE” - ”STOP” - ”CHIUDE” functioning
On= ”APRE” - ”CHIUDE” - ”APRE” functioning.
DSW2= This enables or disables the automatic re-closing - ”TCA TRIMMER”.
Off= Automatic re-closing enabled
On= Automatic re-closing disabled
DSW3= This enables or disables the apartment building function (after the first opening command, the
P.P. button and the Remote control are deactivated).
7
Off= Apartment building function disabled.
On= Apartment building function enabled.
DSW4= It selects the operation of the “P.P.” input as push-button “PASSO-PASSO” or push-button
“APRE”.
Off= “P.P.” push-button
On= “APRE” push-button
Trimmer functions
TCA= This allows the automatic re-closing time to be adjusted when this is enabled by positioning the
DSW2 Dip-switch on OFF.
Adjustment can be from a minimum of 5 to a maximum of 150 seconds.
The minimum time is obtained by rotating the trimmer completely clockwise.
TL= This allows the working time of the automation to be adjusted. If the limit switches fail, the soft-
ware protection will intervene after this time has elapsed. (Add about 4 sec. to the actual stroke
time of the automation).
Adjustment can be from a minimum of 7 to a maximum of 180 seconds.
The minimum time is obtained by rotating the trimmer completely clockwise.
Note
• The ”STOP” control can be carried out by connecting the normally closed push button between the
common wire of the limit switch and the ”+V” terminal (see drawing).
• If the ”P.P.” input is used as ”APRE” (Dip-switch 4= ON), the automatic closure is not carried out until
the contact remains closed.
+V
FTC
FCA
FCC
STOP button
Limit switch buttons
AUTOMATISMI PER CANCELLI
®