manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bosch
  6. •
  7. Security Sensor
  8. •
  9. Bosch ISC-BPR2-WP12 User manual

Bosch ISC-BPR2-WP12 User manual

Other Bosch Security Sensor manuals

Bosch ISM-BLD1 User manual

Bosch

Bosch ISM-BLD1 User manual

Bosch Blue Line Q1 User manual

Bosch

Bosch Blue Line Q1 User manual

Bosch D-tect 150 SV Professional User manual

Bosch

Bosch D-tect 150 SV Professional User manual

Bosch DS938Z Series User manual

Bosch

Bosch DS938Z Series User manual

Bosch FAA-500 User manual

Bosch

Bosch FAA-500 User manual

Bosch FAA-420-RI-ROW User manual

Bosch

Bosch FAA-420-RI-ROW User manual

Bosch ISP-PPR1-WA16K User manual

Bosch

Bosch ISP-PPR1-WA16K User manual

Bosch DS935Z User manual

Bosch

Bosch DS935Z User manual

Bosch DM-TP-50(80) User manual

Bosch

Bosch DM-TP-50(80) User manual

Bosch ISN-SM-50 User manual

Bosch

Bosch ISN-SM-50 User manual

Bosch VMD01 M50 PAL User manual

Bosch

Bosch VMD01 M50 PAL User manual

Bosch DS1109i User manual

Bosch

Bosch DS1109i User manual

Bosch WEU PDO 6 User manual

Bosch

Bosch WEU PDO 6 User manual

Bosch DS778 User manual

Bosch

Bosch DS778 User manual

Bosch DS308EA User manual

Bosch

Bosch DS308EA User manual

Bosch FAP-420 Series Owner's manual

Bosch

Bosch FAP-420 Series Owner's manual

Bosch ISW-ZPR1-WP13 User manual

Bosch

Bosch ISW-ZPR1-WP13 User manual

Bosch TriTech+ ISC-PDL1-WA18G User manual

Bosch

Bosch TriTech+ ISC-PDL1-WA18G User manual

Bosch ISC-PPR1-WA16G User manual

Bosch

Bosch ISC-PPR1-WA16G User manual

Bosch DS940 User manual

Bosch

Bosch DS940 User manual

Bosch ISC-BDL2-WP6 User manual

Bosch

Bosch ISC-BDL2-WP6 User manual

Bosch TriTech DS950 Series User manual

Bosch

Bosch TriTech DS950 Series User manual

Bosch GMS 120 User manual

Bosch

Bosch GMS 120 User manual

Bosch ISN-AP1-T User manual

Bosch

Bosch ISN-AP1-T User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© 2010 Bosch Security Systems, Inc. F.01U.140.812 | 05 | 2010.12 | 1
Ligue todas as cablagens apenas a um circuito de
segurança de tensão extra baixa (SELV).
NOTE:
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
UL/C-UL
Perform Walk Test at least once a year.
Pet immunity not tested by UL/C-UL.
Use only a Listed limited-power source.
The Listed control unit or a Listed burglary power supply must provide 4
hours (40 mAh) of standby power.
Install the unit in accordance with National Electrical Code NFPA 70 and
Part 1 of the Canadian Electrical code CSA C22.1.
Sluit alle bedrading uitsluitend aan op een
circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à un
circuit à très basse tension de sécurité (TBTS).
Alle Drähte sind ohne Ausnahme an
Niederspannung anzuschließen.
Collegare tutti i cavi esclusivamente a un circuito
SELV (circuito di sicurezza a bassissima tensione).
EN 50131-2-2 Grade 2
EN 50130-5 Environmental Class II
IP30 IK04 (EN 60529, EN 50102)
0 - 95% Relative Humidity
(0 - 85% UL/C-UL installations)
-30°C to +55°C
(-20°F to +130°F )
UL Listed installations,
the temperature
range is 0°C to +49°C
(+32°F to +120°F)
Pour les installations
certifiées NFA2P,
Température de
fonctionnement
-10°C à +55°C
Conecte el cableado únicamente a un circuito
de seguridad para voltajes muy bajos (SELV).
SELV
Connect all wiring to a safety extra-low voltage (SELV) circuit only. Changes or modifications not expressly approved
by Bosch Security Systems, Inc. can void the
user’s authority to operate the equipment.
Optional Brackets:
B328, B338, B335
US Patent No.
5,670,943
2
1
1 2 3 4
2,2 m - 2,75 m
(7.5 ft - 9 ft)
Recommended:
2,2 m (7.5 ft)
Pet Friendly
≤ 20 kg (45 lb)
Blue Line Gen2
Pet Friendly PIR
Motion Detector
ISC-BPR2-WP12
© 2010 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA F.01U.140.812 | 05 | 2010.12 | 2
+
-
TTNC NC-+
+
-
9-15 Vcc
10 mA @ 12 Vcc en veille/
en alarme, source limitée en
puissance, ondulation
résiduelle 1 V.
10 mA (0.12W) @ 12 VDC
9 - 15 VDC
≤ 100 mA, 25 VDC, 2.5 W
<20 Ω closed
5 6
7
2 min
8 9
Non-pet
Applications
Only
44 mm
(1.7 in)
61 mm
(2.4 in)
105 mm
(4.2 in) www.boschsecurity.com
?→