manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Burkert
  6. •
  7. Control Unit
  8. •
  9. Burkert 0420 User manual

Burkert 0420 User manual

Other Burkert Control Unit manuals

Burkert 2106 User manual

Burkert

Burkert 2106 User manual

Burkert 8681 User manual

Burkert

Burkert 8681 User manual

Burkert 2030 User manual

Burkert

Burkert 2030 User manual

Burkert 3280 User manual

Burkert

Burkert 3280 User manual

Burkert 2101 User manual

Burkert

Burkert 2101 User manual

Burkert 1134 User manual

Burkert

Burkert 1134 User manual

Burkert 2100 series Guide

Burkert

Burkert 2100 series Guide

Burkert 2712 Series User manual

Burkert

Burkert 2712 Series User manual

Burkert 2300 Series User manual

Burkert

Burkert 2300 Series User manual

Burkert 2060 User manual

Burkert

Burkert 2060 User manual

Burkert 6012 User manual

Burkert

Burkert 6012 User manual

Burkert 2060 User manual

Burkert

Burkert 2060 User manual

Burkert EPS 22 ATEX 1 136 X User manual

Burkert

Burkert EPS 22 ATEX 1 136 X User manual

Burkert 6106 User manual

Burkert

Burkert 6106 User manual

Burkert 2103 Series User manual

Burkert

Burkert 2103 Series User manual

Burkert 2103 Series User manual

Burkert

Burkert 2103 Series User manual

Burkert 2064 User manual

Burkert

Burkert 2064 User manual

Burkert 8640 User manual

Burkert

Burkert 8640 User manual

Burkert 2012 User manual

Burkert

Burkert 2012 User manual

Burkert 2101 User manual

Burkert

Burkert 2101 User manual

Burkert 2103 Series User manual

Burkert

Burkert 2103 Series User manual

Burkert 6213 User manual

Burkert

Burkert 6213 User manual

Burkert 2006 User manual

Burkert

Burkert 2006 User manual

Burkert 3360 User manual

Burkert

Burkert 3360 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Operating Instructions Type 0420
Marking (example):
Body Material
PL = Polyamide Plastic
Seal Material
NBR = NBR
FKM = FKM
Circuit Function
G = 4-way
Recorder No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4
or General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6
or FM approved as
Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4A
UL listed for Ordinary locations
CSA approved for Ordinary locations
See label on the valve.
Operating Instructions 0605/08_EU-EN_00893139
Table 1 Seal materials
Fluid Tempera-
tures [°F] Buna "N" (B) FKM (F)
Air Fluid T.
Ambient + 14 to + 122
+ 14 to + 122 + 14 to + 122
+ 14 to + 122
Neutral
gas Fluid T.
Ambient + 14 to + 122
+ 14 to + 122 + 14 to + 122
+ 14 to + 122
Design:
4-way solenoid valve, internally piloted, in the de-energized
condition port P connected to port B and port R connected to
port A. With manual override and flow restrictors.
Seal Materials and Fluids handled:
See Table1.
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table1.
Pressure Range:
Minimum pressure differential between inlet and outlet port is
35 PSI.
Maximum inlet pressure see label on valve.
Installation:
Installation position as required. Ensure exhaust outlets for
pilot valve and main valve remain unrestricted but protect
against entry of dust, water and foreign matter. Pipework
should be clean. Do not put any loads on coil unit. Pipework
should be supported and installed to prevent strain on valve
body. Fittings should be sealed with PTFE tape, max. torque
80 in-lbs. Mounting is accomplished by means of two M4 self-
locking threaded brass inserts located on the valve
underside. Maximum thread depth is 6 mm.
Operating Instructions
Wiring Diagram
Electrical Connection Type 2509
Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label.
Voltage tolerance is ± 10 %.
Available Electrical Connections see “Marking”.
Wiring diagram see above.
For this product to be considered UL-listed and CSA approved
for General Purpose and FM approved for Hazardous Locations
Division 2, it must be in conjunction with the type 2509 cable plug
connector (Electrically Operated Valves Parts, YSYI2).
The connector and gasket must be assembled to the valve with the
screw provided after the connection of the wire leads. This valve
and connector assembly is delivered together and is to be used as
one unit.
For valves to be used in Intrinsically Safe Applications the positive
pole is identified by a “+” on the pin or wire No. 1 has to be con-
nected to the “+”.
See Control Drawing for the Rules of Interconnection.
Warning:
All valves to be used in Intrinsically Safe Applications must be
clearly marked as Intrinsically Safe Apparatus.
Trouble-Shooting:
Check port connections, minimum operating pressure differential
if required and supply voltage. Ensure pilot hole in piston is clear
and pilot bore in the valve outlet is not abstracted. If core does not
pull in, check for short circuit, coil burn-out or foreign matter im-
peding core movement. A jammed or missing core causes the coil
to overheat in the case of AC supply.
Warning:
These products are designed to operate in a wide variety of ap-
plications, it is the user’s responsibility to select a model that is
appropriate for the application. This product is designed to be
installed only by suitably qualified and trained personnel.
Specifications should not be exceeded under any circumstances.
The torque for the terminal screw on type 2509 is 0,5 Nm
(4,4 lbf-in.).
Changes made to this product will render any applicable warranty
null and avoid.
Specifications subject to change without notice.
Any questions? Please call Bürkert Contromatic Technical Service
at (949) 223 31 00.
Power*
Power*
Ground (green dot)
* Orientation is not important
Germany
Contact address:
Bürkert Fluid Control Systems
Sales Center
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]
International
Contact addresses can be found on the Internet at:
www.burkert.com Bürkert Company Locations