5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with the current standards and regulations.
N.B.: The cable section, with different lengths from those shown on the table, must be considered on the basis the actual draw of the
connected devices, according to what is prescribed in the CEI EN 60204-1 Code.
For connections that require varying loads on the same line (i.e. sequential), the table values should be reconsidered depending on
the actual draws and distances.
5.3 Cable list and minimum thickness
Connections Type of cable Length of cable 1 < 10 m Leng. of cable 10 < 20 m Leng. of cable 20 < 30 m
Control panel power supply 230V 2F
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm23G x 2,5 mm23G x 4 mm2
Motor power supply 230V 3 x 1 mm23 x 1,5 mm23 x 2,5 mm2
Flashing light 24V 2 x 0,5 mm22 x 1 mm22 x 1,5 mm2
Photocell transmitters 2 x 0,5 mm22 x 0.5 mm22 x 0,5 mm2
Photocell receivers 4 x 0,5 mm24 x 0,5 mm24 x 0,5 mm2
Accessories power supply 24V 2 x 0,5 mm22 x 0,5 mm22 x 1 mm2
Control and safety devices
2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Endpoints 3 x 0,5 mm23 x 1 mm23 x 1,5 mm2
Antenna connection RG58 max. 10 m
1) Gearmotor
2) Control panel
3) Radio receiver
4) Photocells
5.4 Standard installation
7
1
1
2344 5
44
6
7
8
5) Keyswitch
6) Antenna
7) Flashing light
8) Transmitter