CAS DB-II User manual

9002-DB2-VF33-3
2006. 07
Bench Scale
OWNER’S MANUAL
(VFD Ver.)
DB-

CONTENTS
PRECAUTIONS 4
PREFACE 6
NAMES AND FUNCTIONS 6
OPERATIONS 8
1. General Weighing 8
2. Weighing with Tare 8
3. Counting Mode 9
4. Percent Weighing Mode 10
5. Hold Function 11
6. Cumulative Weight Sum 11
7. Weight Comparison Function(HI/OK/LOW) 13
8. Print Out 16
SETUP MODE 17
1. How to Go to Setup Mode 17
2. Setup Mode Table 17
3. How to Enter Date 18
4. How to Enter Time 19
ERROR MESSAGES 20
SERIAL INTERFACE 20
SPECIFICATIONS 21
HOW TO INSTALL DB - Series 22

5
4
For consistent and accurate reading,
maintain periodical check by your
CAS authorized dealer.
Avoid sudden shock to the scale.
Internal mechanism could be damaged.
Take the battery out when scale is not in
use for long time. Leakage from the
batteries is hazardous.
Place the scale on firm and temperature
consistent environment.
Keep the scale away from other
electromagnetic generating devices.
This may interfere with accurate
reading.
Grab on the bottom of the scale when
moving. Do not hold by the platter.
By adjusting 4 corners of the scale, set
the scale even using the built in scale
leveling indicator.
Attention
Do not disassemble the scale.
When any damage or
defect occurs, contact
your CAS authorized
dealer immediately for
proper repair.
Do not overload beyond the maximum
weight limit.
Do not pull the plug by its cord when
unplugging. Damaged cord could cause
electric shock or fire.
To prevent from fire occurring, Do not
place or use the scale near
flammable or corrosive
gas.
Avoid placing the scale near heater
or in direct sunlight.
Scale must be grounded to minimize
electricity static. This will minimize
defect or electric shock.
Do not step up on the scale with wet feet.
Platter becomes slippery. Humid
condition may cause incorrect
reading.
Use proper Adapter. Incorrect adapter
could damage the scale.
Insert plug firmly to wall outlet to
prevent electric shock.
To reduce electric shock or incorrect
reading, Do not spill water on the scale
or place it in humid condition.
Warning
PRECAUTIONS
Precautions when installing the scale. To ensure that you get the most from
yourscale,pleasefollowtheseinstruction.
Make sure to plug your scale into the proper power outlet. For maximum
performance,plugintoapoweroutlet30minutesbeforetheusageforwarmup.

7
6
PREFACE
NAMES AND FUNCTIONS
Thank you for purchasing our CAS DB- series scale.
These series have been designed with CAS reliability, under rigid quality control
and with outstanding performance. Your specialty departments can enjoy these
high quality reliable CAS products.
We believe that your needs will be satisfied and you will have reliability.
This manual will help you with proper operation and care of the DB- series.
Please keep this handy for future reference.
OVERALL VIEW
DISPLAY AND KEYBOARD
KEY FUNCTIONS
Esc
Used to set the zero point to 0.00.
Used as an ESC key in Setup Mode.
Used to enter a tare weight and used to cancel a tare weight.
Used to convert the mode as below.
[kg] [pcs] [%] [WEIGHT LIMIT ON/OFF]
[COUNT LIMIT ON/OFF] [kg]
Used as an ENTER key.
Used to calculate a unit weight of a sample.
[] Used to enter next digit.
Used to display average weight.
[] Used to have number up.
DESCRIPTIONSKEYS
PLATTER
LEVELING GAUGE
DISPLAY
KEYBOARD
ADJUSTING BOLT
<Post Type> <Wall Type>

If you want to increase sample size, press the SAMPLE key.
The display shows 10, 20, 30, 40, 50, 100, 150 and 200 every
time pressing the SAMPLE key.
If you set sample size to 10, place 10 samples on the platter.
3. Counting Mode
If you want to count parts, first you have to set sample size.
Press the MODE key until the display shows “PCSSET”. Make
sure that COUNT lamp is on. If you have set sample size before,
the display shows “0”.
Press the SAMPLE key, then
the display shows “10”.
or
9
2. Weighing with Tare
Tare is the weight of container being used for a commodity.
The TARE key subtracts the weight of the container.
Place the container on the
platter. Press the TARE key, NET
lamp is on. Place an item in the
container.
To release the TARE function,
remove an item and container
from the platter and press the
TARE key.
1. General Weighing
The display indicates if the scale is at zero or if there is a tare entered into the
scale by way of a ZERO and NET.
OPERATIONS
Turn on the power.
The display shows 0.00.
Make sure that STABLE and
ZERO lamps are on.
When the display is not zero
though there is nothing on
the platter, press the ZERO
key.
Place an item on the platter.
When the STABLE lamp is
on, read the weight.
8
POWER
PRINT key.
[] Used to have number down.
Used to turn ON or OFF the power.
DESCRIPTIONSKEYS

6. Cumulative Weight Sum
The function of cumulative weight sum is to be showing the aggregate times and
weight as adding the value of weighing a several times. Even though power is
off, the scale stores data. This function is only available in weighing mode.
Place an item on the platter. To add this weight, press the
SAMPLE key. Make sure that
SUM lamp is on.
To release HOLD function, press the HOLD key or remove the item from the
platter.
If the scale judges that the weight of the sample varies above 1/4 weight, it
will be released the hold automatically.
5. Hold Function
Place an item on the platter and then press the HOLD key.
“HOLD” is shown on the
display. Average weight is shown on
the display
11
4. Percent Weighing Mode
The weight is displayed as a percentage of the reference.
or
Press the MODE key until the display shows “PErSEt”. If you
have set reference sample before, the display shows “0.0”. If you want to use container,
place it and press the TARE
key.
Place reference sample on the platter and press the SAMPLE key.
The display shows “100.0”.
(LCD version:The display shows “100.0%”)
Make sure that reference sample should be bigger than 3% of
maximum capacity. If it is lower than 3% of maximum capacity,
the display shows “LOW”. In this case, increase the weight of
reference sample and press the SAMPLE key.
Place an item on the platter, then the weight is displayed as a
percentage of the reference.
Place parts on the platter, then the display shows the number of
parts. You can also use tare function in counting mode.
10
Press the SET key. The display shows unit weight and then shows the number of samples. If the
display shows “LACK”, the counting result may not correct. (LCD version:Lack of Unit lamp is On) If
the display shows “LOW”, it is impossible to count samples because the unit weight is too small.
(Refer to Table 1)
Model DB-II 60kg
DB-II 150kg DB-II 300kg
Range of Lack 10g Lack 1g 20g Lack 1g 50g Lack 1g
Range of Low 1g Low 1g Low 1g Low
Table 1

If you set up LOW/HIGH limit wrong, “WL ERR” will be shown on the display. Then you have to set it
up again. For example) LOW=100.00kg HIGH=90.00kg High limit is lower than Low limit.
Press the MODE key to go to weighing mode.
Press the SET key, the
display shows “WL ON”.
Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the SAMPLE
key.
Press the SET key to set up
high value, the display
shows “H000.00”.
Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
13
You can delete cumulative weight sum or aggregate times. Press the SET key to display cumulative
weight sum or aggregate times and then press the ZERO(ESC key).
To print out cumulative weight sum, press the SET key to display cumulative weight sum or aggregate
times and then press the PRINT key.
7. Weight Comparison Function(HI/OK/LOW)
7-1. How to compare weight
Press the MODE key until
the display shows “WL OFF”.
It means that weight limit
function is deactivated.
Press the HOLD key to
activate this function, the
display shows “WL ON”.
Press the SET key to set up
low value, the display shows
“L000.00”.
To cancel last added weight, press the SET key to display cumulative weight sum or aggregate times
and then press the SAMPLE key. The display shows “S SUB”.
12
The display shows cumulative weight sum and aggregate times every time pressing the SET key.
The SUM key is flashed.

15
Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
Press the SET key, the
display shows “H00000”. Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
If you set up LOW/HIGH limit wrong, “CL ERR” will be shown on the display. Then you have to set it
up again. For example) LOW=00100, HIGH=00090 or LOW=00100, HIGH=00100
Press the MODE key to go to weighing mode.
Suppose that the High limit of 200 and the Low limit of 80 are set up. In this condition, OK lamp is
lighted on if the weight is 120, HI lamp is lighted on if the weight is 220 and if the weight is 60,
LO lamp is lighted on. It beeps as fixed on User Setup Mode.
(Refer to Setup Mode Table on page 17)
Press the SET key, the
display shows “CL ON”.
7-2. Counting comparison function
Press the MODE key until
the display shows “CL OFF”.
It means the counting
comparison function is
deactivated.
Press the HOLD( ) key to
activate this function, the
display shows “CL ON”.
Press the SET key, the
display shows “L00000”.
14
Suppose that the High limit of 70kg and the Low limit of 30kg are set up. In this condition, OK lamp is
lighted on if the weight is 40kg, HI lamp is lighted on if the weight is 80kg and if the weight is 20kg,
LO lamp is lighted on. It beeps as fixed on User Setup Mode.
(Refer to Setup Mode Table on page 17)

17
1. How to Go to Setup Mode
Make sure that power is OFF. While pressing the PRINT key, press the POWER
key. The display shows “U SEt”. You can select each menu by pressing the
MODE key and change the setting by pressing the HOLD or PRINT key. If you
press SET key, you will save current setting and finish this mode. To finish this
mode without saving, press the ZERO key.
SETUP MODE
8-2. Auto print
To use auto print function, you have to set printer menu to “Pr AUt” in setup mode.
Refer to Setup Mode Table on page 17.
If the weight is stable, it is printed out automatically.
16
8. Print Out
8-1. Manual Print
You can print out data every time pressing the PRINT key. You can setup
print function depends on your need. Refer to Setup Mode Table on page 17.
Sample format:
-Weighing Function- -Counting Function-
======== WEIGHT ========
WELCOME TO CAS[DB-2] CAS
2000-00-00 00:00:00
Weight : 0.000 kg
- WEIGHT LIMIT SET VALUE -
Limit(H): 40.000 kg
Limit(L): 30.000 kg
======== WEIGHT ========
WELCOME TO CAS[DB-2] CAS
2000-00-00 00:00:00
Weight : 40.180 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight :
-
40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
Weight : 40.200 kg
--------------------------------
Total : 401.980 kg
Count : 10 times
======== COUNT ========
WELCOME TO CAS[DB-2] CAS
2000-00-00 00:00:00
Weight : 40.200 kg
U/Weight : 0.80400 kg
Quantity : 50 pcs
- COUNT LIMIT SET VALUE -
Limit(H): 2000 pcs
Limit(L): 1000 pcs
Label Caption
Date/Time
-
means that you cancel the weight right before
this weight.
Cumulative weight sum
Aggregate times
2. Setup Mode Table
MENU DISPLAY DESCRIPTIONS
Buzzer “ b on ” You can hear buzzer.
“ b oFF ” You cannot hear buzzer.
“ Pr oFF ” Do not use printer.
Printer “ Pr kEy ” Manual print.
“ Pr AUt ” Auto print when the scale is stable.
“ Pr CMd ” For future.
“ br 48 ” 4,800 bps
Baud Rate “ br 96 ” 9,600 bps
“ br 192 ” 19,200 bps
“ br 384 ” 38,400 bps
“ WL M0 ” HIGH Limit Weight LOW Limit - You will hear buzzer.
“ WL M1 ” HIGH Limit Weight, Weight LOW Limit
Weight Limit - You will hear buzzer.
“ WL M2 ” Weight LOW Limit - You will hear buzzer.
“ WL M3 ” HIGH Limit Weight - You will hear buzzer.
“ CL M0 ” HIGH Limit Counting result LOW Limit
- You will hear buzzer.
“ CL M1 ” HIGH Limit Counting result,
Count Limit Counting result LOW Limit - You will hear buzzer.
“ CL M2 ” Counting result LOW Limit - You will hear buzzer.
“ CL M3 ” HIGH Limit Counting result - You will hear buzzer.
-Cumulative Weight Sum Function-

Press the SAMPLE( ) key
to set up time, “00,00,00”
is shown on the display.
Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
Press the SET key to save.
“tisave” is shown on the
display.
If you do not want to save time, press the ZERO key.
19
Press the SAMPLE( ) key,
the display shows
“00,00,00”.
Press the HOLD( ) or
PRINT( ) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
Press the SET key to save.
“dysave” is shown on the
display and then the display
shows a day of the week.
You can change the day by
pressing the HOLD( ) or
PRINT( ) key. If you set up
a day of the week wrong,
“Wk err” is shown on the
display.
Press the SET key to save.
“Wksave” is shown on the
display.
If you do not want to save,
press the ZERO key.
4. How to Enter Time
Press the MODE key until the
display shows “ti ON”. It
means that time is printed
out.
If you do not want to print out time, press the HOLD( ) key.
3. How to Enter Date
Press the MODE key until the
display shows “dy ON”. It
means that date is printed out.
If you do not want to print out date, press the HOLD( ) key.
18
Italic Bold: Default Setting
MENU DISPLAY DESCRIPTIONS
Date “ dy on ” Print out date/day.
“ dy oFF ” Do not print out date/day.
Time “ ti on ” Print out time.
“ ti oFF ” Do not print out time.
Label “ LA off ” Do not print out label caption.
“ LA on ” Print out label caption.
Default “ dF no ” Default setting is released.
“ dF YES ” Everything is setup in default.

21
ERROR MESSAGES
An error of the initial ZERO range
Failure of analog module
An error of EEPROM
Condition codes are broken
1. Make sure the platter is empty.
2. Make sure there is a platter on the
scale.
Call your CAS dealer
Call your CAS dealer
Call your CAS dealer
ERROR REASONS SOLUTIONS
Err 1
Err 10
Err 11
Err 12
SERIAL INTERFACE
GND
GND
Rx
Tx
Rx
Tx
PC or
Printer TYPE 1
Scale
D-Sub
Connector(9 pin) D-Sub
Connector(9 pin)
20
MODEL
CAPACITY
MAX.TARE
INTERNAL RESOLUTION
EXTERNAL RESOLUTION
DISPLAY
DISPLAY LAMP
INTERFACE
POWER SOURCE
TEMPERATURE RANGE
PLATTER SIZE (W DH)mm
PRODUCT SIZE (W DH)mm
WEIGHT
DBII-60 DBII-150 DBII-300
30kg/0.01kg 60kg/0.02kg 150kg/0.05kg
60kg/0.02kg 150kg/0.05kg 300kg/0.1kg
59.98kg 149.95kg 299.9kg
1/120,000 1/150,000 1/150,000
1/3,000
VFD 6DIGIT
STABLE, ZERO, HOLD, NET, HI/OK/LO, %, PCS, SUM, kg
RS-232C(Printer)
AC 230V/50Hz
10°C 40°C
420 510 110 500 640 120
420 635 765 500 725 765
12.7kg 24.6kg
VFD Version
SPECIFICATIONS
Notice: Specifications are subject to change for improvement
without notice.

22
HOW TO INSTALL DB-II Series MEMO
1. Open the box with care because indicator is connected to the scale with
load cell wire.
2. Turn the post knob so as to fix indicator.
3. Pull down the wire out of post pipe and insert the post pipe to the post
bracket. (Refer to fig. 1)
4. Fasten the post pipe with two bolts. (Refer to fig. 1)
A long bolt should be connected to the upper side.
5. Insert the wire to the post pipe. (Refer to fig. 2, 3)
6. If the scale is not properly level, please adjust 4 leg(adjusting bolt) at the
bottom of the scale so as to center the bubble of the leveling gauge.
Note : Place the scale on a flat and stable surface.
Inside the indicated circle.
INDICATOR
FIG.1
LOAD CELL WIRE
POST BRACKET
LEVELING GAUGE
PLATFORM
ADJUST
POST KNOB
POST PIPE
BOLT
FIG.2
FIG.3
POST PIPE
POST BRACKET
WIRE
23
Table of contents
Other CAS Scale manuals