PACKAGE CONTENT
Magnetic
lock Armature
plate
5x16
Roll pin Steel washer Rubber
washer M5x8
Screw
111122221188
M8x35
Screw M8x25
Screw Cap nut
Joggle
bracket
Manual
1111112211
PRODUCT PRESENTATION
Monitored
Flush mount
High corrosion resistance
Delivered with armature plate
No mechanical wear
No residual magnetism
Ease of installation
Recommended for interior use
Fail safe (Door unlocked when power off)
Holding force: 300kg
Built-in varistor: Built-in electronic protection to
eliminate back EMF
Dimensions (L x W x D): 228 x 36 x 27 mm
Armature plate dimensions (L x W x D): 185 x 38 x 11 mm
Power supply: 12-24V dc
Consumption: 480 mA @ 12V dc
240 mA @ 24V dc
CE CerticationWEEE & RoHSIP42
MOUNTING RECOMMENDATIONS
OPTIONAL ACCESSORIES
References AMB300
DescriptionDescription For armature plateFor armature plate
ELECTRICAL CONNECTIONS
Armature plate
- It is vital that the magnetic lock and armature
plate are securely xed to their supports.
- The magnetic lock and the armature plate must
be aligned.
- The armature plate must be mounted “oating”
around the central mounting screw to
compensate for any misalignment of the door
CDVI_V3E36R_IM_01_EN-FR_A4_B - G0301FR1079V01 - 04/21- All the information contained within this document (photos, drawing, features, specications and dimensions) could be perceptibly different and can be changed without prior notice.
CDVI FRANCE + EXPORT
31, av. du Général Leclerc
93500 PANTIN - France
Phone +33 (0)1 48 91 01 02
www.cdvi.com
CDVI SWEDEN
[SWEDEN - DENMARK -
NORWAY FINLAND]
Phone +46 (0)31 760 19 30
www.cdvi.se
CDVI UK
[UNITED KINGDOM - IRE-
LAND]
Phone +44 (0)1628 531300
www.cdvi.co.uk
CDVI AMERICAS
[CANADA - USA]
Phone +1 (450) 682 7945
www.cdvi.ca
CDVI BENELUX
[BELGIUM - NETHERLAND -
LUXEMBOURG]
Phone +32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI SUISSE
Phone +41 (0)21 882 18 41
www.cdvi.ch
CDVI IBÉRICA
[SPAIN - PORTUGAL]
Phone +34 (0)935 390 966
www.cdviberica.com
CDVI ITALIA
Phone +39 0321 90 573
Fax: +39 0321 90 8018
www.cdvi.it
10
WARRANTY
YEAR
The NO/NC signal only switches when
the door is closed with the power to it on.
12V dc Default setup
Terminal
block Correspondence
+12 or 24V dc
-0V
N.C NC (Normally closed)
COM COM
N.O NO (Normally open)
CDVI TAIWAN
Phone +886 (0)42471 2188
www.cdvichina.cn
CDVI CHINA
Phone +86 10 84606132/82
www.cdvichina.cn
CDVI MAROC
Phone +212 5 2248 0940
www.cdvi.ma
CDVI POLSKA
Phone +48 12 659 23 44
www.cdvi.com.pl
CDVI GERMANY
+49 (0) 175 2932 901
www.cdvi.de
www.cdvi.com
VoltageVoltage
12V dc ADC335 ADC612S
24V dc24V dc ADC324 ADC624S
Recommended power supplies
Voltage selection jumpers
12V dc 24V dc
- Check the jumper position before connecting
the lock to the input current. A wrong position
could damage the lock. This type of damage
is not covered by the warranty.
- Make sure that the magnet and the armature
meet evenly over their entire mating surfaces.
The Armature plate must be able to pivot
slightly about its center mounting screw
to compensate for any door misalignment.
IMPORTANT NOTE
250 1010
0,25
9,5 19 9,5
38 0,25
11,520511,5
228
M5
11
192
23
3
2,5
38
185
9
185x38x11mm
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3ER
C.A. :
F0525000002-B
Surface condition: Ra 3,2
General tolerance:
0.2
Material : Aluminium
DES.: W. Sainvil
A3H
SCALE 1:2
Date 27/05/2020
Edition 00
Plan M2536-ens
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
M5 ScrewM5 Screw
Armature plateArmature plate
MaglockMaglock
Joggle bracketJoggle bracket
M8 ScrewM8 Screw
Rubber washerRubber washer
Cap nutCap nut
Steel washerSteel washer
250 1010
0,25
9,5 19 9,5
38 0,25
11,520511,5
228
M5
11
192
23
3
2,5
38
185
9
185x38x11mm
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3ER
C.A. :
F0525000002-B
Surface condition: Ra 3,2
General tolerance:
0.2
Material : Aluminium
DES.: W. Sainvil
A3H
SCALE 1:2
Date 27/05/2020
Edition 00
Plan M2536-ens
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
11
3
20,5
205
35,5
185
215
235
10 10
185
38
9
SCALE 1:2
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3E35R
C.A. :
F0525000012
-A
Surface condition: Ra 3,2
General tolerance:
0.2
Material :
DES: W.Sainvil
A3H
SCALE 1:1.5
Date 16/03/2021
Edition 02
Plan M2469
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
11
3
20,5
205
35,5
185
215
235
10 10
185
38
9
SCALE 1:2
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3E35R
C.A. :
F0525000012
-A
Surface condition: Ra 3,2
General tolerance:
0.2
Material :
DES: W.Sainvil
A3H
SCALE 1:1.5
Date 16/03/2021
Edition 02
Plan M2469
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
Roll pinRoll pin
Manufacturing Access Control since 1985
V3E36R
Ventouse électromagnétique encastrée
300 kg
FR
ÉLÉMENTS INCLUS
Ventouse
encastrée Contre-plaque
Goupille
5x16 Vis
M5X8 Rondelle
acier Rondelle
caoutchouc
111122882211
Vis
M8x35 Vis
M8x25 Écrou borgne
Plaque de
mise en
afeurement
Notice
1111112211
PRÉSENTATION DU PRODUIT
Signal
Encastrée
Résistance à la corrosion
Livrée avec contre-plaque
Pas d’usure mécanique
Pas de magnétisme résiduel
Facilité d’installation
Préconisée en intérieur
Libère l’accès en cas de coupure de courant
Force de rétention : 300kg
Varistance incorporée : Protection électronique intégrée
contre l’effet de self
Dimensions (L x l x P) : 228 x 36 x 27 mm
Dimensions contre-plaque (L x l x P) : 185 x 38 x 11 mm
Alimentation : 12-24V DC
Consommation : 480 mA en 12V DC
240 mA en 24V DC
Certication CEDEEE & RoHSIP42
RECOMMANDATIONS DE MONTAGE
ACCESSOIRES EN OPTION
Références AMB300
DescriptionDescription Pour contreplaquePour contreplaque
RACCORDEMENTS
Contre-plaque
- Il est vital de xer solidement la ventouse et la
contreplaque sur leurs supports.
- La ventouse et la contre-plaque doivent être
impérativement alignées.
- La contre-plaque doit être montée “ottante”
autour de la vis centrale de montage pour
compenser un mauvais alignement de la porte.
CDVI_V3E36R_IM_01_EN-FR_A4_B - G0301FR1079V01 - 04/21 - Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques techniques et dimensions) peuvent varier et sont susceptibles de modications sans notication préalable.
CDVI FRANCE + EXPORT
31, av. du Général Leclerc
93500 PANTIN - France
Phone +33 (0)1 48 91 01 02
www.cdvi.com
CDVI SWEDEN
[SWEDEN - DENMARK -
NORWAY FINLAND]
Phone +46 (0)31 760 19 30
www.cdvi.se
CDVI UK
[UNITED KINGDOM - IRE-
LAND]
Phone +44 (0)1628 531300
www.cdvi.co.uk
CDVI AMERICAS
[CANADA - USA]
Phone +1 (450) 682 7945
www.cdvi.ca
CDVI BENELUX
[BELGIUM - NETHERLAND -
LUXEMBOURG]
Phone +32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI SUISSE
Phone +41 (0)21 882 18 41
www.cdvi.ch
CDVI IBÉRICA
[SPAIN - PORTUGAL]
Phone +34 (0)935 390 966
www.cdviberica.com
CDVI ITALIA
Phone +39 0321 90 573
Fax: +39 0321 90 8018
www.cdvi.it
10
WARRANTY
YEAR
CDVI TAIWAN
Phone +886 (0)42471 2188
www.cdvichina.cn
CDVI CHINA
Phone +86 10 84606132/82
www.cdvichina.cn
CDVI MAROC
Phone +212 5 2248 0940
www.cdvi.ma
CDVI POLSKA
Phone +48 12 659 23 44
www.cdvi.com.pl
CDVI GERMANY
+49 (0) 175 2932 901
www.cdvi.de
www.cdvi.com
Le signal NO/NF ne commute que lorsque
la porte fermée et sous tension.
Réglage usine 12V DC
Bornier Correspondance
+12 ou 24V DC
-0V
N.C NF
(Normalement fermé)
COM COM
N.O NO
(Normalement ouvert)
TensionTension
12V DC ADC335 ADC612S
24V DC24V DC ADC324 ADC624S
Alimentations recommandées
Cavaliers de sélection de tension
12V DC 24V DC
- Vérier la position du cavalier avant de brancher
la ventouse au courant d’entrée. Une position
incorrecte peut endommager la ventouse. Ce type
de dommage n’est pas couvert par la garantie.
- La ventouse et la contre-plaque doivent être
impérativement alignés.
La contre-plaque doit être montée “ottante”
autour de la vis centrale de montage pour
compenser un mauvais alignement de la porte.
NOTE IMPORTANTE
250 1010
0,25
9,5 19 9,5
38 0,25
11,520511,5
228
M5
11
192
23
3
2,5
38
185
9
185x38x11mm
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3ER
C.A. :
F0525000002-B
Surface condition: Ra 3,2
General tolerance:
0.2
Material : Aluminium
DES.: W. Sainvil
A3H
SCALE 1:2
Date 27/05/2020
Edition 00
Plan M2536-ens
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
Vis M5Vis M5
Contre-plaqueContre-plaque
VentouseVentouse
Plaque de mise en Plaque de mise en
afeurementafeurement
Vis M8Vis M8
Rondelle caoutchoucRondelle caoutchouc
Écrou borgneÉcrou borgne
Rondelle acierRondelle acier
250 1010
0,25
9,5 19 9,5
38 0,25
11,520511,5
228
M5
11
192
23
3
2,5
38
185
9
185x38x11mm
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3ER
C.A. :
F0525000002-B
Surface condition: Ra 3,2
General tolerance:
0.2
Material : Aluminium
DES.: W. Sainvil
A3H
SCALE 1:2
Date 27/05/2020
Edition 00
Plan M2536-ens
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
11
3
20,5
205
35,5
185
215
235
10 10
185
38
9
SCALE 1:2
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3E35R
C.A. :
F0525000012
-A
Surface condition: Ra 3,2
General tolerance:
0.2
Material :
DES: W.Sainvil
A3H
SCALE 1:1.5
Date 16/03/2021
Edition 02
Plan M2469
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
11
3
20,5
205
35,5
185
215
235
10 10
185
38
9
SCALE 1:2
Weight (g) :
Vol. (mm
3
)
:
Project :
Mortice electromagnetic lock - 300kg
V3E35R
C.A. :
F0525000012
-A
Surface condition: Ra 3,2
General tolerance:
0.2
Material :
DES: W.Sainvil
A3H
SCALE 1:1.5
Date 16/03/2021
Edition 02
Plan M2469
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax
: 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
Roll pinRoll pin

Other CDVI Lock manuals

CDVI C3S11 User manual

CDVI

CDVI C3S11 User manual

CDVI BO800RN User manual

CDVI

CDVI BO800RN User manual

CDVI V3SR1248 User manual

CDVI

CDVI V3SR1248 User manual

CDVI V3SR User manual

CDVI

CDVI V3SR User manual

CDVI V3ER User manual

CDVI

CDVI V3ER User manual

CDVI V5SR User manual

CDVI

CDVI V5SR User manual

CDVI V1ER User manual

CDVI

CDVI V1ER User manual

CDVI V4ER User manual

CDVI

CDVI V4ER User manual

CDVI GARH User manual

CDVI

CDVI GARH User manual

CDVI PROFIL100EINT User manual

CDVI

CDVI PROFIL100EINT User manual

CDVI V1ER User manual

CDVI

CDVI V1ER User manual

CDVI V1SR User manual

CDVI

CDVI V1SR User manual

CDVI V5SR User manual

CDVI

CDVI V5SR User manual

CDVI SM300 User manual

CDVI

CDVI SM300 User manual

CDVI C3S11 User manual

CDVI

CDVI C3S11 User manual

CDVI V4SR User manual

CDVI

CDVI V4SR User manual

CDVI V3E32 User manual

CDVI

CDVI V3E32 User manual

CDVI PWM25ER User manual

CDVI

CDVI PWM25ER User manual

CDVI V1SR User manual

CDVI

CDVI V1SR User manual

CDVI V5NU User manual

CDVI

CDVI V5NU User manual

CDVI I300ER User manual

CDVI

CDVI I300ER User manual

CDVI V1SR User manual

CDVI

CDVI V1SR User manual

CDVI I180SR User manual

CDVI

CDVI I180SR User manual

CDVI BO600EVO User manual

CDVI

CDVI BO600EVO User manual

Popular Lock manuals by other brands

Siemens 3VA5 125 operating instructions

Siemens

Siemens 3VA5 125 operating instructions

Salto KPB22 Series quick start guide

Salto

Salto KPB22 Series quick start guide

Assa Abloy OneSystem 819N Quick manual

Assa Abloy

Assa Abloy OneSystem 819N Quick manual

Schlage B664 installation instructions

Schlage

Schlage B664 installation instructions

Assa Abloy hes 8000 Series installation instructions

Assa Abloy

Assa Abloy hes 8000 Series installation instructions

Schlage B80 installation instructions

Schlage

Schlage B80 installation instructions

Stanley QEL 200 installation instructions

Stanley

Stanley QEL 200 installation instructions

Stock Loks CB-191 instruction sheet

Stock Loks

Stock Loks CB-191 instruction sheet

COMPX SW20-3118MC Dimensional drawing

COMPX

COMPX SW20-3118MC Dimensional drawing

Von Duprin 2227 Series installation instructions

Von Duprin

Von Duprin 2227 Series installation instructions

LEHMANN DIAL LOCK 59 operating instructions

LEHMANN

LEHMANN DIAL LOCK 59 operating instructions

Assa Abloy Corbin Russwin TL3700 Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin TL3700 Series installation instructions

ABH 6600-B-AB Series Installation

ABH

ABH 6600-B-AB Series Installation

COMPX Timberline CB-280 instruction sheet

COMPX

COMPX Timberline CB-280 instruction sheet

M-LOCKS ML6740 operating instructions

M-LOCKS

M-LOCKS ML6740 operating instructions

Aurus PN-16 user manual

Aurus

Aurus PN-16 user manual

Allegion Olivari PT Series installation instructions

Allegion

Allegion Olivari PT Series installation instructions

Speakman CPT-1000-TP instructions

Speakman

Speakman CPT-1000-TP instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.