* Voir conditions de garantie à vie limitée. / Refer to Limited Lifetime Warranty.
Lecteur double technologie Proximité/Digicode® - Wiegand
Range: Integrated Access Control /
Dual Technology Digicode®/Proximity Reader - Wiegand
Gamme : Contrôle d’Accès Intégré
Group Products

FR
MANUEL D’INSTALLATION
2cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
Double technologie :
Proximité et/ou Digicode®
Wiegand 26, 30 ou 44 bits.
Clavier codé sensitif.
Connexion directe à la centrale ou via
le contrôleur de porte (INTBUSW).
Signalisation lumineuse et sonore.
Disponible en version : blanc ou noir.
Dimensions (H x L x P) : 130 x 90 x 35 mm.
Technologie : 125 Khz.
Protocole : lecteur multi-carte - Marin/HD.
Alimentation : 12 V DC.
Consommation : 100 mA.
1] PRÉSENTATION PRODUIT
3] ÉLEMENTS FOURNIS
2] RAPPELS ET RECOMMANDATIONS
Joint
d’étanchéité Vis TF
3x30 Cheville plastique
S5 Embout tournevis
TORX®
Vis TORX®
3x8 Varistance
GAMME SOLARKP
1 2 2 1 1 1
Certifi cation CE
Certifi cation FCC CFR 47
part 15 compliance
DEEE IP53 -25°C à +70°C
Programmation de la double sécurité
MODE
SYSTEME DIGICODE PROXIMITÉ DOUBLE TECHNOLOGIE
TELACCESS ✔ ✔ ✔
TERENA ✔ ✔ -
CENTAUR ✔ ✔ ✔
ATRIUM ✔ ✔ -
Rappel de câblage
- Programmez votre installation au préalable avant
de l’installer sur site.
- Dans le cas d’une connexion aux centrales
CENTAUR, ATRIUM ou d’une connexion
à un contrôleur de porte (INTBUSW) la distance
avec le lecteur doit être de 50 m maximum.
- La distance entre la centrale ou platine jusqu’au
dernier contrôleur de porte (INTBUSW) peut
atteindre 1200 m maximum.
- Attention de ne pas passer vos fi ls à proximité
de câbles «Courant fort» (ex: 230 V AC).
- Câbles préconisés entre le SOLARKPW-SOLARKPB
et l’interface BUS (INTBUSW) : Câbles 4 paires
SYT1 8/10ème (AWG 20).
Montage
Afi n d’optimiser la fi xation du SOLARKPW-SOLARKPB
et de prévenir les tentatives d’arrachage,
privilégiez les surfaces planes.
Recommandations d’installation
Pour sécuriser l’installation, n’oubliez pas de :
- placer la varistance sur le système de verrouillage,
en parallèle, au niveau de l’alimentation.
- placer une résistance de 120 ohms, entre A et B,
sur la dernière INTBUSW du BUS RS485.
Composition des codes
- Par soucis de sécurité, veillez à modifi er le code
maître usine par celui de votre choix.
- Lors du changement du code maître usine
et de la création des codes utilisateurs, évitez
les codes trop simples (ex: les suites 3 4 5 6 7).
Alimentations préconisées
ARD12 et BS60. Nos
alimentations sont
conforme aux exigences de la norme EN60950-1 :
2006/A11 :2009 et construite pour être une
alimentation limitée en puissance.

FR
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
MANUEL D’INSTALLATION
3
cdvi.com
cdvigroup.com
4] MONTAGE 5 RACCORDEMENTS CONNEXION DIRECTE
Raccordement aux borniers
des centrales
Format Wiegand
Bornier Sorties
Format Wiegand
CTV900A
ATRIUM
+Alimentation
12 V DC +12V 12V
-Alimentation 0V R1/0V
R2/0V GND
BCommande
extérieur du buzzer OUT5
OUT6 BUZ
D0 DATA 0 R1/D0
R2/D0 D0
D1 DATA 1 R1/D1
R2/D1 D1
HCLOCK - -
VVOYANT VERT OUT1
OUT3 GRN
RVOYANT ROUGE OUT2
OUT4 RED
Monter
impérativement
le joint
d’étanchéité
6] RACCORDEMENTS CONNEXION AVEC CONTRÔLEUR DE PORTE (INTBUSW)
6] FONCTIONNEMENT
Mise sous tension
- Voyant vert pendant 1 seconde.
- Voyant rouge pendant 1 seconde.
- Voyant bleu pendant 1s avec Bip pendant 1s.
Fonctionnement
- Activation Buzzer par niveau 0 V.
- Activation voyants par niveau 0 V.
Mode standard
- Badge lu : voyant orange et bip pendant 0,15 seconde puis
retour suivant état activation en cours.
1
R V B D1D0 H - +
Commande des voyants
Voyant vert Voyant rouge Etat
OFF OFF éteint
OFF ON rouge
ON OFF vert
ON ON bleu
SOLARKPW - SOLARKPB INTBUSW
+Alimentation 12V DC 12
-Alimentation 0V V
BCommande du buzzer 7
D0 Data 0 1
D1 Data 1 3
HClock 2
VVoyant vert 8
RVoyant rouge 9

FR
MANUEL D’INSTALLATION
4cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
7] FORMAT DE SORTIE WIEGAND 26 BITS
Chronogrammes 0 LOGIQUE
\DATA1
\CLOCK
\DATA0
1 LOGIQUE
50
µS 50
µS
2MS 2MS
Interfaçage
- La communication s’effectue par une liaison de type Wiegand 26 bits (Format 26 bits hexadécimal).
- Signaux : DATA1, DATA0 et CLOCK. Sortie des signaux en collecteur ouvert (avec pulls up interne de 2.2K au +5V)
La trame est constituée d’une totalité de 26 bits et se décompose comme suit :
- 1ère parité : 1 bit – parité paire des 12 bits suivants. Code clavier : 3 mots d’un octet représentant
le code tapé. Chaque mot est transmis bit de poids fort en premier.
- 2ème parité : 1 bit – parité impaire des 12 bits précédents.
Bit 1 Bit 2 … bit 25 Bit 26
Parité paire sur bit 2… bit13 Donnée (24 bits)
Parité impaire sur bit 14… bit 25
KEYPAD CODE
Exemple avec un code clavier à 4 termes: « 1 3 7 A » puis « B » et « 1 3 7 5 » puis « B »
1 0000 0000 0001 0011 0111 0101 0
Direct
Parité 1 0 0 1 3 7 A Parité 2
Hexadécimal
Parité 1 0 0 0 5 5 F Parité 2
Exemple avec un code clavier à 5 termes: « 7 1 3 7 A » puis « B » et « 7 1 3 7 5 » puis « B »
Direct
Parité 1 0 7 1 3 7 A Parité 2
Hexadécimal
Parité 1 0 1 1 6 C F Parité 2
Exemple avec un code clavier à 6 termes: « 6 7 1 3 7 A » puis « B » et « 6 7 1 3 7 5 » puis « B »
Direct
Parité 1 6 7 1 3 7 A Parité 2
Hexadécimal
Parité 1 0 A 3 E 8 F Parité 2
- Parité 1 : «0» si le nombre de 1 dans bit 2 à bit 13 est paire, «1» si le nombre de 1 dans bit 2 à bit 13 est impaire.
- Parité 2 : «0» si le nombre de 1 dans bit 14 à bit 25 est impaire, «1» si le nombre de 1 dans bit 14 à bit 25 est paire.
CODE BADGE EX: 0F01198AAD
Parité 1 1 9 8 A A D Parité 2

FR
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
MANUEL D’INSTALLATION
5
cdvi.com
cdvigroup.com
8] FORMAT DE SORTIE WIEGAND 30 BITS
Structure et description du message
- Format 30 bits hexadécimal.
- La communication s’effectue par une liaison de type Wiegand 30 bits ( Signaux: DATA1 et DATA0 )
La trame est constituée d’une totalité de 30 bits et se décompose comme suit :
- Parité 1 : 1 bit – parité paire des 14 premiers bits. Code : 7 quartets représentant le code du badge.
Chaque mot est transmis bit de poids fort en premier.
- Parité 2 : 1 bit – parité impaire des 14 derniers bits
Bit 1 Bit 2 à bit 29 Bit 30
Parité paire sur bit 2…bit 15 Donnée (28 bits)
Parité impaire sur bit 16… bit 29
CODES CLAVIER + BADGE
Exemple: Badge 0F01198AAD + Code clavier 6 termes: « 6 7 1 3 7 5 » puis « B ».
1 0001 0001 1001 1000 1010 1010 1101 0
BADGE Parité 1 1 1 9 8 A A D Parité 2
CODE
CLAVIER
Direct
Parité 1 0 6 7 1 3 7 5 Parité 2
Hexadécimal
Parité 1 0 0 A 3 E 8 F Parité 2
- Parité 1 : «0» si le nombre de 1 dans bit 2 à bit 15 est paire, «1» si le nombre de 1 dans bit 2 à bit 15 est impaire.
- Parité 2 : «0» si le nombre de 1 dans bit 16 à bit 29 est impaire, «1» si le nombre de 1 dans bit 16 à bit 29 est paire.
9] FORMAT DE SORTIE WIEGAND 44 BITS
Structure et description du message :
- Format 44 bits hexadécimal.
- La communication s’effectue par une liaison de type Wiegand 44 bits ( Signaux: DATA1, DATA0 et CLOCK).
La trame est constituée d’une totalité de 30 bits et se décompose comme suit :
Bit 1 à bit 40 Bit 41 à bit 44
Code badge LRC
CODES CLAVIER + BADGE
Exemple: Badge 0F01198AAD + code clavier 8 termes :
« 6 7 1 3 7 5 » puis« B »
0000 1111 0000 0001 0001 1001 1000 1010 1010 1101 ...
BADGE 0 F 0 1 1 9 8 A A D LRC
CODE
CLAVIER
Direct
0000671375LRC
Hexadécimal
0 0 0 0 0 A 3 E 8 F LRC

FR
MANUEL D’INSTALLATION
6cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
10] PARAMÉTRAGE DES VOYANTS SUR LE SYSTÈME CENTAUR
11] PARAMÉTRAGE DES VOYANTS SUR LE SYSTÈME ATRIUM*
PARAMÉTRAGE
VOYANT VERT
PARAMÉTRAGE
VOYANT ROUGE
ÉTAT VOYANTS :
VERT
ACCÈS AUTORISÉ
ROUGE
ACCÈS REFUSÉ
BLEU
EN ATTENTE
ÉTAT VOYANTS
VERT
ACCÈS AUTORISÉ /
ROUGE
ACCÈS REFUSÉ /
BLEU
EN ATTENTE
ACCÈS AUTORISÉ
ACCÈS REFUSÉ
* En mode Digicode® seul ou mode Proximité seul.

FR
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
MANUEL D’INSTALLATION
7
cdvi.com
cdvigroup.com
*Voir conditions de garantie à vie limitée
12] CONDITIONS DE GARANTIE À VIE LIMITÉE [EXTRAIT]*
Les sociétés CDVI garantissent que ce produit est dépourvu de tout vice caché, tant dans les matériaux
que dans sa fabrication, à la condition, qu’il soit installé conformément aux préconisations du fabricant
et qu’il n’y ait pas eu d’interventions ou de modifi cations sur le produit. La responsabilité de CDVI se limite
à la réparation ou à l’échange du produit. CDVI n’assume aucune responsabilité concernant les dommages
sur les biens ou les personnes. Un produit reconnu défectueux par CDVI doit être retourné au service-
après-vente de CDVI, après l’obtention du numéro d’autorisation de Retour de Produit(s) Défectueux (RMA).
La responsabilité de CDVI se limite à la réparation ou au remplacement d’un produit ou pièces défectueuses,
en ses ateliers. L’une ou l’autre de ces interventions sont défi nis par le service-après-vente de CDVI.
Le préjudice imputable à CDVI ne saurait en aucun cas dépasser la valeur du produit. La responsabilité
de CDVI ne peut être engagée auprès de l’acheteur, installateur, client fi nal ou qui que ce soit, lors de dommages
consécutifs à des imperfections ou mauvais fonctionnement du produit. Cette garantie prend effet
à la date d’enregistrement du produit auprès de CDVI, à partir de l’instant ou la date d’enregistrement est
dûment complétée, dans la limite d’un mois, après la date de livraison au client fi nal. Pour obtenir les dé-
tails complets de cette garantie et enregistrer votre/vos produit(s) pour bénéfi cier de cette « Garantie à Vie
limitée ». Veuillez compléter la carte d’enregistrement présente dans la boite du produit et nous la retourner,
par email ou par courrier, à l’adresse de l’entité CDVI la plus proche ou vous enregistrer en ligne à l’adresse
www.cdvigroup.com. Les contacts des entités CDVI sont accessibles en ligne à l’adresse www.cdvigroup.com
ou au dos de la notice d’installation.
EXCLUSIONS DE LA GARANTIE : A l’EXCEPTION DES POINTS EVOQUES PRECEDEMMENT, CDVI N’APPLIQUE
AUCUNE GARANTIE, NI DELIBEREE NI TACITE, A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT,
LE TRANSPORT, LEUR COMMERCIALISATION OU LES CONDITIONS D’UTILISATIONS PARTICULIÈRES.
13] NOTES

FR
MANUEL D’INSTALLATION
8cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
15] PROGRAMMATION
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
A4
Programmation
du mode décimal
ou héxadécimal
Tapez :
- 0 = mode
héxadécimal
(A et B non pris en
compte)
- 1 = mode direct (A est
autorisé)
1 bip
LED verte ON
1 bip = OK
LED verte ON
(4 bips = Erreur)
Tapez la durée
de commande en
secondes 02 à 99
secondes.
A0
Programmation
de l’éclairage
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
Tapez 4, 5, 6, 7 ou 8
pour défi nir le nombre
de termes.
A1
Programmation
du nombre
de termes
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
Tapez : 26, 30 ou 44 pour
le nombre de bits du code
Wiegand.
A2
Programmation
du nombre de bits
BBBB
Pour un retour code Maître usine:
- Appuyez successivement sur les touches 1 3 9 7 5
en maintenant l’appui pendant 5 secondes
par touches.
- Un bip est émis et le voyant vert s’éclaire
une seconde pour valider l’opération.
Nombre de termes :
- 7 termes autorisés en 30 et 44 bits uniquement,
- 8 termes autorisés en 44 bits uniquement.
Mode permanent :
Le clavier est éclairé en permanence et le lecteur
de badges est actif.
Valeurs par défaut
- Tempo éclairage : 10 s (En mode standard).
- Nombre de termes : 5.
- Sortie Wiegand 26 bits en mode direct.
- Buzzer actif.
- Mode permanent cla vier + badges.
Correspondance des signaux sonores
- 1 bip court > Mise sous tension et bip touche.
- 1 bip long > Validation d’une saisie
en programmation.
- 2 bips courts > Entrée et sortie
de programmation.
- 4 bips courts > Erreur de saisie.
Termes utilisés
- Les codes utilisateurs doivent être composés
de 4,5,6, 7 ou 8 termes.

FR
SOLARKPW-SOLARKPB
Lecteur double Technologie Proximité/Digicode® - Wiegand
MANUEL D’INSTALLATION
9
cdvi.com
cdvigroup.com
Tapez 2 fois
le code Maître
2 bips sonores
LED rouge ON
2 bips sonores
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
A5
Programmation
du mode Buzzer
Tapez :
- 0 = Sans Bips touches
- 1 = Avec Bips touches
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
A6
Programmation
du code Mâitre
Tapez les 5 termes
du code maître
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 bip
LED verte ON
A7
Programmation
du mode de
fonctionnement
Tapez :
- 0 = Permanent
- 1 = Veille
BBB
B
Mode veille :
En attente, le clavier est faiblement éclairé
et le lecteur de badge est inactif. A l’approche
du lecteur, le système s’active, l’éclairage devient
plus intense (démarrage de la temporisation)
et le lecteur de badge devient opérationnel. Le
lecteur se remet en mode veille à la fi n
de la temporisation.
- En mode direct, seuls la touche B
est interdite pour composer les codes.
Touche B pour valider.
- En mode hexadécimal, seuls les touches
de 0 à 9 sont autorisées pour composer
les codes. Touche B pour valider.
- L’utilisateur doit composer son code
puis appuyer sur la touche B pour valider.

FR
INSTALLATION MANUAL
10 cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
Dual technology: Proximity reader and/
or Digicode® keypad.
Wiegand 26, 30 or 44 bit.
Sensitive touch keypad.
Direct connection.
PCB sealed in epoxy.
Audible and visual feedback.
Versions available: white or black.
Technology: 125 Khz.
Multi card protocol reader - Marin/HD.
Input voltage: 12V dc.
Consumption: 100mA.
1] PRODUCT PRESENTATION
3] MOUNTING KIT
2] REMINDERS AND RECOMMENDATIONS
Foam seal 3x30
TF screw S5
Plastic anchor TORX® bit 3x8
TORX® screw Varistor
GAMME SOLARKP
1 2 2 1 1 1
CE Certifi cation
Certifi cation FCC CFR 47
part 15 compliance
WEEE IP53 -25°C to +70°C
Operating mode
MODE
SYSTEME KEYPAD PROXIMITY DUAL TECHNOLOGY
TELACCESS ✔ ✔ ✔
TERENA ✔ ✔ -
CENTAUR ✔ ✔ ✔
ATRIUM ✔ ✔ -
Cable
- Programming your installation before installing
products on site.
- The distance between a CENTAUR and ATRIUM
controllers or an INTBUSW reader interface
should not exceed more than 50 meters.
- Make sure that the cable is not near by a high
voltage cables (ex: 230 V AC).
- Recommended cable 2 twisted pairs
SYT1 0.8MM (AWG 20).
Back EMF protection
To secure the system from back electromagnetic
fi elds do not forget to mount the varistor in parallel
on the lock terminals.
Security Advice
- For security reasons, change the factory default
master code.
- When selecting a master code and user code
avoid simple codes (example : 3 4 5 6 7).
Mounting recommendations
Mount the keypad on a fl at surface to avoid
any vandalism and to insure the best mounting.
Recommended power supplies
ARD12 & BS60. These products must be powered
in 12Vdc and the power supply should be
certifi ed EN60950-1:2006/A11:2009 standards
and should be designed to be a low power supply
source.

11
cdvi.com
cdvigroup.com
EN
INSTALLATION MANUAL
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
4] MOUNTING
6] WIRING DIRECT CONNECTION TO A CONTROLLER
Controller terminal wirings
Wiegand
Terminal Wiegand format
outputs
CTV900A
ATRIUM
+12VDC Input +12V 12V
-0V R1/0V
R2/0V GND
BBuzzer command
input OUT5
OUT6 BUZ
D0 DATA 0 R1/D0
R2/D0 D0
D1 DATA 1 R1/D1
R2/D1 D1
HCLOCK - -
VGREEN LED OUT1
OUT3 GRN
RRED LED OUT2
OUT4 RED
Place
imperatively
the Foam seal
6] WIRING CONNECTION WITH DOOR CONTROLLER (INTBUSW)
6] FONCTIONNEMENT
When powered up
- Green LED illuminates for 1 second.
- RED LED illuminates for 1 second.
- Blue LED illuminates for 1 second with beep for 1 second
Operating mode
- Buzzer activated with 0V input.
- LEDs activated with 0V input.
Standard Mode
- Badge recognized: the orange LED illuminates and the buzzer
activates for 150 milliseconds.
1
R V B D1D0 H - +
Input LED management
Green LED Red LED Status
OFF OFF Off
OFF ON red
ON OFF green
ON ON blue
SOLARKPW - SOLARKPB INTBUSW
+
12VDC
12
-
0V
V
BBuzzer command input 7
D0 Data 0 1
D1 Data 1 3
HClock 2
VGreen LED 8
RRed LED 9

EN
INSTALLATION MANUAL
12 cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
7] 26-BIT WIEGAND FORMAT
Chronograms 0 logic
\DATA1
\CLOCK
\DATA0
1 logic
50
µS 50
µS
2MS 2MS
Interface
- The output format is 26-bit Wiegand (Signals: DATA1, DATA0 and CLOCK),
- Output signal in open collectors (pull up of 2.2K in +5V) 26-bit hexadecimal output format.
The frame is made of 26-bit and built as follow:
- First parity: 1-bit – even parity for the fi rst 12-bit,
- User Code: 3 half of a byte represent the code entered. Each byte is transferred from bit 7 to bit 0,
- Second parity: 1-bit – odd parity for the last 12-bit.
Bit 1 Bit 2 … bit 25 Bit 26
Even parity on bit 2…bit13 Data (24 bits) Odd parity on bit 14…bit 25
KEYPAD CODE
Example with a 4-Digit keypad code: « 1 3 7 A » Then « B » & « 1 3 7 5 » Then « B »
1 0000 0000 0001 0011 0111 0101 0
Direct
Parity 1 0 0 1 3 7 A Parity 2
Hexadecimal
Parity 1 0 0 0 5 5 F Parity 2
Example with a 5-Digit keypad code: « 7 1 3 7 A » Then « B » & « 7 1 3 7 5 » Then « B »
Direct
Parity 1 0 7 1 3 7 A Parity 2
Hexadecimal
Parity 1 0 1 1 6 C F Parity 2
Example with a 6-Digit keypad code: « 6 7 1 3 7 A » Then « B » & « 6 7 1 3 7 5 » Then « B »
Direct
Parity 1 6 7 1 3 7 A Parity 2
Hexadecimal
Parity 1 0 A 3 E 8 F Parity 2
- Parity 1: «0» if the number of 1 in bit 2 to bit 13 is even, «1» if the number of 1 in bit 2 to bit 13 is odd.
- Parity 2: «0» if the number of 1 in bit 14 to bit 25 is odd, «1» if the number of 1 in bit 14 to bit 25 is even.
BADGE CODE EX: 0F01198AAD
Parity 1 1 9 8 A A D Parity 2

EN
INSTALLATION MANUAL
13
cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
8] 30-BIT WIEGAND FORMAT
Signals output in open collectors with pull up in 30-bit hexadecimal format. The output format from
the proximity reader is 30-bit wiegand (Signal: DATA1, DATA0 and CLOCK) and is structured as follow:
- Parity 1: 1 bit – even parity for the fi rst 14-bit. Code : A code is formed from 7 half byte.
Each byte is transferred from bit 7 to bit 0.
- Parity 2: 1 bit – odd parity for the last 14-bit.
Bit 1 Bit 2 à bit 29 Bit 30
Even Parity from bit 2 to bit 15 Data (28-bit) Odd Parity from bit 16 to bit 29
KEYPAD + BADGE CODES
Example: Badge 0F01198AAD + 6-DIGIT Keypad code: « 6 7 1 3 7 5 » Then « B ».
1 0001 0001 1001 1000 1010 1010 1101 0
BADGE Parity 1 1 1 9 8 A A D Parity 2
KEYPAD
CODE
Direct
Parity 1 0 6 7 1 3 7 5 Parity 2
Hexadecimal
Parity 1 0 0 A 3 E 8 F Parity 2
- Parity 1: «0» if the number of 1 in bit 2 to bit 15 is even, «1» if the number of 1 in bit 2 to bit 15 is odd.
- Parity 2: «0» if the number of 1 in bit 16 to bit 29 is odd, «1» if the number of 1 in bit 16 to bit 29 is even.
9] 44-BIT WIEGAND FORMAT
44-bit hexadecimal format. The output format from the proximity reader is 44-bit (Signal: DATA1, DATA0
and CLOCK) and is structured as follow:
- Data: 10 digit code number hexadecimal MSByte fi rst. Each hexadecimal digit = 4 bit, MSBit fi rst
- LRC : 4 bit = or restricted in between the digit of the data, MSBit fi rst.
Bit 1 to bit 40 Bit 41 to bit 44
Badge code LRC
KEYPAD + BADGE CODES
Example: Badge 0F01198AAD + 8-DIGIT Keypad code: « 6 7 1 3 7 5 » Then « B »
0000 1111 0000 0001 0001 1001 1000 1010 1010 1101 ...
BADGE 0 F 0 1 1 9 8 A A D LRC
KEYPAD
CODE
Direct
0000671375LRC
Hexadécimal
0 0 0 0 0 A 3 E 8 F LRC

EN
INSTALLATION MANUAL
14 cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
10] LED MANAGEMENT ON CENTAUR SYSTEM
11] LED MANAGEMENT ON ATRIUM SYSTEM*
GREEN LED
SETTINGS
RED LED
SETTINGS
LED ACTUATION :
GREEN
ACCESS ALLOWED
RED
ACCESS DENIED
BLUE
STAND-BY
LED ACTUATION
GREEN
ACCESS ALLOWED /
RED
ACCESS DENIED /
BLUE
STAND-BY
* In Digicode® keypad mode only or Proximity mode only.

EN
INSTALLATION MANUAL
15
cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
*Refer to Limited Lifetime Warranty conditions
12] LIMITED LIFETIME WARRANTY [EXTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed
in accordance with the manufacturer’s instructions and has not been modifi ed or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only
if the product is registered, within 1 month from delivery to the fi nal costumer. To obtain full details of this
warranty and to register the product to commence the “Limited Lifetime Warranty”, complete the enclosed
registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the
on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive
remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or
malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product.
The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back
cover of the installation manual.
DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
13] NOTES

EN
16 cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
MANUEL D’INSTALLATION
14] PROGRAMMING CHART
To recover the factory master code:
- Press successively on terms 1 3 9 7 5
by keeping the pressure for 5 secondes
per digit.
- One beep is emitted and the Green LED is lighting
up during 1 second to validate the operation.
Number of digits:
- 7 digits allowed in 30 or 44 bits only,
- 8 digits allowed in 44 bits only.
Permanent Mode:
The keypad is permanently illuminated
and the reader is ON.
Default values
- Illumination duration: 10 seconds
(in standard mode),
- User code lenght: 5 digits,
- 26 bit wiegand output in direct mode,
- Buzzer abled,
- permanent mode keypad + tags.
Audible Signal
- 1 short beep > keypad powered
and key presses,
- 1 long beep > data computing
in programming,
- 2 short beeps > Entry or Exit
from programming,
- 4 short beeps > data computing error.
1 beep = OK
Green LED ON
4 beeps = Error
1 bip
LED verte ON
A4
Programming
Centaur or
Standard format
Enter:
- 0 = for hexadecimal
mode (A & B are not
used)
- 1 = for decimal mode
(Direct mode, A is allowed)
1 beep
Green LED ON
1 beep = OK
Green LED ON
4 beeps = Error
Enter the illumination
time in seconds fron
02 to 99 seconds
A0
Programming
illumination
keypad
1 beep = OK
Green LED ON
4 beeps = Error
1 beep
Green LED ON
Enter:
4, 5, 6, 7 or 8 to specify
the number of digits.
A1
Programming
the code lenght
1 beep = OK
Green LED ON
4 beeps = Error
1 beep
Green LED ON
Enter: 26, 30 or 44
to defi ne the Bit number
of the Wiegand format
A2
Programming the
Bit format
BBBB

EN
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
MANUEL D’INSTALLATION
17
cdvi.com
cdvigroup.com
Enter the master code
2 times
Stand-by mode:
In stand-by mode, the keypas is weakly illuminated
and the reader is OFF. Approaching activate the
system, the keypad illumination becomes more
intense (starting of the time-out) and the reader
reverts in ON. The reader come back on stand-by
mode at the end of the time-out.
Code Length
- The user code must be in 4, 5, 6, 7 or 8 digits,
- In direct mode, all the keypad keys can be
used to program a user code except the B key,
- In hexadecimal mode, all the keypad keys
can be used to program a user code
except the A and B key,
- Enter the user code and then B to validate
the code. 2 beeps are emitted
Red LED ON
2 beeps are emitted
1 beep = OK
Green LED ON
4 beeps = Error
1 beep
Green LED ON
A5
Programming
for decimal or
hexadecimal mode
Enter:
- 0 = disable the
keypad beeps
- 1 = Enable the
keypad beeps
1 beep = OK
Green LED ON
4 beeps = Error
1 beep
Green LED ON
A6
Programming
the audible signal
Enter:
Enter the 5 terms
of the master code
1 bip = OK
LED verte ON
(4 bips = Erreur)
1 beep
Green LED ON
A7
Programmation
du mode de
fonctionnement
Tapez :
- 0 = Permanent
- 1 = Stand-by
BBB
B

EN
18 cdvi.com
cdvigroup.com
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
MANUEL D’INSTALLATION

EN
SOLARKPW-SOLARKPB
Dual Technology Digicode®/Proximity reader - Wiegand
MANUEL D’INSTALLATION
19
cdvi.com
cdvigroup.com

cdvigroup.com
Manufacturing Access Control since 1985
Reference : G0301FR0403V02
Extranet : EXE-CDVI_IM SOLARKPW-SOLARKPB CMYK A5 EN-FR 02
CDVI Group
FRANCE
(Headquarter/Siège social)
Phone: +33 (0)1 48 91 01 02
Fax: +33 (0)1 48 91 21 21
All the information contained within this document (photos, drawing, features, specifi cations and dimensions)
could be perceptibly different and can be changed without prior notice.
Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques
techniques et dimensions) peuvent varier et sont susceptibles de modifi cations sans notifi cation préalable.
G0301FR0403V02
CDVI
FRANCE + EXPORT
Phone: +33 (0)1 48 91 01 02
Fax: +33 (0)1 48 91 21 21
CDVI AMERICAS
[CANADA - USA]
Phone: +1 (450) 682 7945
Fax: +1 (450) 682 9590
CDVI BENELUX
[BELGIUM - NETHERLAND - LUXEMBOURG]
Phone: +32 (0) 56 73 93 00
Fax: +32 (0) 56 73 93 05
CDVI
SUISSE
Phone: +41 (0)21 882 18 41
Fax: +41 (0)21 882 18 42
CDVI
CHINA
Phone: +86 (0)10 62414516
Fax: +86 (0)10 62414519
CDVI IBÉRICA
[SPAIN - PORTUGAL]
Phone: +34 (0)935 390 966
Fax: +34 (0)935 390 970
CDVI
ITALIA
Phone: +39 0321 90573
Fax: +39 0321 908018
CDVI
MAROC
Phone: +212 (0)5 22 48 09 40
Fax: +212 (0)5 22 48 34 69
CDVI SWEDEN
[SWEDEN - DENMARK - NORWAY - FINLAND]
Phone: +46 (0)31 760 19 30
Fax: +46 (0)31 748 09 30
CDVI UK
[UNITED KINGDOM - IRELAND]
Phone: +44 (0)1628 531300
Fax: +44 (0)1628 531003
DIGIT
FRANCE
Phone: +33 (0)1 41 71 06 85
Fax: +33 (0)1 41 71 06 86
Other manuals for SOLARKPW
2
This manual suits for next models
1
Table of contents
Languages:
Other CDVI Lock manuals