INSTALLING FURNACE – 9 TO 15” WALLS (CDV15/CDV25-B).For 9”
to 15” wall use Vent Kit No. VK1525/9-15-B. Do not attempt to lengthen the exhaust tube, air intake tube, or wall thimble
extension provided with furnace or the VK1525/9-15-B Vent Kit. Disconnect the air intake tube, and the exhaust tube from the
back of the furnace and discard. See Figure 6. Replace with exhaust tube and air intake tube from Kit No. VK1525/9-15-B.
Discard the 5” telescoping wall thimble extension that surrounds the wall thimble assembly. Center the wall thimble assembly in
the 9” opening and attach to inside wall using eight (8) screws. Install furnace flush to wall by sliding exhaust tube and air intake
tube through the wall thimble assembly. Secure the furnace to the wall with screws through each of the four holes in the
mounting brackets located on the back of the furnace. These holes are spaced so as to allow the screws to enter into studs that are
on 16-inch centers. On certain types of wall, anchors (not provided) may be required. From outside the building install the thick
wall thimble extension, Part No. 43835, supplied in Vent Kit No. VK1525/9-15-B by sliding it through the cut out and over the
wall thimble assembly. The wall thimble extension should be even with the outside wall (some trimming may be necessary).
Slide the vent terminal onto the exhaust tube and the air intake tube. Secure vent terminal and vent terminal spacer plate to wall
providing a slight downward slope to the vent tubes. This will prevent water from entering. Anchors (not provided) may be
required. Caulk around the vent terminal spacer plate with putty provided. See Figure 7. NOTE: Some framing may be
necessary to provide a flat surface for the vent terminal spacer plate to butt against, so rain cannot enter through cut out.
INSTALLINGFURNACE– 15”TO24”WALLS (CDV15/CDV25-B).For
15” to 24” wall use only Vent Kit No. VK1525/15-24-B. Do not attempt to lengthen the exhaust tube, air intake tube, or wall
thimble extension provided with furnace. The VK1525/15-24-B Vent Kit has a one inch restrictor in the exhaust tube which is
necessary for proper and safe operation of this furnace. Do not use any other vent kit. Disconnect the air intake tube and the
exhaust tube from the back of the furnace and discard, see Figure 6. Install the exhaust tube and air intake tube from Vent Kit No.
VK1525/15-24-B. Discard the 5” telescoping wall thimble extension that surrounds the wall thimble assembly. Center the wall
thimble assembly in the 9” opening and attach to inside wall using eight (8) screws. Install furnace flush to wall by sliding
exhaust tube and air intake tube through the wall thimble assembly. Secure the furnace to the wall with screws through each of
the four holes in the mounting brackets located on the back of the furnace. These holes are spaced so as to allow the screws to
enter into studs that are on 16-inch centers. On certain types of walls, anchors (not provided) may be required. From outside the
building install the wall thimble extension, Part No. 43730, supplied in Vent Kit No. VK1525/15-24-B by sliding it through the
cut out and over the wall thimble extension. For walls 15” to 19” the wall thimble extension, air intake tube, and the exhaust tube
must be trimmed even with the outside wall. Slide the vent terminal onto the exhaust tube and into the air intake tube. Secure
vent terminal and vent terminal spacer plate to wall providing a slight downward slope to the vent tubes. This will prevent water
from entering. Anchors (not provided) may be required. Caulk around the vent terminal spacer plate with putty provided, see
Figure 7. NOTE: Some framing may be necessary to provide a flat surface for the vent terminal spacer plate to butt against, so
rain cannot enter through the cut out.
Page 6
INSTALLING FURNACE – 9 TO 15” WALLS (CDV33-B).For 9” to 15” wall use Vent
Kit No. VK33/9-15-B. Do not attempt to lengthen the exhaust tube, air intake tube, or wall thimble extension provided with
furnace or the VK33/9-15-B Vent Kit. Disconnect the air intake tube, and the exhaust tube from the back of the furnace and
discard. See Figure 6. Replace with exhaust tube and air intake tube from Kit No. VK33/9-15-B. Discard the 5” telescoping wall
thimble extension that surrounds the wall thimble assembly. Center the wall thimble assembly in the 9” opening and attach to
inside wall using eight (8) screws. Install furnace flush to wall by sliding exhaust tube and air intake tube through the wall
thimble assembly. Secure the furnace to the wall with screws through each of the four holes in the mounting brackets located on
the back of the furnace. These holes are spaced so as to allow the screws to enter into studs that are on 16-inch centers. On
certain types of wall, anchors (not provided) may be required. From outside the building install the thick wall thimble extension,
Part No. 43835, supplied in Vent Kit No. VK33/9-15-B by sliding it through the cut out and over the wall thimble assembly. The
wall thimble extension should be even with the outside wall (some trimming may be necessary). Slide the vent terminal onto the
exhaust tube and the air intake tube. Secure vent terminal and vent terminal spacer plate to wall providing a slight downward
slope to the vent tubes. This will prevent water from entering. Anchors (not provided) may be required. Caulk around the vent
terminal spacer plate with putty provided. See Figure 7. NOTE: Some framing may be necessary to provide a flat surface for the
vent terminal spacer plate to butt against, so rain cannot enter through cut out.