3.1. TRANSPORTATION AND STORAGE
TRANSPORT / STORAGE
To avoid PV mod le damage:
•Store PV mod le in dry premises. The package is not atmosphere infl ence resistible!
•Transport the mod le in its original package ntil its instalation.
•Use vac m c pping glass for mod les' movement and transportation or hold the mod le by
the edges. Carry the mod le in vertical position when transporting over long distances.
•Do not pick and do not move the mod le while sing the cables or the j nction box area in
nder any circ mstances!
•Do not pile- p mod les one over another!
•Do not let the mod le to recline on its edges, witho t protecting it.
4. INSTALATION POSITIONING
•The mod le is tested for safety operation in temperate climate.
•Allowed temperat res for the mod le are between -40ОC and +85ОC. Check if there is
adeq ate ventilation nder the mod le, so the maximal temperat re exceeding to be avoided.
•Observe the req irements for f nctional gro nding in dependence of mod les positioning (see
chapter 5.4 “Gro nding”).
•Do not expose the mod le to the chemicals impact
•Do not deep the mod le in water. Th j nction box is resistible only to water drops.
•Do not position the mod le neear to flamable gases or vapo rs (eg. gas containers) or near to
open fire or flamable materials.
AVOIDING THE SHADING
The optimal solar radiation leads to maximal electric prod ction. This for, position the mod le in a way
that the photovoltaic cells to be oriented toward the s n.
Avoid mod le shading, as this will ca se negative effect to its performance. It is believed that a mod le
is f lly witho t shading, when there is no shadow over it tho gh the year (eg. shadow from: b ildings,
chimneys, trees). Even partial mod les shading (eg. overhead cables, pol tion, snow) m st be avoided
(see also chapter 7 “Cleaning and maintenance”).
Also caref ly revise the mod les' orienatation specification and the inclination degree (see chapter 5.1
“Mechanical assemblying”).
5. ASSEMBLY AND INSTALATION
SAFETY INSTRUCTIONS
WARNING! Damaged modules' components can create risk of fire!
•Instal only reliable photovoltaic mod le.
•Before the instalation, make s re that j nction box, cable and connectors are not damaged.
•Do not open j nction box in any circ mstances.
•Allways keep the photovoltaic mod le in dry premises. The package is not climate infl ence
resistible!
•The mod les' voltage is higher with lower temperat res and/or when there is higher radiation
than the Standard Test Conditions (25OC cells temperat re, 1000W/m2, AM 1,5). This m st be
taken into acco nt when yo connect several mod les, so that the total voltage of the mod les
strings m st not exceed 1000 VDC (in agreement with IEC 61215, Edition 1/61730, Edition 2) or
600 VDC (in agreement with UL1703).
•Please comply with the req irements for f nctional gro nding in dependence of mod les'
positioning (see Chapter 5.4, “Gro nding”)
5