DanVex DEH-1200P User manual

DanVex DEH-1200Р
DEHUMIDIFIER
INSTALLATION AND OPERATING
INSTRUCTIONS

R
www.danvex.fi
1
RoHS
Please read this instruction manual before using the dehumidifier.

R
www.danvex.fi 2
CONTENTS
Safety Instruction .............................................................................................
Attention during Usage .................................................................................
Principle of dehumidifier .................................................................................
Specification ....................................................................................................................
Exploded Views ...............................................................................................................
Descriptions of Parts ........................................................................................
Installation note ................................................................................................................
Function of the needle valve .............................................................................................
Panel Control ...................................................................................................
Remote Controller .....................................................................................
Operation Guide .............................................................................................
AUTO Operation Mode .................................................................................
Air Direction Adjustment ...............................................................................
Timer Operations ............................................................................................
Defrost system ................................................................................................
Water drainage system ...................................................................................
Error codes .....................................................................................................
Wiring diagram ...............................................................................................
Maintenance ..............................................................................................
Trouble Shooting ..............................................................................................................
3
4-5
6
6
7
8
8
8
9
10-11
12
13
14
15
16
16
16
17
7-18
19

R
www.danvex.fi
3
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according
to the seriousness of possible risks and damages as follows. Compliance to the instructions
are strictly required for safety use.
Installation
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock,
fire, water leakage.
WARNING
!
WARNING
!
Installation in a inadequate place may cause accidents. Do not install in the following place.
PROHIBITION
Do not install in the place where
there is any possibility of
inflammable gas leakage around
the unit.
PROHIBITION
Do not get the unit exposed to
vapor or oil steam.
Connect the earth cable.
WARNING
!
When abnormality such as burnt-small found,
immediately stop the operation button and contact
sales shop.
Use an exclusive power source with a circuit
breaker.
OFF
!
STRICT
ENFORCEMENT

R
www.danvex.fi 4
WARNING
!
Attention during Usage
Ensure the power plug is secure
If the plug is not secure, it may
cause a electric shock,
overheating or a fire.
Never pull out the power plug
during operation.
otherwise, it may cause a electric
shock or a fire due to overheating.
Never use damaged electric
wires or unspecified electric
wires.
otherwise it may cause a electric
shock or a fire.
Do not use the same socket
with other electric appliances or
use an extension cord.
otherwise it may cause a electric
shock or a fire due to overheating.
Do not operate when the hands
are wet.
due to danger of a electric shock.
Do not insert a rod or other
objects into the inlet or outlet
vents.
otherwise, it may cause a electric
shock or a fire.
Do not expose yourself to a
single directional airflow for a
long period to avoid harming to
your health.
In case of abnormal condition
(burning smell etc.),pull out the
power plug to stop the
dehumidifier from running, or
disconnect the power supply by
means of a electric current
protector.
If the abnormal condition persists,
it may cause a electric shock or a
fire due to overheating. Please
consult the dealer of service
centre as soon as possible to
arrange for a repair.
Do not attempt to carry out a
repair.
Improper repairs may cause a
electric shock or a fire. You should
contact the dealer of service
centre to arrange for a repair.

R
www.danvex.fi
5
WARNING
!
Attention during Usage
Do not hold the electric wire to
pull out the power plug.
Pulling of the electric wire may
cause overheating of the electric
wire of a fire.
If the dehumidifier is not in use
for a long time, it is necessary
to pull out the power plug.
Excessive dust on the power plug
may also cause overheating or a
fire
Switch off the power supply
while cleaning the dehumidifier.
Please take care not to damage
the internal fan which is rotating at
a high speed.
Do not use the dehumidifier for
other purposes.
Do not use it for keeping precision
instruments, food, plants and
artistic items. This may affect the
quality of the food.
Do not place a heater in front of
the dehumidifier.
If internal combustion of the heater
is not complete, it may give out
poisonous carbon monoxide.
Do not pour water onto the
dehumidifier for cleaning.
Due to danger of electric shocks.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION

R
www.danvex.fi 6
Principle of dehumidifier
WATER PUMP
CAPILLARY
CONDENSE WATER
FAN
COMPRESSOR
AMBIENT
AIR
INLET
WATER
DRAIN
OUT
WARM
DRY
AIR
OUTLET
CONDENSER EVAPORATOR
The dehumidifier use the refrigeration circuit to change the damp air warm dry air.
When the damp air passes the condenser, the air water will be condensed and the air will become dry.
Model
Capacity(L/hr)
Heating capacity(W)
Power consumption(W)
Air flow(m3/hr)
Refrigerant(g)
Power supply
Current(A)
Compressor type
Compressor(brand name)
Water pump
Applicable area( )
Noise(dB(A))
Drain pipe(mm)
Unit dimension(mm)(WxHxD)
Packing dimension(mm)(WxHxD)
Weight(net/gross)(kg)
DEH-1200P
4.5
2300
1300
850
850
220-240V/50Hz/1 Ph
5.8
Rotary
Toshiba
No
100-150
48
500
530x1735x350
5635x1930x455
49/66
The Specification Of Dehumidifier (R410a)
Test condition: Dry ball temperature 30. Relative humidity of 80RH%.

R
www.danvex.fi
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Front Panel 1
Front Panel 2
Control panel
Back board
Left panel
Top cover
Condenser
Upper fixing board
Plastic cover
Right panel
Cross flow fan
Cover
Fan motor
Heat exchanger bracket
Plastic foam air duct
Evaporator
Water pan
Water fender
Plastic-base
Chassis
Compressor
Four Way Valve
Indoor temperature sensor
Drain pipe
Electrical box cover
Terminal
Compressor Capacitor
Public Terminal
Motor Capacitor
Circuit Board
Transformer
Electrical box
Stepper motor
Synchronous motor
Filling gas valve
Humidity sensor
Draining connector
Power Cord
PG connector
Defrost temperature sensor
Capillary
Filter

R
www.danvex.fi 8
Descriptions of Parts
0,1 Air Outlet
0,2 Control Panel
0,3 Air filter(inside)
0,4 Air Inlet
0,5 Drain pipe outlet
0,6 Chassis drain outlet
Installation note
To ensure dehumidifier is steady during running,
it prepared top dead plate, the installation and use
as following.
Function of the needle valve
When the heat pump need to measure the pressure
of the current system or to filling refrigerant, the
operator can use this service valve and make the
appropriate maintenance work!

R
www.danvex.fi
9
Control Panel
Button
Press the button to start operation, press
the button again to stop operation.
Select the fan speed. Fan speed is
selected in a sequence: LOW , MID ,
HIGH.
Set the swing or stop of Left-Right Airflow
louver
Press the "L-R Swing" and "U-D Swing"
together to enter timer setting.
Mode is selected in a sequence:
Automatic ; Dehumidifying ; Fan ;
Heating.
One press of the “ + “ button to raise the
temperature by 1 One press of the “ - ”
button to lower the temperature by 1 .
Set the swing or stop of Up-Down Airflow
louver.
DISPLAY
BUTTON
Display
Auto operation mode
Fan operation mode
Displays when
Displays when
Displays when
Heating operation mode
Dehumidifying operation mode CLOCK or TEMPERATURE or display
turns to CLOCK status
turns to TEMPERATURE status
turns to status

R
www.danvex.fi 10
Remote Controller
Signal Emitter :
Sending out remote
control signal to the
dehumidifier.
Remote Controller
Display Panel :
Display settings.
Mode Button :
Select Automatic,
Heating, Dehumidifying,
Fan modes.
FAN Button :
Air flow setting.
Timer Cancel Button
:
Cancel Timer-On and
Timer-Off settings.
Air Direction Button :
Set air louver swinging or
stationary.
On/Off Button :
Press once to start
dehumidifier running;
Press again to stop
running.
Timer Off Button :
Set Timer-off hour.
Timer On Button :
Set Timer-on hour.
Timer Confirm Button
:
Send Timer-on or
Timer-off data to the
dehumidifier.
Temperature
Adjustment Button :
Adjust temperature
settings
Press once to set
temperature 1 degree
higher.
Press once to set
temperature 1 degree
lower.

R
www.danvex.fi
11
Remote Controller
Emission Indicator :
This symbol flashes once when
the remote controller emits
signals to the dehumidifier.
Temperature Display :
It displays the current set
temperature which may be
adj ust ed b y Tempe rat ure
Adjustment Button or within
the range of 18 ~31℃.
Mode Display :
Press "Mode" button to
display the current working
mode. Automatic, Heating,
Dehumidifying, Fan modes
Timer Display :
It displays the time setting for
Timer-On or Timer-Off in the
range of 1~12 hours.
Air Direction Display :
When “Swing" is in display,
the up-down louver of the
dehumidifier is swinging. When
the display disappears, the up-
down louver stops swinging.
Fan Display:
It display the current
amount of air flow.
FAN Display on
Remote
Controller
Automatic
Low
Mid
High
FAN
FAN
FAN
AUTO FAN
NOTE:
All Displays on the diagram are listed out for demonstration. During operation, only the relevant display will
appear on the remote controller.

R
www.danvex.fi 12
Operation Guide
Proper settings of Heating, Dehumidifying and Fan modes
Mode Selection ( 1 )
Press "Mode" button to select the required working mode,
Which is changed in the following sequence when press once:
Automatic Dehumidifying Fan Heating
NOTE:
Automatic operation will be explained in detail on next page.
Air Flow Selection ( 2 )
Press "FAN" button to select the required fan speed, Which
is changed in the following sequence when press once:
Automatic Low Mid High
NOTE:
When automatic FAN is selected, the dehumidifier will
automatically select the suitable amount of air flow according to
room temperature.
When dehumidifying is selected, the amount of air flow is set
by the machine and fan setting is not functional.
Temperature Setting Selection ( 3 )
Press "Temperature Adjustment Button " to set temperature 1 degree higher.
Press "Temperature Adjustment Button " to set temperature 1 degree lower.
Hold down the Button to increase of decrease the temperature settings progressively.
NOTE:
Range of adjustable temperature settings : 18 C ~ 31℃.
Starting Operation ( 4 )
Press "On/Off" button, and when the unit receives the signal, it gives out two "beep" tones,
the operation light is on and the dehumidifier starts operation.
NOTE:
If it is desired to run the machine at the same settings for mode, air flow and temperature as the last operation
skip Steps 1~3 and start the machine directly. If the interval is shorter than 3 minutes from last shut down to
the present switch-on, the compressor only re-starts after 3 minutes to protect the system. After switching on
and if the mode is changed, the system may delay for 3 minutes before starting operation.
When heating mode is selected, the internal fan will delay operation for a while when the machine is switched
on to prevent cool air circulation at the beginning. After switching on, air flow amount and temperature may be
separately adjusted as desired.

R
www.danvex.fi
13
NOTE:
When Automatic FAN is selected, the unit will automatically
select the suitable amount of air flow according to room temperature.
Press "FAN" button to select the required amount of air flow,
which is changed in the following sequence when pressed once:
Automatic Low Mid High
AUTO Operation Mode
Mode Selection (1)
Press "Mode" button to select Automatic Operation mode.
To set the temperature (heating) by button '+' and '- ', 5 seconds
Later will be confirm; then to set the dehumidify by button '+'
and '- ', 5 seconds later will be confirm.
Fan Selection (2)
Starting Operation (3)
Press " On/Off " button, and when the unit receives the signal, it
gives out two " beep " tones, the operation light is on and the
dehumidifier starts operation is automatic mode.
NOTE:
In automatic mode, user can select the room temperature and humidity separately:
Heating
Dehumidify
18~31 adjustable
1%~99% adjustable
Factory setting is 25
Factory setting is 60%
Adjustment in Automatic Mode
Feeling Button
Unsuitable fan speed FAN
Operation
Press once to change the air flow progressively until the
suitable air flow is selected.

R
www.danvex.fi 14
Air Direction Adjustment
Up-Down Air Direction Adjustment
Airflow horizontally Airflow downward Airflow upward
NOTE:
To stop the up-down air louver in a desired position, set the louver to automatic swinging and when it reaches
the desired position, stop the louver from swinging. It is necessary to adjust the louver angle by means of the
remote controller, Setting of the louver with the hand may affect its normal operation, in which event, switch
off the unit temporarily and re-start operation.
To get the best effect, the up-down air flow is usually set in the following manner : Dehumidifying - Horizontal
air direction or upward air direction. Heating -Downward air direction
Changing Left-Right Air Direction
NOTE: Don’t move the Left-Right van directly.
or

R
www.danvex.fi
Timer Operations
Timer Switch On
1. Press "Timer On" button to set time for timer-on switching.
Press the button once to change the time interval of 1 hour in
a cyclic manner of 6, 7, 8 ...12 ..1, 2..5, 6 (The display is
showing the previous time as the starting time of the present
setting). If the button is held down, the time interval will
increase progressively by 1 hour unit.
2. Point the remote controller towards the receiver on the unit,
Press "Timer Confirm" button to send the timer setting to the
dehumidifier. Then the timer light on the unit lights up,
indicating that the unit is in the timer mode. When it reaches
the switch-on time, the dehumidifier will operate in the pre-set
modes.
NOTE:
Before timer operation, please set the operation mode,
temperature, air flow etc. on the remote controller, With timer being
set to switch-on mode. the Dehumidifier will operate according to
the last setting.
Usually, timer-on setting is made while the dehumidifier is not
in operation. If timer-on is set while the dehumidifier is running,
then the unit will shut down immediately and re-start at the pre-set
time.
If the "On-Off" button is pressed while the unit is under timer-on
setting, then the unit will start immediately, the timer setting is cancelled and the timer light will be off.
Timer Switch Off
1. Press "Timer Off" button to set time for timer-off switching. Press the button once to change the time interval
of 1 hour in a cyclic manner of 6, 7, 8 ...12 ..1, 2..5, 6 (The display is showing the
previous time as the starting time of the present setting). If the button is held down, the time interval will
increase progressively by 1 hour unit.
2. Press "Timer Confirm" button to send the timer setting to the Dehumidifier. Then the timer light on the unit
lights up, indicating that the unit is in the timer mode. When it reaches the switch-off time, the air-conditioner
will automatically shut down.
NOTE:
Timer-Off can only be set when the Dehumidifier is running.
Timer-On and Timer-Off cannot be set at the same time.
Timer display on the remote controller : While time passes, the display shows the remaining time.
If the "On-Off" button is pressed while the unit is under timer-off setting, then the unit will shut down
immediately, the timer setting is cancelled and the timer light will be off.
Timer Cancellation
Press "Timer-Cancel" button to cancel the timer-on or timer-off settings.
15

R
www.danvex.fi 16
Defrost system
Sequences of the defrosting:
1. Start
The defrosting is engaged if the following conditions are at the same time fulfilled:
- the compressor and the fan motor run without stopping;
- the defrosting sensor temperature lower than 3 , and the duration of time more than 45 minutes;
- the defrosting sensor temperature goes down to -7 .
2. After 15 seconds, the 4 way valve shifts.
3. Five seconds after its stop, the compressor starts alone ; And the accumulated freeze on the gills becomes
melting, what is generally with a steam cloud .
4. Stop:
The defrosting stops if one of the following conditions is fulfilled:
- the defrosting operates 20 seconds and the detected temperature by the defrost sensor goes up to 12 ;
- the compressor had run totally 8 minutes.
5. The compressor runs.
6. After 15 seconds the 4 way valve shifts
7. Five seconds after its stop the compressor and the fan start for restarting in heating mode.
8. The running light is blinking during defrosting.
Water drainage system
During the dehumidify mode, the condenser water will be drained into the internal water tank .When the water
reaches the certain level, the water drain pump will work. If the water can be drained out in 8 minutes, the
dehumidifier will keep working. If not, the compressor and the motor will stop working. Mean while an error
message “ E4 “ will appear in the control panel to inform you to empty the water.
In this instance, you should cut the power off, and then restart the dehumidifier ,and the operation
will continue .
Error Codes
E1 : Room temperature sensor error;
E2 : Defrost temperature sensor error;
E3 : Humidity sensor error;
E4 : Drain error;
P1 : Electrical heater error;

R
www.danvex.fi
17
Wiring diagram
Maintenance
For smart use of the Dehumidifier:
Setting of proper room
temperature.
Do not block the air inlet or outlet. Use the timer effectively.
Close doors and windows during
operation.
If the unit is not to be used for
a long time, turn off the power
supply main switch.
Use the louvers effectively.

R
www.danvex.fi 18
WARNING
!
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller Body
Do not use water, wipe the
controller with a dry cloth.
Do not use glass cleaner or
chemical cloth.
Wipe the air conditioner by
using a soft and dry cloth.
For serious stains, use a neutral
detergent diluted with water.
Wring the water out of the cloth
before wiping. then wipe off the
detergent completely.
Do not use the following for cleaning
Gasoline, benzine, thinner or cleanser Hot water over 40 (104 )
may damage the coating of the unit. may cause discoloring or deformation.
Air Filter cleaning
Press the clasp on the top of the grill and pull the grill out, and then
the filter will be taken out along a gradient way.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.
After washing, dry the filter completely in the shade. Then, reinstall
it onto the unit.
To keep your Dehumidifier in good condition after season:
1. Operate in FAN mode for about half a day.
On a fine day, unit shall be started and operate in FAN
mode for about half a day until the inside of the unit
becomes thoroughly dry.
2. Turn off the power supply main switch.
3. Cleaning the body. 4. Take out the batteries from the wireless remote
controller.

R
www.danvex.fi
19
Trouble shooting
Before asking for service, check the following first.
The system does not
restart immediately.
l When unit is stopped, it won' t restart immediately until 3
minutes have elapsed to protect the system.
When the electric plug is pulled out and reinserted, the
protection circuit will work for 3 minutes to protect the
dehumidifier.
Noise is heard:During unit operation or at stop, a swishing or gurgling
noise may be heard. At first 2-3 minutes after unit start,
this noise is more noticeable. (This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.
This noise is generated by the casing expanding or
shrinking because of temperature changes.
Should there be a big noise from air flow in unit operation,
air filter may be too dirty.
Smells are generated.This is because the system circulates smells from the
interior air such as the smell of furniture, cigarettes.
Does not work at all.
Is power plug inserted?
Is there a power failure?
Is fuse blown out?
Normal
Performance
inspection
Multiple
check
Inefficient
Is the air filter dirty? Normally it should be cleaned every
15 days.
Are there any obstacles before inlet and outlet?
Is temperature set correctly?
Are there some doors or windows left open?
Phenomenon Cause or check points
Table of contents
Other DanVex Dehumidifier manuals

DanVex
DanVex AD-550 User manual

DanVex
DanVex DEH-500i User manual

DanVex
DanVex DEH-1600i User manual

DanVex
DanVex DEH-1700wp User manual

DanVex
DanVex DEH-1700P User manual

DanVex
DanVex DEH-400P User manual

DanVex
DanVex AD-200 User manual

DanVex
DanVex AD-200 User manual

DanVex
DanVex AD-400 User manual

DanVex
DanVex AD-3000 User manual