DanVex DEH-400P User manual

DEH-400P/1000P
Air dehumidifiers
Operation manual

R
www.danvex.fi

R
www.danvex.fi
CONTENT
Air dehumidification...................................................................................................................3
Precautions................................................................................................................................4
Dehumidifier description............................................................................................................5
Location and functions...............................................................................................................6
Design........................................................................................................................................7
Control panel.............................................................................................................................8
Water tank and continuous drainage.........................................................................................9
Specifications...........................................................................................................................10
Support and warranty...............................................................................................................11
2

R
www.danvex.fi
AIR DEHUMIDIFICATION
The processes that take place during dehumidification are based on physical laws. We will try
to illustrate them here in a simplified form to give you a general idea of dehumidification
principles.
USE OF DANVEX AIR DEHUMIDIFIER
Despite of windows and doors insulation quality, damp and moisture can penetrate even
through thick concrete walls. It can take 1-2 months for the water used for construction
(concrete works, whitewashing, plasterworks etc.) to dry out.
The moisture that has penetrated masonry following high water or flooding is released very
slowly. One example of moisture-related issues is damping of materials in storage. The
moisture escaping from building elements or materials by evaporation is absorbed by the
ambient air. Thus, this increases the air humidity and ultimately results in corrosion, mould,
rot, peeling of paint coatings and other unwanted damages.
3

R
www.danvex.fi 4
SAFETY PRECAUTIONS
1. Read these operations instructions carefully before operating the dehumidifier.
2. Never immerse the unit into water or other liquids.
3. Never use the unit of its cable or power plug is damaged.
4. Electrical devices can be repaired by qualified personnel only, improper repair can be a
source of serious danger for users.
5. Children are not aware of the unit hazard. Never let children operate electric devices if
they are not under proper control.
6. It is required to disconnect the unit from the power supply when it is out-of-operation
and before its cleaning.
7. The unit should be used only with the voltage specified in the table.
8. Please note that this unit is designed for domestic use only. It is intended for household
needs.
9. It is not allowed to put heavy objects on the dehumidifier.
10. Before transportation make sure that the condensate tank is empty to prevent water
leakage.
11. The unit is not intended for use by physically or psychically limited persons (including
children) or by those who have no experience of were not instructed by the persons
responsible for their safety. Children should be under supervision to assure they do not
play with the unit.
12. If the power cord is damaged it should be replaced by the manufacturer, service center
or similar qualified specialists to avoid danger.
13. It is prohibited to use the unit in the locations where chemical substances are used.
14.Before cleaning the unit should be switched off.

R
www.danvex.fi
DEHUMIDIFIER DESCRIPTION
The unit is designed for automated, versatile and trouble-free air dehumidification. Due to its
compact dimensions it is easy to transport and operate.
The unit operates on condensation principle. It is equipped with a closed loop cooling system,
low noise and low maintenance fan and with a power cable with a plug. The unit's control
panel is equipped with indicators used for the system functional checks. A fully automated unit
control system, a trouble-free regulated humidistat, an integrated overflow system as well as
flexible hose connection for direct condensation discharge assure fail safe and long-term
operation of the unit. The unit complies with the fundamental safety and health requirements
of the existing EU regulations. The unit is easy and safe to operate.
5

R
www.danvex.fi 6
UNIT LOCATION
The unit is operated in the buildings where dry air is necessary to prevent significant financial
losses (for example, due to mould formation).
The unit is mainly used for drying and dehumidification in such locations as:
· Common rooms, bedrooms, bathrooms and basins.
· Kitchens, sommer houses, cellar rooms.
It is also used for dry air maintenance in:
· Storage areas, archives, laboratories.
· Bathrooms, laundries, changing rooms etc.
FUNCTIONS
The unit operates on condensation principle.
The fan intakes moist surrounding air into the units rear side through the air filter, evaporator
and condenser located behind the evaporator. The heat is extracted at the cold evaporator.
The air is cooled to below the dew point. The water vapor contained in the room air deposits
as condensate or frost on the evaporator fins.

R
www.danvex.fi
(1) Control panel
(2) Air outlet
(3) Handles
(4) Front panel
7
(5) Air intake (filter)
(6) Drain hole
(7) Condensate tank
DESIGN

R
www.danvex.fi 8
Numbers for required humidity level setting on the humidity regulator
The unit starting up:
1. Turn the humidity regulator to OFF position.
2. Connect the unit to the mains power supply.
3. Set (turn) the humidity regulator to the
desired humidity value (60% - position 4).
9
8
7
6
5
4
3
2
1
10%
20%
30%
40%
50%
60%
70%
80%
90%
Regulator
position
number
Humidity
Switching off the unit
1. Turn the humidity regulator to OFF position.
2. If the dehumidifier is not used for a long period
of time the power plug should be disconnected
from the mains socket.

R
www.danvex.fi
9
Water tank and continuous drainage
The condensate can be collected in a water tank or drained through a PVC hose.
Water tank for condensate
1. When the tank is full the indicator "TANK FULL" lights up.
Compressor and fan stop.
2. Pull the water tank and remove it. Drain the water
and place the tank back.
Continuous drainage
If you want to use this function please pull the water tank
and connect a hose (option) to the drain connection.
Filter cleaning
1. Remove the rear cover-filter.
2. It is required to remove the filter every two weeks
and wash it with warm water, below 40 °C

R
www.danvex.fi 10
Model
Characteristics
Power supply
Consumed power
Operating current
NET weight
Moisture removal at - (30°С / 80%)
Air consumption
Dimensions (HхDхW)
Temperature range
Water tank
DEH-400p DEH-1000p
230V~50HZ
700W 1350W
3.2 A 5.3A
19.5 kg 24.5 kg
40 l/day 80 l/day
420m3/hour 450m3/hour
630 mm х 480 mm х 300 mm
5°С~32°С
7 liters
SPECIFICATION
(СЕ) N 842/2006: R410A is a kind of fluorinated greenhouse gases covered
by the Kyoto Protocol. Its total global warming potential (GWP) is 1975.
This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent
possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To return your used
device, please use the return and collection systems or contact
the retailer where the product was purchased. They can take this
product for environmental safe recycling.

Warranty obligations
DanVex warrants that all the equipment parts will answer the technical requirements for 24
months from the date of delivery (warranty period).
The warranty does not cover wearable parts such as filters. The warranty covers the defects in
workmanship and materials.
During the warranty period DanVex repairs and replaces the part having a defect of material or an
manufacturing error.
DanVex completely fulfills its warranty obligations when it supplies the Customer a repaired or a
spare part.
Parts repair or replacement does not result in the warranty period extension.
The parts and components replaced under the warranty belong to DanVex.
DanVex or its distributor upon DanVex request has a right to inspect the defective parts and to
check the correctness of the warranty claim.
Warranty repair execution conditions:
The damage occurred during the equipment normal operation. All recommendations and
instructions of the manufacturer concerning the equipment installation, operation and
maintenance were observed. Only original parts and materials were used for the equipment
maintenance and repair.
---------------------------------------------------------------------------------------------------------------------------
THE MANUFACTURER DOES NOT PROVIDE WARRANTY FOR THE COMPATIBILITY OF
THE PURCHASED EQUIPMENT WITH THE BUYER EQUIPMENT. THE SELLER
WARRANTIES THE OPERATIONAL PERFORMANCE OF EACH PART INDIVIDUALLY BUT IS
NOT RESPONSIBLE FOR THE QUALITY OF THEIR COMMON OPERATION EXCEPT FOR
THE CASES WHEN THE EQUIPMENT IS PURCHASED IN ASSEMBLY AND INSTALLED
ACCORDING THE DISTRIBUTOR RECOMMENDATIONS. UNDER THE CONSUMER RIGHT
PROTECTION LAW AS AMENDED AND THE DECREE OF THE GOVERNMENT OF THE
RUSSIAN FEDERATION NO.55 AS OF 19 JANUARY 1998 “LIST OF NON-FOOD PRODUCTS
OF PROPER QUALITY NOT SUBJECT TO THE RETURN OR EXCHANGE FOR THE SIMILAR
GOODS OF THE OTHER SIZE, SHAPE, DIMENSIONS, TYPE, COLOR OR COMPONENT
PARTS” (WITH THE CHANGES FOR 20 OCTOBER, 1998) THE SELLER IS NOT OBLIGED TO
TAKE BACK THE OPERATIVE EQUIPMENT IF IT DOESN'T SUIT THE BUYER FOR SOME
REASON.
R
www.danvex.fi
11

This manual suits for next models
1
Table of contents
Other DanVex Dehumidifier manuals

DanVex
DanVex AD-10000 User manual

DanVex
DanVex DEH-1600i User manual

DanVex
DanVex DEH-600wp User manual

DanVex
DanVex DD Series User manual

DanVex
DanVex DEH-1700P User manual

DanVex
DanVex DEH-600P User manual

DanVex
DanVex DEH-900i User manual

DanVex
DanVex AD-200 User manual

DanVex
DanVex DEH-290h User manual

DanVex
DanVex DEH-1200P User manual