•Normal: When users enable an alarm scene on
the On/Off page, Normal type alarm zone will
be activated after activation time.
o100 seconds is the default activation time, it
means the alarm will be activated after 100
seconds.
oAfter 100s, once sensor is triggered, Indoor
Monitor will send this alarm to Master
Station.
oBut sometimes users don't want to send the
alarm to Master Station (maybe alarm by
mistake), users can set the Delay time, so
they can cancel the alarm in the Indoor
Monitor during this Delay time (PIR, Door,
Window);
•Emergency: once Panic button is triggered,
Indoor Monitor will not initiate an alarm and
only Master Station will receive alarms
secretly; 24 hours standby even if the security
is off (Panic, Pull Cord);
24 Hour: Indoor Monitor will initiate an alarm and
Master Station will also receive alarms. 24 hours
standby even if the security is off (Smoke, Gas,
•3C: for the sensor with 2.2KΩ resistance;
Regardless of the connection to NC or NO, the
alarm can be triggered normally;
•NO: normally open;
•NC: normally closed;
BELL: in BELL mode, Master Station will not
receive any alarm. Indoor Monitor is regarded as
Once sensor is triggered, Indoor Monitor will
send this alarm to Master Station, but users can
terminate the alarm sending to Master Station