Dnake 902D-B9 User manual

User Manual
———
DNAKE 902D-B9


REMARK
Please follow the user manual for correct installation and testing. If there is any
doubt please call our tech-supporting and customer center.
Our company applies ourselves to reformation and innovation of our products. No
extra notice for any change. The illustration shown here is only for reference. If
there is any difference, please take the actual product as the standard.
The product and batteries must be handled separately from household waste.
When the product reaches the end of service life and needs to be discarded,
please contact the local administrative department and put it in the designated
collection points in order to avoid the damage to the environment and human
health caused by any disposal. We encourage recycling and reusing the material
resources.

CATALOG
PRODUCT FEATURE ............................................. 1
TECHNICAL PARAMETER ..................................... 1
PACKAGE CONTENT ............................................. 2
OVERVIEW.............................................................. 3
BASIC OPERATION ................................................ 5
DEVICE SETTING ................................................... 7
WEB SETTING ...................................................... 11
SYSTEM DIAGRAM .............................................. 25
DEVICE WIRING ................................................... 26
INSTALLATION...................................................... 29
TROUBLESHOOTING........................................... 30
SAFETY INSTRUCTION ....................................... 31

1
PRODUCT FEATURE
1. Powered by PoE or power adapter (DC12V/2A)
2. Open the door by face recognition (10,000 users)
3. Liveness detection
4. Open the door by IC card (100,000 users)
5. Support SIP 2.0 protocol, easy integration with other SIP devices
6. Easy integration with elevator control system
7. 2MP camera with WDR mode
TECHNICAL PARAMETER
Power Supply: PoE (802.3af) or DC 12V/2A
Standby Power: 3 W
Rated Power: 10 W
Video Resolution: up to 1920 x 1080
Working Temperature: -10℃to +55℃(default); -40℃to +55℃(with heating film)
Storage Temperature: -40℃to +70℃
Working Humidity: 10% to 90% (non-condensing)

2
PACKAGE CONTENT
MODEL: 902D-B9 (Flush Mounting)
902D-B9
Screw Fixing Seat
(4 pcs)
PA4×25 (4 pcs) PA3×8 (2 pcs) Seal Ring
Rear Cover
Wrench Screw
Wires Quick Start Guide

3
OVERVIEW

4

5
BASIC OPERATION
1. Call and Monitor
1.1. Call Indoor Monitor
In standby mode, press room numbers + #/dial on Door Station to call Indoor
Monitor. During the call, press * on Door Station again to end the call. If the call
fails or Indoor Monitor is busy, Door Station will make a beep sound.
1.2. Monitor Door Station
Click Monitor icon on Indoor Monitor’s homepage to monitor Door Station.
2. Phonebook
Press up or down button to enter phonebook page. You can dial any residents in
this phonebook.
3. Unlock
Press #+PIN Code+# to unlock.
4. Concierge
Press concierge button to call Master Station.
5. Add Cards by Admin Card
5.1. Add other cards
Step 1: Tap the admin card once;
Step 2: And then tap other cards immediately. Other cards you have tapped can
be used to open the door;
Step 3: Tap the admin card again to finish.
5.2. Delete other cards one by one
Step 1: Tap the admin card twice;

6
Step 2: And then tap other cards immediately. Other cards you have tapped will
be deleted;
Step 3: Tap the admin card again to finish.
5.3. Delete all other cards
Tap the admin card five times. All the other cards will be deleted.
Tips: The admin card can only be used to manage cards. It cannot be used
to open the door.

7
DEVICE SETTING
Connect Door Station and PC to a network switch in the same LAN. You can
enter the admin settings of Door Station by pressing # twice and entering default
password (123456). This is where you can configure the device.
1. Device Settings
Numbers here are basic settings for making a call to Indoor Monitor. For Door
Station, the building and unit number should be the same as those in Indoor
Monitor. For Villa Station with one button, the building, unit, and room number
should be the same as those in Indoor Monitor.
The Index number here is to distinguish different Door Stations when more than
one Door Station in one building.
Mode:
Mode for apt., wall or villa (Unit and wall)
Building:
Number of the building (Building range: 1-999);
Unit:
Number of the unit (Unit range: 1-99);
Index:
Number of the Index (Unit range: 1-9);
Language:
16 languages supported (简体中文, English, 繁體
中文, תי ִרב ִﬠ, Deutsch, Español, Türk, Tiếng Việt,
Nederlands, Português, Polski, Русский, ﻲﺑرﻋ, Fr
ançais, Italiano, slovenský);
Volume:
Volume of System can be set from 1 to 6;

8
Resolution:
3 resolutions supported (320 × 240, 640 × 480, 1
280 × 720, 1920
×
1080);
Password:
Administrator password of the Device (Default 12
3456);
2. Network Settings
The device network can be set to either DHCP or a static IP address. CMS
parameters should be configured here when you try to register this device to
CMS.
DHCP:
Enable DHCP (Dynamic Host Configuration Prot
ocol) to dynamically distributing network configur
ation parameters;
IP:
Configure Static IP address to manually distributi
ng network configuration parameters;
Mask:
Subnet mask;
Gateway:
A component that is part of two networks, which
use different protocols;
DNS:
Domain Name Server of the device;
Server:
Server address of CMS;
3. Access Settings
You can configure access ways like face, PIN Code, cards.
3.1. Face Settings

9
Delete All:
Press 1 and # to delete all face data;
3.2. Password Settings
Add:
Click to add password;
Delete:
Enter password to delete it;
Delete All:
Press 1 and # to delete all passwords;
Check:
Check the password can be used or not;
3.3. Card Settings
Add:
Click to add card;
Delete:
Enter room number to delete cards registered he
re;
Delete All:
Press 1 and # to delete all cards;
3.4. Settings

10
Recognizer:
Enable facial recognition;
Similarity:
sensitivity of facial similarity analyzer (low,
normal, high);
Live Detect:
Sensitivity of live detect (close, normal, high);
Unlock Time:
The length of unlock time (1-9s);
Unlock Delay:
The length of unlock delay time (1-9s);
Elev Refer:
The floor Door Station is installed at (Range: -9-
99);
4. About System
You can find basic information displayed in About System.
Firmware Version:
Firmware version of the device;
IP:
Current IP address of the device;
MAC:
MAC address of the device;
SIP:
Status of SIP registration of the device;

11
WEB SETTING
Connect Door Station and PC to a network switch in the same LAN. You can
enter the IP address of Door Station in the web browser search bar and log in
with the default account (admin) and password (123456). This is where you can
configure the device.
For getting the IP address, you can search by DNAKE Remote Upgrade Tool
which is installed in the same LAN with the devices.
1. General
1.1. General > Information
When you first log in to the web interface, you can find basic information
displayed in this dashboard.

12
Model:
Model of the device;
Firmware Version:
Firmware version of the device;
MAC Address:
MAC address of the device;
Framework:
Framework of the device;
UI:
UI of the device;
MCU:
MCU of the device;
DHCP:
Status of DHCP;
IP Address:
Current IP address of the device;
Mask:
Subnet mask of the device;
Gateway:
Gateway of the device;
DNS:
Domain Name Server of the device;
Account:
SIP account of the device;
Status:
Status of SIP registration of the device;
CMS IP:
IP address of CMS;
Status:
Status of CMS registration;
1.2. General > Basic
Language, resolution and volume of the device can be configured in this column.

13
Language:
16 languages supported (简体中文, English, 繁體
中文, תי ִרב ִﬠ, Deutsch, Español, Türk, Tiếng Việt,
Nederlands, Português, Polski, Русский, ﻲﺑرﻋ, Fr
ançais, Italiano, slovenský);
Resolution:
3 resolutions supported (320 × 240, 640 × 480, 1
280 × 720);
Intercom:
Volume of Intercom can be set from 1 to 6;
System:
Volume of System can be set from 1 to 6;
1.3. General > Time
Time of the device can be configured.
Auto (Time):
Enable to synchronize computer time;
Date&Time:
Date and time can be set manually;
NTP URL:
Network Time Protocol (NTP) is a protocol used t
o synchronize computer time;
Time Zone:
A region that observes a uniform standard time;
12H/24H:
Select 12H or 24H format to display on the devic
e;
Time Format:
3 kinds of time formats supported (YYYY-MM-D
D, DD-MM-YYYY, MM-DD-YYYY);
1.4. General > Password

14
The System password is for the administrator to log in settings on the device
while the Web password is for the administrator to log in settings on the web. The
default password for both of them is 123456.
System Old Password:
Current administrator password of the Device (D
efault 123456);
System New Password:
New administrator password of the Device;
System Confirm Passwor
d:
Confirm administrator password of the Device;
Web Old Password:
Current administrator password of the web (Defa
ult 123456);
Web New Password:
New administrator password of the web;
Web Confirm Password:
Confirm administrator password of the web;
1.5. General > System
The system column is designed for data backup and restore, firmware upgrade,
factory default, device reboot, packet capture, logs capture, and obtaining UI
screenshots.

15
Backup&Restore:
Backup all setting and restore settings;
Upgrade:
Upgrade equipment;
Reset:
Reset to factory settings;
Reboot:
Reboot the device;
Packet Capture:
Capturing packets can help developers reproduc
e positioning problems;
Logs:
Device logs;
Screenshot:
Screenshot device interface;
2. Intercom
2.1. Intercom > Device

16
Numbers here are basic settings for making a call to Indoor Monitor. For Door
Station, the building and unit number should be the same as those in Indoor
Monitor. For Villa Station with one button, the building, unit, and room number
should be the same as those in Indoor Monitor.
The index number here is to distinguish different Door Stations when more than
one Door Station is in one building.
Mode:
Mode for apt., wall or villa (Unit and wall)
Building:
Number of the building (Range: 1-999);
Unit:
Number of the unit (Range: 1-99);
Index:
Number of the device (Range: 1-9);
2.2. Intercom > Network
The device network can be set to either DHCP or a static IP address. CMS
parameters should be configured here when you try to register this device to
CMS.
Table of contents
Other Dnake Intercom System manuals