Dnake H618 User manual

User Manual
———
DNAKE H618


REMARK
Please follow the user manual for correct installation and testing. If there is any
doubt please call our tech-supporting and customer center.
Our company applies ourselves to reformation and innovation of our products. No
extra notice for any change. The illustration shown here is only for reference. If
there is any difference, please take the actual product as the standard.
The product and batteries must be handled separately from household waste.
When the product reaches the end of service life and needs to be discarded,
please contact the local administrative department and put it in the designated
collection points in order to avoid the damage to the environment and human
health caused by any disposal. We encourage recycling and reusing the material
resources.

CATALOG
PRODUCT FEATURE ............................................. 1
TECHNICAL PARAMETER ..................................... 1
PACKAGE CONTENT ............................................. 2
OVERVIEW.............................................................. 3
BASIC OPERATION ................................................ 4
DEVICE SETTING ................................................. 13
WEB SETTING ...................................................... 19
SYSTEM DIAGRAM .............................................. 35
DEVICE WIRING ................................................... 36
INSTALLATION...................................................... 38
TROUBLESHOOTING........................................... 40
SAFETY INSTRUCTION ....................................... 41

1
PRODUCT FEATURE
1. Android 10 System
2. 10.1-inch LCD
3. Powered by PoE or power adapter (DC12V/2A)
4. Support SIP 2.0 protocol, easy integration with other SIP devices
5. Compatible with 3rd party application
6. Support monitoring 16 IP cameras
TECHNICAL PARAMETER
System: Android 10
RAM: 2 GB
ROM: 8 GB
Front Panel: Aluminum
Power Supply: PoE (802.3af) or DC 12V/2A
Standby Power: 3 W
Rated Power: 10 W
Wi-Fi: IEEE802.11 b/g/n,@2.4GHz (Optional)
TF Card Slot: 1
Ethernet Port: 1 x RJ45, 10/100 Mbps adaptive
Resolution: 1280 x 800
Working Temperature: -10℃to +55℃
Storage Temperature: -40℃to +70℃
Working Humidity: 10% to 90% (non-condensing)

2
PACKAGE CONTENT
MODEL: H618
H618 Bracket PM4×20 (2 pcs) Diode (8 pcs) Wires
Quick Start Guide

3
OVERVIEW

4
BASIC OPERATION
1. Icon Customization
Users can decide on icons on the 1st homepage. Users just need to press and
hold for seconds on the icon to customize. Icons can be deleted or changed to
other icons including 3rd party apps. And press √to confirm or press ×to cancel.
2. Call
Go to Call > Dial and enter Building number + Building + Unit number + Unit +
Room number + dial icon to call Indoor Monitor (such as 1 + Building + 1 + Unit +
1111 + Dial button). Or you can press Concierge here to call Master Station.
3. Doors
Click Doors icon on Indoor Monitor’s homepage to monitor Door Station. You can
unlock by clicking door icon or switch to monitor other devices by clicking arrow or
the name above.

5
4. Message
Indoor Monitor can only receive the message sent by the CMS or Master Station.
Up to 64 records can be received in SMS.
5. DND
Click DND icon to enable do not disturb function. No calls can call in.
6. Quad Splitter
Click Quad Splitter icon on Indoor Monitor’s homepage to monitor IPC. Click any
screen of IPC to make it full screen. Click left or right arrow to check other pages.
Up to 16 IPC can be added.

6
7. Phonebook
Slide from left to right near the left edge of the screen to wake up phonebook
page.
Or go to Call > Phonebook. Select the name on the phonebook and press dial
button to call.
8. QR Code
Click QR Code and scan by DNAKE Smart Life app to add this Indoor Monitor to
your phone. Only when the license is filled in Internet-connected Indoor Monitor,
QR code will be available.

7
9. Security
Security is for sensors. The default password is 1234.
8.1. ON/OFF
ON:
Click Out, Home, or Sleep icon to activate the
scene for alarm sensors, the icon on the main
interface will light up with a beep sound;
OFF:
Click OFF to disable scene;
8.2. Zone

8
Type:
•Normal: When users enable an alarm scene on
the On/Off page, Normal type alarm zone will
be activated after activation time.
o100 seconds is the default activation time, it
means the alarm will be activated after 100
seconds.
oAfter 100s, once sensor is triggered, Indoor
Monitor will send this alarm to Master
Station.
oBut sometimes users don't want to send the
alarm to Master Station (maybe alarm by
mistake), users can set the Delay time, so
they can cancel the alarm in the Indoor
Monitor during this Delay time (PIR, Door,
Window);
•Emergency: once Panic button is triggered,
Indoor Monitor will not initiate an alarm and
only Master Station will receive alarms
secretly; 24 hours standby even if the security
is off (Panic, Pull Cord);
24 Hour: Indoor Monitor will initiate an alarm and
Master Station will also receive alarms. 24 hours
standby even if the security is off (Smoke, Gas,
Flood);
Mode:
•3C: for the sensor with 2.2KΩ resistance;
Regardless of the connection to NC or NO, the
alarm can be triggered normally;
•NO: normally open;
•NC: normally closed;
BELL: in BELL mode, Master Station will not
receive any alarm. Indoor Monitor is regarded as
a doorbell receiver;
Delay:
Once sensor is triggered, Indoor Monitor will
send this alarm to Master Station, but users can
terminate the alarm sending to Master Station

9
during the delayed time set here. Delay setting is
only effective for Normal type (0s, 5s, 15s, 20s,
25s, 40s, 60s);
Sensor:
Sensor types (Smoke, Gas, PIR, Door, Window,
Panic, Flood, Pull Cord);
8.3. Scene
Activation Time:
Only after activation time, will scene be
activated. Activation time is only effective for
Normal type (NONE, 30s, 40s, 60s, 100s, and
300s);
Mode:
Tick to link sensors to Out, Home, or Sleep
scene;
8.4. Settings
Old:
Current security password of the Device (Default
123456);
New:
New security password of the Device;
Confirm:
Confirm security password of the Device;
10. Concierge
Press the Concierge icon to call Master Station one by one.

10
11. Elevator
Press the Elevator icon to call control elevator (DNAKE Elevator Control Module
is needed).
12. Add More Indoor Monitors
Keep Building, Unit, Apartment No., Sync the same as other Indoor Monitors, and
Device number should be different. The Device number can be from 0 to 9. But
you must have one Indoor Monitor’s Device number is 0 and keep it online
because 0 here stands for the main one.
Or go to Indoor Monitor’s webpage and find Ex Phone in Intercom > Call. Users
can directly extend to more Indoor Monitors by filling in sip:IP address (6 Max)

11
such as sip:192.168.68.90. (Please refer to WEB SETTING for the way to access
to webpage)
13. SIP Setting
Users can directly configure SIP on the device’s Settings > More > SIP page.
14. SOS
Users can press SOS icon on the 2nd homepage to send SOS to Master Station.
Users can set the trigger time length on the webpage. If the time is set to 3s,
users need to press the SOS icon for 3s to send out SOS in case of a wrong
operation alarm.

12

13
DEVICE SETTING
Connect Indoor Monitor and other devices to a network switch in the same LAN.
Go to Settings to configure the device.
1. Display
Brightness level:
Screen brightness adjustment;
Sleep:
Screen sleep time (15s, 30s, 1min, 2mins,
5mins, 20mins, 30mins);
Approach to Wake:
Get close to device to wake screen;
2. Intercom
System Vol:
Volume of System can be set from 1 to 6.
Volume 6 is the maximum volume (Key tone);

14
Intercom Vol:
Volume of Intercom can be set from 1 to 6.
Volume 6 is the maximum volume (Call volume);
Ringtone:
The ringing sound (Ringtone 01-04);
Key Tone:
The keytone (Enable or disable);
Auto Answer:
Pick up automatically when receiving a call;
3. Date & Time
Automatic date & time:
Enable to synchronize computer time;
Time Zone:
A region that observes a uniform standard time;
12H/24H:
Select 12H or 24H format to display on the
device;
NTP:
Network Time Protocol (NTP) is a protocol used
to synchronize computer time;
4. Language
Language:
16 languages supported (
简体中文
, English,
繁體
中文, תי ִרב ִﬠ, Deutsch, Español, Türk, Tiếng Việt,
Nederlands, Português, Polski, Русский, ﻲﺑرﻋ,
Français, Italiano, slovenský);
5. Doors

15
You need to click search icon to add Door Stations to Indoor Monitor and click tick
to save before monitoring. Click funnel icon to pin the selected device to the top.
Click pen icon to edit devices.
6. Version
Firmware:
Firmware version of the device;
IP:
Current IP address of the device;
Wi-Fi IP:
Current Wi-Fi IP address of the device;
MAC:
MAC address of the device;
SIP:
Status of SIP registration of the device;
Reboot:
Reboot the device;
7. More > Ethernet
The device network can be set to either DHCP or a static IP address. CMS
parameters should be configured here when you try to register this device to
CMS.

16
DHCP:
Enable DHCP (Dynamic Host Configuration
Protocol) to dynamically distributing network
configuration parameters;
IP:
Configure Static IP address to manually
distributing network configuration parameters;
Mask:
Subnet mask;
Gateway:
A component that is part of two networks, which
use different protocols;
DNS:
Domain Name Server of the device;
CMS IP:
Server address of CMS;
Password:
Password you set for this device’s CMS
registration;
Current IP:
Current IP address of the device;
8. More > Wi-Fi
Wi-Fi:
Enable to connect to Wi-Fi;
9. More > Room
Table of contents
Other Dnake Intercom System manuals