SVA 4xxx Commissioning instructions
060648-45532 – 05/2023 3
3.3 Technical data
Status messages via potential-free contacts
Contact load capacity: 100mA at max. 30 V DC
Protection category: IP54
Tubular
frame locks
Solid door
locks
Rear backset: 15mm 33mm
Distance between
door handle and
locking cylinder:
92mm
for profile
cylinder
94mm
for round
cylinder
72 mm
profile
cylinder
74 mm round
cylinder
Bolt throw: 20mm 20mm
Temperature range: -25°C to +70°C
Relative humidity: up to 95% at 55°C;
no condensation
3.4 Variants
Variants for rebated solid doors
Forend: 235 x 20mm, for profile cylinder:
• SVA4271: Backset 65mm, DIN left
• SVA4272: Backset 65mm, DIN right
• SVA4281: Backset 80mm, DIN left
• SVA4282: Backset 80mm, DIN right
• SVA4291: Backset 100mm, DIN left
• SVA4292: Backset 100mm, DIN right
Forend: 235 x 20mm, for round cylinder:
• SVA4371: Backset 65mm, DIN left
• SVA4372: Backset 65mm, DIN right
• SVA4381: Backset 80mm, DIN left
• SVA4382: Backset 80mm, DIN right
• SVA4391: Backset 100mm, DIN left
• SVA4392: Backset 100mm, DIN right
Variants for solid butt doors
Forend: 235 x 24mm, for profile cylinder:
• SVA4277: Backset 65mm, DIN left/right
• SVA4287: Backset 80mm, DIN left/right
• SVA4297: Backset 100mm, DIN left/right
Forend: 235 x 24mm, for round cylinder:
• SVA4377: Backset 65mm, DIN left/right
• SVA4387: Backset 80mm, DIN left/right
• SVA4397: Backset 100mm, DIN left/right
Variants for tubular frame doors
Forend: 270 x 24, for profile cylinder:
• SVA4719: Backset 35mm, DIN left/right
• SVA4729: Backset 40mm, DIN left/right
• SVA4739: Backset 45mm, DIN left/right
Forend: 270 x 24, for round cylinder:
• SVA4819: Backset 35mm, DIN left/right
• SVA4829: Backset 40mm, DIN left/right
• SVA4839: Backset 45mm, DIN left/right
3.5 Classification
Tubular frame locks
dormakaba Deutschland GmbH
DORMA Platz 1 - 58256 Ennepetal
0432-CPR-00026-96 18
SVA4xxxRR EN 12209:2003/
AC:2005 3 X 6 1 0 G 7 B B 2 0
DOP_0164
0432-CPR-00026-11 18
SVA4xxxRR EN 179:2008 3 7 7 B 1 4 5 2 A A
DOP_0166
0432-CPR-00026-01 18
SVA4xxxRR EN 1125:2008 3 7 7 B 1 4 2 1/2 A/B A
DOP_0167
Solid door locks
dormakaba Deutschland GmbH
DORMA Platz 1 - 58256 Ennepetal
0432-CPR-00026-19 15
SVA4xxxVB EN 12209:2003/
AC:2005 3 X 9 1 0 G 7 B B 2 0
DOP_0160
0432-CPR-00026-11 17
SVA4xxxVB EN 179:2008 3 7 7 B 1 4 5 2 A A
DOP_0162
0432-CPR-00026-02 17
SVA4xxxVB EN 1125:2008 3 7 7 B 1 4 2 1/2 A/B A
DOP_0163
4 Pin assignment
Note
For earthed door frames, the bridge on the
SVP-A x100 connection cable’s plug must be
disconnected.