DSC PC5132-433 User manual

Installation
Manual
PC5132-433 NA
Version 4.2
• W A R N I N G •
This manual contains information on limitations regarding
product use and function and information on the limitations as to
liability of the manufacturer.

WARNING Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact
with system users, it is your responsibility to bring each item in this warn-
ing to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible.
There are circumstances, however, involving fire, burglary, or other
types of emergencies where it may not provide protection. Any alarm
system of any type may be compromised deliberately or may fail to
operate as expected for a variety of reasons. Some but not all of these
reasons may be:
■■
■■
■ Inadequate Installation
A security system must be installed properly in order to provide ad-
equate protection. Every installation should be evaluated by a security
professional to ensure that all access points and areas are covered.
Locks and latches on windows and doors must be secure and operate
as intended. Windows, doors, walls, ceilings and other building mate-
rials must be of sufficient strength and construction to provide the
level of protection expected. A reevaluation must be done during and
after any construction activity. An evaluation by the fire and/or police
department is highly recommended if this service is available.
■■
■■
■ Criminal Knowledge
This system contains security features which were known to be effec-
tive at the time of manufacture. It is possible for persons with criminal
intent to develop techniques which reduce the effectiveness of these
features. It is important that a security system be reviewed periodically
to ensure that its features remain effective and that it be updated or
replaced if it is found that it does not provide the protection expected.
■■
■■
■ Access by Intruders
Intruders may enter through an unprotected access point, circumvent
a sensing device, evade detection by moving through an area of insuf-
ficient coverage, disconnect a warning device, or interfere with or
prevent the proper operation of the system.
■■
■■
■ Power Failure
Control units, intrusion detectors, smoke detectors and many other
security devices require an adequate power supply for proper opera-
tion. If a device operates from batteries, it is possible for the batteries
to fail. Even if the batteries have not failed, they must be charged, in
good condition and installed correctly. If a device operates only by AC
power, any interruption, however brief, will render that device inop-
erative while it does not have power. Power interruptions of any length
are often accompanied by voltage fluctuations which may damage
electronic equipment such as a security system. After a power inter-
ruption has occurred, immediately conduct a complete system test to
ensure that the system operates as intended.
■■
■■
■ Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide sev-
eral years of battery life under normal conditions. The expected bat-
tery life is a function of the device environment, usage and type. Am-
bient conditions such as high humidity, high or low temperatures, or
large temperature fluctuations may reduce the expected battery life.
While each transmitting device has a low battery monitor which iden-
tifies when the batteries need to be replaced, this monitor may fail to
operate as expected. Regular testing and maintenance will keep the
system in good operating condition.
■■
■■
■ Compromise of Radio Frequency
(Wireless Devices
Signals may not reach the receiver under all circumstances which could
include metal objects placed on or near the radio path or deliberate jam-
ming or other inadvertent radio signal interference.
■■
■■
■ System Users
A user may not be able to operate a panic or emergency switch possi-
bly due to permanent or temporary physical disability, inability to reach
the device in time, or unfamiliarity with the correct operation. It is
important that all system users be trained in the correct operation of
the alarm system and that they know how to respond when the system
indicates an alarm.
■■
■■
■ Smoke Detectors
Smoke detectors that are a part of this system may not properly alert
occupants of a fire for a number of reasons, some of which follow. The
smoke detectors may have been improperly installed or positioned.
Smoke may not be able to reach the smoke detectors, such as when the
fire is in a chimney, walls or roofs, or on the other side of closed doors.
Smoke detectors may not detect smoke from fires on another level
of the residence or building.
Every fire is different in the amount of smoke produced and the
rate of burning. Smoke detectors cannot sense all types of fires
equally well. Smoke detectors may not provide timely warning
of fires caused by carelessness or safety hazards such as smoking
in bed, violent explosions, escaping gas, improper storage of flam-
mable materials, overloaded electrical circuits, children playing
with matches or arson.
Even if the smoke detector operates as intended, there may be cir-
cumstances when there is insufficient warning to allow all occu-
pants to escape in time to avoid injury or death.
■■
■■
■ Motion Detectors
Motion detectors can only detect motion within the designated ar-
eas as shown in their respective installation instructions. They can-
not discriminate between intruders and intended occupants. Mo-
tion detectors do not provide volumetric area protection. They have
multiple beams of detection and motion can only be detected in
unobstructed areas covered by these beams. They cannot detect
motion which occurs behind walls, ceilings, floor, closed doors,
glass partitions, glass doors or windows. Any type of tampering
whether intentional or unintentional such as masking, painting, or
spraying of any material on the lenses, mirrors, windows or any
other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in
temperature. However their effectiveness can be reduced when the
ambient temperature rises near or above body temperature or if
there are intentional or unintentional sources of heat in or near the
detection area. Some of these heat sources could be heaters, radia-
tors, stoves, barbeques, fireplaces, sunlight, steam vents, lighting
and so on.
■■
■■
■ Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not
warn people or waken someone sleeping if there is an interven-
ing wall or door. If warning devices are located on a different
level of the residence or premise, then it is less likely that the
occupants will be alerted or awakened. Audible warning devices
may be interfered with by other noise sources such as stereos,
radios, televisions, air conditioners or other appliances, or pass-
ing traffic. Audible warning devices, however loud, may not be
heard by a hearing-impaired person.
■■
■■
■ Telephone Lines
If telephone lines are used to transmit alarms, they may be out of
service or busy for certain periods of time. Also an intruder may cut
the telephone line or defeat its operation by more sophisticated means
which may be difficult to detect.
■■
■■
■ Insufficient Time
There may be circumstances when the system will operate as in-
tended, yet the occupants will not be protected from the emer-
gency due to their inability to respond to the warnings in a timely
manner. If the system is monitored, the response may not occur in
time to protect the occupants or their belongings.
■■
■■
■ Component Failure
Although every effort has been made to make this system as reli-
able as possible, the system may fail to function as intended due
to the failure of a component.
■■
■■
■ Inadequate Testing
Most problems that would prevent an alarm system from operating
as intended can be found by regular testing and maintenance. The
complete system should be tested weekly and immediately after a
break-in, an attempted break-in, a fire, a storm, an earthquake, an
accident, or any kind of construction activity inside or outside the
premises. The testing should include all sensing devices, keypads,
consoles, alarm indicating devices and any other operational de-
vices that are part of the system.
■■
■■
■ Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute
for property or life insurance. An alarm system also is not a sub-
stitute for property owners, renters, or other occupants to act pru-
dently to prevent or minimize the harmful effects of an emer-
gency situation.

Introduction 1
1.1 How to Use this Manual.........................................................................1
1.2 Specifications and Features ................................................................. 1
1.3 Compatible Wireless Devices ............................................................... 2
1.4 Batteries ................................................................................................ 2
PC5132-433 Set up & Wiring 3
2.1 Unpack the PC5132 .............................................................................. 3
2.2 Choose a Mounting Location for the PC5132 ....................................... 3
2.3 Antennas ............................................................................................... 3
2.4 Connect the PC5132-433 Receiver ...................................................... 3
Enrolling Wireless Devices 4
3.1 A Note about Electronic Serial Numbers ..............................................4
3.2 Enrolling Wireless Devices .................................................................... 4
3.3 Enroll & Program Wireless Keys (WLS9X9-433) ................................... 4
3.4 Identified Wireless Keys ....................................................................... 6
Other Programming 7
4.1 Program Zones and Partitions .............................................................. 7
4.2 Enable PC5132-433 Supervision ..........................................................7
4.3 Enable Supervision of Wireless Zones ................................................. 8
4.4 Jamming Signal Detection .................................................................... 8
4.5 PC5132-433 Software Default ............................................................... 9
4.6 Deleting Wireless Devices ....................................................................9
Testing & Mounting 10
5.1 Test the Reception of Wireless Devices .............................................. 10
5.2 Mount the PC5132-433 and Wireless Devices ................................... 12
Additional Notes 13
6.1 Trouble Conditions .............................................................................. 13
6.2 Jamming Signal Detection .................................................................. 13
6.3 Wireless Zone Low Battery Transmission ........................................... 13
Troubleshooting 14
Programming Worksheets 15
Guidelines for Locating Smoke Detectors 20
Index 21
Table of Contents
C O N T E N T S

Thank you for purchasing the PC5132-433 Wireless Receiver. This product
is the result of several years of development and will allow you to connect
up to 32 wireless detection devices to the PC580, PC1555, and the Power series
control panels.
The PC5132-433 uses 433 MHz. It provides several advantages:
• supervisory transmissions are sent every 64 minutes
• programmable supervisory window can be as long as 24 hours
• diversity antenna arrangement for better RF reception
In addition, the PC5132-433 features:
•6 digit serial numbers for all wireless devices: These new serial numbers
include hexadecimal digits.
Please read Section 3.1 “A note on Electronic
Serial Numbers (ESN)” for more information on enrolling 6-digit devices.
We are confident you will find the PC5132-433 Wireless Receiver a unique and useful
control panel enhancement.

1
This manual describes how to install, program and maintain the PC5132-433.
Before you install the PC5132-433 module, you should complete the following steps
in your system installation:
1. Plan the installation and wiring of the security system (see your system
Installation Manual
).
2. Install the control panel, and install and enroll at least one keypad to use for
programming.
3. Install and enroll any hardwired zone expander modules (PC5108) you plan to use.
NOTE: PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g., zones
9-12 and zones 13-16). None of the zones assigned to a PC5108 module can be
used for wireless devices.
Program the PC5132-433 from a system keypad or using downloading software on
a remote computer (e.g. DLS-3). Read your system
Installation Manual
for more
information.
1.1 How to Use this Manual
Read this manual before you begin installing the PC5132-433. To install and set up the
PC5132-433 and wireless devices, follow these steps. Refer to the sections listed below.
1. Temporarily mount and wire the PC5132-433 module (see
Section 2
).
2. Enroll and program wireless devices (see
Section 3
).
3. Complete zone and other programming on the system (see
Section 4
).
4. Test the placement of all the wireless devices
(see Section 5).
5. Permanently mount the PC5132-433 receiver and wireless devices
(see Section 5).
For additional information on trouble conditions, RF jamming signal detection and
battery replacement, see
Section 6.
For help with troubleshooting, see
Section 7.
1.2 Specifications and Features
• Current Draw: 80 mA
• Frequency: 433 MHz
• Zones - receiver can receive signals from up to 32 wireless zones and 16
wireless keys
• Antenna - diversity design for enhanced performance
• Supervisory - programmable supervisory window, 8 to 24 hours, in 15 minute
increments
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Keybus
- for longer wire runs, thicker gauge wire must be used.
• Compatibility: The PC5132-433 v4.X can be connected to the following
panels: PC501X, PC5020, PC1555, PC580
S E C T I O N 1
Introduction

2
1.3 Compatible Wireless Devices
Please refer to the Instruction sheets of the following devices for more information.
The PC5132-433 v4.X can receive signals from the following devices:
• WLS904P-433 Motion Detector • WLS912-433 Glass Break Detector
• WLS906-433 Smoke Detector • WLS907-433 Door/Window Contact
• WLS914-433 Pet-Immune PIR • WLS909-433 Wireless Key
• WLS919-433 Wireless Key • WLS925L-433 Mini Door/Window Contact
1.4 Batteries
The wireless devices, with the exception of the WLS925L transmitter and the
WLS919-433 wireless key, are designed to use only Energizer Alkaline batteries (by
Eveready). For the WLS919-433, use only FDK CR2032 type lithium batteries.
NOTE: Do not use other brands of batteries. Using any other brand may affect sys-
tem operation.
I N T R O D U C T I O N

3
S E C T I O N 2
This section describes how to set up and wire the PC5132-433 module.
2.1 Unpack the PC5132-433
Check that the following parts are in your PC5132-433 package:
• PC5132-433 PCB • Diversity antennae
• PC5132-433 plastic cabinet • Hardware for mounting the cabinet
2.2 Choose a Mounting Location for the PC5132-433
NOTE: Mount the PC5132-433 receiver and wireless devices after you have done
placement tests with the wireless devices (see sections 5.1 and 5.2).
Find a place that is:
• Dry
• Central to the proposed placement of all wireless devices
• As high as possible
• Far from sources of interference, including: electrical noise (computers,
televisions and electric motors in appliances and heating and air
conditioning units); large metal objects like heating ducts and plumbing
which may shield the antenna.
Make sure that electrical wires will not run over the antenna(s) of the module when
it is mounted.
When mounting the PC5132-433 in a basement, place the module as high and as
close to the underside of the first floor as possible. The range of the module will be
reduced if the unit is mounted below ground level.
2.3 Installing the Antennas
The two antennas must be screwed into the terminals marked ANT1 and ANT2, not GND1
and GND2. Also they must be installed as indicated in the following two diagrams:
Do not install the antennas as indicated in the following diagrams:
If the antennas are installed incorrectly the PC5132-433 may not
reliably receive signals from the transmitters.
2.4 Connect the PC5132-433 Receiver
CAUTION: Remove all power from the system
while connecting modules to the Keybus.
Connect the PC5132-433 to the four-wire Keybus
of the control panel according to the following
diagram.
After you have completed the wiring, reconnect
the power to the security system.
Now that you have wired the PC5132-433, you should enroll and program the
wireless devices. See section 3 for instructions.
PC5132-433 Set Up & Wiring

4
This section describes how to enroll wireless devices (WLS904P-433, WLS906-433, WLS907-
433, WLS912-433, WLS914-433 and WLS925L-433), and wireless keys (WLS909-433 and
WLS919-433). For more information on these devices, read the instruction sheet included with
each device.
3.1 A Note about Electronic Serial Numbers
An electronic serial number (ESN) is printed on the back of each wireless device. ESNs
are used to enroll the wireless devices with the PC5132-433 receiver.
In order to reduce the occurrence of wireless devices with the same serial number, 6-digit
serial numbers are now printed on the back of each wireless device. The 6-digit serial
numbers include hexadecimal digits. For instructions on programming hexadecimal
numbers, see your system Installation Manual, Section 4: How to Program.
NOTE: 6-digit serial numbers are only supported on the following control panels:
PC5020, PC501X, PC1555 and PC580 v2.0 and higher.
The WLS904P-433, WLS906-433, WLS907-433, WLS912-433, WLS914-433 and
WLS925L-433 devices have both a 5-digit and a 6-digit serial number printed on
them. When connecting the PC5132-433 to a PC5010 v1.x panel, enter 5-digit serial
numbers only. When connecting the PC5132-433 to a PC5020 or PC5015 v2.x and
higher, PC5010, PC1555, or PC580 panel enter the 6-digit serial number.
3.2 Enrolling Wireless Devices
1. At a system keypad, enter [✱][8][Installer’s code] to go to the installer’s
programming section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to occupy
([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-
16). None of the zones assigned to a PC5108 module may be used for wireless devices.
For more information on zone assignment, consult your system Installation Manual.
4. Enter the device’s ESN. Follow the instructions in section 3.1 above.
5. Record the serial number and the assigned zone number in the programming
worksheets in the back of this manual.
6. Continue with steps 3 - 5 until you have enrolled all wireless devices.
7. To exit press [#]. The device is now enrolled on the system.
NOTE: The devices will not work properly until you complete zone and partition pro-
gramming (see section 4).
3.3 Enroll & Program Wireless Keys
For wireless keys to work on the system, you need to enroll them and then program the
function buttons. Wireless keys are not assigned to zones and require no zone
programming. You can enroll up to 16 wireless keys on the system.
NOTE: Control units must have the ‘Arm/Disarm Bell Squawk’ feature enabled when
using wireless key devices. The bell squawk must be heard outside of the home.
S E C T I O N 3
Enrolling Wireless Devices

5
Enroll Wireless Keys
1. At a system keypad, enter [✱][8][Installer’s code] to go to the Installer’s
Programming section.
2. Enter programming section [804].
3. Enter a 2-digit number [41]-[56] to assign the wireless key a slot. These
numbers correspond to wireless key numbers 01-16.
4. Enter the key’s ESN. The entry
must
be six digits. If an older key with a 5-
digit ESN is being enrolled, add the digit [0] to the beginning of the ESN.
(E.g. ESN=61234, enter 061234)
5. The key is now enrolled on the system. Record the serial number and the
assigned slot number in the programming worksheets in the back of this
manual.
6. Repeat steps 3 - 5 until all wireless keys have been enrolled.
7. ((
((
(PC5020 /PC5020 /
PC5020 /PC5020 /
PC5020 / PC501PC501
PC501PC501
PC501XX
XX
Xonly)only)
only)only)
only) By default, all wireless keys are assigned to
Partition 1. To assign keys to Partition 2, enable the appropriate options in
programming sections [91] and [92].
NOTE: A wireless key can only be assigned to one partition.
8. To exit press [#].
Program the WLS909-433 or WLS919-433 Function Buttons
WLS909-433 and WLS919-433 wireless keys have four programmable function
buttons. You must program a set of four functions for the buttons before any keys will
work. After the functions are programmed, when you press and hold one of the four
buttons for two seconds, the system will execute the programmed function.
For systems not using partitions: program the function buttons in section [59]. All
wireless keys will have the same four functions.
For systems using partitions (PC5020 / PC501X only): all wireless keys assigned
to Partition 1 will have the four functions programmed in section [59]. All wireless keys
assigned to Partition 2 will have the four functions programmed in section [60]. For
example, if function button 1 in Section [59] is programmed for Stay arming, then
pressing the first button on wireless keys assigned to Partition 1 will Stay arm Partition
1.
NOTE: Wireless keys will not work when the partition they are assigned to is being
accessed for zone bypassing or programming.
1. At a system keypad, enter [✱][8][Installer’s code].
2. Enter programming section [804].
3. Enter programming section [59] for keys assigned to partition 1, or [60] for
keys assigned to partition 2.
4. For each of the 4 function buttons, enter the 2-digit number of the function
you want to select. See the programming worksheets in the back of this
manual for a list of function key options.
5. Record your programming choices in the worksheets in the back of the manual.
6. To exit press [#].
W I R E L E S S D E V I C E S

6
3.4 Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and
command output [✱][7] activation by wireless key buttons may be supported on
certain control panels. To do this, the system will reserve access codes 17 – 32 for
wireless keys 01-16 respectively. You must program one access code for each
wireless key (using [✱][5] access code programming) for this feature to work
correctly.
NOTE: Program these access codes on the system
after
you have connected the
PC5132-433 to the Keybus (see section 2.4).
Refer to your system Installation Manual for information on access code program-
ming.
Opening/Closing By Wireless Key Reporting
NOTE: The Identified Wireless Key Closing option is only available with the PC5020 or
PC501X, PC1555, PC580 v2.0 and higher by turning section [015] option 4 off.
To enable the reporting of openings and closings
by identified wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing and opening reporting code for each key’s access code
• Turn off the Quick Arm option in section [015] option [4] of the control panel
programming
To ensure that an
unidentified wireless key
cannot disarm the system, turn off section
[017], option [1] (in the control panel programming). This option is available in control
panels with software version 2.1 or higher.
Command Output Activation
NOTE: The Identified Wireless Key Command Output Activation feature is only avail-
able with the PC5020, PC501X, PC1555 and PC580 v2.0 and higher.
To enable command output activation by wireless keys, ensure that:
• The control panel is v2.0 or higher
• Program a valid access code for each key
• Enable the PGM output attribute Requires Access Code for each PGM
output programmed as [✱][7][1-4] in sections [141] to [154] ([501] to [514]
for the PC5020).
Now that you have enrolled all the wireless devices, you will need to program the
system to work properly with the devices. See section 4 for more information.
W I R E L E S S D E V I C E S

7
4.1 Program Zones and Partitions
Now that you have enrolled the wireless devices, you should complete all zone
programming on the system. Although the exact programming required varies
depending on which control panel the PC5132-433 is connected to, you should
check that the following programming areas are completed correctly for each
wireless zone:
• Enable zones and/or assign zones to one or more partitions (programming
sections [202]-[205] or [202] to [265] for the PC5020).
• Program the definition for each zone (programming sections [001]-[004]).
• Enable the wireless zone attribute for each wireless zone (PC580, PC1555,
PC501X v2.0, PC5020 v3.0 and higher only) (sections [101]-[132]).
See your system Installation Manual, for more information on each of the above
programming sections.
4.2 Enable PC5132-433 Supervision
The control panel will supervise the PC5132-433 receiver via the Keybus after at least
one device has been enrolled on the module (see section 3.2 “Enrolling Wireless
Devices”).
To activate module supervision, after you enroll the first device(s):
1. Exit and then re-enter installer’s programming
2. Enter programming section [902]. Wait approximately 1 minute.
3. To exit press [#].
The system will generate a General System Supervisory trouble if the module is
removed from the Keybus. If you need to remove the PC5132-433 module from an
existing system, you will have to disable supervision of the PC5132-433.
NOTE: Deleting all devices from the PC5132-433 or defaulting the PC5132-433 will
cause a supervisory fault
To disable PC5132-433 supervision:
1. Disconnect the PC5132-433 from the Keybus
2. Enter [✱][8][Installer Code]
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [✱][8][Installer’s Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate
that the PC5132-433 is present on the system. On LCD keypads, scroll until
the module name appears on the display.
3. To exit press [#].
S E C T I O N 4
Ot er Programming

8
If the PC5132-433 module does not show on the keypad, one of the following
conditions may be present:
• the module is not connected properly to the Keybus
• there is a problem with the Keybus wiring run
• the module does not have enough power
• no devices have been enrolled on the PC5132
4.3 Enable Supervision of Wireless Zones
NOTE: (for PC5010 v1.x control panels only) In order for wireless zones to be super-
vised, you must enable Double End of Line (DEOL) supervision in the PC5010 con-
trol panel. For more information, refer to your Installation Manual.
NOTE: (PC5020, PC501X, PC1555, PC580 v2.0 and higher only) For wireless su-
pervision to work, you must enable the wireless zone attribute on all wireless zones
(sections [101] to [132], option [8] ON).
Wireless Supervisory Window
Each wireless zone (WLS906-433,WLS904P-433 or WLS925L-433) will send a supervi-
sory signal every 64 minutes. If the receiver does not receive a signal within the time
programmed for the Wireless Supervisory Window, it will generate a supervisory fault.
To program the wireless supervisory window:
1. Enter [✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132-433 Module Programming.
3. Enter section [81].
4. Enter the time period for the supervisory window. The window is programmed
in 15 minute increments. The default programming is 96 (x15minutes), which
is equal to 24 hours. Valid entries are (32) - (96), equal to 8 - 24 hours.
5. To exit press [#].
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision for
any zone, enter the following at any system keypad:
1. Enter [✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132-433 Module Programming.
3. Enter sections [82], [83], [84] and [85]. Enable or disable supervision for
each wireless zone by turning each relevant option on or off.
4. To exit press [#].
4.4 RF Jam Detect Zone
For RF jamming detection to work, you must select an unused zone to be used as the
RF Jam Detect zone. When the receiver detects an attempt to jam the RF signal, the
RF Jam Detect zone will be violated and the system will generate a tamper signal.
When the jamming signal is gone, the RF Jam Detect zone closes and the system
sends a tamper restore signal.
To enable RF jamming detection:
1. Enter [✱][8] [Installer’s Code].
2. Enter programming section [804].
3. Select an unused zone to be the RF Jam Detect zone. Enter the 2-digit
number ([01] to [32]) of the RF Jam Detect zone on the keypad, then program
the serial number as [200000].
O T H E R P R O G R A M M I N G

9
O T H E R P R O G R A M M I N G
4. Enter section [93]. Enter the 2-digit number of the RF Jam Detect zone ([01]
to [32]) in the programming section.
5. Disable supervision for the RF Jam detect zone by turning the relevant option off in
section [82], [83], [84] or [85]. (See section 4.3 for more information.)
6. RF jamming detection is now enabled. To exit Installer programming, press [#].
4.5 PC5132-433 Software Default
Returning the PC5132-433 programming to factory default settings is a quick way to
remove all the enrolled devices from the system and reset all the programming in
section [804].
NOTE: Performing this procedure will not change any programming sections except
[804]. Resetting the control panel to factory default settings will
not
return the PC5132-
433 module to factory default settings.
To restore the PC5132-433 programming to the factory default settings:
1. Enter [✱][8] [Installer’s Code].
2. Enter programming section [996].
3. Enter the Installer’s Code, followed by [996] again. The software for the
PC5132-433 will be restored to its factory default settings.
4. To continue programming the unit, exit installer’s programming by pressing
[#] and then re-enter installer’s programming by entering [✱][8] [Installer’s
Code].
For instructions on restoring the default programming of the control panel or any
other connected module, see your system
Installation Manual.
4.6 Deleting Wireless Devices
To remove a wireless device from the system, follow the guideline for enrolling a
wireless device (see section 3.2). Program the ESN as [000000]. The wireless device
for the zone will be removed.
NOTE: You may need to remove power from the panel in order to clear troubles
caused by deleted zones.
Now that you have completed all PC5132-433 related programming, you can test
and mount the receiver and devices. See section 5 for more information.

10
Testing & Mounting
S E C T I O N 5
5.1 Test the Reception of Wireless Devices
It is very important to test the proposed placement of each wireless device before it is
mounted. Following these steps will test the signal strength between the PC5132-433
and the wireless devices.
You can test all of the devices together (global placement testing) or test each device
individually. To test all the devices together, see ‘Testing All Wireless Devices
Together’ below. To test wireless devices individually, see ‘Testing Individual
Devices’.
After you have enrolled the wireless devices, you must exit and then
re-enter Installer’s Programming at least once before you can perform a
placement test.
Testing All Wireless Devices Together:
1. Temporarily put the WLS904P-433, WLS906-433, WLS907-433, WLS912-433,
WLS914-433 and WLS925L-433 devices in the places you want to mount them.
2. At a system keypad, enter [✱][8][Installer Code].
3. Enable the Global Module Placement test by entering section [804]. Then
enter sub-section [90] and turn on option [8].
4. Press [#] twice.
5. Enter programming section [904], then enter [01].
6. Activate one of the devices being tested until a result is displayed on the
keypad or sounded by the keypad or bell:
WLS904P-433/WLS914-433:
To perform a Placement Test on the WLS904P-
433, remove the detector from the back plate and then replace it. Once the
detector is replaced on the back plate the LED on the detector will flash
rapidly 5 times (4 times for the WLS914-433) to indicate that it has sent a
transmission. The panel will show and/or sound the result of the placement
test on the keypad. To perform a 2nd and 3rd test, repeat this procedure.
Carefully replace the backplate onto the detector, ensuring that “TOP” isCarefully replace the backplate onto the detector, ensuring that “TOP” is
Carefully replace the backplate onto the detector, ensuring that “TOP” isCarefully replace the backplate onto the detector, ensuring that “TOP” is
Carefully replace the backplate onto the detector, ensuring that “TOP” is
facing upward, or you may damage the tamper switch.facing upward, or you may damage the tamper switch.
facing upward, or you may damage the tamper switch.facing upward, or you may damage the tamper switch.
facing upward, or you may damage the tamper switch.
NOTE: When you remove the detector from the backplate (tamper the unit), the de-
tector will also be put into “Detector Walk Test” mode. While in Walk Test mode the
detector will activate the LED when motion is detected. The detector will also send a
signal to the receiver 5 seconds after motion is detected, indicated by 5 rapid flashes
by the LED. The LED will only work in this fashion for 10 motion detections after a
tamper/restore. Note that the panel will ignore these transmission signals with re-
spect to a placement test. The only way in which the panel will acknowledge a place-
ment test is if the backplate has, each time, been removed and restored.
WLS906-433: Remove the detector from its backplate, wait 5 seconds and re-
attach it, or hold a magnet near the raised line on the outer rim, then remove it.
WLS907-433/WLS925L-433: Open the contact by moving the magnet away
from the unit. The keypad will show/sound the test result. After the first test
result has been generated (about 10 seconds) close the contact to generate
another test result. If the unit is attached to a door or a window, open and
close the door or window to activate the device.

11
WLS909-433/WLS919-433: Press any function key at several different locations.
WLS912-433: Press and hold the test mode tab for 5 seconds. Release the test
mode tab. The keypad will display the test result.
Read the test results at the keypad:
Result LED Keypad LCD Keypad Buzzer/Bell
Good Light 1 On Steady “Good” 1 Beep/Squawk
Bad Light 3 On Steady “Bad” 3 Beeps/Squawks
Activate the device until you get 3 ‘good’ results in a row.
You may mount the WLS devices where results were good.
Devices indicating a bad result must be moved to another location. You may
only have to move the device a few inches to correct a bad result.
Do not mount any device where a “bad”test result was indicated.
7. Go to the next device to be tested and activate it until the test result is
displayed/sounded.
NOTE: Wait until the placement test of one device is shown/sounded before begin-
ning to test the next device.
Continue to test the devices until both the PC5132-433 and the devices are in good
locations. If several wireless devices produce ‘bad’ test results, you may need to
move the PC5132-433 to a better location. (See section 2.2 for tips on finding a
location for the PC5132.)
8. To exit the placement test and return to installer programming, press [#] twice.
Testing Individual WLS904P-433, WLS906-433, WLS907-433,
WLS912-433, WLS914-433 and WLS925L-433 Devices:
1. Temporarily place the WLS904P-433, WLS906-433 or WLS925L-433 where
you want to mount it.
2. At a system keypad, enter [✱][8][Installer Code].
3. Enter programming section [904].
4 Enter the 2-digit zone number for the device to be tested.
5. Activate the device being tested until a result is displayed on the keypad or
sounded by the keypad or bell. (Same as step 5 in the Global Placement Test
section, previous page.)
6. To test another device, press [#] once, then repeat steps 4 - 5. Continue to
test the devices until both the PC5132-433 and the devices are in good
locations.
If several wireless devices produce ‘bad’ test results, you may need to move
the PC5132-433 to a better location. (See section 2.2 for tips on finding a
location for the PC5132.)
7. To exit the placement test and installer programming, press [#] twice.
Testing Individual Wireless Keys:
You cannot use the individual device test described above to test WLS909-433/
WLS919-433 wireless keys. To ensure that the PC5132-433 receiver is receiving
transmissions from these devices, use the function keys on the WLS909-433/
WLS919-433 at several different points in the installation.
T E S T I N G & M O U N T I N G

12
5.2 Mount the PC5132-433 and Wireless Devices
When you have tested reception of the PC5132-433 with all the wireless devices (see
section 5.1) and you have a good mounting location, mount the PC5132:
1. Pull the Keybus wires through the hole at the bottom of the cabinet.
2. Mount the cabinet securely to the wall.
Mount the Devices
If you have conducted the placement test described in section 5.1 and got 3 ‘good’
results in a row for each device, you can mount the wireless devices. See the
Installation Sheet
for each device for mounting instructions.
Now that your PC5132-433 and wireless devices are mounted and working properly,
read section 6 for information on potential wireless trouble conditions, RF jamming
signals, and battery replacement.

13
Additional Notes
S E C T I O N 6
6.1 Trouble Conditions
The control panel always watches for possible trouble conditions. If a trouble
condition occurs, the keypad “Trouble” light will turn on and the keypad will beep.
Press [✱][2] to display the trouble conditions.
The following trouble conditions apply to the PC5132-433 and/or any enrolled devices.
General System Tamper - This trouble is generated when the PC5132-433
detects an RF Jamming condition.
General System Supervisory - This trouble will be generated if the panel loses
communication with any module connected to the Keybus. The event buffer will
log a detailed description of the event.
Device Low Battery - This trouble is generated when a wireless device exhibits a
low battery condition. Press [7] one, two, or three times to view which devices
are experiencing battery failure. An LED keypad will indicate battery failure
using zone lights 1 to 8.
Zone Tamper - This trouble is generated when an enrolled wireless device is
removed from its mounting location.
Zone Fault - Each wireless zone will send a supervisory signal every 64 minutes. If
the receiver does not receive a signal within the time programmed for the
Wireless Supervisory Window, it will generate a zone fault.
6.2 Jamming Signal Detection
The PC5132-433 receiver detects jamming signals that can prevent the receiver from
properly receiving transmissions from enrolled devices. See section 4.4 “Jamming
Signal Detection” for information on jamming signal detection programming.
6.3 Wireless Zone Low Battery Transmission
Within any transmission, the device will indicate the status of the battery. If a battery
is low, the system will indicate a Device Low Battery trouble.
The system will delay reporting the event to the central station for the number of days
programmed for Zone Low Battery Transmission Delay in section [370]. This will
prevent unnecessary reporting of the event if the user has been instructed on how
to replace batteries.
Replacing Batteries in Wireless Devices
1. Remove the cover of the device from its back plate. This creates a tamper
condition on the zone.
2. Refer to the battery installation instructions on the installation sheet of each
component. Be sure to note the proper orientation of the batteries as you install
them.
3. When the fresh batteries are in place, re-attach the cover to the back plate. The
tamper is restored and the zone sends a battery trouble restoral signal to the
PC5132. The battery trouble is now clear and the device should function normally.
NOTE: When batteries in one device need to be replaced, the batteries in all devices
may need to be replaced at the same time.

14
Troubles ooting
1. When I enter the 2-digit zone number when adding a wireless
device, the keypad gives me a long beep.
You cannot enter ESNs unless a PC5132-433 wireless receiver is connected to the
Keybus. See section 2 for instructions on setting up and wiring the PC5132-433
module.
2. I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
• Ensure the ESN has been entered correctly
• Ensure that the zone is enabled for the partition (if partition programming is
used).
• Ensure that the wireless zone is not assigned to a zone used by PC5108
modules, an on-board zone, or a keypad zone.
• Ensure that the zone is programmed for something other than “Null
Operation”, and that the wireless zone attribute is turned on.
3. When I try a module placement test I get no result or ‘bad’
results.
Check the following (see sections 5.1 and 5.2 for more information on testing
devices):
• Verify that you are testing the correct zone.
• Verify that the correct ESN was entered when the device was enrolled.
• Verify that the device is in range of the PC5132. Try testing the device in the
same room as the receiver.
• Confirm that the PC5132-433 is properly connected to the Keybus (see
section 2 for PC5132-433 set up and wiring instructions).
• Check that you are testing the zone correctly (see sections 5.1 and 5.2 for
testing instructions).
• Check that the batteries are working and installed correctly.
• Look for large metal objects that may be preventing the signal from reaching
the PC5132.
The device must be located where consistent ‘good’ results are obtained. If several
devices show ‘bad’ results, move the receiver. See section 2.2 for tips on choosing
a mounting location for the PC5132.
4. The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your
Wireless PIR Instruction Sheet
for
walk test instructions.
S E C T I O N 7

15
[804] 5132--433 Wireless Expansion Programming
• 6-digit entry is required. See Section 3.1 “A note on Electronic Serial
Numbers” for details on programming 6-digit serial numbers.
Zone Serial Numbers
Default = 000000
[01] Zone 1 l
_____l
_____l
_____l
_____l
_____l
_____l
[02] Zone 2 l
_____l
_____l
_____l
_____l
_____l
_____l
[03] Zone 3 l
_____l
_____l
_____l
_____l
_____l
_____l
[04] Zone 4 l
_____l
_____l
_____l
_____l
_____l
_____l
[05] Zone 5 l
_____l
_____l
_____l
_____l
_____l
_____l
[06] Zone 6 l
_____l
_____l
_____l
_____l
_____l
_____l
[07] Zone 7 l
_____l
_____l
_____l
_____l
_____l
_____l
[08] Zone 8 l
_____l
_____l
_____l
_____l
_____l
_____l
[09] Zone 9 l
_____l
_____l
_____l
_____l
_____l
_____l
[10] Zone 10 l
_____l
_____l
_____l
_____l
_____l
_____l
[11] Zone 11 l
_____l
_____l
_____l
_____l
_____l
_____l
[12] Zone 12 l
_____l
_____l
_____l
_____l
_____l
_____l
[13] Zone 13 l
_____l
_____l
_____l
_____l
_____l
_____l
[14] Zone 14 l
_____l
_____l
_____l
_____l
_____l
_____l
[15] Zone 15 l
_____l
_____l
_____l
_____l
_____l
_____l
[16] Zone 16 l
_____l
_____l
_____l
_____l
_____l
_____l
[17] Zone 17 l
_____l
_____l
_____l
_____l
_____l
_____l
[18] Zone 18 l
_____l
_____l
_____l
_____l
_____l
_____l
[19] Zone 19 l
_____l
_____l
_____l
_____l
_____l
_____l
[20] Zone 20 l
_____l
_____l
_____l
_____l
_____l
_____l
[21] Zone 21 l
_____l
_____l
_____l
_____l
_____l
_____l
[22] Zone 22 l
_____l
_____l
_____l
_____l
_____l
_____l
[23] Zone 23 l
_____l
_____l
_____l
_____l
_____l
_____l
[24] Zone 24 l
_____l
_____l
_____l
_____l
_____l
_____l
[25] Zone 25 l
_____l
_____l
_____l
_____l
_____l
_____l
[26] Zone 26 l
_____l
_____l
_____l
_____l
_____l
_____l
[27] Zone 27 l
_____l
_____l
_____l
_____l
_____l
_____l
[28] Zone 28 l
_____l
_____l
_____l
_____l
_____l
_____l
[29] Zone 29 l
_____l
_____l
_____l
_____l
_____l
_____l
[30] Zone 30 l
_____l
_____l
_____l
_____l
_____l
_____l
[31] Zone 31 l
_____l
_____l
_____l
_____l
_____l
_____l
[32] Zone 32 l
_____l
_____l
_____l
_____l
_____l
_____l
Programming Works eets
S E C T I O N 8

16
Wireless Key Serial Numbers
Default = 000000
[41] Key 01 l_____l_____l_____l_____l_____l_____l
[42] Key 02 l_____l_____l_____l_____l_____l_____l
[43] Key 03 l_____l_____l_____l_____l_____l_____l
[44] Key 04 l_____l_____l_____l_____l_____l_____l
[45] Key 05 l_____l_____l_____l_____l_____l_____l
[46] Key 05 l_____l_____l_____l_____l_____l_____l
[47] Key 07 l_____l_____l_____l_____l_____l_____l
[48] Key 08 l_____l_____l_____l_____l_____l_____l
P R O G R A M M I N G W O R K S H E E T S
[49] Key 09 l_____l_____l_____l_____l_____l_____l
[50] Key 10 l_____l_____l_____l_____l_____l_____l
[51] Key 11 l_____l_____l_____l_____l_____l_____l
[52] Key 12 l_____l_____l_____l_____l_____l_____l
[53] Key 13 l_____l_____l_____l_____l_____l_____l
[54] Key 14 l_____l_____l_____l_____l_____l_____l
[55] Key 15 l_____l_____l_____l_____l_____l_____l
[56] Key 16 l_____l_____l_____l_____l_____l_____l
Wireless Key Function Key Options
yrtnEyrtnE yrtnE yrtnEyrtnEnoitpircseDyeKnoitpircseDyeK noitpircseDyeK noitpircseDyeKnoitpircseDyeKyrtnEyrtnE yrtnE yrtnEyrtnEnoitpircseDyeKnoitpircseDyeK noitpircseDyeK noitpircseDyeKnoitpircseDyeK
0000000000yeKlluN 6161616161[✱tixEkciuQ]0[]
20-1020-10 20-10 20-1020-10 esUerutuFroF 7171717171[✱syawA/yatSetavitcaeR]1[]
3030303030mrAyatS 8181818181esUerutuFroF
4040404040mrAyawA 9191919191[✱3#tuptuOdnammoC]3[]7[]
5050505050[✱mrAyrtnE-oN]9[] 0202020202esUerutuFroF
6060606060[✱FFO/NOemihC]4[] 1212121212[✱4#tuptuOdnammoC]4[]7[]
7070707070[✱tseTmetsyS]4[]---[]6[] 62-2262-22 62-22 62-2262-22 esUerutuFroF
21-8021-80 21-80 21-8021-80 esUerutuFroF7272727272)FFO(mrasiD
3131313131[✱1#tuptuOdnammoC]1[]7[]8282828282esUerutuFroF
4141414141esUerutuFroF9292929292mralAyrailixuA
5151515151esUerutuFroF 0303030303mralAcinaP
Table of contents
Other DSC Security System manuals