Please read the following before installing
your Surge Protective Device:
DEUTSCH
Bitte lesen Sie die folgenden Angaben vor
Installation des Überspannungsschutzgeräts:
FRANÇAIS
Veuillez lire les instructions suivantes avant
d’installer votre parafoudre:
ESPAÑOL
Lea las siguientes instrucciones antes de la
instalación de su dispositivo de protección
contra sobretensiones:
ITALIANO
Prima di installare il limitatore di sovratensione
(SPD: Surge Protective Device), leggere attenta-
mente quanto segue:
• Verify the system voltage and congu-
ration on the label is appropriate for the
application.
• Risk of Electric Shock – Installation
and maintenance should be performed
by qualied personnel only.
• Safety rules and regulations applicable
to all devices connected to power lines
should always be followed. National
standards and safety regulations must
be followed.
• The external mechanical integrity of
the device must be checked before in-
stallation. Products with visible damage
should not be installed.
• Its use is only permitted within the
limits shown and stated in these
installation instructions. Opening or
tampering with the device invalidates
the warranty.
• It is very important to ensure the new
device is of the same type and voltage
as that being replaced.
• Sicherstellen, dass die Systemspannung
und -konguration auf dem Etikett für die
Anwendung geeignet ist.
• Stromschlaggefahr – Installation und
Wartung sollten nur vom Fachmann
durchgeführt werden.
• Die Sicherheitsvorschriften und -regeln für
alle an Stromleitungen angeschlossenen
Geräte sind stets zu befolgen. Vor Ort gel-
tende Normen und Sicherheitsvorschriften
beachten.
• Vor der Installation ist die externe
mechanische Unversehrtheit des Geräts
sicherzustellen. Produkte mit sichtbaren
Schäden dürfen nicht installiert werden.
• Das Gerät ist nur für den Betrieb innerhalb
der angegebenen Grenzwerte zugelassen.
Wird das Gerät geöffnet oder manipuliert,
erlischt die Garantie.
• Das neue Gerät muss vom selben Typ
sein und dieselbe Betriebsspannung auf-
weisen wie das Gerät, das ersetzt wird.
• Vériez la tension et la conguration du
système sur l’étiquette pour déterminer son
adéquation à l’application.
• Risque de choc électrique – l’installation et la
maintenance doivent être effectuées par un
personnel qualié uniquement.
• Il est impératif de toujours respecter les règles
et consignes de sécurité applicables à tous
les appareils branchés à des lignes électri-
ques. Les normes et les règles de sécurité
nationales doivent être également respectées.
• L’intégrité mécanique externe de l’appareil doit
être vériée avant l’installation. Tout produit
présentant des dommages visibles ne doit
pas être installé.
• Son utilisation n’est autorisée que conformé-
ment aux limites indiquées et spéciées dans
les présentes instructions d’installation. Toute
ouverture ou altération de l’appareil invalide
la garantie.
• Il est très important de veiller à ce que le
nouvel appareil soit du même type et présente
la même tension que celui à remplacer.
• Compruebe si la tensión y conguración
del sistema que aparecen en la etiqueta
son las adecuadas para la aplicación.
• Riesgo de descarga eléctrica: solo per-
sonal cualicado debe hacer la instalación
y el mantenimiento.
• Respete siempre las reglas y normas de
seguridad correspondientes a todos los
dispositivos conectados a la red eléctrica.
Respete los estándares nacionales y las
reglas de seguridad.
• Compruebe la integridad mecánica exter-
na del dispositivo antes de la instalación.
No deben instalarse productos con daños
visibles.
• Su uso solo está permitido si se hace
dentro de los límites que se muestran e
indican en estas instrucciones de insta-
lación. Abrir o alterar el dispositivo anula
la garantía.
• Es muy importante asegurarse de que
el dispositivo nuevo sea del mismo tipo y
tensión que el que se reemplaza.
• Vericare la tensione di sistema e la con-
gurazione sull’etichetta se appropriato per
l’applicazione.
• Rischio di scosse elettriche - l’installazione
e la manutenzione devono essere eseguite
solo da personale qualicato.
• Rispettare sempre le norme e i regolamenti
di sicurezza applicabili a tutti i dispositivi
collegati alle linee elettriche. Rispettare i reg-
olamenti e le norme di sicurezza nazionali.
• L’integrità meccanica esterna del dispositivo
deve essere vericata prima dell’installazi-
one. I prodotti con danni visibili non devono
essere installati.
• L’utilizzo è consentito solo nei limiti indicati
nelle presenti istruzioni per l’installazione.
L’apertura o la manomissione dell’apparec-
chio fa decadere la garanzia.
• È molto importante assicurarsi che il nuovo
dispositivo sia dello stesso tipo e tensione di
quello che si sta sostituendo.
Installation Instructions
Installationsanleitung
Manuel d’installation
Istruzioni per l’installazione
Instrucciones de Instalación

AG II IT DN0xx Series
Eaton Corporation, 1000 Eaton Boulevard, Cleveland, OH 44122, United States
© 2022 by Eaton, www.eaton.com
03.2022a / All Rights Reserved
For more information, please contact the EatonTechnical Resource Center
at 1-800-809-2772, option 4, option 2.You may submit inquiries via email to
[email protected] and you can find more information at eaton.com/aegis.
Electrical specication AG II IT DN012 AG II IT DN024
Lines Protected 2 (4 Conductors)
Nominal Operating Voltage (DC) [Un]12 V 24 V
Maximum Continuous Operating Voltage (DC) [Uc]15 V 28 V
Rated Load Current at 25ºC [IL]1 A
C2 Nominal Discharge Current (8/20 µs) [In]10 kA
Maximum Discharge Current (8/20 μs) [Imax]20 kA
D1 Impulse Current (10/350 µs) [Iimp]5 kA
Rated Spark Overvoltage (Line-Ground) 16-21 V 31-37 V
(Line-Line) 16-21 V 31-37 V
Serial Resistance per Path [R] 1.6-2.0 Ω
Cut-o Frequency [fG]30 MHz
Mechanical specication
Temperature Range [Ta] -40°C...+80°C
Warranty 1 year
INTERNAL CONFIGURATION
INSTALL. CROSS SECTION / PRODUCT VERSIONS
TECHNICAL DATA
CONNECTION
CORRECT CABLE ROUTING
WRONG CABLE ROUTING
MODULE REPLACEMENT
10mm 10mm
line ø max 4 mm24 mm2
zø min 6 mm26 mm2
Screw Terminals
Fixing on DIN Rail
IN
OUT
20 10
[mm]
10
[mm]
IN
OUT
0.8 x 4
0.5 Nm
0.6 x 3.5
0.5Nm
min. 6mm2
1. Step: Press
2. Step
Pull down
3. Step: Press
4. Step:
Pull up
5. Step:
Pull out
1. Step: Press
2. Step
Pull down
3. Step: Press
4. Step:
Pull up
5. Step:
Pull out
1
3
2
4
5
7
6
8

This manual suits for next models

2

Other Eaton Circuit Breaker manuals

Eaton Power Defense 32-NF Manual

Eaton

Eaton Power Defense 32-NF Manual

Eaton 50 DHP User manual

Eaton

Eaton 50 DHP User manual

Eaton 520 Manual

Eaton

Eaton 520 Manual

Eaton DIL-11-PI Series Manual

Eaton

Eaton DIL-11-PI Series Manual

Eaton Power Defense PD3 Operating and safety instructions

Eaton

Eaton Power Defense PD3 Operating and safety instructions

Eaton QSA200N Series Manual

Eaton

Eaton QSA200N Series Manual

Eaton NZM1-XKP Manual

Eaton

Eaton NZM1-XKP Manual

Eaton XTCC012C Series Manual

Eaton

Eaton XTCC012C Series Manual

Eaton PBSM Manual

Eaton

Eaton PBSM Manual

Eaton PKE65/AK/XTU-65-SP User manual

Eaton

Eaton PKE65/AK/XTU-65-SP User manual

Eaton PKZM0 PI Series Manual

Eaton

Eaton PKZM0 PI Series Manual

Eaton PKE32/XTU-36-SOND533 Manual

Eaton

Eaton PKE32/XTU-36-SOND533 Manual

Eaton RMQ-Titan M22-XLED Series Manual

Eaton

Eaton RMQ-Titan M22-XLED Series Manual

Eaton SPBT12-280 NPE50 Series Manual

Eaton

Eaton SPBT12-280 NPE50 Series Manual

Eaton Magnum PXR User manual

Eaton

Eaton Magnum PXR User manual

Eaton DDC-125/2 Manual

Eaton

Eaton DDC-125/2 Manual

Eaton Ulusoy URING12-24-LLC-SF6 User manual

Eaton

Eaton Ulusoy URING12-24-LLC-SF6 User manual

Eaton Digitrip RMS Series Manual

Eaton

Eaton Digitrip RMS Series Manual

Eaton MSC-D XTSE Series Manual

Eaton

Eaton MSC-D XTSE Series Manual

Eaton UL1066 Magnum Manual

Eaton

Eaton UL1066 Magnum Manual

Eaton BZM3 SIMPLE Manual

Eaton

Eaton BZM3 SIMPLE Manual

Eaton Cutler-Hammer DSII Series Programming manual

Eaton

Eaton Cutler-Hammer DSII Series Programming manual

Eaton PKZM0-0,16 User manual

Eaton

Eaton PKZM0-0,16 User manual

Eaton MSFANZM1-125A Manual

Eaton

Eaton MSFANZM1-125A Manual

Popular Circuit Breaker manuals by other brands

hager K14 Series Assembly instructions

hager

hager K14 Series Assembly instructions

Siemens 3VA20 JP Series operating instructions

Siemens

Siemens 3VA20 JP Series operating instructions

ABB AKD-5 installation manual

ABB

ABB AKD-5 installation manual

Siemens 3RV1.2 operating instructions

Siemens

Siemens 3RV1.2 operating instructions

MAXGE MGB Series manual

MAXGE

MAXGE MGB Series manual

Larsen & Toubro U-POWER Omega UW-MTX1.0 user manual

Larsen & Toubro

Larsen & Toubro U-POWER Omega UW-MTX1.0 user manual

LEGRAND Pass & Seymour 1594-CMA Installation and operating instructions

LEGRAND

LEGRAND Pass & Seymour 1594-CMA Installation and operating instructions

Allen-Bradley 140G Series Installation

Allen-Bradley

Allen-Bradley 140G Series Installation

Siemens 3AH35-MA instruction manual

Siemens

Siemens 3AH35-MA instruction manual

FEDERAL PIONEER H-3 INSTRUCTIONS FOR THE CARE AND MAINTENANCE

FEDERAL PIONEER

FEDERAL PIONEER H-3 INSTRUCTIONS FOR THE CARE AND MAINTENANCE

CBS ArcSafe RSA-102 Installation and operation

CBS ArcSafe

CBS ArcSafe RSA-102 Installation and operation

Siemens SIRIUS 3RV1.4 operating instructions

Siemens

Siemens SIRIUS 3RV1.4 operating instructions

Bticino Btdin B6338D instruction sheet

Bticino

Bticino Btdin B6338D instruction sheet

IEK BA88-32 instructions

IEK

IEK BA88-32 instructions

hager XEVS400 Replacement manual

hager

hager XEVS400 Replacement manual

LEGRAND DPX3 630 manual

LEGRAND

LEGRAND DPX3 630 manual

Leviton LSPD1 installation instructions

Leviton

Leviton LSPD1 installation instructions

hager hw+ user manual

hager

hager hw+ user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.