SPECIFICATIONS
Bain Marie meal distribution units have been designed to maintain food
at a predetermined, thermostat-adjusted temperature.
• Temperature range between +30ºC and +90ºC.
• Deep-drawn Bain Marie well with rounded corners.
• Well with capacity for 3 200mm-deep Gastronorm 1/1 pans in the 311 models
and 4 200mm-deep 1/1 pans in the 411 models.
• Gastronorm pans are not included.
• On top, Bain Marie with water.
• The temperature of the Bain Marie is thermostat-controlled. In models fitted with
a cupboard, the temperature of the Bain Marie and the cupboard is regulated
separately with two different thermostats.
• In models fitted with a cupboard, this is heated with forced air.
• Equipped with an analogue thermometer.
• Unit “on” indicator pilot light.
• Taps included for water inlet and drainage.
• Sturdy legs with height-adjustable feet.
• Sliding doors.
• Double-wall doors with ecological polyurethane insulation with a density of 40
kg.
• Interior and exterior in 18/10 stainless steel.
• Important: The well must be filled with water before the Bain Marie is
Switched-on.
MBM-311, SBM-311
Resistencias: 3 de 700W
Consumo: 9.5A
MBMR-311, SBMR-311
Resistencias (cuba): 3 de 700W
Resistencias (reserva): 1 de 1400W
Consumo: 16A
MBM-411, SBM-411
Resistencias: 3 de 700W
Consumo: 9.5A
MBMR-411, SBMR-411
Resistencias (cuba): 3 de 700W
Resistencias (reserva): 1 de 1400W
Consumo: 15.9A
•Installation
•
•Place the unit on a flat surface and make sure that it is correctly levelled.
•Connect the unit to the mains power supply (230V II 50 – 60 Hz or 230V and
400V III 50 – 60 Hz according to model). 411 models leave the factory ready for
operating at 400V. Should it be necessary to convert it to 230V, a bag with all the
elements required to make the conversion is included.
• The unit must be correctly earthed
(See diagrams)