EL-100U3P
Art.-Nr.: 0 4600 01XXEV10-00
Art.-Nr.: 0 4601 01XXEV10-00
eks Engel FOS GmbH & Co. KG
Schützenstraße 2-4
57482 Wenden-Hillmicke
Germany
Tel: +49 (0) 2762 9313-600
Fax: +49 (0) 2762 9313-7906
E-Mail: [email protected]
Internet: www.eks-engel.de
Rechtliche Hinweise
Legal Notice
Diese Anleitung enthält wichtige Anmerkungen und Warnungen, deren Nichtbe-
achtung zu ernsthaften Personen- oder Anlageschäden führen kann. Bitte lesen
Sie die Anleitung vor Inbetriebnahme der EL-100U3P Geräte aufmerksam durch.
Ordnungsgemäßer Transport, korrekte Lagerung und Installation sowie sorgfältige
Bedienung und Instandhaltung der EL-100U3P sind entscheidend für den sicher-
en Betrieb.
This manual contains important notes and warnings. Their ignoration can cause
serious injuries or damages to the system. Please read the manual carefully
before using the equipment EL-100U3P. Correct transport, proper storage and
installation as well as careful operation and maintenance of EL-100U3P are
critical for safe operation.
Bedienungsanleitung
Manual
MAN_EL-100U3P
Version:
3.81
/ 08.02.2018
Freigabe:
M.H.
Seite 2 von 4
Systembeschreibung
System description
Die Medienkonverter der Serie EL-100U3P mit PoE-Funktionalität haben eine
ultrakompakte Bauform mit den Abmaßen von 22,5 x 95 x 80 mm. Sie zeichnen sich
durch einfache Funktionalität und Bedienfreundlichkeit wie Auto-Negotiation und Auto
MDI/MDI-X aus sowie einem erweiterten Temperaturbereich aus.
Das flache Design des Gehäuses bietet größtmögliche Flexibilität und Sicherheit bei
allen Anwendungen im Innen- und Außenbereich. Eingesetzt werden kann der EL-
100U3P überall dort, wo enge Platzverhältnisse herrschen, wie z.B. in Kleinverteiler-
gehäusen. In Verbindung mit den anderen Systemen der Baureihe e-light lassen sich
somit individuelle Applikationen realisieren.
Als optische Anschlussvariante stehen neben ST, SC und E-2000® zur Verfügung. Alle
Systeme können sowohl über zwei Fasern als auch über eine Faser durch BIDI-Technik
mit SC- oder ST-Anschluss kommunizieren. Für den Kunststoff-LWL (POF) gibt es auch
eine crimp- und steckerlose Variante mit Klemmverriegelung.
In der Standardversion funktioniert der EL-100U3P im Modus Converter Mode, wenn
alle Ports auf 100MBit/s arbeiten, ansonsten arbeitet das System in einem Cut-Through-
Modus. Auf Wunsch kann das System auch mit dem Modus Store & Forward angeboten
werden.
Das Gerät unterstützt zudem Link Fault Pass-Through (LFP). Durch diese Funktion wird
bei einem Fehler auf der LWL-Seite die Kupferseite abgeschaltet und umgekehrt bei
einem Fehler auf der Kupferseite die LWL-Seite abgeschaltet. Somit wird der Ausfall
einer Verbindung auch an den Endpunkten signalisiert.
The EL-100U3P PoE media converters have an extra small housing with a dimension of
22,5 x 95 x 80 mm. Its features are Auto-Negotiation and Auto MDI/MDI-X as well as an
extended temperature range.
The flat design of the housing offers an extremely high degree of flexibility for all kinds of
indoor and outdoor applications. EL-100U3P is suitable wherever there is little space,
e.g. in small distribution boxes. In combination with other systems out of the e-light
series, individual applications can be realized.
Besides ST, SC and E-2000® are also available as connector options. All systems can
communicate via two or one fiber with the help of BIDI-technology with SC-port.
The EL-100U3P standard mode is Converter Mode, if all ports work with 100mbps.
Otherwise the mode is Cut-Trough. Optionally, the device is also available with Store
and Forward Mode.
Furthermore, the device supports Link Fault Pass-Through (LFP). This function makes
the copper side switch off in case of a failure at the fiber optic side and vice versa. Thus,
a breakdown at the terminals is signaled as well.
Anschlusshinweise
Hardware Installation
Achtung: Beim Betrieb elektrischer Betriebsmittel und Anlagen stehen zwangsläufig
bestimmte Teile unter gefährlicher Spannung. Arbeiten an elektrischen Anlagen oder
Betriebsmitteln dürfen nur von einer Elektrofachkraft oder von unterwiesenen
Personen unter Anleitung und Aufsicht einer Elektrofachkraft, den elektrotechnischen
Regeln entsprechend, vorgenommen werden.
Schalten Sie die Systeme und Endgeräte spannungsfrei.
Rasten Sie das Gerät auf eine Tragschiene DIN EN auf, oder nutzen Sie die
Wandhalterung. Überprüfen Sie den sicheren Halt!
Achtung: Benutzen Sie nur die passenden LWL-Anschlussstecker. Wir weisen
ausdrücklich darauf hin, dass der Anschluss mit falschen Steckverbindern Schäden
an den optischen Anschlüssen hervorrufen kann! Beachten Sie zudem, dass die Ste-
cker, die eine Verriegelung besitzen, nur in einer definierten Position montiert werden
können.
Achtung: Sehen Sie nicht in den optischen Sender! Das gebündelte und abhängig
von der Wellenlänge sichtbare oder unsichtbare Licht kann zu Augenschäden führen!
Verbinden Sie den ankommenden Lichtwellenleiter mit dem optischen Empfänger und
den abgehenden Leiter mit dem optischen Sender des LWL-Systems.
Benutzen Sie die beigefügten Stopfen, um Sender und Empfänger des LWL-Systems
im nicht eingebauten oder nicht benutzten Zustand vor Verunreinigungen und Staub
zu schützen.
Achtung: Knicken Sie das LWL-Kabel nicht zu stark und beachten Sie den Biegeradius
des Kabels. Andernfalls kann das Kabel beschädigt und/oder die Kommunikation
zwischen den LWL-Wandlern nicht mehr gewährleistet werden.
Schalten Sie die Betriebsspannung für die LWL-Systeme ein. Zur Versorgung der
Systeme wird eine Betriebsspannung von 44 - 57 VDC PoE / 50 - 57 VDC PoE+
benötigt,die an die Klemmen +UB und GND angelegt wird. Das System hat einen
Verpolungsschutz.
Achtung bei Systemen mit BIDI: Bei Verwendung von Systemen mit optischem BIDI-
Anschluss müssen immer die optischen Anschlüsse (Transceiver) vom Typ A mit
Typ B verbunden werden.
Status-LEDs: RJ45 (gelb): leuchtet, wenn beide Ports verbunden sind,
blinkt bei Datenverkehr auf dem Port.
RJ45 (grün): leuchtet bei Vollduplex-Betrieb, blinkt bei
Kollisionen.
Fiber Optic (gelb): leuchtet, wenn beide Ports verbunden sind,
blinkt bei Datenverkehr auf dem Port.
Fiber Optic (rot): leuchtet, wenn ein gültiges PD (powered device)
angeschlossen ist und versorgt wird. In Fehler-
fällen blinkt die LED zweimal für Überstrom oder
fünfmal bei Anschluss eines falschen Signatur-
widerstandes.
POF-Verbindung:
Um das POF-Kabel mit dem Optolock zu verbinden, wird das Kabel zunächst sauber
abgeschnitten. Mit dem POF-Schneidwerkzeug wird das Kabel an der gewünschten
Stelle mit einem geraden Schnitt im 90°-Winkel getrennt. Die Enden der beiden Fasern
werden anschließend separiert. Jede Faser wird dann in eines der beiden Löcher des
Transceiver Gehäuses eingeführt und der Verschluss wird zusammengepresst, um die
POF-Faser in Position zu halten.
Beachten Sie bei der Verarbeitung von Lichtwellenleitern deren Biegeradius und den
Temperaturbereich der eingesetzten Stecker.
HINWEIS: Ein Dokument mit weiteren Hinweisen zur Verarbeitung von POF-Kabeln
und Transceivern finden Sie unter www.eks-engel.de/unternehmen/downloads.
Attention: During operation of electrical equipment and systems, parts carry
dangerous voltages. Work on the electrical systems or equipment is only
allowed by a skilled electrician himself or by specially instructed persons under
the control and instructions of a qualified electrician and the compliance of the
electro technical regulations.
Power off the devices during the installation.
Snap the system onto the DIN EN rail. Check the correct holding!
Attention: Only use the correct optical connectors for the fiber optic system. Using
incorrect connectors can cause damage to the fiber optic system. Take care that
connectors with a latch can only be mounted in a defined position.
Attention: Don't stare into the optical cable or the transmitter of the fiber optic system.
Visible and nonvisible light (depending on the wavelength) of the optical transmitter
can cause eye-damages!
Connect the fiber optic system by using the correct fiber optic cable. Take care that you
always have to connect an optical transmitter with an optical receiver.
Use the plugs to save the unused optical receiver and transmitter against impurity.
Attention: Don't bend the fiber optic cable! Please refer to the manufacturer’s
specifications. Otherwise the fiber optic cable can be damaged and/or the
communication will be lost.
Power on the devices. Please use a power supply of 44 - 57 VDC PoE / 50-57 VDC
PoE+, connected to the terminals marked with +UB and GND. Note, that +UB has a
reverse voltage protection.
Attention: BIDI Switches must always be connected from transceiver type A to a
transceiver type B.
Status-LEDs: RJ45 (yellow):lights when both ports are connected,
flashes during data transfer.
RJ45 (green):lights at full duplex mode, flashes during
collisions.
Fiber Optic (yellow):lights when both ports are connected,
flashes during data transfer.
Fiber Optic (red): lights when the port is connected to a valid
PD and feeds this device. A series of two
flashes indicates an overcurrent fault
occurred during port power-on. A series of
five flashes indicates that during detection
an invalid low or high discovery signature
resistance was detected.
POF-connection:
To connect the POF cable with the Optolock, the end of the cable has to be cut. Use a
POF-Cutter to make a straight cut in an angle of 90° at the required position of the cable.
After that separate the end of the cable into two strands. Then the strands are inserted
into the two holes in the termination housing, which is then clamped to hold the POF in
position.
Pay attention on the bending radius of the optical cables while installing them and check
the temperature range of the used plugs.
PLEASE NOTE: You can find a document with remarks concerning the handling of
POF-Cable and Transceiver on www.eks-engel.de/unternehmen/downloads.
Bedienungsanleitung
Manual
MAN_EL-100U3P
Version:
3.81
/ 08.02.2018
Freigabe:
M.H.
Seite 3 von 4
Anschlussbilder / Schematics
Systembeschreibung mit BIDI / System Description with BIDI
Bei Verwendung von Systemen mit optischem BIDI-Anschluss
müssen immer die optischen Anschlüsse (Transceiver) vom Typ
A mit Typ B verbunden werden.
BIDI-Systems always have to be connected from transceiver
type A to a transceiver type B.
Entsorgungshinweis
Disposal notes
Die Geräte der EL-100U3P Produktfamilie dürfen nicht über den normalen
Hausmüll entsorgt werden, sondern können bei eks Engel FOS GmbH & Co. KG
entsorgt werden.
The units of EL-100U3P family must not be disposed with normal household
waste but can be returned to eks Engel FOS GmbH & Co. KG for disposal.
Bedienungsanleitung
Manual
MAN_EL-100U3P
Version:
3.81
/ 08.02.2018
Freigabe:
M.H.
Seite 4 von 4
Typenauswahl und Technische Daten
Type Selection and Technical Data
POF
EL100U3P-1TX-1FX-PO-ST
EL100U3P-1TX-1FX-PO-CL
Order-No. (Data Pair / Var A)
046000101EV10-00
046000103EV10-00
Order-No. (Spare Pair / Var B)
046010101EV10-00
046010103EV10-00
100 FX Ports
1 x ST
1 x CLAMP
Fiber
Kunststoff-Lichtwellenleiter / POF
Fiber Type
980/1000 µm
Wavelength
650 nm
Budget
12 dB
Distance
40 m (180 dB/km)
HCS/PCF
EL100U3P-1TX-1FX-HC-ST
EL100U3P-1TX-1FX-HC-SC
EL100U3P-1TX-1FX-HC-E2
Order-No. (Data Pair / Var A)
046000111EV10-00
046000113EV10-00
046000115EV10-00
Order-No. (Spare Pair / Var B)
046010111EV10-00
046010113 EV10-00
046010115EV10-00
100 FX Ports
1 x ST
1 x SC
1 x E2000
Fiber
HCS / PCF
Fiber Type
200/230 µm
Wavelength
850 nm
Budget
12 dB
Distance
200 m (8 dB/km)
Multimode
EL100U3P-1TX-1FX-MM-ST
EL100U3P-1TX-1FX-MM-SC
EL100U3P-1TX-1FX-MM-SC-BIDIA
EL100U3P-1TX-1FX-MM-SC-BIDIB
EL100U3P-1TX-1FX-MM-E2
Order-No. (Data Pair / Var A)
046000131EV10-00
046000133EV10-00
046000136EV10-00
046000137EV10-00
046000135EV10-00
Order-No. (Spare Pair / Var B)
046010131 EV10-00
046010133 EV10-00
046010136 EV10-00
046010137 EV10-00
046010135 EV10-00
100 FX Ports
1 x ST
1 x SC
1 x SC
1 x E2000
Fiber
Multimode
Fiber Type
50(62,5)/125 µm
62,5/125µm
Wavelength
1300 nm / BiDi: 1300 nm + 1510 nm
Budget
12 (15) dB
Distance
5000 m (4000 m), (1 dB/km)
Singlemode
EL100U3P-1TX-1FX-SM-ST
EL100U3P-1TX-1FX-SM-SC
EL100U3P-1TX-1FX-SM-SC-BIDIA
EL100U3P-1TX-1FX-SM-SC-BIDIB
EL100U3P-1TX-1FX-SM-E2
Order-No. (Data Pair / Var A)
046000151EV10-00
046000153EV10-00
046000156EV10-00
046000157EV10-00
046000155EV10-00
Order-No. (Spare Pair / Var B)
046010151 EV10-00
046010153 EV10-00
046010156 EV10-00
046010157 EV10-00
046010155 EV10-00
100 FX Ports
1 x ST
1 x SC
1 x SC
1 x E2000
Fiber
Singlemode
Fiber Type
9/125 µm
Wavelength
1310 nm / BiDi: 1310 nm + 1510 nm
Budget
16 dB
Distance
15 km (andere Reichweiten auf Anfrage / please request for other distances) (0,3 dB/km)
TX-Port
TX-Port
RJ45 / Auto-Negotiation / Auto MDI/MDI-X / unterstützt Längen bis 100 m [Cat 6]
RJ45 / Auto-Negotiation / Auto MDI/MDI-X / supports length up to 100 m [Cat 6]
Versorgungsspannung
Operating voltage
PoE: 44 - 57 VDC / PoE+: 50 - 57 VDC
PoE 44 - 57 VDC / PoE+: 50 - 57 VDC
PoE Leistung
PoE Power
PoE: 15,4 W (IEEE 802.3af) / PoE+: bis zu 30 W (IEEE 802.3at)
PoE: 15.4 W (IEEE 802.3af) / PoE+: up to 30 W (IEEE 802.3at)
Abmessungen / Gewicht
Dimensions / Weight
B: 22,5 mm, H: 95 mm, T: 80 mm / 150 g
W: 22,5 mm, H: 95mm, D: 80 mm / 150 g
Gehäuse / Schutzart
Case / Protection class
Polyamid Schwarz / IP20
Polyamide black / IP20
Betriebstemperatur
Operating temperature
-10 °C bis +60 °C
-10 °C to +60 °C
Luftfeuchtigkeit
Humidity
5-95% rHd nicht kondensierend
5-95% rHd not-condensing
Elektromagnetische Verträglichkeit
Electromagnetic compatibility
EN61000-6-2 / EN55032 Klasse B +A1 +A2
EN61000-6-2 / EN55032 Class B +A1 +A2
Technische Änderungen vorbehalten. Für Irrtümer und Druckfehler keine Haftung. © eks Engel FOS GmbH & Co. KG
Reserve technical changes. No liability is accepted for errors and printing errors. © eks Engel FOS GmbH & Co. KG

This manual suits for next models

44

Other eks Media Converter manuals

eks IOL-3200 User manual

eks

eks IOL-3200 User manual

eks EL-100U3 User manual

eks

eks EL-100U3 User manual

eks EL-100-3P User manual

eks

eks EL-100-3P User manual

eks IOL-3000 User manual

eks

eks IOL-3000 User manual

eks EL-100-3 User manual

eks

eks EL-100-3 User manual

eks DL-LWV User manual

eks

eks DL-LWV User manual

eks d-light DL-232R Operating and installation instructions

eks

eks d-light DL-232R Operating and installation instructions

eks EL-1000-3G User manual

eks

eks EL-1000-3G User manual

eks EL-100XS User manual

eks

eks EL-100XS User manual

eks e-light EL100-S Series User manual

eks

eks e-light EL100-S Series User manual

eks DL-422 User manual

eks

eks DL-422 User manual

eks DL-CAN FV User manual

eks

eks DL-CAN FV User manual

eks IOL-3100 User manual

eks

eks IOL-3100 User manual

eks pe-light-1 User manual

eks

eks pe-light-1 User manual

eks EL-1000-XSG-SFP User manual

eks

eks EL-1000-XSG-SFP User manual

eks EL-1000-XSG User manual

eks

eks EL-1000-XSG User manual

eks e-light U3 Operating and installation instructions

eks

eks e-light U3 Operating and installation instructions

eks Inroi d-light DL-LWV Operating and installation instructions

eks

eks Inroi d-light DL-LWV Operating and installation instructions

eks inroi DL-422 User manual

eks

eks inroi DL-422 User manual

eks DL-LWV User manual

eks

eks DL-LWV User manual

eks EL1000-3G User manual

eks

eks EL1000-3G User manual

Popular Media Converter manuals by other brands

VSSL A.3 Product guide

VSSL

VSSL A.3 Product guide

KT-Elektronik ModBus-MBus-Gateway Installation and operating manual

KT-Elektronik

KT-Elektronik ModBus-MBus-Gateway Installation and operating manual

Philips WAK3300/05 quick start guide

Philips

Philips WAK3300/05 quick start guide

K & K Audio Extreme RAKK Mark III Assembly manual

K & K Audio

K & K Audio Extreme RAKK Mark III Assembly manual

Vitec Multimedia MGW Ace Decoder OG user manual

Vitec Multimedia

Vitec Multimedia MGW Ace Decoder OG user manual

Converters.TV 499 Operation manual

Converters.TV

Converters.TV 499 Operation manual

Atlona AT-3GSDI-HD user manual

Atlona

Atlona AT-3GSDI-HD user manual

Patton electronics 2065RC user manual

Patton electronics

Patton electronics 2065RC user manual

Connecticut Electric PARALLAX POWER SUPPLY PARAMODE 5400 Series Operator's guide

Connecticut Electric

Connecticut Electric PARALLAX POWER SUPPLY PARAMODE 5400 Series Operator's guide

AMX NMX-ENC-N1122 instruction manual

AMX

AMX NMX-ENC-N1122 instruction manual

LDT Digital Professional Series operation instruction

LDT

LDT Digital Professional Series operation instruction

Panduit Atlona OmniStream AT-OMNI-512 manual

Panduit

Panduit Atlona OmniStream AT-OMNI-512 manual

Behringer Ultramatch Pro SRC2496 user manual

Behringer

Behringer Ultramatch Pro SRC2496 user manual

TRENDnet TFC-1000MGA datasheet

TRENDnet

TRENDnet TFC-1000MGA datasheet

Blackmagic 2110 IP Converter 3x3G Installation and operation manual

Blackmagic

Blackmagic 2110 IP Converter 3x3G Installation and operation manual

PROception PRODVC11 quick start guide

PROception

PROception PRODVC11 quick start guide

urmet domus 2 VOICE 1083/80 manual

urmet domus

urmet domus 2 VOICE 1083/80 manual

Avantree OTHR-HAX04 quick start guide

Avantree

Avantree OTHR-HAX04 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.