Technical Support Line +44 (0)23 9269 6638 (Option 3) G1380xB -y-s PAK200569_01C June 2016 © 2016 Elmdene International Ltd
13.8V
DC
S
WITCH
M
ODE
P
OWER
S
UPPLIES
W
ITH
B
ATTERY
ONITORING AND
R
E OTE
F
AULT
S
IGNALLING
Models:
G1380xBM- -y / G1380xBMU
Where ‘x’ is max load current: 1A or 2A, ‘n’ is number of
fused outputs, and ‘y’ is Enclosure type A, B, C, or R
F
EATURES
High efficiency cost effective power supply range ideal for use in Intruder, Access Control and General
Security applications. Featuring a regulated 13.8V dc output supplying continuous full rated current to load
and a universal mains voltage input. aximum battery life is assured using deep discharge protection to
prevent premature battery failure when operating in standby mode for extended periods. Two sets of volt
free contacts are provided to signal (i) loss of mains and (ii) battery and loss of output faults.
•Continuous full rated current to load
•Universal mains input voltage 90-264V ac
•High efficiency electronics for reduced
running costs and lower operating
temperatures
•Installer safe design with all high voltage
electronics fully shrouded
•ains transient protection circuit
•Lid and removal from wall tamper detection
•Green ains present LED
•Available in unboxed (module only) format
•Red Fault diagnostic LED
•Volt free contact signalling mains failure (EPS)
•Volt free contact signalling output and battery
faults (GEN)
•Full electronic short circuit and overload
protection on load output under mains
operation
•Individual battery and output fuse protection
S
PECIFICATION
I put Specificatio
Voltage (rated) 100-240V ac
Voltage (operating) 90-264V ac
Frequency 50-60Hz
ax Current See odel Specification Table
ains Input Fuse See odel Specification Table
Output Specificatio
Voltage 12.8 – 14.2V dc (13.8V dc nominal) on mains power
9.8 – 13.0V dc on battery standby
ax load current See odel Specification Table
Ripple < 400 mV pk-pk max
Load output Fuse See odel Specification Table below
Overload Electronic shutdown until overload or short circuit removed (under mains
power only)
Sta dby Battery
Battery Type 12V Valve Regulated Lead Acid
Battery Capacity See below under echanical specification.
Battery Charging Fuse protection See odel Specification Table below
Elmdene International Ltd
Tel: +44 (0)23 9269 6638
3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483
Portsmouth,
Hampshire
,
PO3 5QD
, UK

Web:
www.elmdene.co.uk
Technical Support Line +44 (0)23 9269 6638 (Option 3) G1380xB -y-s PAK200569_01C June 2016 © 2016 Elmdene International Ltd
Mecha ical
Product Reference G1380xBM- -A G1380xBM- -B G1380xBM- -C G1380xBM- -D G1380xBM- -R
Dimensions
w x h x d (mm)
200 x 230 x 80 355 x 330 x 80 330 x 275 x 80 400 x 500 x 80 410 x 390 x 90
Battery Capacity 1 x NP7 (8Ah) 1 x NP17 (18Ah) 1 x NP17 (18Ah) 1 x NP17 (18Ah) 1 x NP17 (18Ah)
Weight (kg)
2.0 4.0 3.3 6.5 5.3
Unboxed odules Dimensions: 152L x 106W x52H (mm) Weight: 280g
Enclosure aterial
1.2mm steel white powder coated
E viro me tal
Temperature -10 to +40°C (operating) 75% RH non-condensing
-20 to +80°C (storage)
M
ODEL
S
PECIFICATION
T
ABLE
G13801BM G13802BM
Max Output Curre t to load 1A 2A
Output Fuse (20mm glass) F1.0A F2.0A
Max Mai s I put Curre t < 1.0A @ Full load < 1.0A @ Full load
Mai s I put Fuse (20mm 250Vac HBC) T2.0A T2.0A
Battery Fuse Protectio F1.0A F2.0 A
S
IGNALLING
O
UTPUTS
Rating: 0.10A @ 60Vdc 16Ω solid state relay contacts, volt free.
EPS Fault: Open if Loss of mains for >8s
GEN Fault: Open if Battery terminal voltage < 11.5Vdc (when operating in standby
with no mains present), battery not present or Output and/or battery
fuse blown
Tamper: 0.5A @ 30Vdc volt free contact. Open when lid is open or enclosure
removed from surface.
Fault Diag ostic Table:
Red LED
(Fault)
Gree LED
(Mai s) PSU Status
OFF ON Normal: Battery fully charged
One short flash
every second ON Normal: Battery charging but not fully charged
Flashing:
1second On
1 second Off
ON Fault: Output fuse or battery fuse blown, or battery missing
OFF Fault: No mains, output fuse blown
One short flash
every 3 seconds OFF Fault: No mains, battery supplying load.
OFF OFF Fault: No mains, No output, Batteries disconnected or completely
discharged
C
ONNECTIONS
O/P +, - Connection to equipment to be powered (Observe polarity)
EPS Fault: Relay output for mains fail. Open if loss of mains.
GEN Fault: Relay output for General Fault. Open in fault condition
BATT +, - Connection to standby battery. Use cables provided (Observe polarity)
Technical Support Line +44 (0)23 9269 6638 (Option 3) G1380xB -y-s PAK200569_01C June 2016 © 2016 Elmdene International Ltd
I
NSTALLATION
I
NSTRUCTIONS
This unit is only suitable for installation as permanently connected equipment. This PSU is NOT SUITABLE for external
installation. This unit must be fed from a mains power source having a separate (approved) disconnect device and fitted
with a fuse or other over-current protection device rated at 3A maximum. Ensure that the disconnect device used has
appropriate earth fault protection to the applicable standard. EQUIPMENT MUST BE EARTHED. Before installation,
ensure that external disconnect device is OFF.The PSU should be installed according to all relevant safety regulations
applicable to the application.
Fig 1.0 Mounting of Power Su ly
Mou ti g
1) ount securely in correct orientation allowing minimum clearance – see Fig. 1.0
2) Route mains and low voltage output cables via different knockouts and/or cable entry holes.
3) Use bushes and cable glands rated to UL94 HB minimum.
Mai s Power Up
4) Attach correctly rated mains cable (minimum 0.5mm
2
[3A], 300/500Vac). Fasten with cable ties.
5) Apply mains power.
Check for 13.8Vdc on load outputs.
Check Green ains LED is ON.
6) Disconnect mains power.
Load Output
7) Attach correctly rated load cable and fasten using cable ties. Note polarity.
8) Apply mains power.
Check Green ains LED is ON.
NOTE: Red Fault LED may flash to indicate no battery has been connected, this is normal.
Verify load is operating correctly.
9) Disconnect mains power.
Sig alli g
10) Connect EPS and GEN fault outputs to appropriate inputs of Control and Indicating Equipment (CIE).
Sta dby Battery
11) Attach supplied battery cables to terminal block and batteries.
NOTE: ensure correct polarity of battery connections: +ve use Red lead, -ve use Black lead.
Tamper
12) Check that the tamper screw makes good contact with the mounting surface. Check that the tamper switch is:
- closed when the lid is closed and the lid screw is fitted
- open when the lid is open.
13) Close cover and secure using fastening screw(s) provided.
O
PERATING
I
NSTRUCTIONS
In the event of loss of mains, a battery fault or a GEN fault, the corresponding Fault signal contacts will open (see Fault
diagnostic table for LED indicator status).
If the output of the PSU fails, the cause of the failure should be investigated e.g. short circuit load, connection of a
deeply discharged battery. The fault should be rectified before restoring power to the PSU. If any of the fuses require
replacing, ensure the correct fuse rating and type is used.
Technical Support Line +44 (0)23 9269 6638 (Option 3) G1380xB -y-s PAK200569_01C June 2016 © 2016 Elmdene International Ltd
M
AINTENANCE
This unit is intended for use by Service Personnel only. There are NO USER SERVICEABLE parts inside.
There is no regular maintenance required of the PSU other than periodic testing, and replacement of the standby
battery. Reference should be made to the battery manufacturer's documentation to determine typical/expected
battery life with a view to periodic replacement of the battery.
C
OMPLIANCE
This power supply unit meets the essential requirements of the following European Directives:
Low Voltage 2014/35/EU
E C 2014/30/EU
WEEE 2012/19/EU
RoHs2 2011/65/EU
D
ISPOSAL OF
P
RODUCT AT
E
ND OF
L
IFE
This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic
Equipment (WEEE) and 2013/56/EU (Battery). At the end of life, the product must be separated from
the domestic waste stream and disposed via an appropriate approved WEEE disposal route in
accordance with all national and local regulations.
Before disposal of the product, any batteries must be removed, and disposed separately via an
appropriate approved battery disposal route in accordance with all national and local regulations.
Package used batteries safely for onward transport to your supplier, collection point or disposal facility.
Caution: Risk of fire or explosion
if bare battery wires are allowed to touch.
See Specification for battery type information. The battery is marked with the crossed out wheelie bin
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
For more information see: www.recyclethis.info
The ackaging su lied with this roduct may be recycled.
Please dis ose of ackaging accordingly.

This manual suits for next models

6

Other Elmdene Power Supply manuals

Elmdene STX2410-H User manual

Elmdene

Elmdene STX2410-H User manual

Elmdene G2410BMU User manual

Elmdene

Elmdene G2410BMU User manual

Elmdene GEN2-08 Series User manual

Elmdene

Elmdene GEN2-08 Series User manual

Elmdene POE1230-C User manual

Elmdene

Elmdene POE1230-C User manual

Elmdene G240 BM Series User manual

Elmdene

Elmdene G240 BM Series User manual

Elmdene EN3-34-U User manual

Elmdene

Elmdene EN3-34-U User manual

Elmdene LPS-ENC-T Instruction Manual

Elmdene

Elmdene LPS-ENC-T Instruction Manual

Elmdene 2401ST User manual

Elmdene

Elmdene 2401ST User manual

Elmdene 2405ST Series User manual

Elmdene

Elmdene 2405ST Series User manual

Elmdene G1380xN-y-s Series User manual

Elmdene

Elmdene G1380xN-y-s Series User manual

Elmdene G1380 BMU-y Series User manual

Elmdene

Elmdene G1380 BMU-y Series User manual

Elmdene 2401ST User manual

Elmdene

Elmdene 2401ST User manual

Elmdene TR2 User manual

Elmdene

Elmdene TR2 User manual

Elmdene STX2405-MOD User manual

Elmdene

Elmdene STX2405-MOD User manual

Elmdene 2405ST Series User manual

Elmdene

Elmdene 2405ST Series User manual

Elmdene STX2401-C User manual

Elmdene

Elmdene STX2401-C User manual

Elmdene 20182423N User manual

Elmdene

Elmdene 20182423N User manual

Elmdene LPS-12-G2 Instruction Manual

Elmdene

Elmdene LPS-12-G2 Instruction Manual

Elmdene STX2410-MOD User manual

Elmdene

Elmdene STX2410-MOD User manual

Elmdene GEN3-08-y User manual

Elmdene

Elmdene GEN3-08-y User manual

Elmdene VRS124000-P Series User manual

Elmdene

Elmdene VRS124000-P Series User manual

Elmdene UNIVERSAL-12V-5A-M User manual

Elmdene

Elmdene UNIVERSAL-12V-5A-M User manual

Elmdene G13804NU User manual

Elmdene

Elmdene G13804NU User manual

Elmdene G2410BM-E User manual

Elmdene

Elmdene G2410BM-E User manual

Popular Power Supply manuals by other brands

Delta PCM-48V600W1B Series instruction manual

Delta

Delta PCM-48V600W1B Series instruction manual

Axio MET AX-3020L instruction manual

Axio MET

Axio MET AX-3020L instruction manual

Corsair CMPSU-600G user manual

Corsair

Corsair CMPSU-600G user manual

Speed Link PECOS SL-6915-SSV-01 manual

Speed Link

Speed Link PECOS SL-6915-SSV-01 manual

Exor RB2000LT user manual

Exor

Exor RB2000LT user manual

KEPCO BOP-H Series Operator's manual

KEPCO

KEPCO BOP-H Series Operator's manual

Delta PMT2 75 W Series Technical data sheet

Delta

Delta PMT2 75 W Series Technical data sheet

B+K precision MDL4U Series user manual

B+K precision

B+K precision MDL4U Series user manual

Corsair HX1200 manual

Corsair

Corsair HX1200 manual

Icom IC-PS15 instruction manual

Icom

Icom IC-PS15 instruction manual

PowerWalker VFI 30K CPG 3/3 user manual

PowerWalker

PowerWalker VFI 30K CPG 3/3 user manual

Unit UDP1306C user manual

Unit

Unit UDP1306C user manual

DekoLight LONG-FLAT LT-45-24 Product notes

DekoLight

DekoLight LONG-FLAT LT-45-24 Product notes

digi-tech HardWire V-10 owner's manual

digi-tech

digi-tech HardWire V-10 owner's manual

Black Box PDUBH14-S20-120V user manual

Black Box

Black Box PDUBH14-S20-120V user manual

KEPCO PAT 15-1 instruction manual

KEPCO

KEPCO PAT 15-1 instruction manual

KEPCO RKE 1500W SERIES Operator's manual

KEPCO

KEPCO RKE 1500W SERIES Operator's manual

I-Tech IT6821 user guide

I-Tech

I-Tech IT6821 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.