Before mounng, you can adjust the range of the PIR moon detector by moving the PCB (d) up or down inside
the detector. To do this, unscrew the two screws inside the detector and slide the plasc cover containing the
PCB up and down. On the sides you can see the numbers 1-5. The higher the number the further the range of
the detector. When you have set it to 1, the range is 5m, at 3 it is 7m, at 5 it is 10m. To mount the detector,
carefully drill out the required mounng holes in the rear cover of the detector; (e) for corner mounng, (f)
mounng on a flat wall. Then, using the rear cover as a template, mark the drilling holes on your wall. Aer you
have drilled these holes, mount the rear cover to the wall using the included screws and plugs. NOTE: To save
baery life, the PIR will pause for two minutes aer every detected movements. If aer two minutes the sensor
detects movement again, it will send a new signal. If the sensor detects movement and flashes the led (b) , this
indicates that baery voltage is low. In this case, replace the baery as soon as possible.
IMPORTANT WARNING
This package can contain small parts and/or material which can be dangerous to small children! Be aware of
this, and keep this away from small children!
SPECIFICATIONS
Baeries: 1,5V / AA x 3 Detecon: 10 meter x 110° (< 28°C).
Warm Up Time 2,5min. (±30sec.) Frequenty: 868 MHz
Range: Min.100m in open air Measurements: 110 x 60 x 40 mm
For more informaon about the ELRO HOME ALARM SYSTEM AG4000 visit www.elro.eu
-3-
Symbols:
Recycling and disposal: The WEEE symbol (a) means that this product and baeries must be disposed
separately from other household waste. When it reaches its end of life, take it to a designated waste collecon
point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural
resources! Read the manual (b) before use and store it in a safe place for future use and maintenance.
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam - Nederland (a) (b) V2
ü
GUARANTEE
Visit www.elro.eu
1
2
3
4
5
(d)
POS 1 = 5m
10m
7m5m
Mounng height
2 - 2,25m
Mounng height
2 - 2,25m
Mounng height
2 - 2,25m
POS 3 = 7m
10m
7m5m
POS 5 = 10m
10m
7m5m
(b)
INTRODUCTION
The moon detector AG40PR11 is designed for use with the HOME ALARM SYSTEM AG400011 and is designed
to detect movement.
INSERTING BATTERIES
Remove the back plate of the sensor by unscrewing the screw (a) at the boom. Then insert the 3 included AA
1.5V baeries. Once the baeries have been inserted, the PIR will warm-up during 2-3 minutes, and the LED (b)
of the sensor will flash to indicate it is warming up. Once the LED has stopped flashing, the PIR has finished
warming up.
LINKING TO THE HOME ALARM SYSTEM AG400011
Before mounng the sensor, you must first link the sensor to the alarm panel. When adding a sensor to the
alarm system, it can be added under five different security types that differ based on in which mode they can
give an alert and whether or not there is a delay. The types are:
- Security Type “0”: Fully Armed: The sensor will be acvated only when the system is in Full Arm mode. This
sensor will not be acvated in Paral Arm mode. When the sensor is triggered, the alarm will sound
immediately without any preset delay.
- Security Type “1”: Parally Armed and Fully Armed: The sensor will be acvated when the system is either
fully or parally armed. When the sensor is triggered the alarm will sound immediately without any preset
delay.
- Security Type “2”: Fully Armed + Delay: Same as Security Type “0”, except when the sensor is triggered the
alarm will sound aer a preset Entry delay. This is mostly used for the main entrance to prevent any
accidental triggering of the alarm by the user.
- Security Type “3”: Paral Arm and Fully Arm + Delay: Same as Security Type “1” except when the sensor is
triggered the alarm will sound aer a preset Entry delay. This is mostly used for the main entrance to
prevent any accidental triggering of the alarm by the user.
- Security Type “4”: 24Hrs intruder: The sensor will immediately trigger an alarm, regardless whether the
system is (parally) armed or disarmed. This is normally used to protect areas from any unauthorized access,
such as a safe box or an electrical maintenance room, etc.
When you have selected which security type fits best with the sensor you are using, follow these steps to link
the sensor to the alarm system:
1. Ensure you have inserted the baeries so that the sensor is powered on
2. On the alarm panel, enter your PIN + DISARM key to disarm the system.
3. Then enter your PIN + 15 + (Security Type) + PARM to start the binding process.
The DISARM LED will start to blink for 30 seconds with a beep tone.
4. Within 30 seconds, set the sensor to enter binding mode by pressing the tamper key on the back for a few
seconds and releasing.
5. If the sensor has been successfully linked to the alarm panel, the DISARM LED will turn on for 1 second
and you will hear a long beep. A keypad LED will turn on to indicate the zone number that has been assigned
to the sensor (Numbers 1-9 for zones 1-9, 0 for sensor zone 10 or higher). We advise you to note down the
locaon and the zone number.
6. If binding fails, it will meout aer 30 seconds and 3 short beeps will be heard.
7. To exit the binding process, press the DISARM key.
TESTING
Before mounng, it is wise to first test the contact where you want to mount it, to ensure it is within range of
the control panel. To test enable test mode on the alarm panel by entering your PIN + 03 + PARM key.
Next press and release the tamper switch on the back of the sensor when you are holding it near the place
where you want to mount it, you should now hear a chime from the alarmpanel. When you have finished the
test, press the DISARM key to exit test mode.
MOUNTING
1. The moon detector must not be placed facing a window that lets in direct sunlight. moon detectors are
not suitable for use in sunrooms or greenhouses.
2. The moon detector must not be placed in a room where there are pets when the alarm is enabled, this can
cause false alarms.
3. Do not place the moon detector in a place where a venlator is in its line of sight.
4. Do not place the moon detector directly above a heat source (e.g. fire, radiator, boiler, etc.)
5. Where possible, mount the moon detector in the corner of a
room, so that the logical path of an intruder would cut across the
detecon paern. Moon detectors are beer at detecng
movements across (g) their field of view, than they are at
detecng movement directly towards the unit
-1- -2-
UP
AA - 1,5V
AA - 1,5V
1 1
2 2
3 3
4 4
5 5
AA - 1,5V
(a)
(c)
(d) (d)
(f)
(f)
(e) (e)
(b)
110°
(g)

Other ELRO Security Sensor manuals

ELRO AS90MA User manual

ELRO

ELRO AS90MA User manual

ELRO FH380111R User manual

ELRO

ELRO FH380111R User manual

ELRO FH721011 User manual

ELRO

ELRO FH721011 User manual

ELRO PRO Sensus4H User manual

ELRO

ELRO PRO Sensus4H User manual

ELRO FH380111R User manual

ELRO

ELRO FH380111R User manual

ELRO FC270211 User manual

ELRO

ELRO FC270211 User manual

ELRO AS80MA11 User manual

ELRO

ELRO AS80MA11 User manual

ELRO AS90VS User manual

ELRO

ELRO AS90VS User manual

ELRO K2 CONNECTOR User manual

ELRO

ELRO K2 CONNECTOR User manual

ELRO HA2000PP User manual

ELRO

ELRO HA2000PP User manual

ELRO AS90PP User manual

ELRO

ELRO AS90PP User manual

ELRO FW380111R User manual

ELRO

ELRO FW380111R User manual

ELRO FW380111R User manual

ELRO

ELRO FW380111R User manual

ELRO FW380111R User manual

ELRO

ELRO FW380111R User manual

ELRO FC480111R User manual

ELRO

ELRO FC480111R User manual

ELRO FC451011 User manual

ELRO

ELRO FC451011 User manual

ELRO FH380111R User manual

ELRO

ELRO FH380111R User manual

ELRO ES360M User manual

ELRO

ELRO ES360M User manual

ELRO AS80PR11 User manual

ELRO

ELRO AS80PR11 User manual

ELRO K1 User manual

ELRO

ELRO K1 User manual

ELRO FH380111R User manual

ELRO

ELRO FH380111R User manual

Popular Security Sensor manuals by other brands

AVS Electronics SPECTRUM DT WS AM 4 manual

AVS Electronics

AVS Electronics SPECTRUM DT WS AM 4 manual

Baumer 10P66Y0/S35A Mounting instructions

Baumer

Baumer 10P66Y0/S35A Mounting instructions

PCB Piezotronics W200B03/002C20 Installation and operating manual

PCB Piezotronics

PCB Piezotronics W200B03/002C20 Installation and operating manual

Smanos MD7000 user manual

Smanos

Smanos MD7000 user manual

TELEDYNE OLDHAM SIMTRONICS Everywhereyoulook MultiFlame DF-TV7 operating manual

TELEDYNE OLDHAM SIMTRONICS

TELEDYNE OLDHAM SIMTRONICS Everywhereyoulook MultiFlame DF-TV7 operating manual

PCB Piezotronics 117B184 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 117B184 Installation and operating manual

Crestron GLS-ODT-C-CN installation guide

Crestron

Crestron GLS-ODT-C-CN installation guide

PCB Piezotronics W138A06 Installation and operating manual

PCB Piezotronics

PCB Piezotronics W138A06 Installation and operating manual

HAISEN HD020SR Product specification

HAISEN

HAISEN HD020SR Product specification

Ursalink UC11-N1 quick start guide

Ursalink

Ursalink UC11-N1 quick start guide

B+B Sensors REGME Operation manual

B+B Sensors

B+B Sensors REGME Operation manual

Diablo DSP-10 user manual

Diablo

Diablo DSP-10 user manual

Ksenia KSI5CLV-02.00W installation manual

Ksenia

Ksenia KSI5CLV-02.00W installation manual

Davicom DVLD-1 user manual

Davicom

Davicom DVLD-1 user manual

Orno OR-CR-208 quick start guide

Orno

Orno OR-CR-208 quick start guide

iPROTECT 1217 manual

iPROTECT

iPROTECT 1217 manual

Sebury F1 user manual

Sebury

Sebury F1 user manual

soloprotect ID quick start guide

soloprotect

soloprotect ID quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.