EOS Emotec D User manual

Made in Germany Firmware R4.02
IPx4 Print No. 29344767 en / 29.22
Technical changes reserved
EN Installation and operation manual
sauna control unit
EOS EmoTec D | EmoTec H

2EN
English
Inhalt
General safety precautions
Safety levels ....................................................................................................................................................... 4
Mounting and electrical installation..................................................................................................... 5-6
Operator instruction................................................................................................................................... 6-8
Standards and regulations........................................................................................................................... 8
Identication ............................................................................................................................................................ 9
Scope of delivery ..................................................................................................................................................10
Accessories ..............................................................................................................................................................10
Technical Data ................................................................................................................................................. 11-12
Intended Use...........................................................................................................................................................12
Installation
Main relay box.......................................................................................................................................... 14-18
Control panel - ush-mounting installation ................................................................................. 19-20
Control panel - surface-mounting installation ............................................................................ 21-22
Sensor installation.................................................................................................................................. 23-24
Bench sensor ...................................................................................................................................................25
Humidity sensor.............................................................................................................................................26
Electrical Installation
Installation steps, connections .................................................................................................................27
Connection overview - EmoTec D............................................................................................................28
Connection overview - EmoTec H............................................................................................................29
Main board layout - EmoTec D..................................................................................................................30
Main board layout - EmoTec H..................................................................................................................31
Heater sensor, bench sensor, humidity sensor, connections.........................................................32
Terminals, high limiter, light, fan, PFC ....................................................................................................33
Connection of the sauna heater and vaporizer..................................................................................34
Heating time limitation ...............................................................................................................................35
Data lines..........................................................................................................................................................35
Connecting the consumer lines ...............................................................................................................36
Closing the housing......................................................................................................................................37
Setup (commissioning)
Overview, main elements and functions ..............................................................................................38
Initial setup ......................................................................................................................................................39
Changing the cabin ID (address)..............................................................................................................41
Manual setting of the light source..................................................................................................................42

3
EN
Operation
Overview...........................................................................................................................................................43
Symbols (main menu)..................................................................................................................................44
Graphic user interface, checking climate condition .........................................................................45
Operation and settings (main functions)....................................................................................... 46-50
Symbols (extended settings).....................................................................................................................51
Operation and settings (extended settings)................................................................................. 52-54
Service level settings
Opening service level...................................................................................................................................55
Symbols.............................................................................................................................................................56
Settings ...................................................................................................................................................... 57-58
Potential free contact (PFC) ................................................................................................................ 59-62
Error messages (Troubleshooting)........................................................................................................... 63-64
Recycling ..................................................................................................................................................................67
Service address ......................................................................................................................................................67
General terms and conditions of service .............................................................................................. 67-68

4D
Safety instructions and important operating instructions are classied. Please familiarise yourself
with the following terms and symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result in minor or moderate in-
jury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in damage to the unit.
General safety instructions
Safety levels

5
D
Mounting and electrical installation
These installation instructions are intended for qualied personnel familiar with
the laws and regulations applicable to electrical installations at the installation
site. Observe the following general safety instructions during mounting, cong-
uration and commissioning of the product.
Risk to life and limb and risk of re
Risk to life and limb from electric shock and re in the event of improper or faulty electrical
connection. This risk also applies following completion of the installation work.
• The electrical installation of the relay box and other electrical systems or equipment with
a xed mains connection must only be performed by a trained electrician from an author-
ised electrical company.
• Observe the stipulations inVDE 0100 part 703 or the applicable local legal requirements.
• The system must be completely disconnected from the mains supply before commencing
installation and repair work.
• The housing cover must only be removed by a specialist.
Fire hazard from overheating
Insucient ventilation can lead to device overheating and re. Flammable parts inside sau-
na must not exceed a temperature of 140°C when the unit is operated as intended or in the
event of a malfunction.
• Do not install control panels, relay boxes and modules in enclosed cabinets or wood pan-
elling.
• Observe the sauna heater manufacturer’s safety and installation instructions.
• Observe the cabin manufacturer’s safety and installation instructions.
• Touchable glass surfaces on the outside of the cabins must not reach more than 76°C. Oth-
erwise provide proper protection.

6D
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the control panel, in the relay
box and in the sensors.
• The control panel and sensors should not be installed in a corrosive or heavy saline atmos-
phere.
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use!
• It may be operated only inside buildings and may not be exposed to environmental condi-
tions such as extreme humidity and moisture or the possible formation of condensation or
corrosive substances in the ambient air, as well as other weather conditions.
• Similarly, excessive cold and extreme exposure to sunlight must be prevented.
• Protect the unit accordingly if there is an increased risk of mechanical damage.
Operator instruction
The operator of the infrared or sauna cabin must be instructed on the general safety instruc-
tions during commissioning.The operator must be given a copy of the operating instructions.
The operator must make the end user aware of safety instructions that are relevant to the
end user.
Risk of electric shock
A risk to life and limb from electric shock and re arises in the event of improper repair work.
This risk also applies after work is completed.
• The housing covers may only be removed by a specialist.
• Repairs and installations may only be performed by a trained specialist.
• The system must be completely disconnected from the mains supply before commencing
repair work.
• Use only original spare parts from the manufacturer.

7
D
Fire hazard
Objects placed on the sauna heaters can ignite and cause re.
• Do not place objects on the sauna heater.
• If you switch on the sauna heater using a pre-set timer or a remote control, use a cover
protection sysem for the heater or install a suitable safety device.
• Inspect the cabin prior to switching it on.
• When using control units with a remote control option (see EN 60335-1), protection from
switching on a covered sauna heater is required.
Risk of burns and chemical burns
Touching hot parts may lead to skin burns.
• The operator must be familiar with the unit’s hot parts and be able to identify them.
• The operator must be familiar with the settings for the heating time and understand how
to adjust it.
Health risks
Spending time in an infrared or sauna cabin can lead to serious health risks or even death for
persons with health impairments.
• Persons with health impairments who spend time in a sauna must consult a doctor before
entering an infrared or sauna cabin.
Equipment damage due to overuse
The uninterrupted operation time of the sauna cabin(s) can lead to property damage.
• If the sauna cabin is used commercially, the heating time must be set so that it switches o
automatically after a specic period of time.
• If the heating does not switch o automatically after a dened heating period, cabin use
must be supervised at all times.
• Inspect the cabin before each use.

8D
Operation by children or persons with reduced mental capacity
Children and persons with reduced mental capacity can put themselves at risk.
• Children must be supervised to ensure they do not play with the unit.
• Children under 8 years of age may not operate the sauna cabin.
• The settings for the heating time may only be carried out by children under 8 years of age
if they are supervised by an adult.
• The sauna cabin must only be used by persons with reduced mental capacity, or limited
physical or sensory abilities under supervision or if they have been previously instructed in
its use and understand the risks.
• Children and persons who have not received proper instruction may not clean or service
the system.
Standards and regulations
For an overview of the standards that were observed during design and construction of
the sauna heaters, please refer to the individual product‘s technical data sheet that can be
downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating, sauna, and steam
room systems.

9
EN
Identication
Foreseeable misuse
The EmoTec D or H control unit consists of a relay box, a control panel, a temperature sensor and
the connecting cables, and is used to operate a sauna cabin.
Additional modules/devices can be connected to the relay box for total control of a sauna cabin,
for example, lighting, fan and additional sensors.
Identification of the units
The nameplate is attached to the underside of the base of the relay box housing.
The following are considered instances of foreseeable misuse:
• The control and sensor cable plugs are plugged in incorrectly.
• The unit is operated without knowledge of or compliance with the safety instructions.
• Operating, service and maintenance requirements are not observed.
• The unit is operated after technical or other modications are made to the relay box.
• The unit is operated by children under the age of 8 years or by child-
ren above the age of 8 years and persons with reduced mental capaci-
ty without being thoroughly instructed in its use or supervised.
The manufacturer is not liable for unauthorised modications made to the equipment and dama-
ges resulting from these modications. The person modifying the equipment alone shall bear the
associated risk.
Read the General Safety Instructions.
Saunasteuergerät
IPX4
Type EOS EmoTec D
Art. Nr. 94 XXXX 00
400V 3N ~ 50 Hz
Maximale Schaltleistung 9 kW
Made in Germany
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 0000506.21
A
B
C
D
E
F
G H
A. Name
B. Model
C. Item number
D. Operating voltage
E. Country of origin
F. Manufacturer
G. Production date
H. Serial number

10 EN
2nd sensor (bench sensor) ..........Item no. 94.5725
Humidity sensor........................Item no. 94.5726 (for H models)
Coloured light control module...Item no. 94.5996, 94.6007
Sound module...........................Item no. 94.5920, 94.5921
Remote start module ................Item no. 94.5782
SBM-App module......................Item no. 94.5987
KNX-/Modbus-module..............Item no. 94.7078 / 94.7077
SBM-HOT...................................Item no. 94.6800
SBM-ECO...................................Item no. 94.6980
EOSafe.......................................Item no. 94 7149-7153
Accessories (optionally available):
A. Relay box with 2-piece front cover
B. Control panel with TFT display
C. Bottom housing for the ush-mounting installation
D. Bottom housing for the on-surface installation
E. Temperature sensor kit, comprising
Sensor housing
Temperature sensor board
Safety temperature limiter board
2 mounting screws 4 x 40 mm
Sensor line 5 m with RJ10 plug
F. Line for safety temperature limiter 5 m, white
G. Spare safety temperature limiter
H. installation and operation manual
I. Removal tool for the control panel
J. Connection cable 5 m for control panel, RJ10/RJ14
K. Plastic bag with 3 mounting screws 4 x 25 mm.
L. 8 rubber bushings (cable glands)
Scope of delivery
A
H
F
KL J I
E
G
DCB
The following components are included in the scope of delivery:

11
EN
Voltage (power supply): 400 V 3 N ~ 50 Hz
Switching capacity: max. 9 kW resistive load, may be extended with a power ex-
tension unit (LSG)
Fuse 3 x 16 A
Heating time limit: 6 h / 12 h / 18 h / unlimited
Housing: plastic, shatter-resistant
Display: TTFT colour display 55 x 74 mm (3,5“ size)
Operation: 2 direct buttons for On/O and light, jog-dial switch
Temperature control range: 30° - 115°C (dry sauna mode)
30° - 70°C (humid sauna mode - only H)
Humidity control: proportional to time or optionally as per rel. air humidity (%)
with an optional humidity sensor.
Sensor system: Digital sensor with overheating protection fuse (STB) 139°C
Control characteristic: Digital two-point control
Connection for fan: min. 5 W, max.150 W (only fans without starting capacitor)
Only use fans suitable for phase leading edge control!
Connection for light: • min. 5 W (20 mA)
• resistive loads - max. 100 W,
• dimmable energy saving lamps - max. 35 W
• Lamps at conventional transformers - max. 60 VA.
Attention: only dimmable lamps must be used!
Fan and light output share a common 2AF fuse.
Volt-free output: contact’s resistive load carrying capacity:
maximum current: 10 A
maximum voltage: 30 V DC / 250VAC
Start time pre-selection: up to 24 h in advance
Switching automation: Week timer with 4 switching programs per day
Error display: Clear text error indication on the display
Outputs: 3 x RJ10 jacks for sensor connections
2 x RJ14 jacks for control panel and extension modules
1 x potential free contact (2 terminals)
Output S1: maximal load 50 W / 50 VA, no capacitive loads allowed.
Terminal block area for power
supply and heater connection:
0.5 – 2.5 mm² rigid or exible crimped wire, two cores with
the same cross section per terminal may be connected
Terminal block area WM, 3, 4, light,
fan:
0.34 – 2.5 mm² rigid or exible crimped wire. Please observe
the minimal cross section as per fuse protection of the line!
Technical data

12 EN
Important note!
The control unit is not suitable for outdoor use!
It must only be used inside buildings and may not be exposed to environmental condi-
tions such as extreme humidity or moisture with possible condensate formation or corro-
sive substances in the ambient air and other weathering. Excessive exposure to cold and
intense solar radiation should be avoided as well. If there is an increased risk of mechani-
cal damage, the control unit must be protected accordingly.
Card reader: Micro-SD card slot in control panel
Ambient temperatures: -10°C bis +35°C
Storage temperatures: -20°C bis +60°C
Place of installation requirement: Intended for indoor installation only.
Sensors - may not be installed in corro-
sive or highly salty environment.
Device - may not be installed in corrosive environment or
in an environment which may cause water condensation.
Dimensions main block: H 270 x W 300 x D 100 mm
Dimensions control panel: H 127 x W 130 x D 25 mm (ush-mounting)
recessed part 20 mm deep
Intended use
In conjunction with a suitable sauna heater, the EmoTec D control unit is intended to be used only
to heat sauna cabins. It is suitable for residential and commercial sauna cabins. Any further use is
deemed not to be in accordance with the intended purpose!
The intended use also includes compliance with the usual operating, maintenance and servicing
conditions.
The relay box and control panel are intended only for mounting on the wall.

13
EN
Installation
This chapter describes how to install the relay box and the most important components.
Cables with the appropriate cross section should be used for the heater, vaporizer (steam genera-
tor) or an other heating system, as well the light, fan and other components.
All electrical installations and all connecting lines that are installed inside a cabin must be suitable
for a use in a sauna / IR cabin (IPx4 class) or in a steam room / hammam (IP 65). All lines must be
routed in such a way that they are well-protected, e.g. in a cable duct.
NOTICE
NOTICE
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use!
• It must be operated only inside buildings and may not be exposed to environmental conditions
such as extreme humidity and moisture or the possible formation of condensation or corrosive
substances in the ambient air, as well as other weather conditions.
• Similarly, excessive cold and extreme exposure to sunlight must be prevented.
• Protect the unit accordingly if there is an increased risk of mechanical damage.
Electronics malfunctions
Routing data and power supply lines together can lead to electronics malfunctions because, e.g.
because the sensor will not be detected.
• Do not route sensor and sauna bus lines together with power supply lines.
• Route separate cable conduits.
Site requirements
• Ambient temperature during operation -10°C to 35°C
• Relative air humidity during operation 30% to 75%
• Ambient air may not be corrosive or have high salt content
• Storage temperature -20°C to +60°C
• Stable wall able to carry unit‘s weight
• Power supply 400 V 3N ~ 50 Hz nearby
• All cable lines and connections must be accessible for servicing.

14 EN
Relay box installation
The relay box may be installed only outside the cabin. Recommended installation locations are e.g.
outer wall of the cabin, plant room in order to suit the local installation situation. If empty conduits
for electrical installations are already present, this dictates the position of the relay box. Observe
the following guidelines for the installation.
WARNING
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and re in the event of improper or faulty electrical con-
nection. This risk also applies following completion of the installation work.
• Do not install relay boxes in enclosed cabinets or wood panelling.
Extending the control unit‘s control line
For extra-long connections special Sauna Bus type cables with the length 10 m, 25 m and 50 m are
available. Use the cable type RJ14/RJ10 for display panel connection and the cable type RJ12/RJ12
for a connection to a dierent module.
Alternatively the included Sauna Bus cable can be extended with an additional cable RJ12/RJ12 or
RJ14/RJ10 using a coupler RJ12/RJ12. For certain display panel types (e.g. EmoTouch 3)an additio-
nal power adaptor will needed is the line length is over 25 m.
The power adaptor, the extension cables and couplers sind are optionally available.
See optional accessories.
Installation works inside the cabin
At minimum, the temperature sensor, the cabin lighting and, depending on the cabin type the air
supply / air outlet, if required with a fan, must be installed in the cabin. Additional connections
are possible depending on the cabin type and selected options, e.g. additional sensors or a steam
outlet by an external vaporizer.

15
EN
1.
2.
1.
2.
210
180
3
Fig. 1
Fig. 2
The power supply, S-Bus and sensor lines can be routed to the relay box as follows:
• The lines can be routed along the outer wall of the cabin. They are then passed into the housing
from below. If they are not routed through a cable conduit or a duct, they must be secured so
they cannot be pulled out.
• The cables can be routed between the insulation and the outer wall of the cabin. They are then
passed into the housing from the rear.
Installing the relay box
Necessary steps:
1. Preparing the installation
• Determine a suitable location.
• Route the lines.
2. Remove the hosing cover (Fig. 1)
• Unscrew the 6 screws for both
parts of the housing.
• Remove both halves of the cover.
3. Mount the relay box
• Drillone(1)holeaboveandtwo(2)holesbelow.
Horizontaldistancebetweendrillholes:210mm
Vertical distance between drill holes: 180 mm
• Insert the anchors as needed and screw in the
top screw. Allow the screw to protrude ap-
prox. 3 mm so you can hook in the relay box.

16 EN
180 mm
210 mm
180 mm
210 mm
bottom mounting holes
Fig. 4
Fig. 3
Fig. 5
A. Mains cable, cables for heating, light etc.
B. Low-voltage lines, e.g. sensor, S-Bus lines.
top mounting hole
4. Open the relay box conduits for the lines.
5. Insert supplied rubber grommets into the
openings of the lower part of the housing.
6. Route the connecting cables through the
openings. A B
7. Hook the relay box into the upper screw using
the upper mounting hole.
8. Securely tighten the relay box using the two lo-
wer mounting holes.
• Once you have completed all installation work
you can connect the consumers and plug in
the lines.
• Connect the data cables (sauna bus / sensor
bus lines - see also Electric Connections).
• Connect and congure the electric consu-
mers (see also Electric Connections).
9. Finally close the housing with the front covers
and secure them with 6 screws.

17
EN
Cabin lighting
Fan
Lighting can be installed anywhere, however
not near rising hot air or hot steam. The light
output in the relay box is set to inductive load
by default, but light bulbs, halogen HV bul-
bs and other resistive loads may also be con-
nected to it. If required, the light output can
also be manually set to capacitive loads.
For light conguration see„Manual light con-
guration“ chapter.
Cabin lighting is not included in the scope of
delivery. Observe the separateinstallation in-
structions for lighting.
Requirements to cabin lighting
• Lighting must be dimmable
• Minimal power output 5 W
• Resistive loads max. 100 W
• Dimmable energy-saving lamps max. 35 W
• Light sources with conventional transfor-
mers max. 60 VA
The relay box features an output for a fan. A
ventilation fan can be connected and operated
using this output.
The fan is not included in the scope of delivery.
Observe the separate installation instructions
for the fan.
For connection please refer to the chapter
„Electric Connections“.
Requirement to a fan
• Minimal power 5 W
• Maximum power 150W
• Voltage 230 V 1N AC
• Suitable for installation in humid condi-
tions (IP65)
• Only fans without starting capacitor
NOTICE
Material damage by unsuitable lamps or installation place
Lighting and the control panel could become damaged if nondimmable light sources are installed.
In this case, the warranty becomes void.
• Do not install the lighting in areas with rising hot air or hot steam.
• The lighting must conform to protection class IPX4 in saunas / IR cabins or IP65 in steam
rooms / hammams and be resistant to ambient temperatures.
• Connect only dimmable light sources.

18 EN
Potential free contact (PFC)
The relay box features a potential free contact.
You can include this NC (normally closed)
contact in any electric circuit to switch an ex-
ternal load or transmit a signal.
Maximum load
• Resistive load / alternating current 250 V
AC / 10 A
• Inductive load / alternating current 500 VA
• Direct current
• Up to 30 V DC max. 10 A (300 W)
• Up to 110 V DC max. 0,3 A (33 W)
• Up to 220 V DC max. 0,12 A (26,4 W)
NOTICE
Material damage due to short circuiting
The supply line can short circuit if you use the mains connections L1, L2 or L3 to supply the electric
circuit connected to the potential-free contact.
• Use the mains and other connections in the relay box only as shown in the connection dia-
gram.
• Do not connect additional devices to the mains connections of the relay box.
• Connect the device connected to the potential-free contact and ensure that it is protected
from short circuiting.
• Observe the maximum load of the potential-free contact.

19
EN
Guidelines
Extending the control panel‘s control
line
The housing for control panel is available in
two versions: for mounting in the wall or for
mounting on the wall. Both versions are de-
signed for a mounting location on the outer
wall of the cabin.
If empty conduits for electrical installations are
already present, this dictates the position of the
control panel.
The cabin wall must be designed in such a way
that the temperature in the area in which ca-
bles are routed cannot exceed 75°C.
The following guidelines apply depending on
the cabin wall:
• Mounting in the wall – insulation:The control
line must only be routed between the insula-
tion and the outer wall of the cabin.
• Mounting in the wall – wooden planks: The
control line is routed between the inner wall
and outer wall of the cabin.
• Mounting on the wall – wooden planks: The
control line is routed along the outer wall of
the cabin.
For longer connections, special RJ10/RJ14 con-
necting cables with lengths of 10 m, 25 m, 50 m
and 100 m are available as an option.
Alternately, the supplied (as standard) 5-m line
can also be extended with an RJ12/RJ12 cou-
pling and an RJ12/RJ12 extension cord.
The extensions and couplings are available as
options.
See Accessories (optional, see chapter Scope of
Delivery).
Control panel
A
A
A
C
C
C
D
D
D
B
A. Inner wall of cabin
B. Insulation
C. Control line
D. Outer wall of cabin
Mounting in the
wall for cabin walls
with insulation
Mounting in the
wall for cabin walls
made of wooden
planks
Mounting on the
wall for cabin walls
made of wooden
planks

20 EN
Mounting location for control panel
Mounting the housing
The control panel is to be mounted outside of
the cabin. Preferably, it should be mounted on
the hinge-side of the door (not the opening
side). This prevents hot air from reaching the
control panel when the cabin is in use, which,
in the event of unfavourable ambient tempera-
tures in the ante-room, could cause condensa-
tion to form on/in the control panel.The follow-
ing distances are recommendations:
The control line from the relay box is connect-
ed to the control panel. The control line is fed
through the opening in the housing. Therefore,
it must be installed once the cut in the wall has
been made.
Tools required:
• Saw for cutting the wall (only when mount-
ing in the wall)
• Phillips screwdriver
• Removal tool to loosen the front panel (in-
cluded in the scope of delivery)
• Taught wire, as needed
• Wooden screws (included in the scope of
delivery):
4 screws for housing mounted in the wall
with a wall thickness of >30mm
3 screws for housing mounted on the wall
Necessary steps:
• Remove the display panel from the hous-
ing
• Mount the housing in the wall, or
• Mount the housing on the wall
ca. 340 mm
120 mm
117 mm
ca. 340 mm
eye height
eye height
Mounting location
Gaps
Other manuals for Emotec D
3
This manual suits for next models
1
Table of contents
Other EOS Control Unit manuals
Popular Control Unit manuals by other brands

Trinamic
Trinamic PD-1160 Getting started

Dyna-Flo
Dyna-Flo 570 Operation, Parts, and Instruction Manual

GEM
GEM 613 Installation, operating and maintenance instructions

Elektrogas
Elektrogas VML Series Technical manual

Leadshine
Leadshine 2CS3E Series user manual

Hacker
Hacker UAV Control Opto Pro Series manual