EOS 94 00 Series User manual

Druck-Nr.: 2902 5162
Stand: 17.2021
EN
Made in Germany
EOS Compact DC/HC
Control Unit for Sauna Cabins
Installation and Operating Instructions

EN-2 Installation and Operating Instructions - EOS Compact DC/HC
EN Documentation
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorisation, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-514
Fax +49 2775 82-431
Email ser[email protected]
Web www.eos-sauna.de
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
Date Version Description
1 May 2021 01.00 First version

EOS Compact DC/HC - Installation and Operating Instructions EN-3
Contents
Documentation ..................................................................................................EN-2
1 General safety instructions ..........................................................................EN-6
1.1 Safety levels................................................................................................EN-6
1.2 Mounting and electrical installation .................................................EN-6
1.3 Operator instruction................................................................................EN-9
1.4 Standards and regulations................................................................. EN-11
2 Identification.................................................................................................... EN-12
2.1 Scope of delivery ................................................................................... EN-12
2.2 Nameplate ............................................................................................... EN-13
2.3 Sensors...................................................................................................... EN-13
2.4 Technical data ........................................................................................ EN-14
2.5 Accessories .............................................................................................. EN-16
2.6 Intended use ........................................................................................... EN-17
3Installation........................................................................................................ EN-18
3.1 Routing the lines.................................................................................... EN-18
3.2 Installation site ....................................................................................... EN-19
3.3 Mounting the control unit ................................................................. EN-22
3.4 Mounting the heater sensor.............................................................. EN-30
3.5 Mounting the multisensor (optional) ............................................ EN-34
3.6 Mounting the bench sensor (optional) ......................................... EN-36
3.7 Mounting the cabin lighting............................................................. EN-36
3.8 Mounting the fan .................................................................................. EN-37
4 Connecting the lines..................................................................................... EN-38
4.1 Circuit board assignment for EOS Compact HC......................... EN-40
4.2 Circuit board assignment for EOS Compact DC......................... EN-41
4.3 Connecting the sensor cables .......................................................... EN-42
4.4 Connecting optional modules.......................................................... EN-44
4.5 Connecting the consumer lines....................................................... EN-45
4.6 Potential-free contact.......................................................................... EN-53
4.7 Checking for proper installation of the vaporiser ..................... EN-54

EN-4 Installation and Operating Instructions - EOS Compact DC/HC
EN
5 Commissioning................................................................................................EN-55
5.1 Setup ..........................................................................................................EN-55
5.2 Defining the light source ....................................................................EN-57
5.3 PFC function ............................................................................................EN-58
5.4 Fan function.............................................................................................EN-59
6Operation...........................................................................................................EN-61
6.1 Controls .....................................................................................................EN-61
6.1.1 Rocker switch (on, off, light only).....................................EN-61
6.1.2 Buttons and screen ...............................................................EN-62
6.1.3 Screen saver and sleep mode ...........................................EN-62
6.1.4 Instructions for operation...................................................EN-63
6.2 Main menu ...............................................................................................EN-64
6.3 Status bar..................................................................................................EN-65
6.4 Keypad lock..............................................................................................EN-66
6.5 Display settings ......................................................................................EN-66
6.5.1 Time............................................................................................EN-66
6.5.2 Display brightness ................................................................EN-67
6.6 Setup/reset...............................................................................................EN-67
6.7 Sauna controls ........................................................................................EN-68
6.7.1 Switching the sauna heater on/off..................................EN-68
6.7.2 Dimming or switching the light on/off..........................EN-69
6.7.3 Selecting Finnish/Bi-O mode.............................................EN-70
6.7.4 Temperature............................................................................EN-70
6.7.5 Setting the humidity for Bi-O mode ...............................EN-71
6.7.6 Heating period – auto stop................................................EN-72
6.7.7 Timer ..........................................................................................EN-73
6.7.8 Profiles .......................................................................................EN-75
6.7.9 HOT mode (intense heating).............................................EN-75
6.7.10 ECO mode (temperature decrease) ................................EN-76
6.7.11 Retrieving temperature/humidity values .....................EN-76
6.7.12 Switching the PFC on/off manually ................................EN-77
6.7.13 Switching the fan on/off manually..................................EN-77
6.8 Advanced settings.................................................................................EN-78
6.8.1 Runtime for ECO mode........................................................EN-78
6.8.2 Runtime for HOT mode .......................................................EN-79

EOS Compact DC/HC - Installation and Operating Instructions EN-5
6.8.3 Modes – holiday cottage, holiday resort, remote ..... EN-79
6.8.4 Temperature control............................................................ EN-81
6.8.5 Remote control ...................................................................... EN-82
7 Maintenance..................................................................................................... EN-83
7.1 Cleaning.................................................................................................... EN-83
7.2 Maintenance ........................................................................................... EN-83
7.3 Display of software and serial number.......................................... EN-84
7.4 Display of connected modules......................................................... EN-84
7.5 Display of contact information......................................................... EN-84
8Troubleshooting............................................................................................ EN-85
8.1 Error messages ....................................................................................... EN-85
8.2 Malfunction ............................................................................................. EN-87
9 General terms and conditions of service ........................................... EN-88
10 Disposal .............................................................................................................. EN-91

EN-6 Installation and Operating Instructions - EOS Compact DC/HC
EN General safety instructions
1 General safety instructions
1.1 Safety levels
Safety instructions and important operating instructions are clas-
sified. Please familiarise yourself with the following terms and
symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.
1.2 Mounting and electrical installation
These installation instructions are intended for quali-
fied personnel familiar with the laws and regulations
applicable to electrical installations at the installation
site. Observe the following general safety instructions
during mounting, configuration and commissioning
of the product.

EOS Compact DC/HC - Installation and Operating Instructions EN-7
General safety instructions
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
The electrical installation of the control unit and other electrical
systems or equipment with a fixed mains connection may be
performed only by a trained electrician from an authorised elec-
trical company.
Ensure compliance with the applicable standards and regula-
tions for electrical installation.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover must only be removed by a specialist.
Fire hazard from overheating
Insufficient ventilation can lead to device overheating and fire.
Do not install control panels, relay boxes and modules in en-
closed cabinets or wood panelling.
Observe the sauna heater manufacturer's safety and installa-
tion instructions.
Observe the cabin manufacturer's safety and installation in-
structions.
Touchable glass surfaces on the outside of the cabins could
reach a maximum of 76°C. Attach safety systems if needed.
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and in the sensors.
The control panel and sensors should not be installed in a cor-
rosive or heavy saline atmosphere.

EN-8 Installation and Operating Instructions - EOS Compact DC/HC
EN General safety instructions
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.

EOS Compact DC/HC - Installation and Operating Instructions EN-9
General safety instructions
1.3 Operator instruction
The operator of the sauna cabin must be instructed in the general
safety instructions during commissioning. The operator must be
given a copy of the operating instructions.
The operator must make the end user aware of safety instructions
that are relevant to the end user.
The operator must be familiar with the settings for the heating pe-
riod and understand how it is controlled.
Fire hazard
Objects left on the heater and/or directly in front of
an IR emitter can catch fire and lead to fires.
Do not place objects on the heater and/or directly in front of an
IR emitter.
Fill the rock store as directed.
Inspect the sauna cabin prior to each commissioning.
If you switch on the heater using pre-set timers or a remote con-
trol, attach a protective cover to the heater or install a suitable
safety device.
When using control units with a remote control* option (see
EN 60335-1), protection from switching on a covered sauna
heater is required.
* Remote control = setting up, controlling and/or regulating a
device with a command that can be given outside of the visual
range of a device, whereby the transmission media such as tel-
ecommunication, audio engineering or bus systems are used;
also included are pre-set timers and weekly timers.

EN-10 Installation and Operating Instructions - EOS Compact DC/HC
EN General safety instructions
Risk of electric shock
A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk also applies after work is com-
pleted.
The housing cover must only be removed by a specialist.
Repairs and installations must only be performed by a trained
specialist.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.
Health risks
Spending time in an infrared or sauna cabin can lead to serious
health risks or even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering an infrared or sauna cab-
in.
Equipment damage due to overuse
Excessive humidity in commercial infrared or sauna cabins can
lead to property damage.
In a commercial infrared or sauna cabin, the heating period
must be set so that it switches off automatically after a specific
period of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.

EOS Compact DC/HC - Installation and Operating Instructions EN-11
General safety instructions
Operation by children or persons with reduced mental
capacity
Children and persons with reduced mental capacity can be a risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 years of age should not operate the sauna
cabin.
The settings for the heating period must only be used by chil-
dren under 8 years of age if they are supervised by an adult.
The sauna cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have already been instructed in its use and
understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.
1.4 Standards and regulations
For an overview of the standards that were observed during design and
construction of the sauna heaters, please refer to the individual product's
technical data sheet that can be downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.

EN-12 Installation and Operating Instructions - EOS Compact DC/HC
EN Identification
2 Identification
The scope of delivery of the EOS Compact control unit includes a control
unit, a heater sensor with connecting cables for the sensor, and safety tem-
perature limiter. The unit is used to operate a sauna cabin.
EOS Compact is available in two models:
EOS Compact DC: Finnish sauna mode
EOS Compact HC: Finnish or steamy hot air bath mode
This documentation describes both models.
2.1 Scope of delivery
Scope of delivery
Check the scope of delivery for completeness prior to installation.
A EOS Compact control unit
B Installation and Operating
Instructions
C 2 screws to attach the heater sensor
(3 x 25 mm)
D Heater sensor with safety
temperature limiter
E Sensor cable (2 m) and safety
temperature limiter (2 m)
F Replacement safety temperature
limiter (in control unit housing)
G 4 screws to attach the control unit
(4 x 25 mm)
H Bushings: 8 large, 2 small
I Screwdriver 2 mm
B
E
A D
FGHI
C

EOS Compact DC/HC - Installation and Operating Instructions EN-13
Identification
2.2 Nameplate
The nameplate is attached to the top of the control panel housing cover.
Nameplate (example)
2.3 Sensors
Heater sensor
The temperature/humidity in the sauna cabin is set via the control unit. The
set values are checked by the sensor. The heater sensor controls the tem-
perature in the sauna cabin. The heater sensor has a safety temperature
limiter, which ensures that the temperature does not exceed 140°C.
Internal view of heater sensor
A Name
B Model
C Item number
D Operating voltage
E Switching output
F Country of origin
G Manufacturer
H Manufacturing date
I Serial number
A Temperature sensor B Safety temperature limiter
Saunasteuergerät / Control unit
Type EOS Compact
Art. Nr. 94 XXXX 00
400 V 3N AC 50 Hz
Max. Schaltleistung 10 kW
Made in Germany
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 0121 00001
IPX4
A
B
C
D
E
F
G
HI
A B

EN-14 Installation and Operating Instructions - EOS Compact DC/HC
EN Identification
Bench sensor (optional, EOS Compact DC/HC)
You can improve heat distribution in very large saunas where air circulation
is a challenge by using an additional bench sensor.
If a bench sensor is installed, it assumes control of the temperature. How-
ever, the heater sensor does not control the cabin temperature, rather it
limits the temperature within the maximum permissible range via the
heater. Exceeding the permissible temperature range would trigger the
safety temperature limiter.
If the bench sensor fails, the heater sensor regulates the temperature.
Multisensor (optional, for EOS Compact HC only)
The multisensor is a special sensor that can function as a humidity sensor
and a temperature sensor (bench sensor). The multisensor checks either
the humidity or the temperature in the sauna cabin. In Bi-O mode, the mul-
tisensor controls the relative air humidity in %. At the same time, the con-
trol unit attempts to keep the set humidity as precisely as possible.
If the sauna is in Finnish mode, the temperature is measured and con-
trolled, not the humidity.
The heater sensor continues to monitor the temperature behaviour and
only intervenes for safety reasons when it is necessary prevent overheating
via the heater.
If the multisensor fails, the heater sensor regulates the temperature.
2.4 Technical data
Technical data
Ambient temperature -10°C to +40°C
Storage temperature -20°C to +70°C
Housing Plastic
Dimensions (H x W x D) 220 x 255 x 65 mm
Weight Approx. 1.2 kg
Power supply 400 V 3N AC 50 Hz
Switching output 10 kW
Protection class IPx4 splash-proof
Temperature control
range
Finnish sauna mode: 30–115°C
Steamy hot air bath (Bi-O): 30–70°C

EOS Compact DC/HC - Installation and Operating Instructions EN-15
Identification
Humidity control
(HC only)
Without humidity sensor: Cycle (1–100) in proportion
to time for active humidity mode
With humidity sensor: according to relative air humid-
ity in %
Water level monitoring
(HC only)
Detects water shortage with automatic switch off after
3 minutes (only with compatible sauna heater)
Connection for lighting Min.5W(20mA)
Resistive load: max. 100 W
Energy-saving bulbs, max. 35 W
Light source with conventional transformers, max.
60 VA.
Fan and light connections are protected by a joint 2A F
fuse.
Light dimming Possible for light sources with phase-cut dimmer.
Resistive loads (e.g. light bulbs) and inductive loads
(e.g. LED light source) are suitable. Capacitive loads
(phase control) are not supported.
Connection for fan Max. 100 W
Sensor system
(Temperature)
KTY sensor with
safety temperature limiter 139°C
Temperature display for
heater sensor
Current value at heater sensor minus 7 K to offset
higher temperatures directly under the cabin ceiling
Temperature display for
bench sensor, multisen-
sor
Current value at bench sensor, multisensor
Display for humidity
multisensor
Current value at multisensor
Heating period limita-
tion
6 hrs (factory setting), 12 hrs, 18 hrs, infinite
Technical data

EN-16 Installation and Operating Instructions - EOS Compact DC/HC
EN Identification
2.5 Accessories
An additional output controller must be connected if the heater output is
above 10 kW or the phase load is above 16 A and an output of over 3 kW is
drawn at the vaporiser.
Output controller (LSG) Item no.
LSG 18 94.5730
LSG 18 H 94.5731
LSG 36 94.4392
LSG 36 H 94.5921
EmoTec L09 R 94.4998
Add-on modules Item no.
SBM remote start 94.5782
SBM-HOT 94.6800
SBM-ECO 94.6980
SBM-GLT-KNX 94.7078
SBM-GLT-Mod 94.7077
Sensors Item no.
Temperature sensor (beige) 94.7438
Additional safety temperature limiter housing (beige) 94.7443
Temperature sensor (anthracite) 94.7437
Additional safety temperature limiter housing (anthracite) 94.7444
Bench sensor (beige) 94.7439
Bench sensor (anthracite) 94.7440
Multisensor (beige) 94.7441
Multisensor (anthracite) 94.7442
Connecting cables for add-on modules Item no.
Connecting cable 6P6PC 10 m 94.5861
Connecting cable 6P6PC 25 m 94.4647
Connecting cable 6P6PC 50 m 94.4648

EOS Compact DC/HC - Installation and Operating Instructions EN-17
Identification
2.6 Intended use
In conjunction with a suitable sauna heater, the EOS Compact control unit
is intended to be used only to heat sauna cabins. It is suitable for cabins
used in private and commercial settings. The control unit must be
mounted on a wall.
The control unit is not suitable for outdoor use. It must be
operated only inside buildings and may not be exposed to
environmental conditions such as extreme humidity and
moisture or the possible formation of condensation or corro-
sive substances in the ambient air, as well as other weather
conditions. Similarly, excessive cold and extreme exposure to sunlight
must be prevented. Protect the unit accordingly if there is an increased risk
of mechanical damage.
Modular distributor Item no.
Modular distributor RJ 12 for connecting cable and
Sauna bus
2001.5298

EN-18 Installation and Operating Instructions - EOS Compact DC/HC
EN Installation
3Installation
3.1 Routing the lines
All lines should be routed before installing the control unit. The connec-
tions can be plugged in after installation, since the control unit’s front
panel can be removed.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route cable conduits separately.
Data lines must be routed and connected in such a way that they are not
openly accessible. They should be routed between the insulation and the
outer wall of the cabin. Cabin insulation must be installed in such a way
that the temperature in the area in which cables are routed
cannot exceed 65°C.
If the data lines are installed outside on the wall, they should be protected
by a cable duct.
Data line(s) routing

EOS Compact DC/HC - Installation and Operating Instructions EN-19
Installation
Additional lines
If an optional module is connected, a 6P6C line with RJ12 jack is required.
This line is available in various lengths.
See Connecting cables for add-on modules, EN-16.
3.2 Installation site
The control unit may be mounted only outside of the sauna cabin. Observe
the following guidelines.
WARNING
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
Do not mount the control unit in enclosed cabinets or wood
panelling.

EN-20 Installation and Operating Instructions - EOS Compact DC/HC
EN Installation
Proper and improper mounting of the control unit
This manual suits for next models
2
Table of contents
Other EOS Control Unit manuals

EOS
EOS ECON 09 User manual

EOS
EOS Saunabus Soundmodul Series User manual

EOS
EOS ECON D4 Parts list manual

EOS
EOS InfraStyle User manual

EOS
EOS Emotec D User manual

EOS
EOS EMOTEC DC 9000 User manual

EOS
EOS SBM-IR Modul User manual

EOS
EOS ECON H4 User guide

EOS
EOS InfraTec Premium User guide

EOS
EOS KUSATEK K-Tec User manual