EOS InfraStyle User manual

Druck-Nr.: 2902 5037
Stand: 25/19
EN
Made in Germany
26
Operation Mode
15:37
09:12
InfraStyle / InfraStyle i
Control unit for infrared cabins
Operating Instructions

2 Operating Instructions - InfraStyle / InfraStyle i
Documentation
EN
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
Copyright as per DIN ISO 16016:
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorisation, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-0
Fax +49 2775 82-431
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
Date Version Description
23 April 2019 01.00 First version
25/2019 01.10 Installation dimensions for InfraStyle i changed.

InfraStyle / InfraStyle i - Operating Instructions 3
Contents
Documentation......................................................................................................... 2
1 General safety instructions................................................................................. 5
1.1 Safety levels....................................................................................................... 5
1.2 Mounting and electrical installation ........................................................ 6
1.3 Operator instruction ...................................................................................... 7
1.4 Standards and regulations .......................................................................... 9
2 Identification ...........................................................................................................10
2.1 Control panels................................................................................................10
2.2 Intended use...................................................................................................11
3 Description of the units ......................................................................................12
3.1 Scope of delivery...........................................................................................12
3.2 Control panels ...............................................................................................14
3.3 Control panel circuit board .......................................................................15
3.4 Technical data ................................................................................................16
4Operation...................................................................................................................17
4.1 Switching the system on/off.....................................................................19
4.2 Switching the lighting on/off ...................................................................20
4.3 Configuration upon commissioning or after a reset .......................21
4.4 Adjusting the IR emitters............................................................................24
4.5 Basic settings .................................................................................................25
4.5.1 IR operating mode .......................................................................27
4.5.2 IR temperature ..............................................................................28
4.5.3 IR intensity ......................................................................................29
4.5.4 Automatic start time....................................................................30
4.5.5 Dimming the cabin lighting......................................................32
4.5.6 One-time heating period ..........................................................34
4.5.7 Recurring heating periods ........................................................36
4.5.8 Switching ECO mode on/off .....................................................41
4.6 Advanced settings .......................................................................................43
4.6.1 Screen saver ...................................................................................44
4.6.2 Standby mode................................................................................45
4.6.3 Operational lock/child lock .......................................................46
4.6.4 Heating period – auto stop ......................................................49
4.6.5 Operating data ..............................................................................51
4.6.6 Display brightness........................................................................55
4.6.7 Holiday cottage mode ...............................................................56
4.7 Troubleshooting ...........................................................................................59

4 Operating Instructions - InfraStyle / InfraStyle i
EN
5Servicesettings...................................................................................................... 60
5.1 Service level ................................................................................................... 61
5.1.1 Opening service settings........................................................... 62
5.1.2 Service/maintenance.................................................................. 63
5.1.3 Switching hysteresis for the IR temperature...................... 64
5.1.4 Reset function ............................................................................... 65
5.1.5 Temperature control................................................................... 66
5.1.6 Configuring the channel groups............................................ 68
5.1.7 Setting the ECO runtime ........................................................... 71
5.2 Defining the light source manually ...................................................... 72
5.3 Heating period limiter ............................................................................... 75
5.4 Updating firmware ...................................................................................... 76
6 General terms and conditions of service .................................................. 80
7Disposal..................................................................................................................... 83

InfraStyle / InfraStyle i - Operating Instructions 5
General safety instructions
General safety instructions
1.1 Safety levels
Safety instructions and important operating instructions are clas-
sified according to ANSI Z535.6. Please familiarise yourself with the
following terms and symbols:
DANGER
Danger
Indicates a hazardous situation which, if not avoided, will result in
death.
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.

6 Operating Instructions - InfraStyle / InfraStyle i
General safety instructions
EN
1.2 Mounting and electrical installation
These installation instructions are intended for qualified person-
nel familiar with the laws and regulations applicable to electrical
installations at the installation site. Observe the following general
safety instructions during assembly, setup and commissioning.
Risk to life and limb
and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
The electrical installation of the relay box and other electrical
systems or equipment with a fixed mains connection must only
be performed by a trained electrician from an authorised elec-
trical company.
Observe the stipulations in VDE 0100 part 701.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover must only be removed by a specialist.
Do not install the control panel, relay boxes or modules in en-
closed cabinets or wood panelling.
Fire hazard from
overheating
Infrared emitters and heating foils without overheat protection
can lead to overheating of the cabin and fire. Flammable parts
must not exceed a temperature of 140°C when the unit is operated
as intended or in the event of a malfunction.
Install only infrared emitters or heating foils that are designed
and installed in such a way that they do not pose a fire hazard
when the unit is operated as intended. Alternately, infrared
emitters or heating foils with overheat protection as per EN
60335-2-53 may be used.
Install a safety temperature limiter if needed.
Observe the manufacturer's safety and installation instructions
for infrared emitters and heating foils.
Observe the cabin manufacturer’s safety and installation in-
structions.

InfraStyle / InfraStyle i - Operating Instructions 7
General safety instructions
Damage due to
incorrect mounting
location
The control panel is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.
1.3 Operator instruction
The operator of the infrared or sauna cabin must be instructed in
the general safety instructions during commissioning. The opera-
tor must be given a copy of the instructions for use.
Risk of electric shock A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk also applies after work is com-
pleted.
The housing cover must only be removed by a specialist.
Repairs and installations must only be performed by a trained
specialist.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.
Risk of burns and
chemical burns
Touching hot parts may lead to skin burns and chemical burns of
the skin.
The operator must be familiar with the unit’s hot parts and be
able to identify them.
The operator must be familiar with the settings for the heating
period and understand how it is controlled.
Health risks Spending time in an infrared or sauna cabin can lead to serious
health risks or even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering an infrared or sauna cab-
in.

8 Operating Instructions - InfraStyle / InfraStyle i
General safety instructions
EN
Equipment damage
due to overuse
Excessive humidity in commercial infrared or sauna cabins can
lead to property damage.
In a commercial infrared or sauna cabin, the heating period
must be set so that it switches off automatically after a specific
period of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.
Operation by
children or persons
with reduced mental
capacity
Children and persons with reduced mental capacity can be a risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 should not operate the infrared cabin.
The settings for the heating period must only be used by chil-
dren under 8 years of age if they are supervised by an adult.
The infrared cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have already been instructed in its use and
understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.

InfraStyle / InfraStyle i - Operating Instructions 9
General safety instructions
1.4 Standards and regulations
The following standards, in their currently applicable versions, were
observed during design and construction.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.
Standard Title
DIN EN 60335-1 Household and similar electrical appliances – Part 1: General requirements
DIN EN 60335-2-30 Household and similar electrical appliances – safety – Part 2-30: Particular require-
ments for room heaters
DIN EN 60335-2-53 Household and similar electrical appliances – safety – Part 2-53: Particular require-
ments for sauna heating appliances and infrared cabins
DIN EN 60335-2-96 Household and similar electrical appliances – safety – Part 2-96: Particular require-
ments for heating equipment
DIN EN 55014-1 Electromagnetic compatibility – Requirements for household appliances, electric
tools and similar apparatus – Part 1: Emission
DIN EN 55014-2 Electromagnetic compatibility – Requirements for household appliances, electric
tools and similar apparatus – Part 2: Immunity

10 Operating Instructions - InfraStyle / InfraStyle i
Identification
EN
Identification
This chapter describes the control panel. For a detailed description of the
InfraStyle / InfraStyle i relay box, please refer to the installation instructions.
The relay box can be operated with one of the following control panels:
InfraStyle for mounting outside of the cabin, in black or white.
EmoStyle i for mounting in the cabin in black/maple or black/walnut
and in white/maple or white/walnut.
Software version R. 3.50 or higher must be installed in the control panel.
Update your software if it does not match the specifications above.
See:
4.6.5 Operating data, 51
5.4 Updating firmware, 76
2.1 Control panels
Nameplate
The nameplate is located on the inside of the front panel next to the circuit
board.
InfraStyle nameplate (example)
A Name and colour model C Manufacturing date
B Item number D Serial number
0000194707000
InfraStyle l schwarz Nussbaum
12.19
A
B
C D

InfraStyle / InfraStyle i - Operating Instructions 11
Identification
2.2 Intended use
InfraStyle / InfraStyle i are designed to operate infrared radiators and foils
(IR emitters). The control panels control the temperature of the cabin and
the intensity of the IR emitters.
The relay box and the control unit are designed to operate infrared radia-
tors and foils (IR emitters).
Neither device is suitable for outdoor use.
It must be operated only inside buildings and may not be exposed to envi-
ronmental conditions such as extreme humidity and moisture or the possi-
ble formation of condensation or corrosive substances in the ambient air,
as well as other weather conditions. Similarly, excessive cold and extreme
exposure to sunlight must be prevented. Protect the unit accordingly if
there is an increased risk of mechanical damage.
InfraStyle / InfraStyle i control panels
The InfraStyle / InfraStyle i control panels are suitable for private and com-
mercial use to control infrared cabins. They must only be mounted on a
wall.
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The infrared heating foils do not have an integrated temperature sensor
with overheat protection.
The control and sensor cable plugs are plugged in incorrectly.
The cabin addresses are programmed incorrectly.
The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated after technical or other modifications are made to
the module.
The unit is operated by children or persons with reduced mental capac-
ity or by persons who have not been thoroughly instructed in its use.
General safety instructions, 5
For more information, see the InfraStyle / InfraStyle i installation
instructions.

12 Operating Instructions - InfraStyle / InfraStyle i
Description of the units
EN
Description of the units
3.1 Scope of delivery
Scope of delivery – control panels
Check the scope of delivery for completeness. Ensure that you have
received the correct control panel:
InfraStyle for mounting outside of the cabin, either in or on the wall.
InfraStyle i for mounting inside the cabin in the wall.
A InfraStyle control panel with housing for mounting in
the wall
B InfraStyle i control panel with housing for mounting in
the wall
C Voltage regulator for InfraStyle i control panel
D Removal tool for front panel
E Installation and operating Instructions
F Control unit
09:12
26
Operation Mode
15:37
A
B
C
D E
F

InfraStyle / InfraStyle i - Operating Instructions 13
Description of the units
Accessories (optional)
Accessories Item no.
20-m connecting cable for temperature sensor 94.6281
50-m connecting cable for temperature sensor 94.6282
10-m connecting cable for control panel (RJ10/RJ14) 94.6802
25-m connecting cable for control panel (RJ10/RJ14) 94.6285
50-m connecting cable for control panel (RJ10/RJ14) 94.6968
100-m connecting cable for control panel (RJ10/RJ14) 94.6969
10-m connecting cable for sauna bus (RJ12/RJ12) 94.5861
25-m connecting cable for sauna bus (RJ12/RJ12) 94.4647
50-m connecting cable for sauna bus (RJ12/RJ12) 94.4648
IR module as installation add-on 94.6966
IR plug-in module with adapter cable 94.2046
IR plug-in module without adapter cable 94.4960
2.5-m connecting cable for IR plug-in module 94.4396
Set SBM ECO push button 94.6980
SBM-WCI-01 web app module 94.5987
SBM remote start 94.5782
SBM-FL75/150 coloured light module 94.5996, 94.6007
SBM-S BT sound module 94.5921
Infrared receiver for coloured light module and sound mod-
ule
94.6810
SBM-GLT-MOD HOME Modbus module 94.7077
SBM-GLT-KNX HOME KNX module 94.7078
Modular distributor RJ12 for connecting cable for control
panel and sauna bus
2001.5298

14 Operating Instructions - InfraStyle / InfraStyle i
Description of the units
EN
3.2 Control panels
InfraStyle diagram
The InfraStyle i control panel must only be mounted on the cabin's interior
wall. In addition, a voltage regulator is mounted outside of the cabin.
The InfraStyle control panel must only be mounted on the cabin’s exterior
wall. Two options are available:
Model for mounting in the wall (A): The housing is mounted in the wall.
Model for mounting on the wall (F): The housing is mounted on the
wall.
The connecting cable for the relay box is fed through the back of the hous-
ing of all control panels. The circuit board is affixed to the front panel.
A Housing for mounting in the wall
B Front panel with display
C Icons for program selection
D Slot at base for removal tool
E Opening for sauna bus connection
F Housing for mounting on the wall
G Top mounting hole
B
A
B
A
CC
F
D E G E

InfraStyle / InfraStyle i - Operating Instructions 15
Description of the units
3.3 Control panel circuit board
InfraStyle
InfraStyle circuit board connections
InfraStyle i
InfraStyle i circuit board connections
A Front panel – back
B Sauna bus connection
C Circuit board (diagram)
D Memory card (microSD) connection
A Front panel – back
B Insulation
C Circuit board (diagram)
D Sauna bus connection
E Voltage regulator connection
F Memory card (microSD) connection
B DA C
B FA EDC

16 Operating Instructions - InfraStyle / InfraStyle i
Description of the units
EN
3.4 Technical data
Relay box
Control panels
Ambient temperature -10°C to +40°C
Storage temperature -20°C to +60°C
Relay box housing Plastic
Dimensions (H x W x D) 240 x 230 x 70 mm
Weight Approx. 1.5 kg
Control panel EmoTec IR
Outputs/inputs 3 x RJ10 jack for sensor connection
2 x RJ12 jack for control panel and add-on modules
Input for power supply plug
Power supply 230 V 1N AC 50 Hz
Switching output Max. 3.5 kW
Circuits 3 separate circuits with total output of 3.5 kW, can be freely defined
- 2 of which individually dimmable
- 1 of which non-dimmable switching output
Temperature control Based on ambient temperature: 30-70°C
Based on personal preference using dimmable channels (zones)
Control characteristics Digital output control on circuits 1 and 2
Connection for lighting Min. 5 W (20 mA), resistive load, max. 100 W
Dimmable energy-saving bulbs, max. 35 W
Light source with conventional transformers, max. 60 VA Use only dimmable light
sources.
Sensor system Digital sensor for ambient temperature
Heating period limiter Up to 6 hrs/12 hrs/infinite
Ambient temperature InfraStyle: -10°C to +40°C
InfraStyle i: -10°C to +110°C
Storage temperature -20°C to +60°C
Housing Plastic
Control panel dimensions (W x H x
D)
InfraStyle: 127 x 130 x 25 mm, mounting depth approx. 20 mm
InfraStyle i: 142 x 202 x 42 mm, mounting depth approx. 37
mm
Voltage regulator for InfraStyle i Aluminium housing, approx. 75 x 40 x 30 mm (L/W/H), cable length 3 m
Front panel InfraStyle: Glass, InfraStyle i: Glass with wood inlay near icon buttons
Display TFT colour display 55 x 74 mm (3.5”diagonal)
Control panel outputs/inputs 1 x RJ10 jack for relay box
1 x connection for memory card (microSD memory card reader)
Operation 5 capacitive buttons for On/Off, lighting, selection and enter
Memory card reader microSD memory card reader

InfraStyle / InfraStyle i - Operating Instructions 17
Operation
Operation
All cabin settings are made at the control panel.
All functions must be configured to commission the system.
Add-on modules or accessories are detected after the unit is switched on
again and their corresponding icons appear in the sub-menus.
Control panels
A Front panel
B Display
C Status bar
D Function buttons
09:12
D
B
09:12
B
D
InfraStyle InfraStyle i
A
A
C
C

18 Operating Instructions - InfraStyle / InfraStyle i
Operation
EN
Controls
The following icons represent operational functions:
Selected icons are displayed inside a white frame. Once the selection is
confirmed, the frame turns green and the display now shows the
selected function.
When a value is entered, a line appears under the active place value.
Confirmed values are displayed in green.
Example – Entering values
The home screen (standby) appears after the display has not been touched
for 15 seconds.
Settings that have not been saved are lost.
Date and time are saved if the built-in battery is in working order. All
other settings are saved permanently.
Tap the icon buttons to select
and confirm functions.
Scroll back through functions.
On/off
Close sub-menu (only if heating
is switched off)
Scroll forward through func-
tions.
Light on/off Open selected function.
Confirm settings.
Code
Setting
Code
09:11
8200

InfraStyle / InfraStyle i - Operating Instructions 19
Operation
4.1 Switching the system on/off
You can switch the system on or off manually at any time. An on/off switch
is located on the left side of the relay box.
Switching the system on
1: Press and hold for approx. 3 seconds until the cabin is switched on.
The cabin is switched on with the pre-set parameters after the
countdown.
Switching the system off
1Press .
Position I:
Relay box is switched on.
The relay box is ready for operation in standby mode.
Position 0:
Relay box is completely switched off.
Parts of the circuit board are still energised.
Position II:
Cabin lighting is switched on, relay box is switched off.
Position for maintenance and cleaning.
09:12
3
2
1

20 Operating Instructions - InfraStyle / InfraStyle i
Operation
EN
4.2 Switching the lighting on/off
The light output is set to inductive load by default, to which resistive loads
may also be connected. If required, the light output can also be manually
set to capacitive loads.
Cabin lighting is not included in the scope of delivery. Observe the sepa-
rate installation instructions for lighting.
Lighting requirements
Lighting must be dimmable
Minimal output 5 W
Resistive loads max. 100 W
Dimmable energy-saving bulbs max. 35 W
Light sources with conventional transformers max. 60 VA
Dimmable LED bulbs max. 60 W
Lighting can be mounted anywhere, however not in the emitting range of
an IR emitter.
NOTICE
Material damage
Lighting and the control panel could become damaged if non-
dimmable light sources are installed. In this case, the warranty be-
comes void.
Do not install lighting in the emitting range of an IR emitter.
The lighting must conform to protection class IPX4 (splash-
proof) and be resistant to ambient temperatures.
Connect only dimmable light sources.
Setting the light output, see 5.2 Defining the light source manually, 72.
Other manuals for InfraStyle
1
This manual suits for next models
1
Table of contents
Other EOS Control Unit manuals

EOS
EOS Saunabus Soundmodul Series User manual

EOS
EOS ECON A1 User manual

EOS
EOS EMOTEC DC 9000 User manual

EOS
EOS EmoToych II AF User manual

EOS
EOS EmoStyle Di User manual

EOS
EOS EmoTouch 3 User manual

EOS
EOS EmoTouch 3 User manual

EOS
EOS EMOTEC L 09 Planning guide

EOS
EOS ECON D2 User manual

EOS
EOS ECON L09 User manual
Popular Control Unit manuals by other brands

Trinamic
Trinamic PD-1160 Getting started

Dyna-Flo
Dyna-Flo 570 Operation, Parts, and Instruction Manual

GEM
GEM 613 Installation, operating and maintenance instructions

Elektrogas
Elektrogas VML Series Technical manual

Leadshine
Leadshine 2CS3E Series user manual

Hacker
Hacker UAV Control Opto Pro Series manual