EOS InfraStyle User manual

Druck-Nr.: 2902 5036
Stand: 25/19
EN
Made in Germany
26
Operation Mode
15:37
09:12
InfraStyle / InfraStyle i
Control unit for infrared cabins
Installation Instructions for retailers

2 Installation Instructions - InfraStyle / InfraStyle i
Documentation
EN
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
Copyright as per DIN ISO 16016:
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorisation, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-0
Fax +49 2775 82-431
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
Date Version Description
23 April 2019 01.00 First version
25/2019 01.10 Installation dimensions for InfraStyle i changed.

InfraStyle / InfraStyle i - Installation Instructions 3
Contents
Documentation......................................................................................................... 2
1 General safety instructions................................................................................. 5
1.1 Safety levels....................................................................................................... 5
1.2 Mounting and electrical installation ........................................................ 6
1.3 Operator instruction ...................................................................................... 7
1.4 Standards and regulations ..........................................................................9
2 Identification ...........................................................................................................10
2.1 Unit information............................................................................................10
2.1.1 Relay box .........................................................................................10
2.1.2 InfraStyle/InfraStyle i control panels......................................11
2.2 Intended use...................................................................................................12
3 Description of the units ......................................................................................13
3.1 Scope of delivery...........................................................................................13
3.2 Overview of relay box..................................................................................16
3.3 Internal view of relay box...........................................................................17
3.4 Control panels ...............................................................................................18
3.5 Technical data ................................................................................................19
4 Installation................................................................................................................20
4.1 Power supply and data lines ....................................................................20
4.2 Installation work inside the cabin...........................................................22
4.2.1 Installing an infrared emitter....................................................23
4.2.2 Installing the temperature sensor ..........................................24
4.2.3 Installing cabin lighting..............................................................26
4.3 Relay box..........................................................................................................27
4.3.1 Guidelines........................................................................................27
4.3.2 Installing the relay box ...............................................................30
4.4 Control panels................................................................................................34
4.4.1 Guidelines........................................................................................34
4.4.2 Mounting the InfraStyle .............................................................38
4.4.3 Mounting InfraStyle i...................................................................45
5 Installation................................................................................................................50
5.1 Sample installation.......................................................................................51
5.2 Circuit board assignment...........................................................................53
5.2.1 Terminals .........................................................................................54
5.2.2 Emitter type – jumper JP1 and JP2.........................................54
5.2.3 Unit address – ADR DIP switch ................................................55
5.2.4 Channels – DIP switches IR1 to IR3.........................................55
5.3 Connection diagram ...................................................................................57

4 Installation Instructions - InfraStyle / InfraStyle i
EN
5.4 Connecting data lines................................................................................. 58
5.5 Connecting and configuring consumers............................................. 60
5.6 Configuring the relay box ........................................................................ 63
5.7 Closing the relay box housing................................................................. 65
6Commissioning..................................................................................................... 66
6.1 Operation basics........................................................................................... 67
6.2 Configuring during commissioning or after a reset ........................ 68
6.3 Configuring the IR control system ......................................................... 69
6.4 Configuring the channel groups ............................................................ 72
6.5 Adjusting the IR emitters........................................................................... 75
6.5.1 IR operating mode ...................................................................... 76
6.5.2 IR temperature ............................................................................. 77
6.5.3 IR intensity ..................................................................................... 78
6.5.4 Switching hysteresis for the IR temperature...................... 80
6.6 Defining the light source manually ...................................................... 83
6.7 Heating period limiter ............................................................................... 85
6.8 Troubleshooting .......................................................................................... 87
7 General terms and conditions of service .................................................. 88
8Disposal..................................................................................................................... 91

InfraStyle / InfraStyle i - Installation Instructions 5
General safety instructions
General safety instructions
1.1 Safety levels
Safety instructions and important operating instructions are clas-
sified according to ANSI Z535.6. Please familiarise yourself with the
following terms and symbols:
DANGER
Danger
Indicates a hazardous situation which, if not avoided, will result in
death.
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.

6 Installation Instructions - InfraStyle / InfraStyle i
General safety instructions
EN
1.2 Mounting and electrical installation
These installation instructions are intended for qualified person-
nel familiar with the laws and regulations applicable to electrical
installations at the installation site. Observe the following general
safety instructions during assembly, setup and commissioning.
Risk to life and limb
and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
The electrical installation of the relay box and other electrical
systems or equipment with a fixed mains connection must only
be performed by a trained electrician from an authorised elec-
trical company.
Observe the stipulations in VDE 0100 part 701.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover must only be removed by a specialist.
Do not install control panels, relay boxes and modules in en-
closed cabinets or wood panelling.
Fire hazard from
overheating
Infrared emitters and heating foils without overheat protection
can lead to overheating of the cabin and fire. Flammable parts
must not exceed a temperature of 140°C when the unit is operated
as intended or in the event of a malfunction.
Install only infrared emitters or heating foils that are designed
and installed in such a way that they do not pose a fire hazard
when the unit is operated as intended. Alternately, infrared
emitters or heating foils with overheat protection as per EN
60335-2-53 may be used.
Install a safety temperature limiter if needed.
Observe the manufacturer's safety and installation instructions
for infrared emitters and heating foils.
Observe the cabin manufacturer’s safety and installation in-
structions.

InfraStyle / InfraStyle i - Installation Instructions 7
General safety instructions
Damage due to
incorrect mounting
location
The control panel is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.
1.3 Operator instruction
The operator of the infrared or sauna cabin must be instructed in
the general safety instructions during commissioning. The opera-
tor must be given a copy of the instructions for use.
Risk of electric shock A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk also applies after work is com-
pleted.
The housing cover must only be removed by a specialist.
Repairs and installations must only be performed by a trained
specialist.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.
Risk of burns and
chemical burns
Touching hot parts may lead to skin burns and chemical burns of
the skin.
The operator must be familiar with the unit’s hot parts and be
able to identify them.
The operator must be familiar with the settings for the heating
period and understand how it is controlled.
Health risks Spending time in an infrared or sauna cabin can lead to serious
health risks or even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering an infrared or sauna cab-
in.

8 Installation Instructions - InfraStyle / InfraStyle i
General safety instructions
EN
Equipment damage
due to overuse
Excessive humidity in commercial infrared or sauna cabins can
lead to property damage.
In a commercial infrared or sauna cabin, the heating period
must be set so that it switches off automatically after a specific
period of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.
Operation by
children or persons
with reduced mental
capacity
Children and persons with reduced mental capacity can be a risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 should not operate the infrared cabin.
The settings for the heating period must only be used by chil-
dren under 8 years of age if they are supervised by an adult.
The infrared cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have already been instructed in its use and
understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.

InfraStyle / InfraStyle i - Installation Instructions 9
General safety instructions
1.4 Standards and regulations
The following standards, in their currently applicable versions, were
observed during design and construction.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.
Standard Title
DIN EN 60335-1 Household and similar electrical appliances – Part 1: General requirements
DIN EN 60335-2-30 Household and similar electrical appliances – safety – Part 2-30: Particular require-
ments for room heaters
DIN EN 60335-2-53 Household and similar electrical appliances – safety – Part 2-53: Particular require-
ments for sauna heating appliances and infrared cabins
DIN EN 60335-2-96 Household and similar electrical appliances – safety – Part 2-96: Particular require-
ments for heating equipment
DIN EN 55014-1 Electromagnetic compatibility – Requirements for household appliances, electric
tools and similar apparatus – Part 1: Emission
DIN EN 55014-2 Electromagnetic compatibility – Requirements for household appliances, electric
tools and similar apparatus – Part 2: Immunity

10 Installation Instructions - InfraStyle / InfraStyle i
Identification
EN
Identification
InfraStyle / InfraStyle i consist of a relay box and a control panel and are
used to operate the infrared cabin.
2.1 Unit information
2.1.1 Relay box
The nameplate is attached to the underside of the base of the housing.
Nameplate (example)
A Name F Country of origin
B Model G Manufacturer
C Item number H Manufacturing date
D Operating voltage I Serial number
E Maximum switching output (kW)
Infrarotsteuergerät
InfraStyle i schwarz Nussbaum
Art.-Nr. 94 7070 00
230 V 1N AC 50 Hz
Max. Schaltleistung 3,5 kW
Made in Germany
EOS-SAUNATECHNIK GmbH, 35759 Driedorf
S-No. 12.19 00001
IPX4
A
B
C
D
E
F
G
H I

InfraStyle / InfraStyle i - Installation Instructions 11
Identification
2.1.2 InfraStyle/InfraStyle i control panels
Software version R. 3.50 or higher must be installed in the InfraStyle and
InfraStyle i control panels.
The nameplate is located on the inside of the front panel next to the circuit
board.
InfraStyle nameplate (example)
Requirements for operation and storage
The InfraStyle control panel is only intended for installation outside the IR
cabin. The mounting location must meet the following climate condition
requirements:
Ambient temperature during operation -10°C to 40°C
Storage temperature -20°C to 60°C
The InfraStyle i control panel is only intended for installation in the IR
cabin. The mounting location must meet the following climate condition
requirements:
Ambient temperature during operation -10°C to 110°C
Storage temperature -20°C to 60°C
A Name and colour model C Manufacturing date
B Item number D Serial number
0000194707000
InfraStyle l schwarz Nussbaum
12.19
A
B
C D

12 Installation Instructions - InfraStyle / InfraStyle i
Identification
EN
2.2 Intended use
InfraStyle / InfraStyle i are designed to operate infrared emitters and heat-
ing foils in infrared cabins. The relay box and control panels are intended
only for mounting on the wall.
The SBM-IR module unit must be used in order to operate infrared heating
foils and infrared emitters as add-ons in a sauna cabin. The IR module is
operated together with the relay box for the sauna cabin.
InfraStyle / InfraStyle i is suitable for cabins used in private and commercial
settings.
The control panel is not suitable for outdoor use.
It must be operated only inside buildings and may not be exposed to envi-
ronmental conditions such as extreme humidity and moisture or the possi-
ble formation of condensation or corrosive substances in the ambient air,
as well as other weather conditions. Similarly, excessive cold and extreme
exposure to sunlight must be prevented. Protect the unit accordingly if
there is an increased risk of mechanical damage.
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The infrared heating foils do not have an integrated temperature sensor
with overheat protection.
The control and sensor cable plugs are plugged in incorrectly.
The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated after technical or other modifications are made to
the relay box.
The unit is operated by children or persons with reduced mental capac-
ity or by persons who have not been thoroughly instructed in its use.
General safety instructions, 5

InfraStyle / InfraStyle i - Installation Instructions 13
Description of the units
Description of the units
3.1 Scope of delivery
Relay box
The circuit board is enclosed in a plastic housing. The housing completely
encloses the circuit board and the electronics.
The following components are included in the relay box’s scope of delivery:
Relay box – scope of delivery
Check the scope of delivery for completeness prior to installation.
A
BE
F
G
C D
A Relay box with 2-piece front cover
B 5 bushings
C 3 wood screws 4 x 25 mm
D 5-m connecting cable with RJ14/RJ10 modular plug for
control panel
E Installation and operating Instructions
F Power supply with connection cables
G Temperature sensor including 5-m connecting cable
with RJ10 plug, housing, circuit board, 2 screws
4x40 mm

14 Installation Instructions - InfraStyle / InfraStyle i
Description of the units
EN
Control panels
The following components are included in the control panels’ scope of
delivery:
Scope of delivery – control panels
The InfraStyle control panel is supplied with one housing designed to
be mounted in the wall and one housing designed to be mounted on
the wall.
The InfraStyle i control panel is supplied with one housing designed to
be mounted in the wall.
09:12
26
Operation Mode
15:37
A
B
C
D E
A InfraStyle control panel with housing
B InfraStyle i control panel with housing
C Voltage regulator for InfraStyle i control panel
D Removal tool for front panel
E Installation and operating Instructions

InfraStyle / InfraStyle i - Installation Instructions 15
Description of the units
Accessories (optional)
Accessories Item no.
20-m connecting cable for temperature sensor 94.6281
50-m connecting cable for temperature sensor 94.6282
10-m connecting cable for control panel (RJ10/RJ14) 94.6802
25-m connecting cable for control panel (RJ10/RJ14) 94.6285
50-m connecting cable for control panel (RJ10/RJ14) 94.6968
100-m connecting cable for control panel (RJ10/RJ14) 94.6969
10-m connecting cable for sauna bus (RJ12/RJ12) 94.5861
25-m connecting cable for sauna bus (RJ12/RJ12) 94.4647
50-m connecting cable for sauna bus (RJ12/RJ12) 94.4648
IR module as installation add-on 94.6966
IR plug-in module with adapter cable 94.2046
IR plug-in module without adapter cable 94.4960
2.5-m connecting cable for IR plug-in module 94.4396
Set SBM ECO push button 94.6980
SBM-WCI-01 web app module 94.5987
SBM remote start 94.5782
SBM-FL75/150 coloured light module 94.5996, 94.6007
SBM-S BT sound module 94.5921
Infrared receiver for coloured light module and sound mod-
ule
94.6810
SBM-GLT-MOD HOME Modbus module 94.7077
SBM-GLT-KNX HOME KNX module 94.7078
Modular distributor RJ12 for connecting cable for control
panel and sauna bus
2001.5298

16 Installation Instructions - InfraStyle / InfraStyle i
Description of the units
EN
3.2 Overview of relay box
Housing
Relay box
Unit switch
The relay box is equipped with an on/off switch on the left side.
A Housing cover – top piece
B Housing
C Retaining screws for top piece
D Unit switch
E Retaining screws for bottom piece
F Housing cover – bottom piece
Position I:
Relay box is switched on (factory setting).
The relay box is ready for operation in standby mode.
Position 0:
Relay box is completely switched off.
Parts of the circuit board are still energised.
Position II:
Cabin lighting is switched on, relay box is switched off.
Position for maintenance and cleaning.
E
A
B
D
B
B
D
D
C

InfraStyle / InfraStyle i - Installation Instructions 17
Description of the units
3.3 Internal view of relay box
Housing base
The cables for mains supply and low voltage can be routed through the
holes on the back side or base of the housing.
Holes can be punched out at the predetermined points where needed.
For more information on the circuit board, see
5.2 Circuit board assignment, 53
A Top mounting hole
B Housing cover fixtures – top piece
C Unit switch
D Circuit board
E Housing cover fixtures – bottom piece
F Lower mounting holes
G Feed-throughs for cables with mains voltage
H Feed-throughs for cables with low voltage
B
A
G E
C
B
B
E
F
E H
D
F

18 Installation Instructions - InfraStyle / InfraStyle i
Description of the units
EN
3.4 Control panels
InfraStyle diagram
The InfraStyle i control panel must only be mounted on the cabin's interior
wall. In addition, a voltage regulator is mounted outside of the cabin.
The InfraStyle control panel must only be mounted on the cabin’s exterior
wall. Two options are available:
Model for mounting in the wall (A): The housing is mounted in the wall.
Model for mounting on the wall (F): The housing is mounted on the
wall.
The connecting cable for the relay box is fed through the back of the hous-
ing of all control panels. The circuit board is affixed to the front panel.
A Housing for mounting in the wall
B Front panel with display
C Icons for program selection
D Slot at base for removal tool
E Opening for sauna bus connection
F Housing for mounting on the wall
G Top mounting hole
B
A
B
A
CC
F
D E G E

InfraStyle / InfraStyle i - Installation Instructions 19
Description of the units
3.5 Technical data
Relay box
Control panels
Ambient temperature -10°C to +40°C
Storage temperature -20°C to +60°C
Relay box housing Plastic
Dimensions (H x W x D) 240 x 230 x 70 mm
Weight Approx. 1.5 kg
Control panel EmoTec IR
Outputs/inputs 3 x RJ10 jack for sensor connection
2 x RJ12 jack for control panel and add-on modules
Input for power supply plug
Power supply 230 V 1N AC 50 Hz
Switching output Max. 3.5 kW
Circuits 3 separate circuits with total output of 3.5 kW, can be freely defined
- 2 of which individually dimmable
- 1 of which non-dimmable switching output
Temperature control Based on ambient temperature: 30-70°C
Based on personal preference using dimmable channels (zones)
Control characteristics Digital output control on circuits 1 and 2
Connection for lighting Min. 5 W (20 mA), resistive load, max. 100 W
Dimmable energy-saving bulbs, max. 35 W
Light source with conventional transformers, max. 60 VA Use only dimmable light
sources.
Sensor system Digital sensor for ambient temperature
Heating period limiter Up to 6 hrs/12 hrs/infinite
Ambient temperature InfraStyle: -10°C to +40°C
InfraStyle i: -10°C to +110°C
Storage temperature -20°C to +60°C
Housing Plastic
Control panel dimensions (W x H x
D)
InfraStyle: 127 x 130 x 25 mm, mounting depth approx. 20 mm
InfraStyle i: 142 x 202 x 42 mm, mounting depth approx. 37
mm
Voltage regulator for InfraStyle i Aluminium housing, approx. 75 x 40 x 30 mm (L/W/H), cable length 3 m
Front panel InfraStyle: Glass, InfraStyle i: Glass with wood inlay near icon buttons
Display TFT colour display 55 x 74 mm (3.5” diagonal)
Control panel outputs/inputs 1 x RJ10 jack for relay box
1 x connection for memory card (microSD memory card reader)
Operation 5 capacitive buttons for On/Off, lighting, selection and enter
Memory card reader microSD memory card reader

20 Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
Installation
This chapter describes how to install the relay box and the control panel.
NOTICE
Damage due to incorrect mounting location
The control panel is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.
4.1 Power supply and data lines
All electrical installations and all connecting lines routed inside the cabin
must be suitable for an ambient temperature of at least 70°C in infrared-
only cabins.
All lines must be routed in such a way that they are well-protected, e.g. in a
cable conduit.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route separate cable conduits.
Other manuals for InfraStyle
1
This manual suits for next models
2
Table of contents
Other EOS Control Unit manuals

EOS
EOS Emotec D User manual

EOS
EOS KUSATEK K-Tec User manual

EOS
EOS SBM App Module Manual instruction

EOS
EOS ECON D2 User manual

EOS
EOS EmoTouch 3 User manual

EOS
EOS ECON D4 Parts list manual

EOS
EOS ECON H4 User guide

EOS
EOS ECON L09 User manual

EOS
EOS EMOTEC L 09 Relay User manual

EOS
EOS EmoToych II AF User manual
Popular Control Unit manuals by other brands

Trinamic
Trinamic PD-1160 Getting started

Dyna-Flo
Dyna-Flo 570 Operation, Parts, and Instruction Manual

GEM
GEM 613 Installation, operating and maintenance instructions

Elektrogas
Elektrogas VML Series Technical manual

Leadshine
Leadshine 2CS3E Series user manual

Hacker
Hacker UAV Control Opto Pro Series manual