EOS Compact D18 User manual

Druck-Nr.: 2902 5179
Stand: 28.2022
EN
Made in Germany
EOS Compact D18/H18
Control Unit for Sauna Cabins
Installation and Operating Instructions

EN-2 Installation and Operating Instructions - EOS Compact D18/H18
EN Documentation
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorisation, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-514
Fax +49 2775 82-431
Email ser[email protected]
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
≤ ≥ Less than or equal to, greater than or equal to
Date Version Description
30/5/2022 01.00 First version

EOS Compact D18/H18 - Installation and Operating Instructions EN-3
Contents
Documentation ..................................................................................................EN-2
1 General safety instructions ..........................................................................EN-6
1.1 Mounting and electrical installation .................................................EN-6
1.2 Operator instruction................................................................................EN-8
1.3 Safety levels............................................................................................. EN-11
1.4 Standards and regulations................................................................. EN-11
2 Identification.................................................................................................... EN-12
2.1 Scope of delivery ................................................................................... EN-12
2.2 Nameplate ............................................................................................... EN-13
2.3 Sensors ...................................................................................................... EN-13
2.4 Technical data......................................................................................... EN-15
2.5 Accessories .............................................................................................. EN-16
2.6 Intended use ........................................................................................... EN-17
3 Installation ........................................................................................................ EN-19
3.1 Routing the lines.................................................................................... EN-19
3.2 Installation site ....................................................................................... EN-20
3.3 Mounting the control unit ................................................................. EN-22
3.4 Mounting the heater sensor.............................................................. EN-30
3.5 Mounting the multisensor (optional) ............................................EN-34
3.6 Mounting the bench sensor (optional) .........................................EN-36
3.7 Mounting the cabin lighting.............................................................EN-36
3.8 Mounting the fan ..................................................................................EN-37
4 Electrical installation.................................................................................... EN-38
4.1 Circuit board assignment for EOS Compact H18.......................EN-41
4.2 Circuit board assignment for EOS Compact D18....................... EN-42
4.3 Connecting the sensor cables ..........................................................EN-43
4.4 Connecting the consumer lines.......................................................EN-45
4.5 Connecting optional modules.......................................................... EN-50
4.6 Potential-free contact .......................................................................... EN-53
4.7 Security settings .................................................................................... EN-54
4.8 Mains connection.................................................................................. EN-56

EN-4 Installation and Operating Instructions - EOS Compact D18/H18
EN
5 Commissioning................................................................................................EN-57
5.1 Setup ..........................................................................................................EN-57
5.2 Defining the light source ....................................................................EN-60
5.3 PFC function ............................................................................................EN-61
5.4 Fan function.............................................................................................EN-62
5.5 Checking for proper installation of the vaporiser......................EN-63
6 Operation ...........................................................................................................EN-64
6.1 Controls .....................................................................................................EN-64
6.1.1 Rocker switch (on, off, light only).....................................EN-64
6.1.2 Buttons and screen ...............................................................EN-65
6.1.3 Screen saver and sleep mode ...........................................EN-65
6.1.4 Instructions for operation...................................................EN-66
6.2 Main menu ...............................................................................................EN-67
6.3 Status bar..................................................................................................EN-68
6.4 Keypad lock..............................................................................................EN-69
6.5 Display settings ......................................................................................EN-69
6.5.1 Time............................................................................................EN-69
6.5.2 Display brightness ................................................................EN-69
6.6 Setup/reset...............................................................................................EN-70
6.7 Sauna controls ........................................................................................EN-70
6.7.1 Switching the sauna heater on/off..................................EN-70
6.7.2 Dimming or switching the light on/off..........................EN-71
6.7.3 Selecting Finnish/Bi-O mode.............................................EN-72
6.7.4 Temperature............................................................................EN-72
6.7.5 Setting the humidity for Bi-O mode ...............................EN-73
6.7.6 Heating period – auto stop................................................EN-75
6.7.7 Timer ..........................................................................................EN-76
6.7.8 Profiles .......................................................................................EN-77
6.7.9 HOT mode (intense heating).............................................EN-78
6.7.10 ECO mode (temperature decrease) ................................EN-78
6.7.11 Retrieving temperature/humidity values .....................EN-79
6.7.12 Switching the PFC on/off manually ................................EN-79
6.7.13 Switching the fan on/off manually..................................EN-80

EOS Compact D18/H18 - Installation and Operating Instructions EN-5
6.8 Advanced settings ................................................................................ EN-81
6.8.1 Runtime for ECO mode .......................................................EN-81
6.8.2 Runtime for HOT mode....................................................... EN-82
6.8.3 Modes – holiday cottage, holiday resort, remote...... EN-82
6.8.4 Temperature control............................................................ EN-84
6.8.5 Remote control ...................................................................... EN-85
7 Maintenance..................................................................................................... EN-86
7.1 Cleaning.................................................................................................... EN-86
7.2 Maintenance ........................................................................................... EN-86
7.3 Display of software and serial number.......................................... EN-87
7.4 Display of contact information......................................................... EN-87
7.5 Display of next service date............................................................... EN-88
8 Troubleshooting ............................................................................................ EN-89
8.1 Error messages ....................................................................................... EN-89
8.2 Malfunction ............................................................................................. EN-91
9 General terms and conditions of service ........................................... EN-92
10 Disposal .............................................................................................................. EN-95

EN-6 Installation and Operating Instructions - EOS Compact D18/H18
EN General safety instructions
1 General safety instructions
1.1 Mounting and electrical installation
These installation instructions are intended for qualified per-
sonnel familiar with the laws and regulations applicable to
electrical installations at the installation site. Observe the fol-
lowing general safety instructions during mounting, configu-
ration and commissioning of the product.
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk remains also after
completion of the installation work.
The electrical installation of the control unit and other electrical
systems or equipment with a fixed mains connection may be
performed only by a trained electrician from an authorised elec-
trical company.
Ensure compliance with the applicable standards and regula-
tions for electrical installation.
The system must be completely disconnected from the mains
supply before commencing installation and repair work.
The housing cover must only be removed by a trained special-
ist.

EOS Compact D18/H18 - Installation and Operating Instructions EN-7
General safety instructions
Fire hazard from overheating
Insufficient ventilation can lead to device overheating and fire.
Do not install control panels, relay boxes and modules in en-
closed cabinets or wood panelling.
Observe the sauna heater manufacturer’s safety and installa-
tion instructions.
Observe the cabin manufacturer’s safety and installation in-
structions.
Touchable glass surfaces on the outside of the cabin must not
exceed 76°C. Provide a protective system if needed.
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and in the sensors.
The control panel and sensors should not be installed in a cor-
rosive or heavy saline atmosphere.
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.

EN-8 Installation and Operating Instructions - EOS Compact D18/H18
EN General safety instructions
1.2 Operator instruction
The operator of the sauna cabin must be instructed in the general safety
instructions during commissioning. The operator must be given a copy of
the operating instructions.
The operator must make the end user aware of safety instructions that are
relevant to the end user.
The operator must be familiar with the settings for the heating period and
understand how it is controlled.
Fire hazard
Objects left on the heater and/or directly in front of an
IR emitter can catch fire and lead to fires.
Do not place objects on the heater and/or directly
in front of an IR emitter.
Fill the rock store as directed.
Inspect the sauna cabin prior to each commissioning.
If you switch on the heater using pre-set timers or a remote con-
trol, attach a protective cover to the heater or install a suitable
safety system.
When using control units with a remote control* option (see
EN 60335-1), protection from switching on a covered sauna
heater is required.
* Remote control = setting up, controlling and/or regulating a
device with a command that can be given outside of the visual
range of a device, whereby the transmission media such as tel-
ecommunication, audio engineering or bus systems are used;
also included are pre-set timers and weekly timers.

EOS Compact D18/H18 - Installation and Operating Instructions EN-9
General safety instructions
Risk of electric shock
A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk remains also after work is com-
pleted.
The housing cover must only be removed by a trained special-
ist.
Repairs and installations must only be performed by a trained
specialist.
The system must be completely disconnected from the mains
supply before commencing repair work.
Use only original spare parts from the manufacturer.
Health risks
Spending time in an infrared or sauna cabin can lead to serious
health risks or even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering an infrared or sauna cab-
in.
Equipment damage due to overuse
Excessive humidity in commercial infrared or sauna cabins can
lead to property damage.
In a commercial infrared or sauna cabin, the heating period
must be set so that it switches off automatically after a specific
period of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.

EN-10 Installation and Operating Instructions - EOS Compact D18/H18
EN General safety instructions
Operation by children or persons with reduced mental
capacity
Children and persons with reduced mental capacity can put them-
selves at risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 years of age should not operate the sauna
cabin.
The settings for the heating time must only be changed by chil-
dren under 8 years of age if they are supervised by an adult.
The sauna cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have been previously instructed in its use
and understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.

EOS Compact D18/H18 - Installation and Operating Instructions EN-11
General safety instructions
1.3 Safety levels
Safety instructions and important operating instructions are classified.
Please familiarise yourself with the following terms and symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.
1.4 Standards and regulations
For an overview of the standards that were observed during design and
construction of the sauna heaters, please refer to the individual product’s
technical data sheet that can be downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.

EN-12 Installation and Operating Instructions - EOS Compact D18/H18
EN Identification
2 Identification
The scope of delivery of the EOS Compact control unit includes a control
unit, a heater sensor with connecting cables for the sensor, and safety tem-
perature limiter. The unit is used to operate a sauna cabin.
EOS Compact is available in two models:
EOS Compact D18: Finnish sauna mode
EOS Compact H18: Finnish or steamy hot air bath mode
This documentation describes both models.
2.1 Scope of delivery
Scope of delivery
Check the scope of delivery for completeness prior to installation.
A EOS Compact control unit
B Installation and Operating Instruc-
tions
C 2 screws to attach the heater sen-
sor (3 x 25 mm)
D Heater sensor with safety tempera-
ture limiter
E Sensor cable (2 m) and safety temper-
ature limiter (2 m)
F Replacement safety temperature lim-
iter (in control unit housing)
G 4 screws to attach the control unit
(4 x 25 mm)
H Bushings: 8 large, 2 small
I Screwdriver 2 mm
B
E
A D
F
G
HI
C

EOS Compact D18/H18 - Installation and Operating Instructions EN-13
Identification
2.2 Nameplate
The nameplate is attached to the top of the control panel housing cover.
Nameplate (example)
2.3 Sensors
Heater sensor
The temperature/humidity in the sauna cabin is set via the control unit. The
set values are checked by the sensor. The heater sensor controls the tem-
perature in the sauna cabin. The heater sensor has a safety temperature
limiter, which ensures that the temperature does not exceed 140°C.
Internal view of heater sensor
A Name
B Model
C Item number
D Operating voltage
E Switching output
F Country of origin
G Manufacturer
H Manufacturing date
I Serial number
A Temperature sensor B Safety temperature limiter
Saunasteuergerät / Control unit
Type EOS Compact D/H 18
Art. Nr. 94 XXXX 00
400 V 3N ~ 50 Hz
Max. Schaltleistung 18 kW
Made in Germany
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 31.22 00001
IPX4
A
B
C
D
E
F
G
HI
A B

EN-14 Installation and Operating Instructions - EOS Compact D18/H18
EN Identification
Bench sensor (optional, EOS Compact D18/H18)
You can improve heat distribution in very large saunas where air circulation
is a challenge by using an additional bench sensor.
If a bench sensor is installed, it assumes control of the temperature. How-
ever, the heater sensor does not control the cabin temperature, rather it
limits the temperature within the maximum permissible range via the
heater. Exceeding the permissible temperature range would trigger the
safety temperature limiter.
If the bench sensor fails, the heater sensor regulates the temperature.
Multisensor (optional, for EOS Compact H18 only)
The multisensor is a special sensor that can function as a humidity sensor
and a temperature sensor (bench sensor). The multisensor checks either
the humidity or the temperature in the sauna cabin. In Bi-O mode, the mul-
tisensor controls the relative air humidity in %. At the same time, the con-
trol unit attempts to keep the set humidity as precisely as possible.
If the sauna is in Finnish mode, the temperature is measured and con-
trolled, not the humidity.
The heater sensor continues to monitor the temperature behaviour and
only intervenes for safety reasons when it is necessary prevent overheating
via the heater.
If the multisensor fails, the heater sensor regulates the temperature.

EOS Compact D18/H18 - Installation and Operating Instructions EN-15
Identification
2.4 Technical data
Technical data
Ambient temperature -10°C to +40°C
Storage temperature -20°C to +70°C
Housing Plastic
Dimensions (H x W x D) 220 x 255 x 90 mm
Weight Approx. 1.2 kg
Power supply 400 V 3N AC 50 Hz
Switching output 18 kW (3 kW vaporiser)
Protection class IPx4 splash-proof
Temperature control
range
Finnish sauna mode: 30–115°C
Steamy hot air bath (Bi-O): 30–70°C
Humidity control
(H18 only)
Without humidity sensor: Cycle (1–100) in proportion
to time for active humidity mode
With humidity sensor: according to relative air humid-
ity in %
Water level monitoring
(H18 only)
Detects water shortage with automatic switch off after
3 minutes (only with compatible sauna heater)
Connection for lighting Min. 5 W (20 mA)
Resistive load: max. 100 W
Energy-saving bulbs, max. 35 W
Light source with conventional transformers, max.
60 VA.
Fan and light connections are protected by a joint 2A F
fuse.
Light dimming Possible for light sources with phase-cut dimmer.
Resistive loads (e.g. light bulbs) and inductive loads
(e.g. LED light source) are suitable. Capacitive loads
(phase control) are not supported.
Connection for fan Max. 100 W, single- and double-phase fans
Sensor system
(Temperature)
KTY sensor with
safety temperature limiter 139°C
Temperature display for
heater sensor
Current value at heater sensor minus 7 K to offset
higher temperatures directly under the cabin ceiling

EN-16 Installation and Operating Instructions - EOS Compact D18/H18
EN Identification
2.5 Accessories
An additional power extension unit must be connected if the heater out-
put is above 18 kW or the phase load is above 25 A and an output of over
3 kW is drawn at the vaporiser.
Temperature display for
bench sensor, multisen-
sor
Current value at bench sensor, multisensor
Display for humidity
multisensor
Current value at multisensor
Heating period limita-
tion
6 hrs (factory setting), 12 hrs, 18 hrs, infinite
Power extension units (LSG) Item no.
LSG 18 94.5730
LSG 18 H 94.5731
LSG 36 94.4392
LSG 36 H 94.4230
LSG10 CW (white) 94.7803
LSG 10 CA (anthracite) 94.7802
Add-on modules Item no.
SBM remote start 94.5782
SBM-HOT 94.6800
SBM-ECO 94.6980
SBM-GLT-KNX 94.7078
SBM-GLT-Mod 94.7077
AquaDisp 94.6904
EOSafe Depends on model
Technical data

EOS Compact D18/H18 - Installation and Operating Instructions EN-17
Identification
2.6 Intended use
In conjunction with a suitable sauna heater, the EOS Compact control unit
is intended to be used only to heat sauna cabins. It is suitable for residen-
tial and commercial sauna cabins. The control unit must be mounted on a
wall.
The control unit is not suitable for outdoor use. It must be
operated only inside buildings and may not be exposed to
environmental conditions such as extreme humidity and
moisture or the possible formation of condensation or corro-
sive substances in the ambient air, as well as other weather
conditions. Similarly, excessive cold and extreme exposure to sunlight
must be prevented. Protect the unit accordingly if there is an increased risk
of mechanical damage.
Sensors
Item no.
beige anthracite
Temperature sensor 94.7438 94.7437
Additional safety temperature limiter
housing (beige)
94.7443 94.7444
Bench sensor 94.7439 94.7440
Multisensor 94.7441 94.7442
Connecting cables for add-on modules Item no.
Connecting cable 6P6PC 10 m 94.5861
Connecting cable 6P6PC 25 m 94.4647
Connecting cable 6P6PC 50 m 94.4648
Modular distributor Item no.
Modular distributor RJ 12 for connecting cable and
Sauna bus
2001.5298

EN-18 Installation and Operating Instructions - EOS Compact D18/H18
EN Identification
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The control and sensor cable plugs are plugged in incorrectly.
The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated after technical or other modifications are made to
the relay box.
The unit is operated by children under 8 years of age.
The unit is operated by children 8 years of age or older, or persons with
reduced mental capacity who have not been thoroughly instructed in
its use.
The manufacturer is not liable for unauthorised modifications made to the
equipment and damages resulting from these modifications. The person
modifying the equipment alone shall bear the associated risk.

EOS Compact D18/H18 - Installation and Operating Instructions EN-19
Installation
3 Installation
3.1 Routing the lines
All lines should be routed before installing the control unit. The connec-
tions can be plugged in after installation, since the control unit’s front
panel can be removed.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Lay data and mains leads in separate cable channels.
Data lines must be routed and connected in such a way that they are not
openly accessible. They should be routed between the insulation and the
outer wall of the cabin. Cabin insulation must be installed in such a way
that the temperature in the area in which cables are routed
cannot exceed 65°C.
If the data lines are installed outside on the wall, they should be protected
by a cable duct.
Data line(s) routing

EN-20 Installation and Operating Instructions - EOS Compact D18/H18
EN Installation
Additional lines
If an optional module is connected, a 6P6C line with RJ12 jack is required.
This line is available in various lengths.
See Connecting cables for add-on modules, EN-17.
3.2 Installation site
The control unit may be mounted only outside of the sauna cabin. Observe
the following guidelines.
WARNING
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk remains also after
completion of the installation work.
Do not mount the control unit in enclosed cabinets or wood
panelling.
Proper and improper mounting of the control unit
This manual suits for next models
1
Table of contents
Other EOS Control Unit manuals

EOS
EOS InfraStyle User manual

EOS
EOS EMOTEC DC 9000 User manual

EOS
EOS EmoTec LSG 09R Planning guide

EOS
EOS ECON H3 User guide

EOS
EOS ECON A2 User manual

EOS
EOS Saunabus Soundmodul Series User manual

EOS
EOS ECON A1 User manual

EOS
EOS EMOTEC L 09 Relay User manual

EOS
EOS SBM-IR Modul User manual

EOS
EOS InfraTec Premium User guide
Popular Control Unit manuals by other brands

Trinamic
Trinamic PD-1160 Getting started

Dyna-Flo
Dyna-Flo 570 Operation, Parts, and Instruction Manual

GEM
GEM 613 Installation, operating and maintenance instructions

Elektrogas
Elektrogas VML Series Technical manual

Leadshine
Leadshine 2CS3E Series user manual

Hacker
Hacker UAV Control Opto Pro Series manual