Page 1
E
X77900
23/04/2018
W70G
-
E
X77900Q
4
Copyright 201
8
EtherWAN Systems, Inc.
All Rights Reserved
EX77900 Series Hardened Managed Ethernet Switch
Installation Guide
1Unpacking
Open the carton and unpack the items. Your package should include:
ØEX77900 hardened managed Ethernet switch
Ø2 Mounting brackets
Ø12 Mounting screws
Ø1 Console cable
Ø2 Power cables (if no terminal block)
ØQuick install guide
If any items are missing or damaged, notify your EtherWAN
representative. If possible, save the carton and packing material in case
you need to ship or store the switch in the future. The full product
manual can be downloaded from:
https://www.etherwan.com/support/product/ex77900-series
Power Input Interface (Z)
B12-24VDC (Terminal Block)
T±48VDC (Terminal Block)
W100-240VAC (Terminal Block)
C100-240VAC (AC Inlet)
TR ±48VDC Redundant (Terminal Block)
WR 100-240VAC Redundant(Terminal Block)
CR 100-240VAC Redundant (AC Inlet)
2What Else You Need
ØCategory 5e or better cable for RJ-45 ports
ØAppropriate fiber cables for fiber ports
ØAppropriate SFP cable and modules for SFP ports
ØPersonal computer with a DB-9 male interface (if switch is to be
managed through console port)
3Select a Location
ØInstallation: Rack-mount. Use the enclosed screws and brackets to
mount the switch in an open or enclosed 19” rack.
ØIdentify a power source within 6 feet (1.8 meters).
ØChoose a dry area with ambient temperature between -40 and 75ºC (-
40 and 167ºF).
ØKeep away from heat sources, sunlight, warm air exhausts, hot-air
vents, and heaters.
ØBe sure there is adequate airflow.
4Connect to the Data Ports
The EX77900 has the following ports:
Ø24 10/100/1000 Mbps copper ports
Ø8 SFP slots shared with ports 17 – 24 supporting 100Mbps or 1Gbps
Ø4 SFP+ slots, supporting 10Gbps or 1Gbps
10/100/1000BASE-TX Ports
Ports 1 to 16 are gigabit copper ports and can be connected to routers,
other switches, or end devices. Use category 5e or higher UTP/STP cable.
1 Gbps Combo/SFP Ports
Ports 17 – 24 are combo ports, and have two physical interfaces for each
port. These ports can be used as either 10/100/1000BASE-TX on the left
section or 1000BASE-FX on the right section. These ports operate in
“either/or” fashion, i.e., connecting to fiber port 17 will render copper
port 17 inoperable.
SFP+ Slots
SFP transceivers can be installed directly into right-side ports 17 – 24 and
SFP ports 1 – 4. Ensure that the same type of transceiver is used at both
ends of the link and that the correct type of fiber cable is used.
5Connect Power
Terminal Block
If your EX77900 comes with power cables, connect the cables into the
power modules at the back of the switch. If your switch comes with a
terminal block (no cable), then connect the switch to a suitable power
supply using 12 to 24 AWG wire.
Redundant power supply is supported. However, only one power input is
required to operate the switch.
Relay Output Alarm
The switch provides relay output contacts for signaling of a user-defined
power or port failure. The relay output can be connected to an alarm
signaling device.
Normal state: 3 & 2 open, 2 & 1 closed
Alarm state: 3 & 2 closed, 2 & 1 open
Power-Up Sequence
When the switch is powered up:
ØAll Link/ACT LEDs blink momentarily.
ØThe Power 1, 2 LEDs light up and stay lit.
ØLEDs for every port connected to a device will flash, as the switch
conducts a brief Power On Self-Test (POST).
Ø
6Front Panel LEDs
LED Panel Layout
Green LED ON = network connection established
FLASHING = Port sending or receiving data
Page 2
E
X77900
23/04/2018 W70G-EX77900Q4
EX77900 Series Hardened Managed Ethernet Switch
Installation Guid
e
Copyright 201
8
EtherWAN Systems, Inc.
All Rights Reserved
7Console Configuration
ØConnect to the switch console by connecting the DB-9 cable to the
console port of the switch and to the serial port of the computer
running a terminal emulation application (such as Hyperterminal or
Putty).
ØConfiguration settings of the terminal-emulation program: Baud rate:
115,200bps, Data bits: 8, Parity: none, Stop bit: 1, Flow control: none.
ØThe default login name is “root,” no password.
8Web Configuration
ØLog in to the switch by launching a web browser and entering
192.168.1.10 in the address bar.
ØEnter the default login ID: root (no password) and click “Login.”
9Copy Configuration to USB
The USB port can be used to save the running switch configuration to a
(FAT32) USB storage device. Plug the device into the USB port, and use
the “Save Configuration” command in the web interface, or “copy
running-config startup-config” in the CLI.
10 Other Information
The power cord must be connected to a properly earth grounded outlet.
Rack Mount Instructions - The following or similar rack-mount instructions
are included with the installation instructions:
(A) Elevated Operating Ambient - If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma)
specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation of the
equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven
mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection
of the equipment to the supply circuit and the effect that overloading of
the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply
connections other than direct connections to the branch circuit (e.g. use
of power strips).
ØThe socket-outlet shall be installed near the equipment and shall be
easily accessible.
ØDo not disable the power cord grounding plug. The grounding plug is
an important safety feature.
ØPlug the power cord into a grounded (earthed) electrical outlet that
is easily accessible at all times.
This equipment is intended to be used in a restricted access location and
be used by a qualified person.
Caution:
This equipment shall be used with all power supplies connected
simultaneously.
Hazardous voltages may occur within this unit when connected to all
power supplies. Prevent access to hazardous voltages by disconnecting
this equipment from all power supplies.
This equipment must be connected to Protective earthing (PE) to AC
mains ground. The protective earthing conductor shall be minimum 18
AWG and having green-and-yellow insulation. The thread diameter of
screw type terminal shall be minimum 3.5mm.
This equipment is not suitable for use in locations where children are
likely to be present.
The power cord shall be IEC 60227 certified, rated 0.75 mm2 x 3C or UL
recognized minimum 18AWG
Mains circuit connection:
DC Terminal Block
AC Terminal Block
All power connection wiring by a qualified electrician in accordance with
National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code,
Part I, CSA C22.1. An IEC certified or UL listed single-phase type circuit-
breaker, rated maximum 20A, shall be installed between mains circuit
and equipment.
Thumbscrews should be tightened with a tool after both initial
installation subsequent access to the panel.
Caution:
This equipment has a connection between the earthed conductor of the
DC supply circuit and the earthing conductor. All of the following
installation conditions must be met.
ØThis equipment shall be connected directly to the DC supply system
earthing electrode conductor or to a bonding jumper from an earthing
terminal bar or bus to which the DC supply system earthing electrode
is connected.
ØThis equipment shall be located in the same immediate area (such as
adjacent cabinets) as any other equipment that has a connection
between the earthed conductor of the same DC supply circuit and the
earthing conductor, and also the point of earthing of the DC system.
The DC system shall not be earthed elsewhere.
ØThe DC supply source is to be located within the same premises as
this equipment.
ØThere shall be no switching or disconnecting devices in the earthed
circuit conductor between the DC source and the point of connection
on the earthing electrode conductor.
Note: This equipment must use UL recognized Laser Class 1 optical
transceiver.
This equipment is intended to be used in a restricted access location and
be used by a qualified person.
This equipment is not suitable for use in locations where children are
likely to be present.
Protective
Earthing (PE)

Other EtherWAN Switch manuals

EtherWAN EX62000 User manual

EtherWAN

EtherWAN EX62000 User manual

EtherWAN EX17082A User manual

EtherWAN

EtherWAN EX17082A User manual

EtherWAN EX26262F Series User manual

EtherWAN

EtherWAN EX26262F Series User manual

EtherWAN EX19164A User manual

EtherWAN

EtherWAN EX19164A User manual

EtherWAN EX42300 series User manual

EtherWAN

EtherWAN EX42300 series User manual

EtherWAN EX87000 Series User manual

EtherWAN

EtherWAN EX87000 Series User manual

EtherWAN EG97000 Series User manual

EtherWAN

EtherWAN EG97000 Series User manual

EtherWAN EX17242 User manual

EtherWAN

EtherWAN EX17242 User manual

EtherWAN EX16926 User manual

EtherWAN

EtherWAN EX16926 User manual

EtherWAN SmartE Series User manual

EtherWAN

EtherWAN SmartE Series User manual

EtherWAN EX17908 Series User manual

EtherWAN

EtherWAN EX17908 Series User manual

EtherWAN ER59000 Series User manual

EtherWAN

EtherWAN ER59000 Series User manual

EtherWAN EX17016 User manual

EtherWAN

EtherWAN EX17016 User manual

EtherWAN EX26484 User manual

EtherWAN

EtherWAN EX26484 User manual

EtherWAN EX78600 User manual

EtherWAN

EtherWAN EX78600 User manual

EtherWAN EX19164 User manual

EtherWAN

EtherWAN EX19164 User manual

EtherWAN EX32905 Series User manual

EtherWAN

EtherWAN EX32905 Series User manual

EtherWAN EX17162 User manual

EtherWAN

EtherWAN EX17162 User manual

EtherWAN EX17016 User manual

EtherWAN

EtherWAN EX17016 User manual

EtherWAN EX42300 series User manual

EtherWAN

EtherWAN EX42300 series User manual

EtherWAN EX26484 Series User manual

EtherWAN

EtherWAN EX26484 Series User manual

EtherWAN EX34000 User manual

EtherWAN

EtherWAN EX34000 User manual

EtherWAN EX38000 Series User manual

EtherWAN

EtherWAN EX38000 Series User manual

EtherWAN TG103H User manual

EtherWAN

EtherWAN TG103H User manual

Popular Switch manuals by other brands

A-Neuvideo ANI-16-4K60-S instruction manual

A-Neuvideo

A-Neuvideo ANI-16-4K60-S instruction manual

Planet IKVM-8000 user manual

Planet

Planet IKVM-8000 user manual

Black Box SW542A manual

Black Box

Black Box SW542A manual

AirLive ETHER-GSH2404W user manual

AirLive

AirLive ETHER-GSH2404W user manual

Advantech EKI-2526PI user manual

Advantech

Advantech EKI-2526PI user manual

Comtech EF Data CRS-170A Installation and operation manual

Comtech EF Data

Comtech EF Data CRS-170A Installation and operation manual

Quark-Elec QK-R043 manual

Quark-Elec

Quark-Elec QK-R043 manual

Phoenix Contact SWITCH 1008E Installation notes for electricians

Phoenix Contact

Phoenix Contact SWITCH 1008E Installation notes for electricians

Varilight V-Pro IR instructions

Varilight

Varilight V-Pro IR instructions

Cisco 500 Series quick start guide

Cisco

Cisco 500 Series quick start guide

Chroma Magic Box user manual

Chroma

Chroma Magic Box user manual

AVARRO 0E-HDMIMX4 manual

AVARRO

AVARRO 0E-HDMIMX4 manual

Comtrend Corporation GS-7608 user manual

Comtrend Corporation

Comtrend Corporation GS-7608 user manual

IOGear MiniView GCS78 quick start guide

IOGear

IOGear MiniView GCS78 quick start guide

GarrettCom Magnum 14E Installation and user guide

GarrettCom

GarrettCom Magnum 14E Installation and user guide

H3C S9500E Series Configuration guide

H3C

H3C S9500E Series Configuration guide

Hirschmann MSM20 user manual

Hirschmann

Hirschmann MSM20 user manual

Johnson Controls OLS-2000 Product/Technical Bulletin

Johnson Controls

Johnson Controls OLS-2000 Product/Technical Bulletin

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.