EYELA SB-1300 User manual

取扱説明書
取扱説明書
SB-1300 230V
R02
Water Bath
This instruction manual is designed to use the product safely while keeping its best
performance.
Please keep this manual in a place easily accessible to every user.
IMPORTANT Be sure to read “Safety precautions” before use.
Tokyo Rikakikai Co., Ltd.
取扱説明書
Instruction Manual
Combining with
Rotary Evaporator

The unit is not explosion-proof. Take extreme
care no to spill any liquid when using a
flammable specimen or organic solvent.
This product is designed to operate with the
internal mechanism in the hot bath rotating due
to its functionalities and features. Also, this
product contains glass components and requires
careful handling in order to avoid a personal
injury or accidents. Most of such accidents can be
prevented if such danger can be assumed
beforehand.
To ensure the safety, this manual defines the
information on such matters as requiring particular
care in the safety for each danger and attaches the
alert mark and signal word.
It is recommended to follow the instruction to ensure
the safe use of the product.
We have undertaken thorough verification concerning the possible occurrence of risk when
using the product, but prediction of all and every kind of risk is extremely difficult. Namely,
cautions contained in this manual are not necessarily all of possible risks.
However, if the product is operated according to the procedure described in this manual, the
safe operation and work is ensured. Be sure to pay utmost care during handling of the product
to prevent accident or failure of the product.
Alert mark
Signal word Definition
Wrong handling can cause the possibility of the death or heavy
injury of the user.
Wrong handling can to cause the risk of injury of the operator
or physical damages to operators.
Warning
Caution
Important Safety Notice
1. Warning Signal Word

For the very important ones of warnings are
marked on the body of the product in the form of
warning label.
Their positions are as shown below.
The warning labels should be read before using
the product.
* If warning labels become illegible due to
damage on them, replace them with new ones.
Contact us for spare labels.
Water Bath (Model SB-1300)
2. Warning display on the product
CAUTION
Hot surface
Do not move the unit
When liquid
temperature is high.

5. Operation
5-1 Preparation for operation
5-2 Operating procedures
5-3 How to set the alarm function
5-4 How to recover over heat protector
6. Causes of troubles and solutions
7. Maintenance・check-up
7-1 Cleaning and caring the product
7-2 Replacing the fuse
8. Disposal of Products
9. After-sale Services
10. List of consumable & replacement
parts/optional parts
1
2
2
2
3
4
5
6
7
8
9
11
13
14
15
15
16
17
18
1. For safe operation
2. Product Outline
2-1 Application
2-2 How to use
2-3 Specifications
2-4 Names of parts
3. Names and functions of control assembly
3-1 Control panel
3-2 Alarm functions
4. Installation
4-1 Installation environment
4-2 Connecting utilities
Thank you very much for purchasing
product.
Foreword
Contents
Package Contents
This instruction manual describes the procedure of
set-up, operations, troubleshooting, maintenance,
check-up, and disposal of SB-1300, which is water
bath for rotary evaporator.
Be sure to carefully read this manual and understand its
description before using this product.
Be sure to check the types and quantity of parts before installing them.
Also refer to the instruction manuals for the rotary
evaporator N-1300 series and N-1200 series when
using this product.
1
1
2
1
C type O type
B type
Packaged items Qty
4 Instruction manual
1 Main unit
3 Fuse 8A(spare)
2 Power cord
230V Power cord

1
- 1 -
Warning
Caution
This bath is intended for water only. Do not put
liquid other than water (i.e. oil, etc.) into this bath.
Use of liquid other than water (pure water) may cause fire or failure.
Do not put a cover on the bath.
If you use the bath with the cover, heat remains in the bath and it gets hot.
Then the cover may be melted or ignited and it may result in burn or fire.
●Specifically hot part
Do not move the bath when the liquid temperature
is high.
During use or for a certain time after use, the edge of bath and liquid
in the bath get hot. If you move the bath in such case, splashed liquid
or the edge of bath may cause scald.
Edge of bath
Liquid
For safe operation
Caution

2
- 2 -
2-1 Application
2-3 Specifications
For water only.
This product is intended for water only.If you use
liquid other than water (pure water), it may cause fire
or failure.
Caution
Product Name Constant temperature water bath (Water bath)
Model SB-1300
Performance
Temperature set range Room temp.+ 5℃~90℃
Temperature Adjustment Accuracy※1±1℃( during stirring )
Temperature Set Accuracy ※1±5℃( during stirring )
Temperature Indication Range 0~210℃
Functions
Temperature Control P.I.D control
Temperature Indication ・Setting Digital display(Minimum digit1℃)・sheet key input
Safety Functions
・Overheat preventive device (fixed temperature・
liquid bloating manual recovery type)
・Fuse
・Heat insulation protective bath cover
・Self diagnostics function
Sensor disconnection/short-circuit alarm
Outside the measurable temperature range alarm, upper limit alarm
Power outage detection, watch dog
Configu-
ration
Heater 1400W For water only(For heating can body of the bath )
Temperature sensor Pt sensor
Bath cover PET(with glass fiber )
Standard
Material of bath SUS304
Bath capacity Approx. 4.3L
Effective size in the bath φ220×120H (mm)
Container capacity Max 2ℓ
Operating liquid temperature range 10~95℃
Operating environmental temperature range※25~35℃
External dimensions (including handle) W285×D295×H244(mm)
Mass 3.9kg
Rated power supply・power input AC230V 50Hz ・6A
Pollution degree 2
Over voltage category Ⅱ
Operation at a terrestrial altitude Max2000m above sea level
This product is a water bath specifically intended for
heating specimen flask of Rotary Evaporator to conduct
condensation efficiently.
For details of setting methods, see Page 9 “5-2 How
to Operate”.
Product Outline
Warning
Never attempt to modify the product.
Operate the unit for the specified purpose only.
An electric shock or a malfunction may result if the
product is modified or used for any purposes other
than that specified.
2-2 How to use
The temperature of the bath can be set depending on purposes.
With using control panel, the temperature can be set.
Preset temperature can be changed and operation can be
stopped if needed as long as the operation is underway.
※1 Performances have been measured room temperature of 20℃; rated power voltage, 50Hz, no-load, during
stirring (1L flask)
※2 Use the unit at an environment of room temperature :20℃±5℃; humidity:60%or lower when a cool
water (5℃or higher). Allow the inside of the unit to completely dry after use.

- 3 -
2-4 Names of parts
Bath
Bath case
Control panel Power switch
Bath cover
Handle
Overheat preventive
device reset button
Power cord
Power supply inlet
with Fuse(8A×2)
Communication
connector ※
※A special communication cable is used for connection with the vacuum control unit model NVC-3000.

- 4 -
3Names and functions of control assembly
3-1 Control panel
⑧SET key
⑦DOWN key
⑥UP key
⑤RUN/STOP
key
④HEATING lamp
③RUN lamp
①Power switch
②Display
No Name Function
①Power switch Turning this switch ON will turn power ON.
②Display The presented measured temperature of the bath, or the set temperature in
the temperature setting mode is displayed.
Alarm is displayed when an abnormal condition occurs.
③RUN lamp Comes on when temperature control is started.
④HEATING lamp Comes on while the heater is supplied with power.
⑤RUN/STOP key Used to switch start/stop of temperature control.
⑥UP key Each time this key is pressed, the set temperature will rise by 1℃.
The value increments continuously if it is kept pressed.
⑦DOWN key Each time this key is pressed, the set temperature will goes down by 1℃.
The value decrements continuously if it is kept pressed.
⑧SET key Used to switch between the temperature setting and the measurement modes.

- 5 -
※Overheat preventive device activates at approx. 120℃(no-liquid heating)
Safety functions
Safety unit Operation Causes How to recover
Fuse The fuse will blow to shut off
power when overcurrent flows. The power circuit was short-circuited
or was subjected to overcurrent. See P15 “7-2 How to replace
fuses”.
Over heat
preventive device
(high limiter)
Shuts off power to stop control
when the temperature in the
bath reaches the set
temperature for the overheat
preventive unit.
The unit is heating without any load.
The temperature controller was
malfunctioning and the temperature
in the bath rose above the set
temperature of the overheat
preventive unit.
See P13 “5-4 How to
recover the overheat
preventive unit”.
3-2 Alarm functions
The product has the following safety functions.
If you encounter with an abnormality, take appropriate
measures referring to P.14“Possible causes of troubles
and solutions”.
Appears
alternately with the
liquid temperature
・The measured temperature exceeds the upper limit setting of the
temperature.
Check the upper limit temperature setting by referring to “P11 5.3 How to
set the alarm function”. You clear the display with the SET key if the
measured temperature is below the setting.
If you cannot release the alarm, stop operation and contact your dealer or
the nearest service center.
Temperature upper limit
alarm (control stop)
•Measured temperature is below the lower limit of the measurable
temperature range (0℃).
•Measured temperature exceeds the upper limit of the measurable
temperature range (210℃).
Remove any causes or heating or cooling in the unit.
Then check the liquid temperature and the environmental temperature and
take care to keep the temperature in the safety range.
You can clear the display with the SET key if the measured temperature is
within the safe temperature range (0~210℃).
If you cannot release the alarm or the measured temperature is obviously far
different from the actual temperature, immediately stop operation and contact
your dealer or the nearest service center.
Outside the measurable
temperature range alarm
(control stop)
Name / (operation) Display Causes and how to recover
Temperature sensor
alarm (control stop)
・The temperature sensor in the product short-circuited or had a
disconnection.
When this alarm is displayed, immediately stop operating the unit and
contact your dealer or the nearest service center.
Power outage recovery
alarm
(Differs depending on
the A-4 setting)
・Power was shut off during temperature control and power was turned on
again.
You can clear the display with the SET key.
You can set whether temperature control is stopped or continued during
alarm display by setting ON/OFF for the power outage recovery function
(See “P11 5.3 Setting the alarm function” ).
When you cannot clear the display with the SET key or the ON/OFF setting
of the power outage recovery function is not apparently reflected, stop
operation and contact your dealer or the nearest service center.
Alarm functions
Appears
alternately with the
liquid temperature

- 6 -
4Installation
4-1 Installation environment
Never install the product in a
potentially hazardous atmosphere.
The product is not explosion-proof. Use in a
potentially hazardous atmosphere may cause a fire
or other accidents.
Warning
Select a place that meets the conditions below for
installing this product:
●Place that the driving assembly or glass parts will not
come into contact if the evaporator jack is lowered.
●Place free of flammable gas, liquid, or solid
materials in the vicinity of the product.
●Place where the ambient temperature can be kept
within a range of 5~35℃.
●Place free from condensation
●Place with less humidity and free from splashing
water
●Place with minimum dust.
●Place free from direct sunshine
●Place where airy or well-ventilated.
●Level, stable, and firm place

- 7 -
Warning
Connect the ground wire correctly.
Never connect the ground wire to a gas pipe or a
water pipe to avoid an electrical shock .
Warning
Do not use the branching socket or
table tap.
Over-current may cause cable burn, fire.
Power supply to connect
Voltage Capacity
AC230V 8A
* At this time, do not connect the power plug.
* When connecting to the power supply, do not
use a branch socket or table tap.
* Make sure that the sleeve of power cord is not
damaged. Such damage may cause electric
shock.
* Use attached power cord. Otherwise, lack of
capacity, etc. may cause fire or electric shock.
(1) Check the product type as well as the voltage, phase,
and capacity of power supply to be connected.
Power supply to be connected to the product is as
shown in the right.
(2) Check the receptacle of installation place.
Prepare an outlet with a ground terminal.
Specification of Power Cord
4-2 Connecting utilities
Warning
Confirm the voltage, phase, capacity,
and the type of receptacle of power
supply.
Wrong connection of power supply may cause fire or
electric shock
Name Code No
Cable Cros-sectional area of
cable(AWG) Region
covered
Length Thickness
(Outer dia.)
230V Power Cord B Type 245373 Approx.2.0m Approx.6.9mm 1.25mm2(AWG16) India
230V Power Cord C Type 245372 Approx.2.0m Approx.6.9mm 1.25mm2(AWG16) Europe
230V Power Cord O Type 245371 Approx.2.0m Approx.6.9mm 1.25mm2(AWG16) Oceania

- 8 -
5
Do not put the liquid other
than water into the bath.
This product is intended for water (fresh water) only.
If liquid other than water is used, it may cause fire
or failure.
(1) Raise the evaporator jack to the highest point.
(2) Place the bath so that the specimen flask of the
evaporator is at the center of the bath.
(3) Slowly lower the evaporator jack to determine a point
where the flask, the rotary joint or the joint clip does
not come into contact with the bath. (Turn the flask by
hand to make sure that it does not come into contact
with any part.)
※Do not lower the evaporator jack while the bath
handle is at the raised position.
Otherwise, the evaporation may fall or the flask
may break.
(4) Gently pour water (or hot water) in the specimen flask
to the correct level to the capacity of the flask with the
flask put in the bath.
※If water amount is excessive, water may flow over
the specimen flask while it is rotating. Keep the
water level at least 2cm below the top surface of
the bath.
(5) Raise the evaporator jack to the highest point.
※Also refer to instruction manual for rotary
evaporator (N-1300,N-1200 series).
FREE
LOCK
Operation
5-1 Preparation for operation
Warning
1. Installation of the bath
2.Connecting the power cord
(1)Insert the power socket into the power inlet at the back
of the bath.
(2)Make sure that the power switch at the side of the bath
is OFF and then insert the power plug into the outlet.
OFF state ON state
Power switch
Specimen flask
Jack
Bath
Handle
Power socket
Power inlet
Power plug
To the outlet
Power cord

- 9 -
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
5-2 Operating procedures
Stop using the product if you find
any trouble.
When you face the trouble, turn off the power switch
immediately and refer to “6.Troubleshooting”on
page14
Do not touch the hot part during
use and for a while after use.
Bath and flask for specimen are in hot temperature
during use and for a while after use. Touching these
parts may burn yourself.
Completely allow the inside of the unit to dry after using water of a
temperature below the room temperature.
Use the unit under the environment below when you are going to use the unit with cool water (5℃or higher)
below the room temperature.
Completely allow the inside of the unit to dry after using cool water.
※When cool water is used, condensation water may drip from inside the unit onto the experiment table.
<Use environment> Room temperature:20℃±5℃; humidity:60% or less
Caution Caution
Caution
※Make sure that a correct amount of water is in the bath.
(1) Turn the power switch ON.
The whole display comes on, indicates the model [ Sb], the mode
switches to the measurement mode and displays the present liquid
temperature.
(Temperature indication on)
(2) Pressing the SET key switches to the setting input mode.
(Temperature indication flashes)
※The temperature is set to “25” at the time of factory shipping.
※The setting in the last session, if any, will be displayed.
(3) Use the UP key and the DOWN key to set a temperature.
Each press of the UP key increases the set temperature by 1℃and
each press of the DOWN key decreases it by 1℃.
(Keeping them pressed will continually increase or decrease the
value.)
※When any key operations are made for 10 seconds or more in
the setting input mode, the set temperature indicated at that
time will be input and the mode will switch to the measurement
mode.
(4) Pressing the SET key switches to the measurement mode and the
temperature setting is completed. The display will show the current
liquid temperature.
(Temperature indication on)
(5) Pressing the RUN/STOP keys start temperature control at the set
temperature.
(RUN lamp on)
Lighting
Input of settings
Flash
OFF state ON state
Flash

- 10 -
※About the handle
Although it is designed to be highly endurable, it might
deteriorate or break depending on the use environment.
※Water entering inside the unit may cause an electric leak or
an electric shock.
Be sure to remove the power cord before starting draining
or cleaning.
(6) When the liquid temperature in the bath has been
stable, press the power key of the evaporator to turn it
to ON, lower the jack slowly to soak the specimen
flask in the liquid.
Take extreme care not to make the liquid spill over.
When the amount of liquid is insufficient, replenish
liquid little by little taking care liquid will not spill
over the flask.
※Although the product has been designed so that
any spilled water from the bath will not enter
inside, if water should enter in the unit, an electric
leakage or an electric shock may result.
If a spill should occur, first wipe off any moisture
off the bath body, allow it to completely dry at a
well-ventilated place before attempting to use it
again. (When drying, do not place it upside down
or on its side.)
(7) Rotate the specimen flask to start condensation.
※Raise the rotation speed only slowly to avoid the
water from spilling over or ruffling.
※Take care not to burn yourself since hot water
may ruffle while the flask is rotating.
※Do not put the cover on the bath.
The cover may burn from the heater heat. And
overheating may cause inside the bath hot and a
malfunction may result.
(8) To finish operating, stop the evaporator rotation, raise
the jack, release vacuum, press the RUN/STOP key to
stop temperature control and then turn all power OFF.
FREE LOCK
Handle
Procedures after operation
※Be sure to press the RUN/STOP key to stop
temperature control before turning the power
switch OFF.
This product has an automatic recovery function
(power outage recovery function).
Turning the power switch OFF in the RUN state
will turn the heater on at the same time as power
and an accident may result.
Specimen flask
Jack
Power key RUN/STOP key
Rotation adjusting knob
If you are not going to use the product for a long time, turn the
power switch OFF and remove the power cord out of the outlet.
Completely drain the bath and carefully wipe any moisture with
a dry cloth.

Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
- 11 -
5-3 How to set the alarm function
You can set the upper temperature for the upper temperature limit alarm [A-0] or the power outage recovery
function in the setting of the alarm function.
※You cannot set the sensor alarm [F-1] or the outside the measurable temperature range alarm [---].
1.Setting the upper temperature limit alarm
(1) Pressing the SET key in the alarm function setting mode ([A-0]
indication on) will indicate the setting for the upper
temperature limit. (Upper temperature limit setting flashes)
(2) Use the UP key and the DOWN key to set the upper
temperature limit.
Each press of the UP key increases the set temperature by 1℃
and each press of the DOWN key decreases it by 1℃.
(Keeping them pressed will continually increase or decrease the
value.)
※Upper temperature limit setting range:+10℃~120℃
※The temperature is set at the upper limit temperature
“120℃” at the time of factory shipping.
(5) Pressing the SET key switches to the alarm function setting
mode and the setting of the upper temperature limit is
completed.
([A-0] indication on)
(6) Press the SET key long for about 5 seconds to return to the
measurement mode.
(1) Press the SET key longer in the measurement (current
temperature indication on).
(2) Pressing long for about 5 seconds switches to the alarm
function setting mode.
([A-0] indication on)
(3) Use the UP key and the DOWM key to switch the items
for the alarm function setting.
[A-0]…Setting of the upper temperature limit alarm
function
[A-4]…Setting the power outage recovery function
*Returning to the measurement mode
Pressing the SET key long for about 5 seconds during
the alarm function setting mode ([A-4] or [A-0]
indication on)
Pressing the SET key long for about 5 seconds returns
you to the measurement mode.
(current temperature indication on)
*Shifting to the alarm function setting mode
Keep pressed longer for about 5 sec.
UP key or DOWN key UP key or
DOWN key
Keep pressed longer for about 5 sec.
Input of settings
Flash
Flash

- 12 -
2.Setting the power outage recovery function
You can set whether temperature control will be resumed when power is turned on again after power outage during
temperature control by setting ON/OFF of the power outage recovery function.
Set Run
Stop
▼▲
℃
Run
Heating
Set Run
Stop
▼▲
℃
Run
Heating
Flash
Set Run
Stop
▼▲
℃
Run
Heating
Flash
Change settings
Set Run
Stop
▼▲
℃
Run
Heating
(1) Pressing the SET key in the alarm function setting mode ([A-4]
indication on) will indicate the current state of the power outage
recovery function.
[ on]…Power outage recovery function ON
:Temperature control starts at the set temperature on recovery from
power outage.
[oFF]… Power outage recovery function OFF
:Temperature control will not start even on recovery from power
outage.
※The setting is [ on] at the factory shipping.
(2) Use the UP key and the DOWN key to set ON/OFF for the power
outage recovery function.
(3) Pressing the SET key switches to the alarm function setting mode
and the setting of the power outage recovery function is completed.
([A-4] indication on)
(4) Press the SET key long for about 5 seconds to return to the
measurement mode.
・When the power outage recovery function is ON…Temperature control resumes after power recovery in the
state immediately before the recovery.
・When the power outage recovery function is OFF…After power recovery, temperature control stops irrespective
of the state immediately before power outage.
※When power outage occurred during temperature control, [A-4] and the measured temperature will
appear alternately after recover irrespective of the setting for the power outage recovery function.
Press the SET key to clear the indication.

- 13 -
ON
OFF
Hot surface
Caution
In case that over heat protector does not recover
even after pressing reset switch, the temperature in
the bath is still hot. For preventing physical injury
and etc., do not put your hands into the bath. Press
the switch after the temperature falls.
※When the overheat preventive unit is activated, the
power switch is ON but the display is off.
(1) Turn the power switch OFF.
(2) Confirm the suspected causes for the overheat
preventive unit to have activated (liquid amount is
sufficient or not, or the operating environmental
temperature is 35℃or below), make sure that the inside
of the bath has sufficiently cooled down and then press
the reset button of the overheat preventive unit.
(3) Turn the power switch ON.
(4) The display comes on again and temperature control
starts. (RUN lamp on)
※If the temperature in the bath when the power is
turned on by turning the power switch ON after
resetting the overheat preventive unit, the heater
will be activated automatically (power outage
recovery mode) and you should take care for
possible burning or no-liquid heating.
※If the over heat protector still works after
proceeding above-mentioned instructions,stop
operation immediately and call your local dealer
or closest customer service center.
Recovery procedures
5-4 How to recover over heat protector
Power switch
Overheat preventive
unit reset button

6
- 14 -
Symptom Possible causes Solutions
The display will not come on even if the
power switch is turned ON.
The power plug has come off the outlet.
Or is not inserted securely. Turn the power switch OFF and securely insert the
power plug into the outlet.
The power plug has come off the inlet.
Or is not inserted securely. Turn the power switch OFF and securely insert
the power cord into the inlet.
Power is not supplied. Turn the ELB on the distribution board ON.
The overheat preventive unit (high limiter) has
activated.
Recover the overheat preventive unit by referring
to “P13 How to recover the overheat preventive
unit”.
The power switch is malfunctioning. Immediately stop operation and contact your
dealer or the nearest service center.
The temperature controller is malfunctioning.
The inlet fuse has blown.
(Overcurrent has flown.)
Replace the fuse by referring to “P15 Replacing
the fuse”.
If the same symptom repeats after replacement,
confirm the surrounding state and contact your
dealer or the nearest service center.
Power is not supplied to the outlet.
The power plug has come off the outlet.
Or is not inserted securely. Turn the power switch OFF and securely insert the
power plug into the outlet.
The power plug has come off the inlet.
Or is not inserted securely. Turn the power switch OFF and securely insert the
power cord into the inlet.
The outlet fuse has blown.
(Overcurrent has flown.)
The outlet of this product is dedicated for the
evaporator N series.
Never connect any devices other than above.
Replace the fuse by referring to “P15 Replacing
the fuse”.
If the same symptom repeats after replacement,
confirm the surrounding state and contact your
dealer or the nearest service center.
Temperature will not increase.
(RUN lamp is on and HEATING lamp is off)
Temperature is not set. Check the set temperature.
The set temperature is lower than the liquid
temperature.
Temperature will not increase.
(RUN lamp is off and HEATING lamp is on) The RUN/STOP key is not pressed. Press the RUN/STOP key to start temperature
control.
Temperature rises above the set temperature.
(HEATING lamp is off)
Set temperature is low. Start condensation and make sure that the
temperature falls.
The environmental temperature is higher than the
measured temperature. Use the product at a set temperature higher than
the environmental temperature (5~35℃).
SSR is malfunctioning.
Immediately stop operation and contact your
dealer or the nearest service center.
Temperature will not increase.
(HEATING lamp is on)
The heater is disconnected.
SSR is malfunctioning.
The temperature controller is malfunctioning.
Sensor disconnection/short-circuited alarm
[F-1] is displayed. The temperature control sensor is short-circuited.
The temperature sensor is disconnected.
Out of the measurable temperature range
alarm [---] is displayed.
A liquid other than water was used and the
measured result is outside the indication limit
(210℃).
This product is for water only and do not use any
liquids other than water.
The environmental temperature is 0℃or below. Use the product at an environmental temperature
of 5~35℃.
The measured value exceeds the lower limit of
display (0℃). Immediately stop operation and contact your
dealer or the nearest service center.
The upper temperature limit alarm ([A-
0][Liquid temperature] is displayed
alternately) is displayed.
The measured value exceeds the upper limit
temperature.
Check the upper temperature limit by referring to
“P11.5-3 How to set the alarm function”.
Adjust the liquid temperature and the
environmental temperature so that the measured
temperature will meet the upper temperature limit.
The heater is disconnected. Immediately stop operation and contact your
dealer or the nearest service center.
SSR is malfunctioning.
The temperature controller is malfunctioning.
The indication [888] flashes repeatedly on
power on and the measured temperature will
not appear. The temperature controller is malfunctioning. Immediately stop operation and contact your
dealer or the nearest service center.
Contact your dealer or the nearest service
center for troubles not listed here.
Causes of troubles and solutions

- 15 -
Maintenance・check-up
7
7-1 Cleaning and caring the product
Warning Caution
(1) Make sure that the RUN lamp is off.
(2) Make sure the liquid temperature has sufficiently
cooled down, turn the power switch OFF and
remove the power plug out of the outlet.
(3) Drain the liquid in the bath.
(4) Use a tightly wrung off soft cloth for cleaning.
Use mild detergent for stubborn dirt and completely
remove any remaining detergent.
Do not clean and care the product
while it is still hot.
Cleaning and caring the product while it is
still hot may burn yourself.
Caution Caution
Use appropriate product for cleaning
and caring the unit in proper way.
When cleaning and caring the product, do not
pour water directly on the external and internal
portion, and also do not use cleanser, thinner,
petrol, lamp oil, acid and related products.
These products may cause electric shock or
damage the unit.
Remove the scale on the bath
immediately
Continuing use with a stone may cause overheat of
the bath bottom and damage the product.
Caution
Do not scratch the bath.
Inner surface of the bath is Teflon coated for being
cleaned efficiently.
Scratching the inner surface may damage the
product.
Never attempt to disassemble the
product.
The unit contains parts with high voltage applied or
may become hot, and disassembly may cause an
electrical shock or an injury.
7-2 Replacing the fuse
(1) Turn the power switch OFF and pull out the power
cord from inlet with fuse.
(2) Use a small flat-head screwdriver or the like to remove
the fuseholder.
(3) Replace the 2 fuses with new ones at the same time.
(4) After replacement, push the fuseholder to the end.
※When the inlet fuse is blown while the unit is in
operation, take care for burning or a no-liquid
heating because the heater will automatically turn
on (power outage recovery mode) at powering on
if the temperature in the bath is below the set
temperature for checking the display. ※Only use a fuse with the same standard and
the capacity as the old one.
Pull out this part
Time-delay
Type fuse
(8A)
Inlet with fuse
Fuseholder
Specification Capacity
Slow blow type, φ5.2×20 T8A
①
②

8
- 16 -
Components Model Weight External dimensions (Including
handle) How to discard
Main body SB-1300 Approx.3.9
kg 285(W)×295(D)×244(H) Request the disposal operator for
disposal.
Components Major materials
Heater integrated bath Stainless steel, aluminum, ceramics
Bath cover PET(containing glass fibers)
Body case PBT(containing glass fibers)
Handle PP
Metal sheet Aluminum, iron, stainless steel
Disposal of Products
Disposal of product or part must be done according to the specified disposal method.
Principal components parts and disposal method
*We ask you to discard packing materials after classifying them by material types.
Table of contents
Other EYELA Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Belden
Belden HIRSCHMANN RPI-P1-4PoE installation manual

Koehler
Koehler K1223 Series Operation and instruction manual

Globe Scientific
Globe Scientific GCM-12 quick start guide

Getinge
Getinge 86 SERIES Technical manual

CORNING
CORNING Everon 6000 user manual

Biocomp
Biocomp GRADIENT MASTER 108 operating manual