4DUOX PLUS AUDIO CITYLINE-MARINE KIT 1 WAY ILOFT
TECHNICAL FEATURES
PANEL VALUES
Lock-release activation time 01...99 sec. (Default: 03)
Exit button activation time 00...99 sec. (Default: 06) / (deactivated: 00)
Panel type sub-block/block/general entrance. (Default: block)
Panel number 0..9 (by default: 00)
MASTER panel: not active.
PANEL TECHNICAL CHARACTERISTICS
Power Supply 18-24 Vdc
Standby Consumption 1,1 W
Audio active consumption 13,2 (max) W
Audio Power in Residence - Entry Panel Direction 1 W
Audio Power in Entry Panel - Residence Direction 0.15 W
Operating temperature [-25º , +55ºC] / [-13º, 131ºF]
Volume can be Regulated in Both Directions.
TELEPHONE TECHNICAL CHARACTERISTICS
Power supply 18-24 Vdc
Standby consumption 0,4 W
Maximum consumption 3,6 W
Operating temperature [-5º , +40ºC]
WIRING DIAGRAMS
SECTIONS-DISTANCES TABLE
- (i) For the 12Vdc lock-release and max. consumption 250mA, powered by the amplier.
SECTION
CABLE
TERMINALS per home
without additional power
source
Maximum distance (A) Source/
Filter up to Panel (Panel-Lock
release) (i)
1500
1500
1250
2500
250
2250
200
2150
80
3250
3200
3100
OUTPUT
INPUT
REF. 4825
100-240V;1,2 A
50-60Hz
PROTEGIDOPOR FUSIBLE ELECTRÓNICO
ELECTRONICFUSE PROTECTED
24V; 2,5 A
ON
OVERLOAD
ALIMENTADOR - POWER SUPPLY
BB
POWER BUS
PREV BUS
NOVOLTAGE / SIN TENSIÓN
PASDE TENSION / NICHT SPANNUNG
NL
Vac
BB
Ref. 4825
Maximum distance (B)
Source/Filter up to Panel
Furthest terminal
Distance section table - AUDIO KIT INSTALLATION
OUTPUT
INPUT
REF. 4825
100-240V;1,2 A
50-60Hz
PROTEGIDOPOR FUSIBLE ELECTRÓNICO
ELECTRONICFUSE PROTECTED
24V; 2,5 A
ON
OVERLOAD
ALIMENTADOR - POWER SUPPLY
BB
POWER BUS
PREV BUS
NOVOLTAGE / SIN TENSIÓN
PASDE TENSION / NICHT SPANNUNG
NL
BB
Ref. 4825
3. ENCODING PANELS*
Whenever there is more than one panel, you must program the number of panels.
4. LOCK RELEASE ACTIVATION TIME*
To adjust the lock-release activation time.
*Note: See Voice assisted conguration in button panels cod. 970064. Instructions included with this equipment.