Power Recovery
If the power supply is cut off suddenly while the
instrument is in operation, the unit will automatically run
at the previously set parameter upon power restoration.
The display window will flash. Press any button to stop
flashing.
8
Table of Mode Combinations
ON
ON
ON
ON
ON ON
ON
ONON ON
ON
OFF
OFF
OFF OFF
OFF
OFF
WAIT WAIT
WAIT
WAIT
WAIT
8910 11 12 13 14
ON
OFF
ON
OFF
WAIT
OFF
ON
OFF OFF
ON
Reciprocal
ON
ON
ON
Orbital
Vibrate
1 2 3456 7
Reciprocal
Orbital
While operating in timer mode, the instrument will stop
running automatically when the timer goes off and the
alarm will sound.
After the operation is finished, please press the power
switch at the back right side the instrument and put it
into the “O” state. Unplug the instrument and store the
instrument according to the storage guide.
Finish Operation
Alarm System
ONONONOFF OFFWAITWAIT
Vibrate
3.3 Settings
1. Single mode continuous operation 1.1 Press “ ”to select
operation mode needed and the corresponding indicator
light will be on. Press “ ” or “ ” on the left to set
rotation speed and angle needed in the left-hand-side LED
display window. (Press “ ” to switch settings between
speed and angle).
1.2 Press “ ”or “ ” on the right to set any time.
1.3 Press “ ” until Cycle Indicator Light is on. Press“ ”
on the right to decrease the time to 0.
1.4 Press “ ” to start operation.
1.5 Press “ ” again to end operation.
2. Single mode timed operation
2.1 Press “ ”to select operation mode needed and the
corresponding indicator light will be on. Press “ ” or “ ”
on the left to set rotation speed and angle needed in the
left-hand-side LED display window. (Press “ ” to switch
settings between speed and angle)
2.2 Press “ ”or “ ” on the right to set time needed.
2.3 Press “ ”again until Cycle Indicator Light is on. Press “ ”
or “ ” to set the required number of cycles which is between
0-125. (Timer range is the product of set time and number of
cycles. The maximum time that can be set is 250 ×125 =31250
seconds.)
2.4 Press “ ”to start operation.
2.5 Press “ ”o end operation.
3.Multi-mode continuous operation
3.1 Press “ ” to select operation mode needed and the
corresponding indicator light will be on. Press “ ”or “ ”
on the left to set rotation speed and angle needed in the left
-hand-side LED display window. (Press “ ” to switch settings
between speed and angle)
3.2 Press “ ”or “ ” on the right to set time needed.
3.3 After setting one operation mode, press “ ” again to
switch to another mode indicated by the corresponding
indicator light and repeat step 3.1, 3.2 to set corresponding
parameters.
3.4 Combination of 2-3 operation modes is allowed. (When
the time is set to 0, the procedure will skip the corresponding
mode during operation.)
3.5 Press “ ” until the Cycle Indicator Light is on. Press
“ ”or “ ” on the right to decrease the number of cycles
to 0.
3.6 Press “ ” to start operation.
3.7 Press “ ” to end operation.
4. Multi-mode timed operation
4.1 Press “ ”to select operation mode needed and the
correspon-ding indicator light will be on. Press “ ” or “ ”
on the left to set rotation speed and angle needed in the left
-hand-side LED display window (Press “ ” to switch settings
between speed and angle).
4.2 Press “ ”or “ ” on the right to set time needed.
4.3 After setting one operation mode, press “ ”again to
switch to another mode indicated by the corresponding
indicator light and repeat set 4.1, 4.2 to set corresponding
parameters.
4.4 Combination of 2-3 operation modes is allowed. (When
the time is set to 0, the procedure will skip the
corresponding mode during operation.)
4.5 Press “ ” until the Cycle Indicator Light is on. Press
“ ”or “ ” on the right to set the number of cycles
between 0-125.
4.6 Press “ ” to start operation.