manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FLIR
  6. •
  7. Measuring Instrument
  8. •
  9. FLIR Extech Instruments PQ34-2 User manual

FLIR Extech Instruments PQ34-2 User manual

This manual suits for next models

1

Other FLIR Measuring Instrument manuals

FLIR Extech Instruments MA1500 User manual

FLIR

FLIR Extech Instruments MA1500 User manual

FLIR VS80 KIT User manual

FLIR

FLIR VS80 KIT User manual

FLIR Extech PQ3450-30 User manual

FLIR

FLIR Extech PQ3450-30 User manual

FLIR CM55 User manual

FLIR

FLIR CM55 User manual

FLIR Extech Instruments MA150 User manual

FLIR

FLIR Extech Instruments MA150 User manual

FLIR VS80C10-25RM User manual

FLIR

FLIR VS80C10-25RM User manual

FLIR MR277 User manual

FLIR

FLIR MR277 User manual

FLIR EXTECH INSTRUMENTS PQ34-12 User manual

FLIR

FLIR EXTECH INSTRUMENTS PQ34-12 User manual

FLIR Extech Instruments EX840 User manual

FLIR

FLIR Extech Instruments EX840 User manual

FLIR DM284 User manual

FLIR

FLIR DM284 User manual

FLIR Extech Instruments 380193 User manual

FLIR

FLIR Extech Instruments 380193 User manual

FLIR EXTECH HDV-WTX1 User manual

FLIR

FLIR EXTECH HDV-WTX1 User manual

FLIR CM174 User manual

FLIR

FLIR CM174 User manual

FLIR CM72 User manual

FLIR

FLIR CM72 User manual

FLIR EXTECH HDV-WTX1 Dimensions

FLIR

FLIR EXTECH HDV-WTX1 Dimensions

FLIR ME13552 User manual

FLIR

FLIR ME13552 User manual

FLIR MR160 User manual

FLIR

FLIR MR160 User manual

FLIR CM78 User manual

FLIR

FLIR CM78 User manual

FLIR CM65 User manual

FLIR

FLIR CM65 User manual

FLIR EXTECH HDV-WTX2 User manual

FLIR

FLIR EXTECH HDV-WTX2 User manual

FLIR EXTECH MA620 User manual

FLIR

FLIR EXTECH MA620 User manual

FLIR IMAGING MOISTURE METER with IGM MR160 User manual

FLIR

FLIR IMAGING MOISTURE METER with IGM MR160 User manual

FLIR identiFINDER R300 User manual

FLIR

FLIR identiFINDER R300 User manual

FLIR CM94 User manual

FLIR

FLIR CM94 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User's Guide
1200A Current Probe Set
Model PQ34-12
23
www. .com information@itm.com1.800.561.8187
PQ-12-EU-EN V1.0 01/12
2
Introduction
Congratulations on your purchase of this Extech Current Probe Set. A set of three 1200A current
probes designed to be used with the Extech PQ3450 or PQ3470 Power Analyzers. These probes
are shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
Safety
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages
may be present
Double insulation
Cautions
Read and understand this user manual before operating the meter.
Improper use of this meter can cause damage, shock, injury or death.
Inspect the condition of the leads and the meter itself for any damage before operating the
meter.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Do not attempt to measure Current that exceeds specified limits
Do not operate this instrument in wet or dusty environments.
Do not operate this instrument in the presence of combustible or explosive gas
Do not touch exposed metal parts or unused terminals.
Use protective gloves near high current or voltage circuits.
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
www. .com information@itm.com1.800.561.8187
PQ-12-EU-EN V1.0 01/12
3
Probe Description
1. Current Sensing Jaws
2. Jaw Trigger
3. 1200A-200A-20A range switch
4. Signal output plug ( +, red )
5. Signal output plug ( -, black )
6. DCV power plug
Operation
1. Connect the “A1” signal output cables to the matching input sockets
on the top of the analyzer.
2. Connect the “A1” power cable to the matching power socket on the
top of the analyzer.
3. Set the "1200A-200A-20A” range switch to the range appropriate for
the application.
Note: Make sure the range set on the clamp matches the range
set in the analyzer.
4. Connect the “A2” and “A3” clamps as above, if needed.
5. Press the "Trigger" to open the jaws and clamp around a single
conductor.
6. Power on the power analyzer
1
2
3
4
56
www. .com information@itm.com1.800.561.8187
PQ-12-EU-EN V1.0 01/12
4
Specifications
Measurement ranges 20A, 200A and 1200A, switch selectable
Output sensitivity 10mV/A on the 20A range
1mV/A on the 200A range
0.1mV/A on the 1200A range
Output coupling AC coupled.
Accuracy (50/60Hz) ± 1% F.S. @ 23 ± 5°C
Frequency range 45 to 400 Hz.
Phase error (50/60Hz) < ± 1°
Minimum load 100 K ohm for specified accuracy
Enclosure material UL 94-V0 rated
Safety IEC 1010, Category III 600V
Power Supply 8V± 1V (supplied from meter)
Max. Jaw Open Size 50 mm (2.0 inch) Dia.
Operating Temperature 0°C to 50°C (32°F to 122°F)
Operating Humidity Less than 80% RH
Dimension 210 x 64 x 33 mm. (8.3 X 2.5 X 1.3”inch )
Cable length : 4 meters (13.17 feet)
DC plug size : 5.5 mm x 2.5 mm DIA.
Weight 490 g (1.08 LB)
Safety For indoor use and in accordance with the requirements for
indoor use, double insulation to IEC1010-1 (2001):
EN61010-1 (2001) Overvoltage Category III 600V,, Pollution
Degree 2.
www.extech.com